{"id":7536,"date":"2026-11-11T16:45:43","date_gmt":"2026-11-11T08:45:43","guid":{"rendered":"https:\/\/tebaoflex-cable.com\/?page_id=7536"},"modified":"2026-11-12T10:20:36","modified_gmt":"2026-11-12T02:20:36","slug":"customer-factory-visit-epr-cable-testing","status":"publish","type":"page","link":"https:\/\/tebaoflex-cable.com\/de\/cases\/customer-factory-visit-epr-cable-testing\/","title":{"rendered":"Kundenbesuch im Werk: Pr\u00fcfungen f\u00fcr 11-kV- und 33-kV-EPR-Kabelanwendungen"},"content":{"rendered":"\n<style>\n.tbf-case-pg{max-width:960px;margin-left:auto;margin-right:auto;--ink:#16202b;--muted:#5b6b7c;--line:#e2e8ee;--accent:#b4381f;--soft:#f6f8fa;color:var(--ink);line-height:1.7;font-size:17px}\n.tbf-case-pg h1{font-size:2rem;line-height:1.2;margin:0 0 .6rem}\n.tbf-case-pg h2{font-size:1.5rem;margin:2.4rem 0 .5rem;border-top:3px solid var(--ink);padding-top:.5rem}\n.tbf-case-pg h3{font-size:1.08rem;margin:1.4rem 0 .3rem}\n.tbf-case-pg p{margin:0 0 1rem}\n.tbf-case-pg a{color:var(--accent);text-underline-offset:2px}\n.tbf-kicker{font-size:.75rem;letter-spacing:.1em;text-transform:uppercase;font-weight:700;color:#1f7a5c;margin-bottom:.4rem}\n.tbf-lede{font-size:1.1rem;color:var(--muted)}\n.tbf-case-pg table{width:100%;border-collapse:collapse;margin:1.1rem 0;font-size:.96rem}\n.tbf-case-pg th,.tbf-case-pg td{border:1px solid var(--line);padding:.55rem .75rem;text-align:left;vertical-align:top}\n.tbf-case-pg th{background:var(--soft);width:34%;font-weight:700}\n.tbf-wide{min-width:620px}\n.tbf-wide th{width:auto}\n.tbf-tw{overflow-x:auto}\n.tbf-hero{margin:1.3rem 0 .3rem}\n.tbf-hero img{width:100%;height:auto;display:block;border-radius:10px;border:1px solid var(--line);background:#fff}\n.tbf-hero figcaption,.tbf-fig figcaption{font-size:.85rem;color:var(--muted);margin-top:.4rem}\n.tbf-fig{margin:1.4rem 0}\n.tbf-fig img{width:100%;max-width:520px;height:auto;display:block;margin:0 auto;border-radius:10px;border:1px solid var(--line);background:#fff}\n.tbf-shots{display:grid;grid-template-columns:1fr 1fr;gap:1rem;margin:1.4rem 0}\n.tbf-shots figure{margin:0}\n.tbf-shots img{width:100%;height:360px;object-fit:contain;background:#fff;border-radius:10px;border:1px solid var(--line);display:block}\n.tbf-shots figcaption{font-size:.85rem;color:var(--muted);margin-top:.4rem}\n.tbf-scope{border:1px dashed var(--line);border-radius:8px;padding:.85rem 1.1rem;margin:1.2rem 0;font-size:.92rem;color:var(--muted);background:var(--soft)}\n.tbf-eng{background:var(--soft);border-left:3px solid var(--ink);padding:.2rem 1.1rem .6rem;margin:1.2rem 0;border-radius:0 8px 8px 0}\n.tbf-eng .tag{display:inline-block;font-size:.7rem;letter-spacing:.09em;text-transform:uppercase;font-weight:700;color:var(--muted);margin:.9rem 0 .2rem}\n.tbf-need{background:#fdf6f4;border-left:3px solid var(--accent);padding:.9rem 1.1rem;margin:1.2rem 0;border-radius:0 8px 8px 0}\n.tbf-need ul{margin:.4rem 0 0;padding-left:1.1rem;columns:2;column-gap:2rem}\n.tbf-need li{margin:.2rem 0;break-inside:avoid}\n.tbf-rel ul{padding-left:1.1rem;columns:2;column-gap:2rem}\n.tbf-rel li{margin:.22rem 0;break-inside:avoid}\n.tbf-faq details{border-bottom:1px solid var(--line);padding:.8rem 0}\n.tbf-faq summary{cursor:pointer;font-weight:600}\n.tbf-faq p{margin:.55rem 0 0;color:var(--muted)}\n.tbf-cta{display:inline-block;background:var(--accent);color:#fff!important;text-decoration:none!important;border-radius:8px;padding:.6rem 1.15rem;font-weight:600;margin-top:.5rem}\n.tbf-byline{font-size:.92rem;color:var(--muted);background:var(--soft);border-radius:8px;padding:.85rem 1.1rem;margin:1.6rem 0}\n.tbf-back{font-size:.9rem;margin-top:2rem;padding-top:1rem;border-top:1px solid var(--line)}\n@media(max-width:640px){.tbf-shots{grid-template-columns:1fr}.tbf-need ul,.tbf-rel ul{columns:1}.tbf-case-pg th{width:auto}}\n\n.tbf-case-pg caption{caption-side:top;text-align:left;font-weight:700;font-size:.95rem;color:var(--ink);margin-bottom:.45rem}\n.tbf-case-pg ul.tbf-list,.tbf-case-pg ol.tbf-list{padding-left:1.2rem;margin:0 0 1rem}.tbf-case-pg .tbf-list li{margin:.3rem 0}\n.tbf-case-pg .tbf-answer{font-size:1.03rem;border-left:3px solid #1f7a5c;padding:.15rem 0 .15rem .95rem;color:var(--ink)}\n.tbf-case-pg .tbf-visit-video{margin:1.3rem 0 1.5rem}\n.tbf-case-pg .tbf-visit-video video{object-fit:contain;display:block;width:100%;height:auto;aspect-ratio:16\/9;border:0;border-radius:10px;background:#16202b}\n.tbf-shots img{object-fit:cover}\n@media(max-width:640px){.tbf-case-pg h1{font-size:1.65rem}.tbf-shots{grid-template-columns:1fr}.tbf-shots img{height:auto}}\n<\/style>\n<div