{"id":8528,"date":"2026-11-18T13:19:37","date_gmt":"2026-11-18T05:19:37","guid":{"rendered":"https:\/\/tebaoflex-cable.com\/cases\/shd-gc-8kv-3x4-0-awg-mining-cable-peru\/"},"modified":"2026-11-18T13:19:37","modified_gmt":"2026-11-18T05:19:37","slug":"shd-gc-8kv-3x4-0-awg-mining-cable-peru","status":"publish","type":"page","link":"https:\/\/tebaoflex-cable.com\/de\/cases\/shd-gc-8kv-3x4-0-awg-mining-cable-peru\/","title":{"rendered":"Bergbau-Starkstromleitung SHD-GC 8 kV 3\u00d74\/0+2\u00d71+1\u00d78 AWG Klasse 6 (200 m) f\u00fcr Peru"},"content":{"rendered":"\n<style>\n.tbf-case-pg{max-width:960px;margin-left:auto;margin-right:auto;--ink:#16202b;--muted:#5b6b7c;--line:#e2e8ee;--accent:#b4381f;--soft:#f6f8fa;color:var(--ink);line-height:1.7;font-size:17px}\n.tbf-case-pg h1{font-size:2rem;line-height:1.2;margin:0 0 .6rem}\n.tbf-case-pg h2{font-size:1.5rem;margin:2.4rem 0 .5rem;border-top:3px solid var(--ink);padding-top:.5rem}\n.tbf-case-pg h3{font-size:1.08rem;margin:1.4rem 0 .3rem}\n.tbf-case-pg p{margin:0 0 1rem}\n.tbf-case-pg a{color:var(--accent);text-underline-offset:2px}\n.tbf-kicker{font-size:.75rem;letter-spacing:.1em;text-transform:uppercase;font-weight:700;color:#1f7a5c;margin-bottom:.4rem}\n.tbf-lede{font-size:1.1rem;color:var(--muted)}\n.tbf-case-pg table{width:100%;border-collapse:collapse;margin:1.1rem 0;font-size:.96rem}\n.tbf-case-pg th,.tbf-case-pg td{border:1px solid var(--line);padding:.55rem .75rem;text-align:left;vertical-align:top}\n.tbf-case-pg th{background:var(--soft);width:34%;font-weight:700}\n.tbf-wide{min-width:620px}\n.tbf-wide th{width:auto}\n.tbf-tw{overflow-x:auto}\n.tbf-hero{margin:1.3rem 0 .3rem}\n.tbf-hero img{width:100%;height:auto;display:block;border-radius:10px;border:1px solid var(--line);background:#fff}\n.tbf-hero figcaption,.tbf-fig figcaption{font-size:.85rem;color:var(--muted);margin-top:.4rem}\n.tbf-fig{margin:1.4rem 0}\n.tbf-fig img{width:100%;max-width:520px;height:auto;display:block;margin:0 auto;border-radius:10px;border:1px solid var(--line);background:#fff}\n.tbf-shots{display:grid;grid-template-columns:1fr 1fr;gap:1rem;margin:1.4rem 0}\n.tbf-shots figure{margin:0}\n.tbf-shots img{width:100%;height:360px;object-fit:contain;background:#fff;border-radius:10px;border:1px solid var(--line);display:block}\n.tbf-shots figcaption{font-size:.85rem;color:var(--muted);margin-top:.4rem}\n.tbf-scope{border:1px dashed var(--line);border-radius:8px;padding:.85rem 1.1rem;margin:1.2rem 0;font-size:.92rem;color:var(--muted);background:var(--soft)}\n.tbf-eng{background:var(--soft);border-left:3px solid var(--ink);padding:.2rem 1.1rem .6rem;margin:1.2rem 0;border-radius:0 8px 8px 0}\n.tbf-eng .tag{display:inline-block;font-size:.7rem;letter-spacing:.09em;text-transform:uppercase;font-weight:700;color:var(--muted);margin:.9rem 0 .2rem}\n.tbf-need{background:#fdf6f4;border-left:3px solid var(--accent);padding:.9rem 1.1rem;margin:1.2rem 0;border-radius:0 8px 8px 0}\n.tbf-need ul{margin:.4rem 0 0;padding-left:1.1rem;columns:2;column-gap:2rem}\n.tbf-need li{margin:.2rem 0;break-inside:avoid}\n.tbf-rel ul{padding-left:1.1rem;columns:2;column-gap:2rem}\n.tbf-rel li{margin:.22rem 0;break-inside:avoid}\n.tbf-faq details{border-bottom:1px solid var(--line);padding:.8rem 0}\n.tbf-faq summary{cursor:pointer;font-weight:600}\n.tbf-faq p{margin:.55rem 0 0;color:var(--muted)}\n.tbf-cta{display:inline-block;background:var(--accent);color:#fff!important;text-decoration:none!important;border-radius:8px;padding:.6rem 1.15rem;font-weight:600;margin-top:.5rem}\n.tbf-byline{font-size:.92rem;color:var(--muted);background:var(--soft);border-radius:8px;padding:.85rem 1.1rem;margin:1.6rem 0}\n.tbf-back{font-size:.9rem;margin-top:2rem;padding-top:1rem;border-top:1px solid var(--line)}\n@media(max-width:640px){.tbf-shots{grid-template-columns:1fr}.tbf-need ul,.tbf-rel ul{columns:1}.tbf-case-pg th{width:auto}}\n.tbf-case-pg caption{caption-side:top;text-align:left;font-weight:700;font-size:.95rem;color:var(--ink);margin-bottom:.45rem}.tbf-case-pg ul.tbf-list,.tbf-case-pg ol.tbf-list{padding-left:1.2rem;margin:0 0 1rem}.tbf-case-pg .tbf-list li{margin:.3rem 0}.tbf-case-pg .tbf-answer{font-size:1.04rem;border-left:3px solid #1f7a5c;padding:.1rem 0 .1rem .9rem}.tbf-sys{width:100%;max-width:680px;height:auto;display:block;margin:0 auto}.tbf-diag{margin:1.4rem 0}.tbf-diag ol{padding-left:1.4rem;font-size:.95rem;columns:2;column-gap:2rem}.tbf-diag li{margin:.2rem 0;break-inside:avoid}.tbf-diag figcaption{font-size:.85rem;color:var(--muted);margin-top:.4rem}@media(max-width:640px){.tbf-shots{grid-template-columns:1fr}.tbf-shots img{height:auto}.tbf-diag ol{columns:1}}\n<\/style>\n<div class=\"tbf-case-pg\">\n<p class=\"tbf-kicker\">Case 22 \u00b7 Peru \u00b7 Mine Power Distribution \u00b7 8 kV SHD-GC Class 6 