{"id":8527,"date":"2026-11-18T13:19:31","date_gmt":"2026-11-18T05:19:31","guid":{"rendered":"https:\/\/tebaoflex-cable.com\/cases\/2yslcyk-j-0-6-1kv-4x120-vfd-motor-cable-data-center-singapore\/"},"modified":"2026-11-19T16:16:15","modified_gmt":"2026-11-19T08:16:15","slug":"2yslcyk-j-0-6-1kv-4x120-vfd-motor-cable-data-center-singapore","status":"publish","type":"page","link":"https:\/\/tebaoflex-cable.com\/de\/cases\/2yslcyk-j-0-6-1kv-4x120-vfd-motor-cable-data-center-singapore\/","title":{"rendered":"Doppelt geschirmte Frequenzumrichter-Motorleitung 2YSLCYK-J 0.6\/1 kV 4\u00d7120 und 4\u00d735 mm\u00b2 f\u00fcr ein Rechenzentrum in Singapur"},"content":{"rendered":"\n<style>\n.tbf-case-pg{max-width:960px;margin-left:auto;margin-right:auto;--ink:#16202b;--muted:#5b6b7c;--line:#e2e8ee;--accent:#b4381f;--soft:#f6f8fa;color:var(--ink);line-height:1.7;font-size:17px}\n.tbf-case-pg h1{font-size:2rem;line-height:1.2;margin:0 0 .6rem}\n.tbf-case-pg h2{font-size:1.5rem;margin:2.4rem 0 .5rem;border-top:3px solid var(--ink);padding-top:.5rem}\n.tbf-case-pg h3{font-size:1.08rem;margin:1.4rem 0 .3rem}\n.tbf-case-pg p{margin:0 0 1rem}\n.tbf-case-pg a{color:var(--accent);text-underline-offset:2px}\n.tbf-kicker{font-size:.75rem;letter-spacing:.1em;text-transform:uppercase;font-weight:700;color:#1f7a5c;margin-bottom:.4rem}\n.tbf-lede{font-size:1.1rem;color:var(--muted)}\n.tbf-case-pg table{width:100%;border-collapse:collapse;margin:1.1rem 0;font-size:.96rem}\n.tbf-case-pg th,.tbf-case-pg td{border:1px solid var(--line);padding:.55rem .75rem;text-align:left;vertical-align:top}\n.tbf-case-pg th{background:var(--soft);width:34%;font-weight:700}\n.tbf-wide{min-width:620px}\n.tbf-wide th{width:auto}\n.tbf-tw{overflow-x:auto}\n.tbf-hero{margin:1.3rem 0 .3rem}\n.tbf-hero img{width:100%;height:auto;display:block;border-radius:10px;border:1px solid var(--line);background:#fff}\n.tbf-hero figcaption,.tbf-fig figcaption{font-size:.85rem;color:var(--muted);margin-top:.4rem}\n.tbf-fig{margin:1.4rem 0}\n.tbf-fig img{width:100%;max-width:520px;height:auto;display:block;margin:0 auto;border-radius:10px;border:1px solid var(--line);background:#fff}\n.tbf-shots{display:grid;grid-template-columns:1fr 1fr;gap:1rem;margin:1.4rem 0}\n.tbf-shots figure{margin:0}\n.tbf-shots img{width:100%;height:360px;object-fit:contain;background:#fff;border-radius:10px;border:1px solid var(--line);display:block}\n.tbf-shots figcaption{font-size:.85rem;color:var(--muted);margin-top:.4rem}\n.tbf-scope{border:1px dashed var(--line);border-radius:8px;padding:.85rem 1.1rem;margin:1.2rem 0;font-size:.92rem;color:var(--muted);background:var(--soft)}\n.tbf-eng{background:var(--soft);border-left:3px solid var(--ink);padding:.2rem 1.1rem .6rem;margin:1.2rem 0;border-radius:0 8px 8px 0}\n.tbf-eng .tag{display:inline-block;font-size:.7rem;letter-spacing:.09em;text-transform:uppercase;font-weight:700;color:var(--muted);margin:.9rem 0 .2rem}\n.tbf-need{background:#fdf6f4;border-left:3px solid var(--accent);padding:.9rem 1.1rem;margin:1.2rem 0;border-radius:0 8px 8px 0}\n.tbf-need ul{margin:.4rem 0 0;padding-left:1.1rem;columns:2;column-gap:2rem}\n.tbf-need li{margin:.2rem 0;break-inside:avoid}\n.tbf-rel ul{padding-left:1.1rem;columns:2;column-gap:2rem}\n.tbf-rel li{margin:.22rem 0;break-inside:avoid}\n.tbf-faq details{border-bottom:1px solid var(--line);padding:.8rem 0}\n.tbf-faq summary{cursor:pointer;font-weight:600}\n.tbf-faq p{margin:.55rem 0 0;color:var(--muted)}\n.tbf-cta{display:inline-block;background:var(--accent);color:#fff!important;text-decoration:none!important;border-radius:8px;padding:.6rem 1.15rem;font-weight:600;margin-top:.5rem}\n.tbf-byline{font-size:.92rem;color:var(--muted);background:var(--soft);border-radius:8px;padding:.85rem 1.1rem;margin:1.6rem 0}\n.tbf-back{font-size:.9rem;margin-top:2rem;padding-top:1rem;border-top:1px solid var(--line)}\n@media(max-width:640px){.tbf-shots{grid-template-columns:1fr}.tbf-need ul,.tbf-rel ul{columns:1}.tbf-case-pg th{width:auto}}\n.tbf-case-pg caption{caption-side:top;text-align:left;font-weight:700;font-size:.95rem;color:var(--ink);margin-bottom:.45rem}.tbf-case-pg ul.tbf-list,.tbf-case-pg ol.tbf-list{padding-left:1.2rem;margin:0 0 1rem}.tbf-case-pg .tbf-list li{margin:.3rem 0}.tbf-case-pg .tbf-answer{font-size:1.04rem;border-left:3px solid #1f7a5c;padding:.1rem 0 .1rem .9rem}.tbf-sys{width:100%;max-width:680px;height:auto;display:block;margin:0 auto}.tbf-diag{margin:1.4rem 0}.tbf-diag ol{padding-left:1.4rem;font-size:.95rem;columns:2;column-gap:2rem}.tbf-diag li{margin:.2rem 0;break-inside:avoid}.tbf-diag figcaption{font-size:.85rem;color:var(--muted);margin-top:.4rem}@media(max-width:640px){.tbf-shots{grid-template-columns:1fr}.tbf-shots