class=\"tbf-case-pg\">\n<p class=\"tbf-kicker\">Case 15 \u00b7 Customer factory visit \u00b7 Medium-voltage EPR cable testing<\/p>\n<h1>Customer Factory Visit: Testing for 11 kV and 33 kV EPR Cable Applications<\/h1>\n<p class=\"tbf-lede\">An overseas customer visited the TEBAOFLEX factory in Taicang (recorded 11 November 2026) for 11 kV and 33 kV EPR cable testing, port crane power and multicore control sample review, and a production workshop walk-through. On camera, he explains why verifying full requested conductor cross-section against undersized substitutions such as 120 mm\u00b2 for 150 mm\u00b2 was a primary check for his team, and describes witnessing high-voltage dielectric testing before clearing orders for port, offshore oil and gas, and industrial clients.<\/p>\n<figure class=\"tbf-hero tbf-visit-video tfv-page\" id=\"visit-video\" aria-labelledby=\"tbf-visit-video-caption\">\n<video controls playsinline preload=\"none\" width=\"960\" height=\"540\" data-no-lazy=\"1\" poster=\"https:\/\/tebaoflex-cable.com\/wp-content\/uploads\/2026\/11\/tebaoflex-customer-factory-visit-cable-testing.jpg\">\n<source src=\"https:\/\/tebaoflex-cable.com\/wp-content\/uploads\/2026\/11\/tebaoflex-case-15-customer-factory-visit-original-40eb9ed2.mp4\" type=\"video\/mp4\" data-no-lazy=\"1\">\n<\/video>\n<figcaption id=\"tbf-visit-video-caption\">On-site customer interview recorded in the TEBAOFLEX workshop and testing room (1 min 54 sec). <a href=\"https:\/\/www.youtube.com\/watch?v=uMYcOsjX7FU\" rel=\"nofollow noopener\" target=\"_blank\">Watch the 1 min 54 sec factory visit video on YouTube<\/a>.<\/figcaption>\n<\/figure>\n<h2 id=\"visit-at-a-glance\">Visit at a glance<\/h2>\n<p class=\"tbf-answer\">The customer factory visit recorded on 11 November 2026 at TEBAOFLEX in Taicang covered two on-site verification steps for 11 kV and 33 kV EPR cable projects: confirming that delivered copper conductor cross-sections match the ordered specification, and witnessing high-voltage withstand testing alongside port crane and offshore sample checks.<\/p>\n<div class=\"tbf-tw\"><table><caption>Summary of the on-site customer factory visit and laboratory review<\/caption><thead><tr><th scope=\"col\">Visit item<\/th><th scope=\"col\">Recorded detail<\/th><\/tr><\/thead><tbody>\n<tr><th scope=\"row\">Factory location<\/th><td>TEBAOFLEX special-cable production workshop and testing laboratory, Taicang, Jiangsu, China<\/td><\/tr>\n<tr><th scope=\"row\">Visiting buyer<\/th><td>Overseas cable supplier inspecting production and testing with client requirements in hand (company name not published)<\/td><\/tr>\n<tr><th scope=\"row\">Medium-voltage focus<\/th><td>11 kV and 33 kV power cable applications using EPR insulation<\/td><\/tr>\n<tr><th scope=\"row\">Other duties reviewed<\/th><td>Port crane power and multicore control cables; offshore oil and gas and industrial plant supply<\/td><\/tr>\n<tr><th scope=\"row\">Checks highlighted<\/th><td>Requested conductor cross-section verification on cut samples and high-voltage withstand testing in the lab<\/td><\/tr>\n<tr><th scope=\"row\">Recorded video length<\/th><td>1 min 54 sec workshop walk-through and testing-room interview published 11 November 2026<\/td><\/tr>\n<\/tbody><\/table><\/div>\n<div class=\"tbf-scope\"><strong>Scope note.<\/strong> This page separates what the visitor states on camera from the standard acceptance rules that govern medium-voltage orders. In the recording, 11 kV and 33 kV identify the EPR application classes his team came to verify, and his comparison between 150 mm\u00b2 and 120 mm\u00b2 illustrates why conductor verification matters rather than naming the exact cross-section of the two cut pieces in his hand. Applied test voltages, hold durations and ohmmeter readings are not spoken in the video; those figures belong on the drum-specific routine test report written to the contract standard.<\/div>\n<h2 id=\"conductor-size-verification\">Why do buyers check 150 mm\u00b2 vs 120 mm\u00b2 conductor size at the factory?<\/h2>\n<p class=\"tbf-answer\">Overseas cable buyers verify conductor size at the factory because substituting a 120 mm\u00b2 copper core for a specified 150 mm\u00b2 build raises maximum 20 \u00b0C DC resistance on a Class 5 plain-copper flexible conductor from 0.129 \u03a9\/km to 0.161 \u03a9\/km under IEC 60228 \u2014 a 24.8% jump in conductor resistance and I\u00b2R heating. Under IEC 60228:2023, nominal cross-section is proven by completed-cable 20 \u00b0C DC resistance rather than caliper diameter alone.