Trailing Cable<\/p>\n<h1>SHD-GC 8 kV 3\u00d74\/0+2\u00d71+1\u00d78 AWG Class 6 Mining Power Cable (200 m) for Peru<\/h1>\n<p class=\"tbf-lede\">Peruvian copper and polymetallic mines standardize on ANSI\/ICEA S-75-381 Type SHD-GC shielded trailing cables for mobile shovels, drills and pit skid substations, yet frequently order in metric drum lengths with custom core identification and Spanish sheath legends. Following an on-site factory visit by the buyer&#8217;s inspection representative in Taicang, TEBAOFLEX manufactured and factory-tested an initial 200 m continuous drum of SHD-GC 8 kV 3\u00d74\/0 AWG + 2\u00d71 AWG + 1\u00d78 AWG built with Class 6 extra-flexible tinned copper, orange-red 150 mil EPR insulation and a 250 mil heavy-duty black jacket.<\/p>\n<figure class=\"tbf-hero\"><img fetchpriority=\"high\" src=\"https:\/\/tebaoflex-cable.com\/wp-content\/uploads\/2026\/11\/shd-gc-8kv-3x4-0-awg-2x1-1x8-mining-cable-peru-hero.webp\" alt=\"Angled cut end of the TEBAOFLEX SHD-GC 8 kV 3\u00d74\/0 AWG + 2\u00d71 AWG + 1\u00d78 AWG mining power cable built for Peru showing orange-red 150 mil EPR insulation, semiconductive and copper braid shields, two 1 AWG ground conductors, yellow 8 AWG ground-check core and 250 mil black jacket\" width=\"1200\" height=\"900\" fetchpriority=\"high\" decoding=\"async\" data-no-lazy=\"1\"><figcaption>Cut end of the 200 m TEBAOFLEX SHD-GC 8 kV 3\u00d74\/0+2\u00d71+1\u00d78 AWG Class 6 mining power cable manufactured for Peru: three orange-red 150 mil EPR phase cores with semiconductive and tinned-copper braid shields, two 1 AWG ground conductors, yellow 8 AWG ground-check core and 250 mil black CPE outer jacket.<\/figcaption><\/figure>\n<h2 id=\"project-at-a-glance\">Project at a glance<\/h2>\n<p class=\"tbf-answer\">This Peruvian mining supply order produced a 200 m continuous drum of SHD-GC 8 kV 3\u00d74\/0 + 2\u00d71 + 1\u00d78 AWG (ICEA S-75-381) with Class 6 tinned copper, recording 0.17360 \u03a9\/km 20 \u00b0C phase DC resistance, 70.94 mm finished caliper diameter (against 69.9 mm nominal) and 321 A 40 \u00b0C free-air rating.<\/p>\n<div class=\"tbf-tw\"><table><caption>Summary of the Peru SHD-GC 8 kV 3\u00d74\/0+2\u00d71+1\u00d78 AWG Class 6 mining power cable order<\/caption><thead><tr><th scope=\"col\">Order item<\/th><th scope=\"col\">Verified engineering detail<\/th><\/tr><\/thead><tbody>\n<tr><th scope=\"row\">Destination &#038; buyer profile<\/th><td>Peru \u2014 mining electrical distributor supplying open-pit and underground mine operations<\/td><\/tr>\n<tr><th scope=\"row\">Cable designation &#038; standard<\/th><td>Type SHD-GC 8 kV 3\u00d74\/0 AWG + 2\u00d71 AWG + 1\u00d78 AWG, built to ANSI\/ICEA S-75-381 (formerly NEMA WC 58)<\/td><\/tr>\n<tr><th scope=\"row\">Order quantity &#038; follow-on<\/th><td>200 m continuous uncut first drum (~20-day production run; 500 m repeat inquiry under review)<\/td><\/tr>\n<tr><th scope=\"row\">Conductor stranding<\/th><td>Class 6 extra-flexible annealed tinned copper across phases, grounds and ground-check<\/td><\/tr>\n<tr><th scope=\"row\">Dielectric &#038; colour code<\/th><td>150 mil (3.8 mm) nominal 90 \u00b0C orange-red EPR phase insulation + semiconductive\/copper-braid phase shields; yellow 8 AWG GC<\/td><\/tr>\n<tr><th scope=\"row\">Outer jacket &#038; Spanish print<\/th><td>250 mil (6.4 mm) black extra-heavy-duty CPE jacket printed every metre: TEBAOFLEX TRIPOLAR SHD-GC 8kV 3&#215;4\/0AWG+2x1AWG+1x8AWG ICEA S-75-381 Standard 2026<\/td><\/tr>\n<tr><th scope=\"row\">Verified factory test readings<\/th><td>Phase R20 = 173.60 m\u03a9\/km (0.17360 \u03a9\/km); 8 AWG GC R20 = 2,153.9 m\u03a9\/km; finished caliper OD = 70.94 mm (nominal 2.75 in \/ 69.9 mm)<\/td><\/tr>\n<tr><th scope=\"row\">Packing &#038; trade basis<\/th><td>Wound with moisture-sealed ends onto a lagged wooden export drum for FOB Shanghai sea dispatch with Certificate of Quality (COQ)<\/td><\/tr>\n<\/tbody><\/table><\/div>\n<div class=\"tbf-scope\"><strong>Scope note.<\/strong> This engineering record covers the 200 m Taicang factory build, Class 6 stranding selection, Kelvin bridge and caliper inspection data, and 8 kV ampacity verification prior to FOB Shanghai dispatch. Distributor name, end-mine identity and commercial pricing are withheld under customer confidentiality.<\/div>\n<h2 id=\"decoding-8kv-shd-gc-construction\">How is SHD-GC 8 kV 3\u00d74\/0+2\u00d71+1\u00d78 AWG constructed, and why choose Class 6 copper?<\/h2>\n<p class=\"tbf-answer\">SHD-GC 8 kV 3\u00d74\/0+2\u00d71+1\u00d78 AWG pairs three individually shielded 150 mil EPR power phases with two interstitial 1 AWG grounding conductors and one yellow 8 AWG ground-check pilot. Upgrading conductor stranding to IEC 60228 Class 6 reduces bending stiffness on a ~70 mm trailing cable during pit handling and coupler make-up.