{"id":5686,"date":"2026-10-21T09:35:14","date_gmt":"2026-10-21T01:35:14","guid":{"rendered":"https:\/\/tebaoflex-cable.com\/rubber-cable-vs-pvc-cable\/"},"modified":"2026-10-22T10:25:26","modified_gmt":"2026-10-22T02:25:26","slug":"rubber-cable-vs-pvc-cable","status":"publish","type":"post","link":"https:\/\/tebaoflex-cable.com\/fr\/rubber-cable-vs-pvc-cable\/","title":{"rendered":"C\u00e2ble caoutchouc ou c\u00e2ble PVC : temp\u00e9rature, flexion, huile et domaine d&#039;emploi de chacun"},"content":{"rendered":"<article class=\"tf-rvp-page\">\n<section class=\"tf-rvp-hero\" aria-label=\"Synth\u00e8se : c\u00e2ble caoutchouc ou PVC\">\n<p class=\"tf-rvp-eyebrow\">Mat\u00e9riaux des c\u00e2bles souples<\/p>\n<div class=\"tf-rvp-lede\">\n<p><strong>Le c\u00e2ble caoutchouc et le c\u00e2ble PVC diff\u00e8rent moins par leur temp\u00e9rature nominale que par ce \u00e0 quoi ils r\u00e9sistent.<\/strong> Un cordon caoutchouc comme le H07RN-F reste flexible jusqu&#039;\u00e0 environ \u221225 \u00b0C, poss\u00e8de une gaine test\u00e9e \u00e0 l&#039;huile et \u00e0 l&#039;ozone et s&#039;utilise en ext\u00e9rieur, sur les chantiers et sur les \u00e9quipements mobiles. Un cordon PVC comme le H05VV-F est plus petit, plus l\u00e9ger et moins cher, mais c&#039;est un c\u00e2ble d&#039;int\u00e9rieur pour service l\u00e9ger, que notre fiche technique ne donne en flexion que jusqu&#039;\u00e0 \u22125 \u00b0C. Contrairement \u00e0 une id\u00e9e r\u00e9pandue, le H07RN-F ordinaire est donn\u00e9 pour 60 \u00b0C \u00e0 l&#039;\u00e2me et le H05VV-F pour 70 \u00b0C (EN 50525-2-21 et EN 50525-2-11) ; le caoutchouc ne supporte une temp\u00e9rature plus \u00e9lev\u00e9e que dans ses versions EPR, EVA ou silicone.<\/p>\n<\/div>\n<div class=\"tf-rvp-facts\" aria-label=\"Faits cl\u00e9s\">\n<div class=\"tf-rvp-fact\"><span>Temp\u00e9rature du conducteur<\/span><strong>H07RN-F 60 \u00b0C \u00b7 H05VV-F 70 \u00b0C<\/strong><\/div>\n<div class=\"tf-rvp-fact\"><span>Flexion jusqu&#039;\u00e0<\/span><strong>Caoutchouc \u221225 \u00b0C \u00b7 PVC \u22125 \u00b0C<\/strong><\/div>\n<div class=\"tf-rvp-fact\"><span>Ext\u00e9rieur et chantiers<\/span><strong>H07RN-F oui \u00b7 H05VV-F non<\/strong><\/div>\n<div class=\"tf-rvp-fact\"><span>Halog\u00e8nes<\/span><strong>Les gaines PVC et CR contiennent du chlore<\/strong><\/div>\n<\/p><\/div>\n<\/section>\n<nav class=\"tf-rvp-toc\" aria-label=\"Sur cette page\">\n    <strong>Sur cette page<\/strong><\/p>\n<ol>\n<li><a href=\"#at-a-glance\">En un coup d&#039;\u0153il<\/a><\/li>\n<li><a href=\"#what-is-rubber\">Ce qu&#039;est le caoutchouc<\/a><\/li>\n<li><a href=\"#temperature\">Temp\u00e9ratures nominales<\/a><\/li>\n<li><a href=\"#cold-and-movement\">Froid et mouvement<\/a><\/li>\n<li><a href=\"#environment\">Huile, ozone et eau<\/a><\/li>\n<li><a