<\/p>\n<div class=\"tbf-shots\">\n<figure><img fetchpriority=\"high\" src=\"https:\/\/tebaoflex-cable.com\/wp-content\/uploads\/2026\/11\/tebaoflex-factory-visit-mv-epr-conductor-check.webp\" alt=\"Visiting customer inspecting two cut medium-voltage EPR cable samples beside the conductor resistance test bench and tensile tester in the TEBAOFLEX lab\" width=\"1508\" height=\"848\" fetchpriority=\"high\" decoding=\"async\" data-no-lazy=\"1\"><figcaption>Customer inspecting two cut medium-voltage EPR cable samples in the TEBAOFLEX lab; behind him sit the 1-metre conductor DC resistance clamp bench (left) and vertical tensile testers (right).<\/figcaption><\/figure>\n<figure><img loading=\"lazy\" src=\"https:\/\/tebaoflex-cable.com\/wp-content\/uploads\/2026\/11\/tebaoflex-factory-visit-port-crane-epr-sample.webp\" alt=\"Visiting customer holding a red-sheathed multicore port crane cable sample in the TEBAOFLEX cable testing laboratory\" width=\"1680\" height=\"848\" loading=\"lazy\" decoding=\"async\"><figcaption>Customer holding a red-sheathed multicore port crane cable sample while discussing separate power and control circuits for crane operations.<\/figcaption><\/figure>\n<\/div>\n<p>During the laboratory stop (0:42 to 1:18 in the 11 November 2026 recording), the visitor points to a recurring procurement hazard: ordering a 150 mm\u00b2 cable and receiving a 120 mm\u00b2 conductor from a supplier who claims the smaller cross-section is close enough. Visual inspection of a cut end catches gross down-gauging, yet caliper diameter across a stranded copper bundle is not conclusive on its own. Under IEC 60228, a compacted Class 2 core, a concentric-lay core and a fine-stranded Class 5 rope-lay core of the same nominal mm\u00b2 sit at different geometric diameters because lay ratios and air voids differ.<\/p>\n<p><a href=\"https:\/\/webstore.iec.ch\/en\/publication\/71891\" rel=\"nofollow noopener\" target=\"_blank\">IEC 60228:2023<\/a> defines nominal conductor cross-section through electrical performance: compliance is checked on completed cable by measuring DC resistance, correcting the reading to 20 \u00b0C and comparing it against the maximum \u03a9\/km table for the declared conductor class and metal finish (plain or tinned). On the left workbench in the laboratory photograph above, a 1-metre four-terminal Kelvin bridge clamp fixture checks cut samples directly, while full drum lengths are measured end to end during routine testing. How IEC Classes 1, 2, 5 and 6 differ from North American ASTM stranding letters is set out in our <a href=\"https:\/\/tebaoflex-cable.com\/conductor-stranding-classes\/\">conductor stranding classes engineering guide<\/a>.<\/p>\n<div class=\"tbf-tw\"><table class=\"tbf-wide\"><caption>Factory comparison: specified 150 mm\u00b2 vs substituted 120 mm\u00b2 copper conductor<\/caption><thead><tr><th scope=\"col\">Verification item<\/th><th scope=\"col\">150 mm\u00b2 Class 5 plain copper<\/th><th scope=\"col\">120 mm\u00b2 Class 5 substitution<\/th><th scope=\"col\">Confirm before ordering or at FAT<\/th><\/tr><\/thead><tbody>\n<tr><th scope=\"row\">150 mm\u00b2 vs 120 mm\u00b2 max DC resistance at 20 \u00b0C<\/th><td>0.129 \u03a9\/km (verified Class 5 plain-copper datasheet row to IEC 60228)<\/td><td>0.161 \u03a9\/km (+24.8% higher resistance and I\u00b2R loss at identical load current)<\/td><td>Write conductor size, IEC 60228 class, plain or tinned finish, and 20 \u00b0C \u03a9\/km ceiling into the order<\/td><\/tr>\n<tr><th scope=\"row\">Cut-end caliper check<\/th><td>Confirms strand lay, screen layers and approximate bundle diameter<\/td><td>Can mask copper shortfall if strand pitch or filler geometry is altered<\/td><td>Treat cut-sample caliper checks as a visual screen alongside bridge resistance measurement<\/td><\/tr>\n<tr><th scope=\"row\">Completed-drum routine check<\/th><td>End-to-end DC resistance measured on each drum and corrected to 20 \u00b0C<\/td><td>Fails the 150 mm\u00b2 routine resistance ceiling across the full manufactured length<\/td><td>Require measured \u03a9\/km per drum number on the routine test report before release<\/td><\/tr>\n<\/tbody><\/table><\/div>\n<h2 id=\"mv-epr-high-voltage-testing\">How are 11 kV and 33 kV EPR cables tested before shipment?<\/h2>\n<p class=\"tbf-answer\">Medium-voltage 11 kV and 33 kV EPR cables undergo routine electrical tests on every manufactured drum length before shipment: conductor DC resistance at 20 \u00b0C, partial discharge measurement on screened cores, and a power-frequency AC high-voltage withstand test between each conductor and the metallic screen. Fixed-distribution standards such as IEC 60502-2 and IS 7098-2 prescribe different test voltages from flexible reeling standards such as DIN VDE 0250-813, so the order must name the exact standard.