img{height:auto}.tbf-diag ol{columns:1}}\n<\/style>\n<div class=\"tbf-case-pg\">\n<p class=\"tbf-kicker\">Case 21 \u00b7 Singapore \u00b7 Compute Data Center \u00b7 Double-screened EMC VFD motor cable<\/p>\n<h1>2YSLCYK-J 0.6\/1 kV 4\u00d7120 &#038; 4\u00d735 mm\u00b2 Double-Screened VFD Motor Cable for a Compute Data Center in Singapore<\/h1>\n<p class=\"tbf-lede\">High-density compute and AI data centers in Singapore rely on variable-frequency-driven chilled-water pumps, cooling-tower fans and air-handling units where high-frequency inverter noise cannot bleed into adjacent control or server power corridors. When a Singapore electrical cable distributor sought a faster manufacturing alternative to long-lead European imports for a compute data center build, TEBAOFLEX manufactured, peel-verified and container-shipped 0.6\/1 kV 2YSLCYK-J double-screened PE VFD motor cables in 4 \u00d7 120 mm\u00b2 and 4 \u00d7 35 mm\u00b2 cross-sections.<\/p>\n<figure class=\"tbf-hero\"><img fetchpriority=\"high\" src=\"https:\/\/tebaoflex-cable.com\/wp-content\/uploads\/2026\/11\/2yslcyk-j-0-6-1kv-4x120-vfd-motor-cable-singapore-hero.webp\" alt=\"Angled cut end of the TEBAOFLEX 2YSLCYK-J 0.6\/1 kV 4\u00d7120 mm\u00b2 double-screened low-capacitance PE VFD motor cable supplied for a Singapore compute data center\" width=\"1200\" height=\"900\" fetchpriority=\"high\" decoding=\"async\" data-no-lazy=\"1\"><figcaption>Cut end of the TEBAOFLEX 2YSLCYK-J 0.6\/1 kV 4\u00d7120 mm\u00b2 double-screened VFD motor cable manufactured for a Singapore compute data center: Class 5 bare copper conductors, low-capacitance PE core insulation, aluminium-laminated foil plus tinned-copper braid screen and black RAL 9005 PVC outer sheath.<\/figcaption><\/figure>\n<h2 id=\"project-at-a-glance\">Project at a glance<\/h2>\n<p class=\"tbf-answer\">This Singapore compute data center order supplied 2YSLCYK-J 0.6\/1 kV double-screened VFD motor cables in 4 \u00d7 120 mm\u00b2 (~292 A at 30 \u00b0C, 49.12 mm verified caliper OD) and 4 \u00d7 35 mm\u00b2 (~135 A, 32.7 mm nominal OD), combining low-capacitance PE insulation with aluminium-foil plus tinned-copper braid EMC shielding.<\/p>\n<div class=\"tbf-tw\"><table><caption>Summary of the Singapore data center 2YSLCYK-J 0.6\/1 kV VFD motor cable supply order<\/caption><thead><tr><th scope=\"col\">Order item<\/th><th scope=\"col\">Verified engineering detail<\/th><\/tr><\/thead><tbody>\n<tr><th scope=\"row\">Destination &#038; facility<\/th><td>Singapore \u2014 high-density compute data center variable-frequency drive (VFD) HVAC\/pump power connections<\/td><\/tr>\n<tr><th scope=\"row\">Supplied cable family<\/th><td>TEBAOFLEX 2YSLCYK-J 0.6\/1 kV PE-insulated double-screened flexible VFD motor cable<\/td><\/tr>\n<tr><th scope=\"row\">Cross-sections delivered<\/th><td>4 \u00d7 120 mm\u00b2 (51.9 mm nominal OD; 49.12 mm caliper verified) and 4 \u00d7 35 mm\u00b2 (32.7 mm nominal OD)<\/td><\/tr>\n<tr><th scope=\"row\">Conductors &#038; core colours<\/th><td>IEC 60228 Class 5 bare copper; brown, black, grey and green-yellow PE insulation per HD 308 S2<\/td><\/tr>\n<tr><th scope=\"row\">Dual EMC screen architecture<\/th><td>1st screen: aluminium-laminated foil (metal side out) \u00b7 2nd screen: tinned-copper wire braid<\/td><\/tr>\n<tr><th scope=\"row\">Dielectric &#038; thermal basis<\/th><td>Uo\/U 0.6\/1 kV (4 kV AC \/ 5 min test); +70 \u00b0C continuous \/ +160 \u00b0C 5 s short-circuit; \u221240 \u00b0C to +70 \u00b0C fixed<\/td><\/tr>\n<tr><th scope=\"row\">Conduit &#038; pulling limits<\/th><td>10 \u00d7 D fixed bend \/ 20 \u00d7 D free movement; max pulling tension 20 N\/mm\u00b2 on copper cross-section<\/td><\/tr>\n<tr><th scope=\"row\">Export packing &#038; dispatch<\/th><td>Moisture-sealed ends on IPPC heat-treated lagged wooden export drums, container-loaded for Singapore<\/td><\/tr>\n<\/tbody><\/table><\/div>\n<div class=\"tbf-scope\"><strong>Scope note.<\/strong> This case record documents the low-capacitance PE dielectric selection, pre-shipment foil-and-braid peel verification, conduit diameter check and export drum packing for the Singapore data center order. Distributor identity, data-center hall operator and contract pricing are withheld under customer confidentiality.<\/div>\n<h2 id=\"why-pe-and-double-screen\">Why do data center VFD pump and cooling feeders specify low-capacitance PE and double screening?