<\/p>\n<p>Whereas our earlier <a href=\"https:\/\/tebaoflex-cable.com\/cases\/shd-gc-2kv-3x6-awg-mining-cable-peru\/\">Peru 2 kV SHD-GC 3\u00d76 AWG project<\/a> supplied compact 32.8 mm orange TPU trailing cable for lighter mobile machinery, stepping up to 8 kV primary pit distribution at <code>3\u00d74\/0 AWG<\/code> more than doubles cable outside diameter to ~70 mm. During technical clarification, the Peruvian distributor specifically asked whether TEBAOFLEX builds this cross-section with Class 5 or Class 6 stranding (<a href=\"https:\/\/webstore.iec.ch\/en\/publication\/71891\" rel=\"nofollow noopener\" target=\"_blank\">IEC 60228<\/a> \/ <a href=\"https:\/\/tebaoflex-cable.com\/conductor-stranding-classes\/\">conductor stranding classes<\/a>).<\/p>\n<figure class=\"tbf-diag\"><svg class=\"tbf-sys\" viewBox=\"0 0 680 330\" role=\"img\" aria-labelledby=\"tbf-c22-title\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><title id=\"tbf-c22-title\">Schematic cross-section of SHD-GC 8 kV 3\u00d74\/0 AWG + 2\u00d71 AWG + 1\u00d78 AWG medium-voltage mining trailing cable<\/title><circle cx=\"228\" cy=\"165\" r=\"134\" fill=\"#1c2126\" stroke=\"#0d1115\" stroke-width=\"2\"\/><circle cx=\"228\" cy=\"165\" r=\"115\" fill=\"none\" stroke=\"#d8b24c\" stroke-width=\"2.2\" stroke-dasharray=\"6,4\"\/><circle cx=\"228\" cy=\"165\" r=\"109\" fill=\"#2c333b\" stroke=\"#161b20\" stroke-width=\"1.1\"\/><circle cx=\"228\" cy=\"109\" r=\"45\" fill=\"#c78a4e\" stroke=\"#5c3a1b\" stroke-width=\"1.2\" stroke-dasharray=\"4,2\"\/><circle cx=\"228\" cy=\"109\" r=\"41\" fill=\"#15181c\"\/><circle cx=\"228\" cy=\"109\" r=\"37\" fill=\"#d95b38\" stroke=\"#7d2b15\" stroke-width=\"1\"\/><circle cx=\"228\" cy=\"109\" r=\"25\" fill=\"#15181c\"\/><circle cx=\"228\" cy=\"109\" r=\"21\" fill=\"#cfd5dc\" stroke=\"#68717a\" stroke-width=\"1\"\/><circle cx=\"179\" cy=\"194\" r=\"45\" fill=\"#c78a4e\" stroke=\"#5c3a1b\" stroke-width=\"1.2\" stroke-dasharray=\"4,2\"\/><circle cx=\"179\" cy=\"194\" r=\"41\" fill=\"#15181c\"\/><circle cx=\"179\" cy=\"194\" r=\"37\" fill=\"#d95b38\" stroke=\"#7d2b15\" stroke-width=\"1\"\/><circle cx=\"179\" cy=\"194\" r=\"25\" fill=\"#15181c\"\/><circle cx=\"179\" cy=\"194\" r=\"21\" fill=\"#cfd5dc\" stroke=\"#68717a\" stroke-width=\"1\"\/><circle cx=\"277\" cy=\"194\" r=\"45\" fill=\"#c78a4e\" stroke=\"#5c3a1b\" stroke-width=\"1.2\" stroke-dasharray=\"4,2\"\/><circle cx=\"277\" cy=\"194\" r=\"41\" fill=\"#15181c\"\/><circle cx=\"277\" cy=\"194\" r=\"37\" fill=\"#d95b38\" stroke=\"#7d2b15\" stroke-width=\"1\"\/><circle cx=\"277\" cy=\"194\" r=\"25\" fill=\"#15181c\"\/><circle cx=\"277\" cy=\"194\" r=\"21\" fill=\"#cfd5dc\" stroke=\"#68717a\" stroke-width=\"1\"\/><circle cx=\"163\" cy=\"128\" r=\"16\" fill=\"#cfd5dc\" stroke=\"#525a63\" stroke-width=\"1.3\"\/><circle cx=\"293\" cy=\"128\" r=\"16\" fill=\"#cfd5dc\" stroke=\"#525a63\" stroke-width=\"1.3\"\/><circle cx=\"228\" cy=\"239\" r=\"15\" fill=\"#f2cf1d\" stroke=\"#6e5c06\" stroke-width=\"1.2\"\/><circle cx=\"228\" cy=\"239\" r=\"8.5\" fill=\"#cfd5dc\" stroke=\"#525a63\" stroke-width=\"1\"\/><line x1=\"236\" y1=\"109\" x2=\"470\" y2=\"38\" stroke=\"#16202b\" stroke-width=\"1.3\"\/><circle cx=\"236\" cy=\"109\" r=\"3\" fill=\"#16202b\"\/><circle cx=\"470\" cy=\"38\" r=\"14\" fill=\"#ffffff\" stroke=\"#16202b\" stroke-width=\"1.5\"\/><text x=\"470\" y=\"43\" text-anchor=\"middle\" font-size=\"13\" font-weight=\"700\" fill=\"#16202b\">1<\/text><line x1=\"251\" y1=\"109\" x2=\"502\" y2=\"84\" stroke=\"#16202b\" stroke-width=\"1.3\"\/><circle cx=\"251\" cy=\"109\" r=\"3\" fill=\"#16202b\"\/><circle cx=\"502\" cy=\"84\" r=\"14\" fill=\"#ffffff\" stroke=\"#16202b\" stroke-width=\"1.5\"\/><text x=\"502\" y=\"89\" text-anchor=\"middle\" font-size=\"13\" font-weight=\"700\" fill=\"#16202b\">2<\/text><line x1=\"260\" y1=\"115\" x2=\"518\" y2=\"130\" stroke=\"#16202b\" stroke-width=\"1.3\"\/><circle cx=\"260\" cy=\"115\" r=\"3\" fill=\"#16202b\"\/><circle cx=\"518\" cy=\"130\" r=\"14\" fill=\"#ffffff\" stroke=\"#16202b\" stroke-width=\"1.5\"\/><text x=\"518\" y=\"135\" text-anchor=\"middle\" font-size=\"13\" font-weight=\"700\" fill=\"#16202b\">3<\/text><line x1=\"272\" y1=\"121\" x2=\"518\" y2=\"176\" stroke=\"#16202b\" stroke-width=\"1.3\"\/><circle cx=\"272\" cy=\"121\" r=\"3\" fill=\"#16202b\"\/><circle cx=\"518\" cy=\"176\" r=\"14\" fill=\"#ffffff\" stroke=\"#16202b\" stroke-width=\"1.5\"\/><text x=\"518\" y=\"181\" text-anchor=\"middle\" font-size=\"13\" font-weight=\"700\" fill=\"#16202b\">4<\/text><line x1=\"293\" y1=\"128\" x2=\"508\" y2=\"222\" stroke=\"#16202b\" stroke-width=\"1.3\"\/><circle cx=\"293\" cy=\"128\" r=\"3\" fill=\"#16202b\"\/><circle cx=\"508\" cy=\"222\" r=\"14\" fill=\"#ffffff\" stroke=\"#16202b\" stroke-width=\"1.5\"\/><text