<\/p>\n<div class=\"tbf-shots\">\n<figure><img loading=\"lazy\" src=\"https:\/\/tebaoflex-cable.com\/wp-content\/uploads\/2026\/11\/tebaoflex-factory-visit-hv-test-room.webp\" alt=\"Visiting customer beside the high-voltage AC test console and enclosed test cage in the TEBAOFLEX cable testing laboratory\" width=\"1508\" height=\"848\" loading=\"lazy\" decoding=\"async\"><figcaption>Customer beside the AC high-voltage dielectric test console (left) and the yellow-fenced high-voltage test enclosure visible through the doorway (right).<\/figcaption><\/figure>\n<figure><img loading=\"lazy\" src=\"https:\/\/tebaoflex-cable.com\/wp-content\/uploads\/2026\/11\/cable-high-voltage-test-set-panel.webp\" alt=\"Control panel of a cable high-voltage test set in the TEBAOFLEX factory showing test voltage, withstand timer, input current and input voltage displays\" width=\"1600\" height=\"820\" loading=\"lazy\" decoding=\"async\"><figcaption>Close-up of the TEBAOFLEX high-voltage test set control panel displaying applied test voltage, withstand timer, input current and input voltage.<\/figcaption><\/figure>\n<\/div>\n<p>At 1:19 to 1:30 in the clip, the customer describes putting the cable through high-voltage testing in the factory bay to confirm that the insulation withstands the required test stress without breakdown. In medium-voltage cable manufacturing, buyers sometimes refer to all pre-shipment electrical checks as a high-voltage test, yet standards split factory testing into three distinct tiers: <strong>routine tests<\/strong> made on every drum length, <strong>sample (acceptance) tests<\/strong> made on cut pieces from production lots (covering insulation and sheath wall thickness, external diameter and the hot-set test for EPR crosslinking), and <strong>type tests<\/strong> performed once on a cable design to prove bending, thermal-cycling and impulse performance.<\/p>\n<p>Because 11 kV and 33 kV projects span both fixed distribution cables (<a href=\"https:\/\/webstore.iec.ch\/en\/publication\/95394\" rel=\"nofollow noopener\" target=\"_blank\">IEC 60502-2<\/a> for 6 kV to 30 kV extruded cables, or IS 7098-2 up to 33 kV) and flexible crane or mining cables (such as DIN VDE 0250-813 up to 18\/30 kV, Um 36 kV), the applied AC withstand voltage and partial discharge test multiple must come from the standard named on the purchase specification. Full tier definitions, lot sampling rules and a nine-point order checklist are detailed in our <a href=\"https:\/\/tebaoflex-cable.com\/cable-factory-acceptance-test\/\">cable factory acceptance test (FAT) guide<\/a>, and an order-specific routine test record at 17 kV AC for 5 minutes is documented in our <a href=\"https:\/\/tebaoflex-cable.com\/cases\/medium-voltage-submersible-pump-cable-replacement-kazakhstan\/\">6\/10 kV submersible pump cable replacement case<\/a>.<\/p>\n<div class=\"tbf-tw\"><table class=\"tbf-wide\"><caption>Representative medium-voltage routine electrical test benchmarks by governing standard<\/caption><thead><tr><th scope=\"col\">Voltage designation &#038; standard<\/th><th scope=\"col\">Routine AC withstand test<\/th><th scope=\"col\">Routine partial discharge check<\/th><th scope=\"col\">Confirm before ordering<\/th><\/tr><\/thead><tbody>\n<tr><th scope=\"row\">6.35\/11 kV fixed MV cable (IS 7098-2 reference)<\/th><td>21 kV AC for 5 minutes, conductor to screen or armour<\/td><td>\u2264 10 pC at 1.73 U\u2080 (approx. 11.0 kV) on full drum length<\/td><td>Confirm whether the specification invokes IEC 60502-2, IS 7098-2 or BS 6622 test tables<\/td><\/tr>\n<tr><th scope=\"row\">19\/33 kV fixed MV cable (IS 7098-2 reference)<\/th><td>63 kV AC for 5 minutes, conductor to screen or armour<\/td><td>\u2264 10 pC at 1.73 U\u2080 (approx. 