<\/h2>\n<p class=\"tbf-answer\">Variable-frequency drives switch IGBT bridges with steep voltage rise times (dV\/dt) that inject high-frequency common-mode currents into motor feeders. Low-capacitance PE (2Y) halves mutual core-to-screen capacitance compared with PVC, while an aluminium-foil plus tinned-copper braid double screen maintains low transfer impedance from kilohertz to megahertz frequencies.<\/p>\n<p>Alongside medium-voltage single-core power feeders\u2014such as our earlier <a href=\"https:\/\/tebaoflex-cable.com\/cases\/singapore-data-center-ntmcgcw11y-mv-cable\/\">Singapore data center 12\/20 kV (N)TMCGCW11Y cable project<\/a>\u2014modern compute halls run dozens of inverter-fed chilled-water pumps, CRAH fans and cooling-tower drives. Using unshielded PVC power cable between an inverter and an AC motor creates two immediate problems explained in our <a href=\"https:\/\/tebaoflex-cable.com\/what-is-vfd-cable\/\">VFD cable engineering guide<\/a>: high mutual capacitance draws large capacitive current spikes at every PWM edge, and uncontained electromagnetic emissions couple into nearby BMS sensors and Ethernet trunks.<\/p>\n<figure class=\"tbf-diag\"><svg class=\"tbf-sys\" viewBox=\"0 0 680 324\" role=\"img\" aria-labelledby=\"tbf-c21-title\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><title id=\"tbf-c21-title\">Schematic cross-section of 2YSLCYK-J 0.6\/1 kV 4\u00d7120 mm\u00b2 low-capacitance PE double-screened VFD motor cable<\/title><circle cx=\"225\" cy=\"162\" r=\"132\" fill=\"#1a1f24\" stroke=\"#0c0f12\" stroke-width=\"2\"\/><circle cx=\"225\" cy=\"162\" r=\"113\" fill=\"none\" stroke=\"#cfd5dc\" stroke-width=\"6\" stroke-dasharray=\"5,3\"\/><circle cx=\"225\" cy=\"162\" r=\"106\" fill=\"none\" stroke=\"#6aa6d8\" stroke-width=\"3.2\"\/><circle cx=\"225\" cy=\"162\" r=\"102\" fill=\"#eef2f6\" stroke=\"#b8c4d0\" stroke-width=\"1.2\"\/><circle cx=\"183\" cy=\"120\" r=\"41\" fill=\"#8b5a2b\" stroke=\"#161b20\" stroke-width=\"1.1\"\/><circle cx=\"183\" cy=\"120\" r=\"31\" fill=\"#c97a3d\" stroke=\"#7d481e\" stroke-width=\"1\"\/><circle cx=\"267\" cy=\"120\" r=\"41\" fill=\"#22272c\" stroke=\"#161b20\" stroke-width=\"1.1\"\/><circle cx=\"267\" cy=\"120\" r=\"31\" fill=\"#c97a3d\" stroke=\"#7d481e\" stroke-width=\"1\"\/><circle cx=\"183\" cy=\"204\" r=\"41\" fill=\"#8f98a0\" stroke=\"#161b20\" stroke-width=\"1.1\"\/><circle cx=\"183\" cy=\"204\" r=\"31\" fill=\"#c97a3d\" stroke=\"#7d481e\" stroke-width=\"1\"\/><circle cx=\"267\" cy=\"204\" r=\"41\" fill=\"#2e9e44\" stroke=\"#161b20\" stroke-width=\"1.1\"\/><path d=\"M238 175 A 41 41 0 0 1 296 233 L 238 233 Z\" fill=\"#f2cf1d\"\/><circle cx=\"267\" cy=\"204\" r=\"41\" fill=\"none\" stroke=\"#161b20\" stroke-width=\"1.1\"\/><circle cx=\"267\" cy=\"204\" r=\"31\" fill=\"#c97a3d\" stroke=\"#7d481e\" stroke-width=\"1\"\/><line x1=\"267\" y1=\"120\" x2=\"472\" y2=\"42\" stroke=\"#16202b\" stroke-width=\"1.3\"\/><circle cx=\"267\" cy=\"120\" r=\"3\" fill=\"#16202b\"\/><circle cx=\"472\" cy=\"42\" r=\"14\" fill=\"#ffffff\" stroke=\"#16202b\" stroke-width=\"1.5\"\/><text x=\"472\" y=\"47\" text-anchor=\"middle\" font-size=\"13\" font-weight=\"700\" fill=\"#16202b\">1<\/text><line x1=\"301\" y1=\"120\" x2=\"504\" y2=\"92\" stroke=\"#16202b\" stroke-width=\"1.3\"\/><circle cx=\"301\" cy=\"120\" r=\"3\" fill=\"#16202b\"\/><circle cx=\"504\" cy=\"92\" r=\"14\" fill=\"#ffffff\" stroke=\"#16202b\" stroke-width=\"1.5\"\/><text x=\"504\" y=\"97\" text-anchor=\"middle\" font-size=\"13\" font-weight=\"700\" fill=\"#16202b\">2<\/text><line x1=\"297\" y1=\"234\" x2=\"514\" y2=\"144\" stroke=\"#16202b\" stroke-width=\"1.3\"\/><circle cx=\"297\" cy=\"234\" r=\"3\" fill=\"#16202b\"\/><circle cx=\"514\" cy=\"144\" r=\"14\" fill=\"#ffffff\" stroke=\"#16202b\" stroke-width=\"1.5\"\/><text x=\"514\" y=\"149\" text-anchor=\"middle\" font-size=\"13\" font-weight=\"700\" fill=\"#16202b\">3<\/text><line x1=\"321\" y1=\"206\" x2=\"514\" y2=\"196\" stroke=\"#16202b\" stroke-width=\"1.3\"\/><circle cx=\"321\" cy=\"206\" r=\"3\" fill=\"#16202b\"\/><circle cx=\"514\" cy=\"196\" r=\"14\" fill=\"#ffffff\" stroke=\"#16202b\" stroke-width=\"1.5\"\/><text x=\"514\" y=\"201\" text-anchor=\"middle\" font-size=\"13\" font-weight=\"700\" fill=\"#16202b\">4<\/text><line x1=\"329\" y1=\"210\" x2=\"498\" y2=\"246\" stroke=\"#16202b\" stroke-width=\"1.3\"\/><circle cx=\"329\" cy=\"210\" r=\"3\" fill=\"#16202b\"\/><circle cx=\"498\" cy=\"246\" r=\"14\" fill=\"#ffffff\" stroke=\"#16202b\" stroke-width=\"1.5\"\/><text x=\"498\" y=\"251\" text-anchor=\"middle\" font-size=\"13\" font-weight=\"700\" fill=\"#16202b\">5<\/text><line x1=\"323\" y1=\"254\" x2=\"464\" y2=\"294\" stroke=\"#16202b\" stroke-width=\"1.3\"\/><circle cx=\"323\" cy=\"254\" r=\"3\" fill=\"#16202b\"\/><circle cx=\"464\" cy=\"294\" r=\"14\" fill=\"#ffffff\" stroke=\"#16202b\" stroke-width=\"1.5\"\/><text x=\"464\" y=\"299\" text-anchor=\"middle\" font-size=\"13\" font-weight=\"700\" fill=\"#16202b\">6<\/text><\/svg><figcaption>Cross-sectional structure of the 2YSLCYK-J 0.6\/1 kV 4\u00d7120 mm\u00b2 double-screened VFD motor cable (numbered layers listed below).