href=\"#fire\">Feu et halog\u00e8nes<\/a><\/li>\n<li><a href=\"#size-and-cost\">Taille, poids et co\u00fbt<\/a><\/li>\n<li><a href=\"#choose\">Lequel choisir<\/a><\/li>\n<li><a href=\"#quote\">\u00c0 envoyer<\/a><\/li>\n<li><a href=\"#faq\">Questions<\/a><\/li>\n<\/ol>\n<\/nav>\n<h2 id=\"at-a-glance\">C\u00e2ble caoutchouc ou PVC en bref<\/h2>\n<p>Les deux cordons souples harmonis\u00e9s les plus souvent compar\u00e9s sont le <a href=\"https:\/\/tebaoflex-cable.com\/fr\/product\/h07rn-f-cable\/\">c\u00e2ble caoutchouc H07RN-F<\/a> et <a href=\"https:\/\/tebaoflex-cable.com\/fr\/product\/h05vv-f-300-500v-pvc-flexible-cable\/\">le c\u00e2ble souple PVC H05VV-F<\/a>. Choisissez le caoutchouc lorsque le c\u00e2ble bouge, est pos\u00e9 en ext\u00e9rieur, est expos\u00e9 \u00e0 l&#039;huile ou travaille dans le froid ; choisissez le PVC pour les raccordements l\u00e9gers, secs et int\u00e9rieurs, o\u00f9 sa taille plus r\u00e9duite et son prix plus bas sont un avantage.<\/p>\n<table>\n<caption>C\u00e2ble caoutchouc H07RN-F et c\u00e2ble PVC H05VV-F compar\u00e9s (temp\u00e9ratures, rayons de courbure et dimensions selon les fiches techniques TEBAOFLEX)<\/caption>\n<thead>\n<tr>\n<th scope=\"col\">Propri\u00e9t\u00e9<\/th>\n<th scope=\"col\">Caoutchouc : H07RN-F<\/th>\n<th scope=\"col\">PVC : H05VV-F<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Type de mat\u00e9riau<\/td>\n<td>Thermodurcissable : isolation en caoutchouc r\u00e9ticul\u00e9 (EI 4) et gaine de type polychloropr\u00e8ne (EM 2)<\/td>\n<td>Thermoplastique : isolation PVC (TI 2) et gaine PVC (TM 2)<\/td>\n<\/tr>\n<tr>\n<td>Tension assign\u00e9e<\/td>\n<td>450\/750 V<\/td>\n<td>300\/500 V<\/td>\n<\/tr>\n<tr>\n<td>Temp\u00e9rature maximale du conducteur<\/td>\n<td>60 \u00b0C<\/td>\n<td>70 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Temp\u00e9rature de flexion minimale<\/td>\n<td>\u221225 \u00b0C<\/td>\n<td>\u22125 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Rayon de courbure en mouvement<\/td>\n<td>4 \u00e0 6 \u00d7 D selon le diam\u00e8tre<\/td>\n<td>7.5 \u00d7 D<\/td>\n<\/tr>\n<tr>\n<td>Huile et ozone<\/td>\n<td>Gaine test\u00e9e pour la r\u00e9sistance \u00e0 l&#039;huile et \u00e0 l&#039;ozone<\/td>\n<td>Gaine PVC \u00e0 usage g\u00e9n\u00e9ral, sans essai \u00e0 l&#039;ozone<\/td>\n<\/tr>\n<tr>\n<td>O\u00f9 il est utilis\u00e9<\/td>\n<td>Int\u00e9rieur et ext\u00e9rieur : chantiers, ateliers, mat\u00e9riel agricole et industriel<\/td>\n<td>Int\u00e9rieur uniquement : petits appareils et raccordements l\u00e9gers et prot\u00e9g\u00e9s<\/td>\n<\/tr>\n<tr>\n<td>Eau<\/td>\n<td>Locaux mouill\u00e9s ; l&#039;immersion exige le H07RN8-F<\/td>\n<td>Locaux int\u00e9rieurs secs<\/td>\n<\/tr>\n<tr>\n<td>Feu<\/td>\n<td>Non propagateur de la flamme selon IEC 60332-1-2 ; contient