32.9 kV) on full drum length<\/td><td>Verify U\u2080\/U (Um) class (18\/30 kV vs 19\/33 kV) and termination screen geometry<\/td><\/tr>\n<tr><th scope=\"row\">6\/10 kV flexible EPR cable (DIN VDE 0250-813 project reference)<\/th><td>17 kV AC for 5 minutes on power cores (per agreed Kazakhstan MV pump order)<\/td><td>Per product standard and core-screen construction<\/td><td>Use DIN VDE 0250-813 or ICEA S-75-381 for reeling and trailing duty; IEC 60502-2 excludes mining\/reeling<\/td><\/tr>\n<tr><th scope=\"row\">EPR crosslinking check (IEC 60502-2 \/ EN 50525 sample tier)<\/th><td>Hot-set elongation under load in oven (sample piece, not a drum voltage test)<\/td><td>Not applicable (mechanical-thermal sample check)<\/td><td>Confirm sample frequency and extra sacrificial cut length before production starts<\/td><\/tr>\n<\/tbody><\/table><\/div>\n<h2 id=\"port-crane-mv-offshore-routing\">Where EPR power and control cables fit across port cranes, 11\u201333 kV feeders, and offshore equipment<\/h2>\n<p class=\"tbf-answer\">EPR insulation serves three distinct application groups discussed during the factory visit: dynamic port-crane reeling and spreader circuits requiring fine-stranded copper and anti-torsion jackets, fixed or flexible 11 kV to 35 kV medium-voltage feeders rated 90 \u00b0C or 105 \u00b0C, and halogen-free offshore power and control cables built to NEK TS 606. Choosing the right family depends on whether the route is fixed, festooned, or wound under tension on a motorized drum.<\/p>\n<p>In the opening and closing segments of the interview (0:09 to 0:26 and 1:31 to 1:45), the visitor connects his factory audit to three real project streams: port crane power and multicore control cables, 11 kV and 33 kV medium-voltage EPR feeders, and cable supply for offshore oil and gas and manufacturing plants. Ethylene propylene rubber appears across all three because cross-linked EPR stays flexible in cold or vibrating routes while maintaining dielectric strength and a 90 \u00b0C continuous rating (105 \u00b0C in MV-105 builds), as explained in our <a href=\"https:\/\/tebaoflex-cable.com\/epr-insulation\/\">EPR cable insulation technical guide<\/a>. However, an EPR compound code alone does not make two medium-voltage cables interchangeable: a fixed distribution cable lacks the anti-twisting braid and fine Class 5 conductor stranding needed on a quay-crane monospiral drum.<\/p>\n<div class=\"tbf-tw\"><table class=\"tbf-wide\"><caption>Routing the factory-visit application groups to TEBAOFLEX EPR cable constructions<\/caption><thead><tr><th scope=\"col\">Cable family &#038; voltage range<\/th><th scope=\"col\">Core &#038; insulation build<\/th><th scope=\"col\">Target duty from visit<\/th><th scope=\"col\">Choose this when<\/th><\/tr><\/thead><tbody>\n<tr><th scope=\"row\">Type MV-105 EPR Distribution (15 kV &amp; 35 kV) \u2014 <a href=\"https:\/\/tebaoflex-cable.com\/product\/type-mv-105-epr-distribution-cable-15kv-35kv\/\">15\u201335 kV MV-105 cable page<\/a><\/th><td>Class B stranded copper\/Al, 105 \u00b0C NL-EPR insulation, copper-tape screen, PVC jacket<\/td><td>Fixed 11 kV\u201333 kV class substation, tray and duct power distribution<\/td><td>Route is fixed in trays, ducts or racks and requires 105 \u00b0C EPR thermal margin up to 35 kV<\/td><\/tr>\n<tr><th scope=\"row\">(N)TSCGEW\u00d6U \/ F-(N)TSCGEW\u00d6U (3.6\/6 to 18\/30 kV, Um 36 kV) \u2014 <a href=\"https:\/\/tebaoflex-cable.com\/product\/ntscgewoeu-mv-crane-reeling-cable\/\">(N)TSCGEW\u00d6U crane reeling page<\/a> &amp; <a href=\"https:\/\/tebaoflex-cable.com\/product\/f-ntscgewou-medium-voltage-cable\/\">F-(N)TSCGEW\u00d6U 3.6\/6\u201318\/30 kV page<\/a><\/th><td>Class 5 flexible copper, 3GI3 MV-EPR insulation, semiconductive screens, anti-torsion elastomer sheath<\/td><td>Medium-voltage port quay cranes, ship unloaders and bulk yard reels across the 11 kV to 33 kV range<\/td><td>Cable winds continuously on and off a motorized crane or stacker-reclaimer drum under dynamic tension<\/td><\/tr>\n<tr><th scope=\"row\">PANZERFLEX-L \/ VS Multicore (0.6\/1 kV) \u2014 <a href=\"https:\/\/tebaoflex-cable.com\/product\/panzerflex-l-vs-reeling-spreader-cable\/\">PANZERFLEX port reeling &amp; spreader page<\/a><\/th><td>Class 5 copper, EPR core insulation, 24G to 48G numbered control cores or 4G\/5G power, PCP\/PUR sheath<\/td><td>Port crane vertical spreader reels, trolley festoons and auxiliary control circuits<\/td><td>Separating low-voltage crane control from main gantry power (full subsystem map on our <a href=\"https:\/\/tebaoflex-cable.com\/solutions\/port-container-cranes\/\">port and container crane solutions page<\/a>)<\/td><\/tr>\n<tr><th scope=\"row\">RFOU Offshore Power &amp; Control (0.6\/1 kV) \u2014 <a href=\"https:\/\/tebaoflex-cable.com\/product\/ultimate-rfou-cable-marine-offshore\/\">NEK 606 RFOU offshore cable page<\/a><\/th><td>Tinned stranded copper, EPR insulation, halogen-free bedding, tinned-copper wire braid, SHF2 outer sheath<\/td><td>Fixed offshore oil and gas topside power and control installations<\/td><td>Project specifies IEC 60092 \/ NEK TS 606 halogen-free offshore builds (verify drilling-fluid mud grade separately; see our <a href=\"https:\/\/tebaoflex-cable.com\/solutions\/oil-gas-petrochemical\/\">oil, gas and petrochemical cable solutions<\/a>)<\/td><\/tr>\n<\/tbody><\/table><\/div>\n<h2 id=\"witnessed-fat-checklist\">What to send before scheduling a factory visit or witnessed cable test<\/h2>\n<p class=\"tbf-answer\">Schedule a witnessed factory acceptance test when confirming the purchase order, before stranding and extrusion start, so drum holding times, sacrificial sample lengths, and high-voltage bay slots are built into the production schedule. Sending the rated voltage U\u2080\/U, governing standard, conductor size and class, drum lengths, and witness test list lets engineering issue an agreed inspection plan with the quotation.