x=\"508\" y=\"227\" text-anchor=\"middle\" font-size=\"13\" font-weight=\"700\" fill=\"#16202b\">5<\/text><line x1=\"240\" y1=\"239\" x2=\"492\" y2=\"266\" stroke=\"#16202b\" stroke-width=\"1.3\"\/><circle cx=\"240\" cy=\"239\" r=\"3\" fill=\"#16202b\"\/><circle cx=\"492\" cy=\"266\" r=\"14\" fill=\"#ffffff\" stroke=\"#16202b\" stroke-width=\"1.5\"\/><text x=\"492\" y=\"271\" text-anchor=\"middle\" font-size=\"13\" font-weight=\"700\" fill=\"#16202b\">6<\/text><line x1=\"326\" y1=\"255\" x2=\"460\" y2=\"306\" stroke=\"#16202b\" stroke-width=\"1.3\"\/><circle cx=\"326\" cy=\"255\" r=\"3\" fill=\"#16202b\"\/><circle cx=\"460\" cy=\"306\" r=\"14\" fill=\"#ffffff\" stroke=\"#16202b\" stroke-width=\"1.5\"\/><text x=\"460\" y=\"311\" text-anchor=\"middle\" font-size=\"13\" font-weight=\"700\" fill=\"#16202b\">7<\/text><\/svg><figcaption>Cross-sectional geometry of the SHD-GC 8 kV 3\u00d74\/0 AWG + 2\u00d71 AWG + 1\u00d78 AWG trailing cable (numbered layers listed below).<\/figcaption><ol class=\"tbf-list\"><li>3 \u00d7 4\/0 AWG Class 6 extra-flexible tinned copper phase conductors (QJ36B-2 bridge verified at 173.60 m\u03a9\/km = 0.17360 \u03a9\/km at 20 \u00b0C)<\/li><li>Semiconductive conductor stress-control shield over each stranded phase bundle<\/li><li>150 mil (3.8 mm) nominal 90 \u00b0C EPR medium-voltage dielectric tinted high-visibility orange-red per buyer specification<\/li><li>Semiconductive insulation shield plus composite tinned-copper\/polyamide metallic shield over each phase<\/li><li>2 \u00d7 1 AWG flexible tinned-copper equipment grounding conductors positioned symmetrically in two outer interstices<\/li><li>1 \u00d7 8 AWG yellow-insulated flexible tinned-copper ground-check (pilot) conductor in the third interstice (verified at 2.1539 \u03a9\/km at 20 \u00b0C)<\/li><li>250 mil (6.4 mm) nominal extra-heavy-duty black CPE outer jacket printed TEBAOFLEX TRIPOLAR SHD-GC 8kV<\/li><\/ol><\/figure>\n<p>Every element in the <code>3\u00d74\/0 + 2\u00d71 + 1\u00d78 AWG<\/code> construction serves a specific electrical or mechanical duty under <a href=\"https:\/\/www.nema.org\/standards\/view\/portable-and-power-feeder-cables-for-use-in-mines-and-similar-applications\" rel=\"nofollow noopener\" target=\"_blank\">ANSI\/ICEA S-75-381<\/a>:<\/p><ul class=\"tbf-list\"><li><strong>Class 6 extra-flexible tinned copper:<\/strong> Finer individual tinned wires lower elastic springback when mine electricians dress the three 4\/0 AWG phases inside <a href=\"https:\/\/tebaoflex-cable.com\/solutions\/mv-mining-trailing-cable-couplers\/\">medium-voltage mining trailing cable couplers<\/a> and reduce flex fatigue over cable-boat guide horns.<\/li><li><strong>150 mil (3.8 mm) orange-red EPR + dual semiconductive stress control:<\/strong> At 8 kV, inner and outer semiconductive layers smooth radial electric stress across the 150 mil EPR dielectric while the composite tinned-copper\/polyamide shield provides continuous fault-current containment. Tinting the EPR orange-red gives unmistakable visual contrast against the black semiconductive screen during field stripback.<\/li><li><strong>Symmetrical 2 \u00d7 1 AWG grounds + 1 \u00d7 8 AWG yellow ground-check:<\/strong> Two bare\/tinned 1 AWG ground conductors occupy two outer valleys, while the yellow-insulated 8 AWG pilot core completes the fail-safe continuity loop detailed in our <a href=\"https:\/\/tebaoflex-cable.com\/mining-trailing-cable-ground-check-trip-troubleshooting\/\">mining cable ground-check trip troubleshooting guide<\/a>.<\/li><\/ul>\n<div class=\"tbf-shots\">\n<figure><img loading=\"lazy\" src=\"https:\/\/tebaoflex-cable.com\/wp-content\/uploads\/2026\/11\/shd-gc-8kv-3x4-0-class6-orange-red-epr-cross-section.webp\" alt=\"Axial cross-section of SHD-GC 8 kV 3\u00d74\/0 + 2\u00d71 + 1\u00d78 AWG resolving Class 6 tinned copper rope-lay bundles, semiconductive conductor and insulation shields, 3.8 mm orange-red EPR walls, interstitial ground conductors and yellow ground-check core\" width=\"1200\" height=\"900\" loading=\"lazy\" decoding=\"async\"><figcaption>Saw-cut cross-section of the Peru 8 kV 3\u00d74\/0 AWG cable showing the three orange-red 150 mil EPR phases, black semiconductive rings, copper braid shields, two 1 AWG ground bundles and yellow 8 AWG pilot.<\/figcaption><\/figure>\n<figure><img loading=\"lazy\" src=\"https:\/\/tebaoflex-cable.com\/wp-content\/uploads\/2026\/11\/shd-gc-8kv-3x4-0-150mil-epr-250mil-jacket-dissected.webp\" alt=\"Dissected wall rings from the Peru SHD-GC 8 kV 3\u00d74\/0 AWG production run showing the 250 mil (6.4 mm) heavy-duty black jacket, 150 mil (3.8 mm) orange-red EPR phase ring with semiconductive screen and yellow 8 AWG ground-check core\" width=\"1200\" height=\"900\" loading=\"lazy\" decoding=\"async\"><figcaption>Dissected sample rings verifying wall build: 250 mil (6.4 mm) black extra-heavy-duty CPE outer jacket, 150 mil (3.8 mm) orange-red EPR phase ring and yellow ground-check insulation.