du chlore<\/td>\n<td>Non propagateur de la flamme selon IEC 60332-1-2 ; contient du chlore<\/td>\n<\/tr>\n<tr>\n<td>Diam\u00e8tre ext\u00e9rieur et poids, 3G2.5 mm\u00b2<\/td>\n<td>12 mm, 230 kg\/km<\/td>\n<td>9.9 mm, environ 156 kg\/km<\/td>\n<\/tr>\n<tr>\n<td>Prix au m\u00e8tre<\/td>\n<td>Plus \u00e9lev\u00e9e<\/td>\n<td>Plus faible<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2 id=\"what-is-rubber\">Qu&#039;est-ce qu&#039;un c\u00e2ble caoutchouc ?<\/h2>\n<p>Un c\u00e2ble caoutchouc est un c\u00e2ble dont l&#039;isolation, la gaine ou les deux sont en \u00e9lastom\u00e8re r\u00e9ticul\u00e9. La r\u00e9ticulation (vulcanisation) lie les cha\u00eenes de polym\u00e8re entre elles : le mat\u00e9riau reste \u00e9lastique, ne fond pas \u00e0 la chaleur et reprend sa forme apr\u00e8s avoir \u00e9t\u00e9 pli\u00e9. Le PVC est un thermoplastique : il est souple gr\u00e2ce aux plastifiants, il se ramollit en se r\u00e9chauffant et se rigidifie en refroidissant.<\/p>\n<p>Dans les normes de c\u00e2bles, le &#8220;caoutchouc&#8221; n&#039;est pas un m\u00e9lange unique. <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/112784\" target=\"_blank\" rel=\"noopener\">IEC 60245-1<\/a> couvre les c\u00e2bles \u00e0 isolation caoutchouc jusqu&#039;\u00e0 450\/750 V et <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/71989\" target=\"_blank\" rel=\"noopener\">IEC 60227-1<\/a> couvre les c\u00e2bles \u00e0 isolation PVC, et toutes deux d\u00e9finissent les m\u00e9langes par les essais qu&#039;ils r\u00e9ussissent, et non par une recette. Les \u00e9lastom\u00e8res que vous rencontrerez dans les c\u00e2bles souples sont :<\/p>\n<ul>\n<li><strong>Caoutchouc courant (EI 4)<\/strong>, l&#039;isolation du H07RN-F, donn\u00e9e pour 60 \u00b0C.<\/li>\n<li><strong>EPR ou EPDM<\/strong>, un caoutchouc \u00e9thyl\u00e8ne-propyl\u00e8ne utilis\u00e9 comme isolation 90 \u00b0C dans les cordons de guirlande, d&#039;enroulement, de mine et nord-am\u00e9ricains ; consultez notre <a href=\"https:\/\/tebaoflex-cable.com\/fr\/epr-insulation\/\">guide de l&#039;isolation EPR<\/a>.<\/li>\n<li><strong>Polychloropr\u00e8ne (CR)<\/strong>, la gaine classique, robuste et r\u00e9sistante \u00e0 l&#039;huile, d\u00e9sign\u00e9e par N dans les d\u00e9signations harmonis\u00e9es.<\/li>\n<li><strong>Poly\u00e9thyl\u00e8ne chlor\u00e9 (CPE)<\/strong>, une gaine ext\u00e9rieure courante sur les cordons SOOW et les c\u00e2bles miniers.<\/li>\n<li><strong>Nitrile (NBR), EVA et silicone<\/strong>, pour les services avec huile, chaleur ou haute temp\u00e9rature ; l&#039;isolation silicone est donn\u00e9e pour 180 \u00b0C.