<\/p>\n<div class=\"tbf-need\"><strong>Include these seven items with your enquiry so our engineering team can confirm the cable construction, routine test values and witness schedule before production.<\/strong>\n<ul>\n<li>System voltage and cable voltage designation U\u2080\/U (Um), such as 6.35\/11 (12) kV, 8.7\/15 (17.5) kV, 18\/30 (36) kV or 19\/33 (36) kV<\/li>\n<li>Governing construction and test standard (for example IEC 60502-2, IS 7098-2, DIN VDE 0250-813 or NEK TS 606)<\/li>\n<li>Nominal conductor cross-section (mm\u00b2 or AWG\/kcmil), IEC\/ASTM stranding class, plain or tinned copper finish, and core count<\/li>\n<li>Mechanical duty: fixed tray\/duct installation, festoon loop, vertical spreader basket, or motorized drum reeling speed and travel length<\/li>\n<li>Individual drum lengths, continuous joint-free length requirements, and agreed outer-sheath print legend with sequential metre marks<\/li>\n<li>Which checks your team or third-party inspector plans to witness in person (20 \u00b0C DC resistance, AC high-voltage withstand, partial discharge, hot-set, dimensional strip checks)<\/li>\n<li>Target inspection window and destination port so test bay booking and wooden-drum packing align with vessel cut-off dates<\/li>\n<\/ul>\n<p>Once the governing standard and drum schedule are confirmed, the written quotation lists the routine and sample test records supplied before dispatch alongside any witnessed test window.<\/p><\/div>\n<p><a class=\"tbf-cta\" href=\"https:\/\/tebaoflex-cable.com\/contact-us\/#request-quote\">Send your cable specification and FAT witness list &rarr;<\/a><\/p>\n<h2 id=\"faq\">Questions on EPR cable factory visits and witnessed testing<\/h2>\n<div class=\"tbf-faq\">\n<details><summary>How do you verify that a 150 mm\u00b2 cable is not an undersized 120 mm\u00b2 build?<\/summary><p>Check the completed-cable conductor DC resistance at 20 \u00b0C on each drum rather than relying on caliper diameter alone. Under IEC 60228, a Class 5 plain-copper flexible conductor has a maximum 20 \u00b0C DC resistance of 0.129 \u03a9\/km at 150 mm\u00b2 versus 0.161 \u03a9\/km at 120 mm\u00b2, so an undersized core fails the routine resistance limit even if compaction hides the visual difference.<\/p><\/details>\n<details><summary>Which tests are run on every 11 kV and 33 kV EPR cable drum before shipment?<\/summary><p>Medium-voltage cables receive routine electrical tests on every manufactured drum length: conductor DC resistance corrected to 20 \u00b0C, partial discharge measurement on screened power cores, and a power-frequency AC high-voltage withstand test between conductor and screen. Sample checks such as insulation thickness, outside diameter and hot-set crosslinking are performed on cut production pieces at the lot frequency set by the governing standard.<\/p><\/details>\n<details><summary>What AC test voltage applies to 11 kV and 33 kV cables in the factory?<\/summary><p>The routine AC withstand voltage depends on the rated voltage U\u2080\/U and the standard named in the purchase order. In IS 7098-2, for example, the 5-minute routine AC test between conductor and screen is 21 kV for 6.35\/11 kV cables and 63 kV for 19\/33 kV cables, alongside a routine partial discharge limit of 10 pC at 1.73 U\u2080; flexible reeling standards such as DIN VDE 0250-813 set their own test levels.<\/p><\/details>\n<details><summary>Why are EPR cables specified for both port cranes and 11\u201333 kV feeders?<\/summary><p>Ethylene propylene rubber (EPR) combines elastomeric flexibility with wet dielectric stability and a 90 \u00b0C continuous conductor rating under IEC 60502-2 (up to 105 \u00b0C in Type MV-105 grades per UL 1072). That allows compound formulations in the EPR family to serve both tight-bending port crane reeling or spreader cables and medium-voltage industrial or offshore power feeders where rigid XLPE is too stiff to route.