<\/figcaption><\/figure>\n<\/div>\n<h2 id=\"ampacity-and-icea-table-verification\">Why 8 kV 3\u00d74\/0 AWG is rated 321 A (not 211 A): verifying ICEA S-75-381 dimensions<\/h2>\n<p class=\"tbf-answer\">Under the ICEA S-75-381 \/ TEBAOFLEX 8 kV SHD-GC schedule at 90 \u00b0C conductor temperature and 40 \u00b0C ambient air, 3\u00d74\/0 AWG carries 321 A in free air with 150 mil insulation, 250 mil jacket and 2.75 in (69.9 mm) nominal OD. The 211 A figure sometimes copied in draft paperwork belongs to 8 kV 3\u00d71\/0 AWG.<\/p>\n<p>One of the most common documentation mistakes in medium-voltage mining tenders is copying an ampacity value from an adjacent gauge row on a multi-page datasheet. Cross-checking against our published <a href=\"https:\/\/tebaoflex-cable.com\/product\/shd-gc-cable-mining-power-cable\/\">SHD-GC 2 kV\u201325 kV mining power cable specification table<\/a> and <a href=\"https:\/\/tebaoflex-cable.com\/medium-voltage-mining-cable-selection-guide\/\">medium-voltage mining cable selection guide<\/a> confirms the exact progression across 8 kV gauges (and note that reeling on multi-layer drums requires additional layer derating):<\/p>\n<div class=\"tbf-tw\"><table class=\"tbf-wide\"><caption>Comparison of 8 kV SHD-GC sizes (90 \u00b0C conductor, 40 \u00b0C ambient air per published TEBAOFLEX \/ ICEA S-75-381 schedule)<\/caption><thead><tr><th scope=\"col\">8 kV SHD-GC size identifier<\/th><th scope=\"col\">EPR wall<\/th><th scope=\"col\">Jacket wall<\/th><th scope=\"col\">Nominal OD (in \/ mm)<\/th><th scope=\"col\">40 \u00b0C free-air ampacity<\/th><th scope=\"col\">Application note<\/th><\/tr><\/thead><tbody>\n<tr><th scope=\"row\">SHD-GC 3\u00d71\/0 + 2\u00d74 + 1\u00d78 AWG \u00b7 8 kV<\/th><td>150 mil \/ 3.8 mm<\/td><td>220 mil \/ 5.6 mm<\/td><td>2.32 in \/ 58.9 mm<\/td><td>211 A<\/td><td>Reference row often confused in drafts<\/td><\/tr>\n<tr><th scope=\"row\">SHD-GC 3\u00d72\/0 + 2\u00d73 + 1\u00d78 AWG \u00b7 8 kV<\/th><td>150 mil \/ 3.8 mm<\/td><td>235 mil \/ 6.0 mm<\/td><td>2.46 in \/ 62.5 mm<\/td><td>243 A<\/td><td>Intermediate shovel \/ drill feeder<\/td><\/tr>\n<tr><th scope=\"row\">SHD-GC 3\u00d73\/0 + 2\u00d72 + 1\u00d78 AWG \u00b7 8 kV<\/th><td>150 mil \/ 3.8 mm<\/td><td>250 mil \/ 6.4 mm<\/td><td>2.62 in \/ 66.5 mm<\/td><td>279 A<\/td><td>Heavy skid \/ substation feeder<\/td><\/tr>\n<tr><th scope=\"row\">SHD-GC 3\u00d74\/0 + 2\u00d71 + 1\u00d78 AWG \u00b7 8 kV (This order)<\/th><td>150 mil \/ 3.8 mm<\/td><td>250 mil \/ 6.4 mm<\/td><td>2.75 in \/ 69.9 mm (70.94 mm measured)<\/td><td>321 A<\/td><td>Peru 200 m Class 6 production build<\/td><\/tr>\n<tr><th scope=\"row\">SHD-GC 3\u00d7250 kcmil + 2\u00d71\/0 + 1\u00d76 AWG \u00b7 8 kV<\/th><td>150 mil \/ 3.8 mm<\/td><td>250 mil \/ 6.4 mm<\/td><td>2.89 in \/ 73.4 mm<\/td><td>355 A<\/td><td>Steps ground-check up to 1\u00d76 AWG<\/td><\/tr>\n<\/tbody><\/table><\/div>\n<h2 id=\"factory-testing-and-fob-dispatch\">Factory Kelvin bridge resistance, 70.94 mm caliper check and 200 m export drum preparation<\/h2>\n<p class=\"tbf-answer\">Prior to winding the continuous 200 m export reel, factory inspection recorded 173.60 m\u03a9\/km (0.17360 \u03a9\/km) 20 \u00b0C DC resistance on the 4\/0 AWG Class 6 phase conductor, 2,153.9 m\u03a9\/km on the 8 AWG ground-check core and 70.94 mm finished outside diameter beside the Spanish TRIPOLAR print line.<\/p>\n<p>Before the order entered final extrusion, the Peruvian buyer&#8217;s China-based representative visited our Taicang workshop to verify stranding and compounding controls. Upon completion of the 20-day manufacturing cycle, routine inspection documented the finished 200 m length in accordance with our <a href=\"https:\/\/tebaoflex-cable.com\/cable-factory-acceptance-test\/\">cable factory acceptance test<\/a> procedures:<\/p><ul class=\"tbf-list\"><li><strong>Precision Kelvin bridge DC resistance (<code>QJ36B-2<\/code>):<\/strong> Measured on a 1 m specimen at 20.6 \u00b0C ambient, temperature-corrected 20 \u00b0C DC resistance on the 4\/0 AWG Class 6 tinned-copper phase conductor read <strong>173.60 m\u03a9\/km (0.17360 \u03a9\/km)<\/strong>, and the 8 AWG yellow ground-check conductor read <strong>2,153.9 m\u03a9\/km (2.1539 \u03a9\/km)<\/strong> at 20 \u00b0C (measured at 17.2 \u00b0C)\u2014confirming full copper cross-section and clean tinning.<\/li><li><strong>Finished diameter &amp; Spanish TRIPOLAR marking:<\/strong> Digital caliper checks directly over the <code>TEBAOFLEX TRIPOLAR SHD-GC 8kV 3x4\/0AWG+2x1AWG+1x8AWG ICEA S-75-381 Standard 2026<\/code> metre-marked black jacket recorded <strong>70.94 mm<\/strong> (within +1.5 % of the 69.9 mm \/ 2.75 in catalogue nominal, matching 8 kV coupler gland entry boots).