<\/li>\n<\/ul>\n<p>L&#039;isolation et la gaine se choisissent s\u00e9par\u00e9ment. <a href=\"https:\/\/tebaoflex-cable.com\/fr\/product\/soow-cable-600v-epdm-cpe\/\">Le cordon SOOW<\/a> a une isolation EPDM sous une gaine ext\u00e9rieure CPE, notre <a href=\"https:\/\/tebaoflex-cable.com\/fr\/product\/ngflgoeu-flat-festoon-cable\/\">c\u00e2ble guirlande plat caoutchouc NGFLGOEU<\/a> a une isolation EPR sous une gaine en chloropr\u00e8ne, et certains types harmonis\u00e9s placent une gaine en polyur\u00e9thane sur des conducteurs isol\u00e9s en caoutchouc. Examinez donc les deux couches avant de qualifier un c\u00e2ble de &#8220;caoutchouc&#8221; ou de &#8220;PVC&#8221;.<\/p>\n<figure class=\"tebaoflex-tab-image wp-block-image size-large\">\n    <img loading=\"lazy\" src=\"https:\/\/tebaoflex-cable.com\/wp-content\/uploads\/2026\/10\/pvc-and-rubber-cable-cores-close-up.webp\" alt=\"Gros plan de deux c\u00e2bles TEBAOFLEX : conducteurs isol\u00e9s en cuivre \u00e0 brins fins, isolation PVC bleue et marron sous une tresse de cuivre et une gaine PVC noire, et extr\u00e9mit\u00e9 coup\u00e9e d&#039;un c\u00e2ble minier Type G-GC avec conducteurs isol\u00e9s EPR dans une gaine ext\u00e9rieure CPE noire\" width=\"1600\" height=\"1000\" decoding=\"async\"><figcaption>\u00c0 gauche : un c\u00e2ble blind\u00e9 300\/500 V \u00e0 isolation PVC et gaine PVC. \u00c0 droite : un c\u00e2ble minier Type G-GC 2 kV \u00e0 isolation EPR et gaine ext\u00e9rieure CPE. Les deux sont des \u00e9chantillons de production TEBAOFLEX.<\/figcaption><\/figure>\n<h3>Comment lire la d\u00e9signation<\/h3>\n<p>Les codes europ\u00e9ens harmonis\u00e9s (HD 361) d\u00e9crivent les mat\u00e9riaux en toutes lettres. Dans H07RN-F, H signifie harmonis\u00e9, 07 signifie 450\/750 V, R est l&#039;isolation caoutchouc, N une gaine en polychloropr\u00e8ne et F une \u00e2me souple \u00e0 brins fins. Dans H05VV-F, 05 signifie 300\/500 V et les deux lettres V d\u00e9signent l&#039;isolation PVC et la gaine PVC. Les noms des cordons nord-am\u00e9ricains fonctionnent diff\u00e9remment. SO, SOOW et SJOOW sont des cordons en caoutchouc thermodurcissable. Un T dans le nom, comme dans SJT ou SJTOW, indique une construction thermoplastique, et un E indique un \u00e9lastom\u00e8re thermoplastique, comme l&#039;explique notre <a href=\"https:\/\/tebaoflex-cable.com\/fr\/soow-vs-sjoow-vs-seoow\/\">guide SOOW vs SJOOW vs SEOOW<\/a>. <a href=\"https:\/\/www.osha.gov\/laws-regs\/standardinterpretations\/2004-03-29\" target=\"_blank\" rel=\"noopener\">L&#039;interpr\u00e9tation du NEC par l&#039;OSHA<\/a> classe S, ST, SO et STO parmi les cordons pour service dur et SJ, SJO, SJT et SJTO parmi les cordons pour service dur junior, quel que soit le mat\u00e9riau.<\/p>\n<h2 id=\"temperature\">Le c\u00e2ble caoutchouc est-il donn\u00e9 pour des temp\u00e9ratures plus \u00e9lev\u00e9es que le PVC ?