<\/p><\/details>\n<details><summary>When should an overseas buyer book a witnessed factory acceptance test?<\/summary><p>Confirm witnessed inspection when placing the purchase order, before conductor stranding and extrusion begin. Advance scheduling lets the factory reserve high-voltage test bay time, hold completed drums unlagged for visual and marking checks, and prepare extra sample length where destructive hot-set or dimensional strip tests are part of the agreed inspection plan.<\/p><\/details>\n<\/div>\n<div class=\"tbf-byline\">Factory visit and testing record prepared by <a href=\"https:\/\/tebaoflex-cable.com\/author\/zheng-lipeng\/\">Zheng LiPeng<\/a>, Manager, with the TEBAOFLEX cable engineering team \u00b7 Published <time datetime=\"2026-11-11\">11 November 2026<\/time>. TEBAOFLEX is a special-cable factory in Taicang, Jiangsu, founded in 2014, with 12 production lines from rubber mixing to cabling and 8 sets of test equipment (as of September 2026). Learn more about our workshop and test facilities on our <a href=\"https:\/\/tebaoflex-cable.com\/about-us\/\">about us page<\/a>.<\/div>\n<div class=\"tbf-back\"><a href=\"https:\/\/tebaoflex-cable.com\/cases\/\">&larr; Browse all TEBAOFLEX industrial cable application cases<\/a><\/div>\n<\/div>\n\n<script type=\"application\/ld+json\">{\"@context\": \"https:\/\/schema.org\", \"@type\": \"Article\", \"headline\": \"Customer Factory Visit: Testing for 11 kV and 33 kV EPR Cable Applications\", \"description\": \"Customer factory visit at TEBAOFLEX for 11 kV and 33 kV EPR cables: conductor cross-section verification, high-voltage testing, video and FAT checklist.\", \"mainEntityOfPage\": {\"@type\": \"WebPage\", \"@id\": \"https:\/\/tebaoflex-cable.com\/cases\/customer-factory-visit-epr-cable-testing\/\"}, \"url\": \"https:\/\/tebaoflex-cable.com\/cases\/customer-factory-visit-epr-cable-testing\/\", \"inLanguage\": \"en\", \"image\": [{\"@type\": \"ImageObject\", \"url\": \"https:\/\/tebaoflex-cable.com\/wp-content\/uploads\/2026\/11\/tebaoflex-customer-factory-visit-cable-testing.jpg\", \"width\": 1920, \"height\": 1080}, {\"@type\": \"ImageObject\", \"url\": \"https:\/\/tebaoflex-cable.com\/wp-content\/uploads\/2026\/11\/tebaoflex-factory-visit-mv-epr-conductor-check.webp\", \"width\": 1508, \"height\": 848}, {\"@type\": \"ImageObject\", \"url\": \"https:\/\/tebaoflex-cable.com\/wp-content\/uploads\/2026\/11\/tebaoflex-factory-visit-hv-test-room.webp\", \"width\": 1508, \"height\": 848}, {\"@type\": \"ImageObject\", \"url\": \"https:\/\/tebaoflex-cable.com\/wp-content\/uploads\/2026\/11\/cable-high-voltage-test-set-panel.webp\", \"width\": 1600, \"height\": 820}], \"video\": {\"@type\": \"VideoObject\", \"@id\": \"https:\/\/tebaoflex-cable.com\/cases\/customer-factory-visit-epr-cable-testing\/#visit-video\", \"name\": \"Customer Factory Visit: Checking Conductor Size and Witnessing 11 kV & 33 kV EPR Cable Testing at TEBAOFLEX\", \"description\": \"A visiting overseas customer tours the TEBAOFLEX workshop and testing laboratory in Taicang, explaining why verifying requested conductor cross-section and witnessing high-voltage testing matter for 11 kV and 33 kV EPR cables, port crane power and multicore control cables, and offshore supply.\", \"thumbnailUrl\": [\"https:\/\/tebaoflex-cable.com\/wp-content\/uploads\/2026\/11\/tebaoflex-customer-factory-visit-cable-testing.jpg\"], \"uploadDate\": \"2026-11-11T08:32:22Z\", \"duration\": \"PT1M54S\", \"contentUrl\": \"https:\/\/tebaoflex-cable.com\/wp-content\/uploads\/2026\/11\/tebaoflex-case-15-customer-factory-visit-original-40eb9ed2.mp4\", \"inLanguage\": \"en\", \"publisher\": {\"@id\": \"https:\/\/tebaoflex-cable.com\/#organization\"}, \"encodingFormat\": \"video\/mp4\", \"width\": 1920, \"height\": 1080}, \"author\": {\"@type\": \"Person\", \"@id\": \"https:\/\/tebaoflex-cable.com\/author\/zheng-lipeng\/\", \"name\": \"Zheng LiPeng\", \"url\": \"https:\/\/tebaoflex-cable.com\/author\/zheng-lipeng\/\", \"jobTitle\": \"Manager\", \"image\": \"https:\/\/tebaoflex-cable.com\/wp-content\/uploads\/2026\/09\/tebaoflex-author-headshot-100x100.jpg\", \"sameAs\": [\"https:\/\/www.linkedin.com\/in\/tebaoflexcable\/\"], \"worksFor\": {\"@id\": \"https:\/\/tebaoflex-cable.com\/#organization\"}}, \"publisher\": {\"@type\": \"Organization\", \"@id\": \"https:\/\/tebaoflex-cable.com\/#organization\", \"name\": \"TEBAOFLEX\", \"url\": \"https:\/\/tebaoflex-cable.com\/\"}, \"about\": [\"11 kV and 33 kV EPR cable testing\", \"Cable factory acceptance test\", \"IEC 60228 conductor resistance verification\", \"Port crane EPR power and control cables\"], \"datePublished\": \"2026-11-11\", \"dateModified\": \"2026-11-12\"}<\/script>\n<script type=\"application\/ld+json\">{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"How do you verify that a 150 mm\u00b2 cable is not an undersized 120 mm\u00b2 build?