<\/figcaption><ol class=\"tbf-list\"><li>Class 5 finely stranded bare copper conductors (4 \u00d7 120 mm\u00b2 \u2264 0.161 \u03a9\/km; 4 \u00d7 35 mm\u00b2 \u2264 0.554 \u03a9\/km at 20 \u00b0C per IEC 60228)<\/li><li>Low-capacitance polyethylene (PE, 2Y) core insulation identified brown, black, grey and green-yellow per HD 308 S2 \/ VDE 0293-308<\/li><li>Concentric core lay wrapped in polyester separator tape to preserve circular geometry<\/li><li>First EMC screen: overlapping aluminium-laminated composite foil applied with the metallic surface facing outward<\/li><li>Second EMC screen: tinned-copper wire braid in continuous contact with the foil for low high-frequency transfer impedance<\/li><li>Black RAL 9005 UV-, weather- and oil-resistant special PVC outer sheath (4 kV AC \/ 5 min routine test)<\/li><\/ol><\/figure>\n<p>In the <code>2YSLCYK-J<\/code> build, each layer solves a distinct part of the inverter duty cycle:<\/p><ul class=\"tbf-list\"><li><strong>Class 5 bare copper flexibility (<a href=\"https:\/\/webstore.iec.ch\/en\/publication\/71891\" rel=\"nofollow noopener\" target=\"_blank\">IEC 60228<\/a>):<\/strong> Finely stranded bare copper (<a href=\"https:\/\/tebaoflex-cable.com\/conductor-stranding-classes\/\">conductor stranding Class 5<\/a>) routes around tight switchgear plinths and pump bases at 10 \u00d7 D fixed bending radius without solid-core springback.<\/li><li><strong>Polyethylene (2Y) low-loss dielectric:<\/strong> PE provides \u2265 20 M\u03a9\u00b7km insulation resistance at 20 \u00b0C and low dielectric loss, curbing reflected-wave voltage overshoot on longer converter-to-motor runs.<\/li><li><strong>Aluminium-laminated foil + tinned-copper braid:<\/strong> Placing the metal side of the aluminium composite tape outward in direct contact with an oxidation-resistant <a href=\"https:\/\/tebaoflex-cable.com\/tinned-copper-vs-bare-copper\/\">tinned-copper<\/a> braid combines full-circumference foil high-frequency screening with a low-resistance metallic fault and drain path.<\/li><\/ul>\n<div class=\"tbf-shots\">\n<figure><img loading=\"lazy\" src=\"https:\/\/tebaoflex-cable.com\/wp-content\/uploads\/2026\/11\/2yslcyk-j-4x120-pe-insulation-double-screen-cross-section.webp\" alt=\"Cross-section of 2YSLCYK-J 0.6\/1 kV 4\u00d7120 mm\u00b2 showing Class 5 bare copper conductors, brown\/black\/grey\/green-yellow PE insulation, aluminium-laminated foil plus tinned-copper braid double screen and black PVC outer sheath\" width=\"1200\" height=\"900\" loading=\"lazy\" decoding=\"async\"><figcaption>Saw-cut cross-section of the finished 2YSLCYK-J 4\u00d7120 mm\u00b2 cable showing the concentric brown, black, grey and green-yellow PE cores surrounded by the foil-and-braid screen.<\/figcaption><\/figure>\n<figure><img loading=\"lazy\" src=\"https:\/\/tebaoflex-cable.com\/wp-content\/uploads\/2026\/11\/2yslcyk-j-4x120-aluminium-laminated-foil-tinned-copper-braid-inspection.webp\" alt=\"Opened inspection sample of the 2YSLCYK-J 4\u00d7120 mm\u00b2 cable displaying the black PVC sheath ring, four low-capacitance PE core rings and the aluminium-laminated foil plus tinned-copper wire braid double screen\" width=\"1200\" height=\"900\" loading=\"lazy\" decoding=\"async\"><figcaption>Pre-shipment peel-back verification requested by the Singapore buyer: opened layers confirming the white\/metallic aluminium-laminated foil wrap beneath the tinned-copper wire braid and black PVC outer sheath.<\/figcaption><\/figure>\n<\/div>\n<h2 id=\"electrical-and-dimensional-data\">2YSLCYK-J 4\u00d7120 mm\u00b2 and 4\u00d735 mm\u00b2 electrical and dimensional data<\/h2>\n<p class=\"tbf-answer\">The Singapore order paired heavy 4 \u00d7 120 mm\u00b2 main pump feeders (\u2264 0.161 \u03a9\/km at 20 \u00b0C, ~292 A at 30 \u00b0C in free air, 5,556.8 kg\/km) with 4 \u00d7 35 mm\u00b2 auxiliary fan feeders (\u2264 0.554 \u03a9\/km, ~135 A, 1,817.3 kg\/km), both routine-tested at 4 kV AC for 5 minutes.<\/p>\n<div class=\"tbf-tw\"><table class=\"tbf-wide\"><caption>Technical schedule for the 2YSLCYK-J 0.6\/1 kV 4\u00d7120 mm\u00b2 and 4\u00d735 mm\u00b2 data center VFD motor cables (DIN VDE 0250 \/ IEC 60502-1 reference)<\/caption><thead><tr><th scope=\"col\">Configuration<\/th><th scope=\"col\">Outer \u00d8 (mm)<\/th><th scope=\"col\">Cu index (kg\/km)<\/th><th scope=\"col\">Total mass (kg\/km)<\/th><th scope=\"col\">Ref. current 30 \u00b0C<\/th><th scope=\"col\">Max R20 (IEC 60228)<\/th><th scope=\"col\">Routine test<\/th><\/tr><\/thead><tbody>\n<tr><th scope=\"row\">2YSLCYK-J 4 \u00d7 120 mm\u00b2<\/th><td>51.9 nominal (49.12 caliper)<\/td><td>4,287.6<\/td><td>5,556.8<\/td><td>Approx. 