<\/li><li><strong>Export reel &amp; COQ documentation:<\/strong> The uncut 200 m cable was end-sealed and wound onto a lagged wooden export drum for FOB Shanghai dispatch via the buyer&#8217;s nominated freight forwarder, accompanied by the Certificate of Quality (COQ). For mines operating DIN VDE equipment alongside North American shovels, compare our <a href=\"https:\/\/tebaoflex-cable.com\/product\/ntmcetmpu-cable\/\">(N)TMCETMPU 6\/10 kV to 14\/25 kV mining trailing cable<\/a>.<\/li><\/ul>\n<div class=\"tbf-shots\">\n<figure><img loading=\"lazy\" src=\"https:\/\/tebaoflex-cable.com\/wp-content\/uploads\/2026\/11\/shd-gc-8kv-3x4-0-qj36b-2-dc-bridge-173-60-mohm-km.webp\" alt=\"QJ36B-2 precision digital Kelvin bridge display recording 20 \u00b0C temperature-corrected DC conductor resistance R20 = 173.60 m\u03a9\/km (0.17360 \u03a9\/km) on the 4\/0 AWG Class 6 tinned-copper phase conductor\" width=\"1200\" height=\"900\" loading=\"lazy\" decoding=\"async\"><figcaption>QJ36B-2 digital Kelvin bridge recording Rt = 174.01 \u00b5\u03a9 at 20.6 \u00b0C and temperature-corrected R20 = 173.60 m\u03a9\/km (0.17360 \u03a9\/km) on the 4\/0 AWG Class 6 phase conductor.<\/figcaption><\/figure>\n<figure><img loading=\"lazy\" src=\"https:\/\/tebaoflex-cable.com\/wp-content\/uploads\/2026\/11\/shd-gc-8kv-3x4-0-caliper-70-94mm-outer-diameter.webp\" alt=\"Digital caliper measuring 70.94 mm finished outside diameter right beside the 3x4\/0AWG+2x1AWG+1x8AWG ICEA S-75-381 print line (nominal catalogue OD 69.9 mm \/ 2.75 in)\" width=\"1200\" height=\"754\" loading=\"lazy\" decoding=\"async\"><figcaption>Sanliang digital caliper verifying 70.94 mm finished outside diameter adjacent to the 3&#215;4\/0AWG+2x1AWG+1x8AWG ICEA S-75-381 jacket legend.<\/figcaption><\/figure>\n<\/div>\n<div class=\"tbf-shots\">\n<figure><img loading=\"lazy\" src=\"https:\/\/tebaoflex-cable.com\/wp-content\/uploads\/2026\/11\/shd-gc-8kv-3x4-0-2x1-1x8-icea-s-75-381-sheath-marking.webp\" alt=\"Sheath marking on the black 250 mil outer jacket reading SHD-GC 8kV 3x4\/0AWG+2x1AWG+1x8AWG ICEA S-75-381\" width=\"1200\" height=\"900\" loading=\"lazy\" decoding=\"async\"><figcaption>Crisp metre-spaced jacket marking identifying SHD-GC 8kV 3&#215;4\/0AWG+2x1AWG+1x8AWG ICEA S-75-381 along the 250 mil black CPE sheath.<\/figcaption><\/figure>\n<figure><img loading=\"lazy\" src=\"https:\/\/tebaoflex-cable.com\/wp-content\/uploads\/2026\/11\/shd-gc-8kv-3x4-0-200m-continuous-wooden-export-drum.webp\" alt=\"Finished 200 m continuous length of TEBAOFLEX SHD-GC 8 kV 3\u00d74\/0 + 2\u00d71 + 1\u00d78 AWG mining power cable wound onto a wooden export reel with sealed end cap for FOB Shanghai dispatch\" width=\"1200\" height=\"900\" loading=\"lazy\" decoding=\"async\"><figcaption>Completed 200 m continuous length wound onto a wooden export drum with heat-shrink moisture-sealed end cap awaiting FOB Shanghai container dispatch.<\/figcaption><\/figure>\n<\/div>\n<h2 id=\"rfq-checklist\">What to specify when ordering 5 kV, 8 kV, 15 kV or 25 kV SHD-GC for Latin American mines<\/h2>\n<p class=\"tbf-answer\">To quote medium-voltage Type SHD-GC trailing cable without coupler or relay mismatches, confirm the voltage class (2 kV to 25 kV), phase\/ground\/pilot AWG sizes, Class 5 vs Class 6 stranding, EPR phase colour preference, jacket material\/colour and exact metric or foot reel lengths.<\/p>\n<div class=\"tbf-need\"><strong>Send these details for an engineering cross-check before quotation:<\/strong>\n<ul>\n<li>Rated voltage class (2 kV, 5 kV, 8 kV, 15 kV or 25 kV) and mine network phase-to-phase voltage (such as 4.16 kV, 6.9 kV, 7.2 kV or 13.8 kV)<\/li>\n<li>Exact conductor layout (for example 3\u00d74\/0 + 2\u00d71 + 1\u00d78 AWG) and whether Class 6 extra-flexible tinned stranding is required<\/li>\n<li>EPR phase insulation colour (orange-red vs. natural\/coloured phases), outer jacket material\/colour (black, yellow or orange CPE\/TPU) and Spanish\/English print legend<\/li>\n<li>Continuous drum lengths (200 m, 500 m or 1,000 ft), coupler gland entry ID range and FOB\/CIF port documentation requirements<\/li>\n<\/ul>\n<p>TEBAOFLEX manufactures custom Type SHD-GC cables from 2 kV through 25 kV from a 50 m minimum order quantity, with a standard manufacturing lead time of 7 to 45 working days as of November 2026 depending on voltage tier and order schedule. See mine-wide power architectures on our <a href=\"https:\/\/tebaoflex-cable.com\/solutions\/mining-tunneling\/\">mining and tunneling cable solutions<\/a> hub and full model listings under <a href=\"https:\/\/tebaoflex-cable.com\/products\/mining-tunneling-cables\/\">mining and tunneling cables<\/a>.