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Check the completed-cable conductor DC resistance at 20 \u00b0C on each drum rather than relying on caliper diameter alone. Under IEC 60228, a Class 5 plain-copper flexible conductor has a maximum 20 \u00b0C DC resistance of 0.129 \u03a9\/km at 150 mm\u00b2 versus 0.161 \u03a9\/km at 120 mm\u00b2, so an undersized core fails the routine resistance limit even if compaction hides the visual difference.\"}}, {\"@type\": \"Question\", \"name\": \"Which tests are run on every 11 kV and 33 kV EPR cable drum before shipment?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Medium-voltage cables receive routine electrical tests on every manufactured drum length: conductor DC resistance corrected to 20 \u00b0C, partial discharge measurement on screened power cores, and a power-frequency AC high-voltage withstand test between conductor and screen. Sample checks such as insulation thickness, outside diameter and hot-set crosslinking are performed on cut production pieces at the lot frequency set by the governing standard.\"}}, {\"@type\": \"Question\", \"name\": \"What AC test voltage applies to 11 kV and 33 kV cables in the factory?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The routine AC withstand voltage depends on the rated voltage U\u2080\/U and the standard named in the purchase order. In IS 7098-2, for example, the 5-minute routine AC test between conductor and screen is 21 kV for 6.35\/11 kV cables and 63 kV for 19\/33 kV cables, alongside a routine partial discharge limit of 10 pC at 1.73 U\u2080; flexible reeling standards such as DIN VDE 0250-813 set their own test levels.\"}}, {\"@type\": \"Question\", \"name\": \"Why are EPR cables specified for both port cranes and 11\u201333 kV feeders?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Ethylene propylene rubber (EPR) combines elastomeric flexibility with wet dielectric stability and a 90 \u00b0C continuous conductor rating under IEC 60502-2 (up to 105 \u00b0C in Type MV-105 grades per UL 1072). That allows compound formulations in the EPR family to serve both tight-bending port crane reeling or spreader cables and medium-voltage industrial or offshore power feeders where rigid XLPE is too stiff to route.\"}}, {\"@type\": \"Question\", \"name\": \"When should an overseas buyer book a witnessed factory acceptance test?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Confirm witnessed inspection when placing the purchase order, before conductor stranding and extrusion begin. Advance scheduling lets the factory reserve high-voltage test bay time, hold completed drums unlagged for visual and marking checks, and prepare extra sample length where destructive hot-set or dimensional strip tests are part of the agreed inspection plan.\"}}]}<\/script>\n","protected":false},"excerpt":{"rendered":"<p>Kundenbesuch im TEBAOFLEX-Werk f\u00fcr 11-kV- und 33-kV-EPR-Kabel: \u00dcberpr\u00fcfung des Leiterquerschnitts, Hochspannungspr\u00fcfung, Video und Checkliste f\u00fcr die Werksabnahmepr\u00fcfung (FAT).<\/p>","protected":false},"author":1,"featured_media":7535,"parent":3117,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-7536","page","type-page","status-publish","has-post-thumbnail","hentry"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/tebaoflex-cable.com\/de\/wp-json\/wp\/v2\/pages\/7536","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/tebaoflex-cable.com\/de\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/tebaoflex-cable.com\/de\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/tebaoflex-cable.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/tebaoflex-cable.com\/de\/wp-json\/wp\/v2\/comments?post=7536"}],"version-history":[{"count":7,"href":"https:\/\/tebaoflex-cable.com\/de\/wp-json\/wp\/v2\/pages\/7536\/revisions"}],"predecessor-version":[{"id":7589,"href":"https:\/\/tebaoflex-cable.com\/de\/wp-json\/wp\/v2\/pages\/7536\/revisions\/7589"}],"up":[{"embeddable":true,"href":"https:\/\/tebaoflex-cable.com\/de\/wp-json\/wp\/v2\/pages\/3117"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/tebaoflex-cable.com\/de\/wp-json\/wp\/v2\/media\/7535"}],"wp:attachment":[{"href":"https:\/\/tebaoflex-cable.com\/de\/wp-json\/wp\/v2\/media?parent=7536"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}