292 A<\/td><td>\u2264 0.161 \u03a9\/km<\/td><td>4 kV AC \/ 5 min<\/td><\/tr>\n<tr><th scope=\"row\">2YSLCYK-J 4 \u00d7 35 mm\u00b2<\/th><td>32.7 nominal<\/td><td>1,245.7<\/td><td>1,817.3<\/td><td>Approx. 135 A<\/td><td>\u2264 0.554 \u03a9\/km<\/td><td>4 kV AC \/ 5 min<\/td><\/tr>\n<\/tbody><\/table><\/div>\n<p><strong>Engineering selection note \u2014 4-core <code>2YSLCYK-J<\/code> vs. symmetrical <code>3+3<\/code> <code>2YSLCYK-JB<\/code>:<\/strong> Four-core concentric <code>2YSLCYK-J<\/code> provides a full-sized green-yellow earth core alongside L1\/L2\/L3, matching four-pole gland plates and Singapore conduit schedules. When a drive manufacturer specifies symmetrical split-earth geometry above 35 mm\u00b2 to minimize shaft voltages on uninsulated motor bearings, specify the <code>3+3<\/code> construction listed on our <a href=\"https:\/\/tebaoflex-cable.com\/product\/2yslcyk-jb-symmetrical-vfd-cable\/\">2YSLCYK-JB 0.6\/1 kV symmetrical VFD cable product page<\/a> (for example <code>3\u00d7120 + 3G16 mm\u00b2<\/code> at 47.8 mm nominal OD). For heavy mobile mining or reeling drives requiring elastomeric abrasion resistance instead of fixed PVC conduit routing, compare our <a href=\"https:\/\/tebaoflex-cable.com\/product\/nsshcoeu-cable\/\">(N)SSHCOEU 0.6\/1 kV rubber EMC VFD cable<\/a>.<\/p>\n<h2 id=\"conduit-od-and-preshipment-verification\">Pre-shipment hold points: rigid conduit OD check, sheath marking and container loading<\/h2>\n<p class=\"tbf-answer\">Because the Singapore contractor pulls the 4 \u00d7 120 mm\u00b2 VFD cable inside fixed rigid tubes, the buyer instituted four pre-shipment hold points: digital caliper OD verification (49.12 mm), peeled aluminium-foil confirmation, sheath print approval and IPPC export container loading inspection.<\/p>\n<p>Before authorizing ocean dispatch from Shanghai to Singapore, the buyer&#8217;s engineering team reviewed photographic evidence across four production checkpoints aligned with our <a href=\"https:\/\/tebaoflex-cable.com\/cable-factory-acceptance-test\/\">cable factory acceptance test workflow<\/a> and <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/64963\" rel=\"nofollow noopener\" target=\"_blank\">IEC 60502-1<\/a> dimensional discipline:<\/p><ol class=\"tbf-list\"><li><strong>Conduit outside-diameter check:<\/strong> An oversized jacket jams inside conduit bends, while an undersized jacket fails EMC gland clamping ranges. Factory digital calipers measured <strong>49.12 mm<\/strong> on the 4 \u00d7 120 mm\u00b2 run\u2014cleanly within the approved 51.9 mm nominal conduit envelope.<\/li><li><strong>Sheath marking verification:<\/strong> High-contrast white meter-marked legend on the black RAL 9005 UV\/oil-resistant PVC sheath (<code>4Cx120MM2 600\/1000V DIN VDE Standard 2026<\/code>) was verified prior to spooling.<\/li><li><strong>Double-screen peel inspection:<\/strong> Opening a cut sample confirmed both the aluminium-laminated foil (metal side out) and tinned-copper wire braid were applied over the polyester-wrapped PE cores.<\/li><li><strong>Moisture-sealed IPPC drum &amp; container bracing:<\/strong> Cable ends were sealed with heat-shrink caps, lashed inside steel-hubbed IPPC heat-treated wooden drums, fully lagged with wooden battens and chocked inside the sea container.<\/li><\/ol>\n<div class=\"tbf-shots\">\n<figure><img loading=\"lazy\" src=\"https:\/\/tebaoflex-cable.com\/wp-content\/uploads\/2026\/11\/2yslcyk-j-4x120-caliper-49-12mm-conduit-clearance-check.webp\" alt=\"Digital caliper recording 49.12 mm finished outside diameter on the 2YSLCYK-J 4\u00d7120 mm\u00b2 VFD cable (51.9 mm nominal design) to verify clearance for Singapore data center conduit installation\" width=\"1200\" height=\"900\" loading=\"lazy\" decoding=\"async\"><figcaption>Digital caliper confirming 49.12 mm finished outside diameter on the 2YSLCYK-J 4\u00d7120 mm\u00b2 cable for rigid tube\/conduit installation in Singapore.<\/figcaption><\/figure>\n<figure><img loading=\"lazy\" src=\"https:\/\/tebaoflex-cable.com\/wp-content\/uploads\/2026\/11\/2yslcyk-j-4cx120mm2-600-1000v-sheath-print-verification.webp\" alt=\"Clear sheath print on the TEBAOFLEX 2YSLCYK-J 4C\u00d7120 mm\u00b2 600\/1000 V DIN VDE reference VFD motor cable inspected prior to export packing\" width=\"1200\" height=\"900\" loading=\"lazy\" decoding=\"async\"><figcaption>Pre-shipment sheath print check verifying crisp 4C\u00d7120 mm\u00b2 600\/1000 V identification and sequential meter markings on the black RAL 9005 PVC jacket.