<\/p><\/div>\n<p><a class=\"tbf-cta\" href=\"https:\/\/tebaoflex-cable.com\/contact-us\/#request-quote\">Send your SHD-GC 8 kV\u201325 kV specification for a factory quote &rarr;<\/a><\/p>\n<h2 id=\"faq\">Frequently asked questions on SHD-GC 8 kV 3\u00d74\/0 AWG mining cables<\/h2>\n<div class=\"tbf-faq\">\n<details><summary>What does 3\u00d74\/0 + 2\u00d71 + 1\u00d78 AWG mean on an 8 kV SHD-GC mining cable?<\/summary><p>Under ANSI\/ICEA S-75-381 (formerly NEMA WC 58), 3\u00d74\/0 AWG are the three individually shielded 8 kV power conductors, 2\u00d71 AWG are two uninsulated flexible tinned-copper grounding conductors placed in two outer valleys to split fault return current symmetrically, and 1\u00d78 AWG is the yellow-insulated ground-check pilot conductor occupying the third valley for continuous ground-loop monitoring.<\/p><\/details>\n<details><summary>What is the correct 40 \u00b0C ampacity of SHD-GC 8 kV 3\u00d74\/0 AWG\u2014321 A or 211 A?<\/summary><p>In the ICEA S-75-381 \/ TEBAOFLEX 8 kV SHD-GC specification table at 90 \u00b0C conductor temperature and 40 \u00b0C ambient air, 3\u00d74\/0 AWG is rated 321 A (single cable in free air), whereas 211 A belongs to the smaller 8 kV 3\u00d71\/0 AWG size. Cross-check conductor gauge before transcribing ampacity onto mine relay settings or shipping certificates.<\/p><\/details>\n<details><summary>Why did the Peruvian mining buyer request Class 6 tinned copper stranding instead of Class 5?<\/summary><p>Class 6 stranding uses finer individual tinned copper wires than Class 5 at the same cross-section, lowering bending stiffness when a large 70 mm diameter 8 kV trailing cable is dragged across mine benches, looped into shovel cable boats or terminated inside compact 8 kV mining couplers.<\/p><\/details>\n<details><summary>Why is 8 kV SHD-GC built with 150 mil EPR insulation and metallic phase shields?<\/summary><p>Above 2 kV, electric-field gradients across core air gaps would ionize air and erode unshielded rubber. ANSI\/ICEA S-75-381 steps nominal EPR insulation thickness to 150 mil (3.8 mm) for 8 kV service and surrounds each core with inner\/outer semiconductive shields plus a tinned-copper composite braid to confine radial dielectric stress and trip ground-fault protection immediately upon rock impact.<\/p><\/details>\n<details><summary>Can TEBAOFLEX manufacture 8 kV SHD-GC in custom metric drum lengths like 200 m and 500 m?<\/summary><p>Yes. Alongside standard 1,000 ft reels, TEBAOFLEX produces custom continuous metric lengths such as 200 m and 500 m from a 50 m minimum order quantity, with a standard manufacturing lead time of 7 to 45 working days depending on voltage tier and factory schedule.<\/p><\/details>\n<\/div>\n<div class=\"tbf-byline\">Project record prepared by <a href=\"https:\/\/tebaoflex-cable.com\/author\/zheng-lipeng\/\">Zheng LiPeng<\/a>, Manager, with the TEBAOFLEX cable engineering team in Taicang, Jiangsu \u00b7 Published <time datetime=\"2026-11-18\">18 November 2026<\/time>. More about our manufacturing and testing facilities on our <a href=\"https:\/\/tebaoflex-cable.com\/about-us\/\">about us page<\/a>.<\/div>\n<div class=\"tbf-back\"><a href=\"https:\/\/tebaoflex-cable.com\/cases\/\">&larr; Back to all industrial cable application cases<\/a><\/div>\n<\/div>\n\n<script type=\"application\/ld+json\">{\"@context\": \"https:\/\/schema.org\", \"@type\": \"Article\", \"headline\": \"SHD-GC 8 kV 3\u00d74\/0+2\u00d71+1\u00d78 AWG Class 6 Mining Power Cable (200 m) for Peru\", \"description\": \"Case: 200 m SHD-GC 8 kV 3\u00d74\/0+2\u00d71+1\u00d78 AWG Class 6 mining cable built for Peru \u2014 150 mil orange-red EPR, 70.94 mm OD, 0.1736 \u03a9\/km bridge and 321 A.\", \"mainEntityOfPage\": {\"@type\": \"WebPage\", \"@id\": \"https:\/\/tebaoflex-cable.com\/cases\/shd-gc-8kv-3x4-0-awg-mining-cable-peru\/\"}, \"url\": \"https:\/\/tebaoflex-cable.com\/cases\/shd-gc-8kv-3x4-0-awg-mining-cable-peru\/\", \"inLanguage\": \"en\", \"image\": [{\"@type\": \"ImageObject\", \"url\": \"https:\/\/tebaoflex-cable.com\/wp-content\/uploads\/2026\/11\/shd-gc-8kv-3x4-0-awg-2x1-1x8-mining-cable-peru-hero.webp\", \"width\": 1200, \"height\": 900}, {\"@type\": \"ImageObject\", \"url\": \"https:\/\/tebaoflex-cable.com\/wp-content\/uploads\/2026\/11\/shd-gc-8kv-3x4-0-class6-orange-red-epr-cross-section.webp\", \"width\": 1200, \"height\": 900}, {\"@type\": \"ImageObject\", \"url\": \"https:\/\/tebaoflex-cable.com\/wp-content\/uploads\/2026\/11\/shd-gc-8kv-3x4-0-caliper-70-94mm-outer-diameter.webp\", \"width\": 1200, \"height\": 754}], \"author\": {\"@type\": \"Person\", \"@id\": \"https:\/\/tebaoflex-cable.com\/author\/zheng-lipeng\/\", \"name\": \"Zheng