<\/figcaption><\/figure>\n<\/div>\n<div class=\"tbf-shots\">\n<figure><img loading=\"lazy\" src=\"https:\/\/tebaoflex-cable.com\/wp-content\/uploads\/2026\/11\/2yslcyk-j-vfd-cable-moisture-sealed-end-cap-wooden-drum.webp\" alt=\"Heat-shrink moisture-sealed cable end lashed inside the steel-reinforced wooden export drum flange before wooden batten lagging\" width=\"1200\" height=\"900\" loading=\"lazy\" decoding=\"async\"><figcaption>Heat-shrink moisture-sealed cable end tied inside the wooden drum flange to prevent tropical humidity ingress during sea transit.<\/figcaption><\/figure>\n<figure><img loading=\"lazy\" src=\"https:\/\/tebaoflex-cable.com\/wp-content\/uploads\/2026\/11\/2yslcyk-j-4x120-ippc-heat-treated-lagged-export-drum.webp\" alt=\"Fully lagged IPPC heat-treated wooden export drum of 2YSLCYK-J 0.6\/1 kV double-screened VFD motor cable ready for Singapore sea container loading\" width=\"1200\" height=\"900\" loading=\"lazy\" decoding=\"async\"><figcaption>Completed IPPC heat-treated wooden export drum fully enclosed in protective wooden battens at the TEBAOFLEX Taicang yard.<\/figcaption><\/figure>\n<\/div>\n<figure class=\"tbf-fig\"><img loading=\"lazy\" src=\"https:\/\/tebaoflex-cable.com\/wp-content\/uploads\/2026\/11\/2yslcyk-j-vfd-cable-wooden-drum-loaded-in-sea-container.webp\" alt=\"Lagged wooden export drum of TEBAOFLEX 2YSLCYK-J 0.6\/1 kV VFD cable chocked inside the ocean shipping container for dispatch to Singapore\" width=\"900\" height=\"675\" loading=\"lazy\" decoding=\"async\"><figcaption>Lagged wooden export drum of 2YSLCYK-J 0.6\/1 kV VFD motor cable loaded and timber-chocked inside the sea container for shipment to Singapore.<\/figcaption><\/figure>\n<p id=\"tbf-b6-donor-8527\">Compare fixed PE 2YSLCYK-J and 3+3 symmetrical 2YSLCYK-JB directly against dynamic rubber (N)SSHCOEU, (N)SSCH\u00d6U-J and 2 kV mining VFD cables\u2014including 30 MHz transfer impedance and 360-degree EMC compression gland rules\u2014in our <a href=\"https:\/\/tebaoflex-cable.com\/double-screened-vfd-cable-2yslcyk-emc-termination-guide\/\">double-screened VFD cable selection and EMC termination guide<\/a>.<\/p>\n<h2 id=\"rfq-checklist\">What to specify when ordering 2YSLCYK-J or 2YSLCYK-JB VFD cables<\/h2>\n<p class=\"tbf-answer\">To receive an accurate VFD motor cable quotation and conduit-clearance datasheet, confirm whether your gland schedule requires 4-core concentric 2YSLCYK-J or 3+3 symmetrical 2YSLCYK-JB, state conduit inside diameter and route length, and specify cut drum lengths.<\/p>\n<div class=\"tbf-need\"><strong>Send these project parameters for an engineering review before quotation:<\/strong>\n<ul>\n<li>Core configuration: 4-core concentric 2YSLCYK-J (such as 4\u00d735 or 4\u00d7120 mm\u00b2) vs. 3+3 symmetrical 2YSLCYK-JB (such as 3\u00d7120+3G16 mm\u00b2)<\/li>\n<li>Inverter kW\/ampere rating, switching carrier frequency, total motor run length (for dV\/dt or reactor review) and ambient grouping temperature<\/li>\n<li>Installation route constraints: rigid conduit\/tube inner diameter, EMC brass\/stainless cable gland clamping range and indoor\/outdoor UV exposure<\/li>\n<li>Required drum cut lengths, sheath print wording and destination port packing rules (such as IPPC heat-treated lagged wooden drums)<\/li>\n<\/ul>\n<p>TEBAOFLEX manufactures custom 2YSLCYK-J and 2YSLCYK-JB double-screened VFD motor cables from a 50 m minimum order quantity, with a standard manufacturing lead time of 7 to 45 working days as of November 2026 depending on cross-section and order schedule. Browse our full <a href=\"https:\/\/tebaoflex-cable.com\/products\/industrial-cables\/\">industrial and flexible cables<\/a> range for related EMC and automation feeders.<\/p><\/div>\n<p><a class=\"tbf-cta\" href=\"https:\/\/tebaoflex-cable.com\/contact-us\/#request-quote\">Request a 2YSLCYK-J \/ 2YSLCYK-JB VFD cable quote &amp; datasheet &rarr;<\/a><\/p>\n<h2 id=\"faq\">Frequently asked questions on 2YSLCYK-J 0.6\/1 kV VFD motor cables<\/h2>\n<div class=\"tbf-faq\">\n<details><summary>What does 2YSLCYK-J stand for on a 0.6\/1 kV VFD motor cable?<\/summary><p>In German DIN VDE-pattern VFD nomenclature, 2Y denotes low-capacitance polyethylene (PE) core insulation, SL designates a flexible motor control\/power construction, C indicates a concentric metallic screen (aluminium-laminated foil plus tinned-copper braid), YK denotes a black UV-resistant PVC outer sheath (K = black outdoor grade), and -J confirms an included green-yellow protective-earth conductor.