LiPeng\", \"url\": \"https:\/\/tebaoflex-cable.com\/author\/zheng-lipeng\/\", \"jobTitle\": \"Manager\", \"image\": \"https:\/\/tebaoflex-cable.com\/wp-content\/uploads\/2026\/09\/tebaoflex-author-headshot-100x100.jpg\", \"sameAs\": [\"https:\/\/www.linkedin.com\/in\/tebaoflexcable\/\"], \"worksFor\": {\"@id\": \"https:\/\/tebaoflex-cable.com\/#organization\"}}, \"publisher\": {\"@type\": \"Organization\", \"@id\": \"https:\/\/tebaoflex-cable.com\/#organization\", \"name\": \"TEBAOFLEX\", \"url\": \"https:\/\/tebaoflex-cable.com\/\"}, \"about\": [\"SHD-GC 8 kV 3\u00d74\/0 AWG mining cable\", \"ANSI\/ICEA S-75-381 medium-voltage trailing cable\", \"Class 6 tinned copper mining power cable\"], \"datePublished\": \"2026-11-18\", \"dateModified\": \"2026-11-18\"}<\/script>\n<script type=\"application\/ld+json\">{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What does 3\u00d74\/0 + 2\u00d71 + 1\u00d78 AWG mean on an 8 kV SHD-GC mining cable?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Under ANSI\/ICEA S-75-381 (formerly NEMA WC 58), 3\u00d74\/0 AWG are the three individually shielded 8 kV power conductors, 2\u00d71 AWG are two uninsulated flexible tinned-copper grounding conductors placed in two outer valleys to split fault return current symmetrically, and 1\u00d78 AWG is the yellow-insulated ground-check pilot conductor occupying the third valley for continuous ground-loop monitoring.\"}}, {\"@type\": \"Question\", \"name\": \"What is the correct 40 \u00b0C ampacity of SHD-GC 8 kV 3\u00d74\/0 AWG\u2014321 A or 211 A?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"In the ICEA S-75-381 \/ TEBAOFLEX 8 kV SHD-GC specification table at 90 \u00b0C conductor temperature and 40 \u00b0C ambient air, 3\u00d74\/0 AWG is rated 321 A (single cable in free air), whereas 211 A belongs to the smaller 8 kV 3\u00d71\/0 AWG size. Cross-check conductor gauge before transcribing ampacity onto mine relay settings or shipping certificates.\"}}, {\"@type\": \"Question\", \"name\": \"Why did the Peruvian mining buyer request Class 6 tinned copper stranding instead of Class 5?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Class 6 stranding uses finer individual tinned copper wires than Class 5 at the same cross-section, lowering bending stiffness when a large 70 mm diameter 8 kV trailing cable is dragged across mine benches, looped into shovel cable boats or terminated inside compact 8 kV mining couplers.\"}}, {\"@type\": \"Question\", \"name\": \"Why is 8 kV SHD-GC built with 150 mil EPR insulation and metallic phase shields?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Above 2 kV, electric-field gradients across core air gaps would ionize air and erode unshielded rubber. ANSI\/ICEA S-75-381 steps nominal EPR insulation thickness to 150 mil (3.8 mm) for 8 kV service and surrounds each core with inner\/outer semiconductive shields plus a tinned-copper composite braid to confine radial dielectric stress and trip ground-fault protection immediately upon rock impact.\"}}, {\"@type\": \"Question\", \"name\": \"Can TEBAOFLEX manufacture 8 kV SHD-GC in custom metric drum lengths like 200 m and 500 m?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes. Alongside standard 1,000 ft reels, TEBAOFLEX produces custom continuous metric lengths such as 200 m and 500 m from a 50 m minimum order quantity, with a standard manufacturing lead time of 7 to 45 working days depending on voltage tier and factory schedule.\"}}]}<\/script>\n","protected":false},"excerpt":{"rendered":"<p>Projektbericht: 200 m Bergbauleitung SHD-GC 8 kV 3\u00d74\/0+2\u00d71+1\u00d78 AWG Klasse 6 gefertigt f\u00fcr Peru \u2014 150 mil orangerote EPR-Aderisolation, 70.94 mm Au\u00dfendurchmesser, 0.1736 \u03a9\/km Br\u00fcckenwiderstand und 321 A.<\/p>","protected":false},"author":1,"featured_media":8517,"parent":3117,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-8528","page","type-page","status-publish","has-post-thumbnail","hentry"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/tebaoflex-cable.com\/de\/wp-json\/wp\/v2\/pages\/8528","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/tebaoflex-cable.com\/de\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/tebaoflex-cable.com\/de\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/tebaoflex-cable.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/tebaoflex-cable.com\/de\/wp-json\/wp\/v2\/comments?post=8528"}],"version-history":[{"count":0,"href":"https:\/\/tebaoflex-cable.com\/de\/wp-json\/wp\/v2\/pages\/8528\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/tebaoflex-cable.com\/de\/wp-json\/wp\/v2\/pages\/3117"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/tebaoflex-cable.com\/de\/wp-json\/wp\/v2\/media\/8517"}],"wp:attachment":[{"href":"https:\/\/tebaoflex-cable.com\/de\/wp-json\/wp\/v2\/media?parent=8528"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}