<\/p><\/details>\n<details><summary>Why did the Singapore compute data center require low-capacitance PE insulation instead of PVC on VFD feeders?<\/summary><p>Pulse-width-modulated (PWM) frequency converters driving chilled-water pumps and cooling fans switch IGBTs at multi-kilohertz carrier frequencies. Polyethylene (2Y) has roughly half the relative permittivity of PVC, cutting cable-to-screen capacitive charging spikes, bearing currents and converter overcurrent trips on long data-center motor runs.<\/p><\/details>\n<details><summary>Why was finished outside diameter verification critical for the 4\u00d7120 mm\u00b2 order?<\/summary><p>Before release for shipment, the Singapore engineering team specified that the 4\u00d7120 mm\u00b2 cable could not exceed its standard design envelope because the feeder pulls inside fixed rigid conduits at the data center. Factory digital calipers recorded 49.12 mm against the 51.9 mm nominal reference, confirming smooth conduit clearance and 10 \u00d7 D fixed bend compliance.<\/p><\/details>\n<details><summary>When should 4-core 2YSLCYK-J be selected versus 3+3 symmetrical 2YSLCYK-JB?<\/summary><p>Four-core concentric 2YSLCYK-J (such as 4\u00d735 mm\u00b2 and 4\u00d7120 mm\u00b2) matches terminal lug blocks and conduit schedules designed for four equal conductors (L1, L2, L3, PE). Above 35\u201350 mm\u00b2 on high-carrier-frequency drives where minimal common-mode shaft voltage is required, 3+3 symmetrical 2YSLCYK-JB (three phases plus three split interstitial earth cores) further balances magnetic flux.<\/p><\/details>\n<details><summary>How should the double screen on 2YSLCYK-J be terminated at the inverter and motor?<\/summary><p>Both the aluminium-laminated foil and the tinned-copper braid must be bonded 360 degrees around the circumference at both the frequency converter cabinet and the AC motor terminal box using EMC compression glands or earthing clamps\u2014never twisted into a long single pigtail, which adds high-frequency inductance and degrades EMC shielding.<\/p><\/details>\n<\/div>\n<div class=\"tbf-byline\">Project record prepared by <a href=\"https:\/\/tebaoflex-cable.com\/author\/zheng-lipeng\/\">Zheng LiPeng<\/a>, Manager, with the TEBAOFLEX cable engineering team in Taicang, Jiangsu \u00b7 Published <time datetime=\"2026-11-18\">18 November 2026<\/time>. More about our manufacturing and testing facilities on our <a href=\"https:\/\/tebaoflex-cable.com\/about-us\/\">about us page<\/a>.<\/div>\n<div class=\"tbf-back\"><a href=\"https:\/\/tebaoflex-cable.com\/cases\/\">&larr; Back to all industrial cable application cases<\/a><\/div>\n<\/div>\n\n<script type=\"application\/ld+json\">{\"@context\": \"https:\/\/schema.org\", \"@type\": \"Article\", \"headline\": \"2YSLCYK-J 0.6\/1 kV 4\u00d7120 & 4\u00d735 mm\u00b2 Double-Screened VFD Motor Cable for a Compute Data Center in Singapore\", \"description\": \"Case: 2YSLCYK-J 0.6\/1 kV 4\u00d7120 and 4\u00d735 mm\u00b2 low-capacitance PE double-screened VFD motor cable for a Singapore data center \u2014 49.12 mm conduit fit.\", \"mainEntityOfPage\": {\"@type\": \"WebPage\", \"@id\": \"https:\/\/tebaoflex-cable.com\/cases\/2yslcyk-j-0-6-1kv-4x120-vfd-motor-cable-data-center-singapore\/\"}, \"url\": \"https:\/\/tebaoflex-cable.com\/cases\/2yslcyk-j-0-6-1kv-4x120-vfd-motor-cable-data-center-singapore\/\", \"inLanguage\": \"en\", \"image\": [{\"@type\": \"ImageObject\", \"url\": \"https:\/\/tebaoflex-cable.com\/wp-content\/uploads\/2026\/11\/2yslcyk-j-0-6-1kv-4x120-vfd-motor-cable-singapore-hero.webp\", \"width\": 1200, \"height\": 900}, {\"@type\": \"ImageObject\", \"url\": \"https:\/\/tebaoflex-cable.com\/wp-content\/uploads\/2026\/11\/2yslcyk-j-4x120-aluminium-laminated-foil-tinned-copper-braid-inspection.webp\", \"width\": 1200, \"height\": 900}, {\"@type\": \"ImageObject\", \"url\": \"https:\/\/tebaoflex-cable.com\/wp-content\/uploads\/2026\/11\/2yslcyk-j-4x120-caliper-49-12mm-conduit-clearance-check.webp\", \"width\": 1200, \"height\": 900}], \"author\": {\"@type\": \"Person\", \"@id\": \"https:\/\/tebaoflex-cable.com\/author\/zheng-lipeng\/\", \"name\": \"Zheng LiPeng\", \"url\": \"https:\/\/tebaoflex-cable.com\/author\/zheng-lipeng\/\", \"jobTitle\": \"Manager\", \"image\": \"https:\/\/tebaoflex-cable.com\/wp-content\/uploads\/2026\/09\/tebaoflex-author-headshot-100x100.jpg\", \"sameAs\": [\"https:\/\/www.linkedin.com\/in\/tebaoflexcable\/\"], \"worksFor\": {\"@id\": \"https:\/\/tebaoflex-cable.com\/#organization\"}}, \"publisher\": {\"@type\": \"Organization\", \"@id\": \"https:\/\/tebaoflex-cable.com\/#organization\", \"name\": \"TEBAOFLEX\", \"url\": \"https:\/\/tebaoflex-cable.com\/\"}, \"about\": [\"2YSLCYK-J 0.6\/1 kV VFD motor cable\", \"Double-screened low-capacitance PE inverter cable\", \"Data center EMC motor feeder\"], \"datePublished\": \"2026-11-18\", \"dateModified\": \"2026-11-18\"}<\/script>\n<script type=\"application\/ld+json\">{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What does 2YSLCYK-J stand for on a 0.6\/1 kV VFD motor cable?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"In German DIN VDE-pattern VFD nomenclature, 2Y denotes low-capacitance polyethylene (PE) core insulation, SL designates a flexible motor control\/power construction, C indicates a concentric metallic screen (aluminium-laminated foil plus tinned-copper braid), YK denotes a black UV-resistant PVC outer sheath (K = black outdoor grade), and -J confirms an included green-yellow protective-earth conductor.\"}}, {\"@type\": \"Question\", \"name\": \"Why did the Singapore compute data center require low-capacitance PE insulation instead of PVC on VFD feeders?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Pulse-width-modulated (PWM) frequency converters driving chilled-water pumps and cooling fans switch IGBTs at multi-kilohertz carrier frequencies. Polyethylene (2Y) has roughly half the relative permittivity of PVC, cutting cable-to-screen capacitive charging spikes, bearing currents and converter overcurrent trips on long data-center motor runs.\"}}, {\"@type\": \"Question\", \"name\": \"Why was finished outside diameter verification critical for the 4\u00d7120 mm\u00b2 order?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Before release for shipment, the Singapore engineering team specified that the 4\u00d7120 mm\u00b2 cable could not exceed its standard design envelope because the feeder pulls inside fixed rigid conduits at the data center. Factory digital calipers recorded 49.12 mm against the 51.9 mm nominal reference, confirming smooth conduit clearance and 10 \u00d7 D fixed bend compliance.\"}}, {\"@type\": \"Question\", \"name\": \"When should 4-core 2YSLCYK-J be selected versus 3+3 symmetrical 2YSLCYK-JB?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Four-core concentric 2YSLCYK-J (such as 4\u00d735 mm\u00b2 and 4\u00d7120 mm\u00b2) matches terminal lug blocks and conduit schedules designed for four equal conductors (L1, L2, L3, PE). Above 35\u201350 mm\u00b2 on high-carrier-frequency drives where minimal common-mode shaft voltage is required, 3+3 symmetrical 2YSLCYK-JB (three phases plus three split interstitial earth cores) further balances magnetic flux.\"}}, {\"@type\": \"Question\", \"name\": \"How should the double screen on 2YSLCYK-J be terminated at the inverter and motor?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Both the aluminium-laminated foil and the tinned-copper braid must be bonded 360 degrees around the circumference at both the frequency converter cabinet and the AC motor terminal box using EMC compression glands or earthing clamps\u2014never twisted into a long single pigtail, which adds high-frequency inductance and degrades EMC shielding.\"}}]}<\/script>\n","protected":false},"excerpt":{"rendered":"<p>Fallstudie: Doppelt geschirmte kapazit\u00e4tsarme PE-Frequenzumrichter-Motorleitung 2YSLCYK-J 0.6\/1 kV 4\u00d7120 und 4\u00d735 mm\u00b2 f\u00fcr ein Rechenzentrum in Singapur \u2014 49.12 mm Schutzrohr-Passma\u00df.<\/p>","protected":false},"author":1,"featured_media":8508,"parent":3117,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-8527","page","type-page","status-publish","has-post-thumbnail","hentry"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/tebaoflex-cable.com\/de\/wp-json\/wp\/v2\/pages\/8527","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/tebaoflex-cable.com\/de\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/tebaoflex-cable.com\/de\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/tebaoflex-cable.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/tebaoflex-cable.com\/de\/wp-json\/wp\/v2\/comments?post=8527"}],"version-history":[{"count":2,"href":"https:\/\/tebaoflex-cable.com\/de\/wp-json\/wp\/v2\/pages\/8527\/revisions"}],"predecessor-version":[{"id":8710,"href":"https:\/\/tebaoflex-cable.com\/de\/wp-json\/wp\/v2\/pages\/8527\/revisions\/8710"}],"up":[{"embeddable":true,"href":"https:\/\/tebaoflex-cable.com\/de\/wp-json\/wp\/v2\/pages\/3117"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/tebaoflex-cable.com\/de\/wp-json\/wp\/v2\/media\/8508"}],"wp:attachment":[{"href":"https:\/\/tebaoflex-cable.com\/de\/wp-json\/wp\/v2\/media?parent=8527"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}