<\/h2>\n<p>Pas en tant que cat\u00e9gorie. EN 50525-2-21 donne les c\u00e2bles souples en caoutchouc ordinaire comme le H07RN-F pour 60 \u00b0C \u00e0 l&#039;\u00e2me, tandis que EN 50525-2-11 donne le H05VV-F pour 70 \u00b0C. Le caoutchouc ne d\u00e9passe le PVC que dans ses versions r\u00e9sistantes \u00e0 la chaleur : les types \u00e0 isolation EPR sont donn\u00e9s pour 90 \u00b0C, les types EVA pour 110 \u00b0C et le silicone pour 180 \u00b0C.<\/p>\n<p>Les tableaux de m\u00e9langes disent la m\u00eame chose. <a href=\"https:\/\/knowledge.bsigroup.com\/products\/insulating-sheathing-and-covering-materials-for-low-voltage-energy-cables-cross-linked-elastomeric-insulating-compounds\" target=\"_blank\" rel=\"noopener\">EN 50363-1<\/a> classe l&#039;isolation caoutchouc EI 4 \u00e0 60 \u00b0C, l&#039;EI 7 de type EPR \u00e0 90 \u00b0C et l&#039;EI 2 silicone \u00e0 180 \u00b0C. <a href=\"https:\/\/knowledge.bsigroup.com\/products\/insulating-sheathing-and-covering-materials-for-low-voltage-energy-cables-pvc-insulating-compounds\" target=\"_blank\" rel=\"noopener\">EN 50363-3<\/a> classe l&#039;isolation PVC souple TI 2 \u00e0 70 \u00b0C et le PVC r\u00e9sistant \u00e0 la chaleur TI 3 \u00e0 90 \u00b0C. Il existe aussi des c\u00e2bles PVC r\u00e9sistants \u00e0 la chaleur, comme le <a href=\"https:\/\/tebaoflex-cable.com\/fr\/product\/tri-rated-cable-h07v2-k-bs6231\/\">fil de c\u00e2blage tri-rated H05V2-K \/ H07V2-K<\/a> donn\u00e9 pour 90 \u00b0C.<\/p>\n<p>L&#039;Am\u00e9rique du Nord ne fait pas exception. Notre fiche technique SOOW indique une plage de r\u00e9f\u00e9rence de \u221240 \u00e0 +90 \u00b0C pour ce cordon thermodurcissable, tandis que certains cordons thermoplastiques SJTOW sont list\u00e9s \u00e0 105 \u00b0C en milieu sec. La vraie diff\u00e9rence de temp\u00e9rature entre caoutchouc et PVC se situe du c\u00f4t\u00e9 froid, comme le montre le graphique.<\/p>\n<figure class=\"tebaoflex-tab-image tf-rvp-chart\">\n    <svg class=\"tbf-sys\" viewbox=\"0 0 760 368\" role=\"img\" aria-labelledby=\"rp-t\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><title id=\"rp-t\">Plages de temp\u00e9rature en service mobile publi\u00e9es sur six pages produits TEBAOFLEX : quatre c\u00e2bles PVC et deux c\u00e2bles caoutchouc. Le caoutchouc descend plus bas en flexion, mais le c\u00e2ble caoutchouc harmonis\u00e9 H07RN-F a une limite haute plus basse (60 \u00b0C) que le c\u00e2ble PVC H05VV-F (70 \u00b0C).<\/title><rect x=\"0\" y=\"0\" width=\"760\" height=\"368\" fill=\"#fff\"\/><line x1=\"250.0\" y1=\"58\" x2=\"250.0\" y2=\"298\" stroke=\"#e3e7eb\" stroke-width=\"1\"\/><text x=\"250.0\" y=\"52\" text-anchor=\"middle\" font-size=\"12\" fill=\"#16202b\">\u221250 \u00b0C<\/text><line x1=\"330.0\" y1=\"58\" x2=\"330.0\" y2=\"298\" stroke=\"#e3e7eb\" stroke-width=\"1\"\/><text x=\"330.0\" y=\"52\" text-anchor=\"middle\" font-size=\"12\" fill=\"#16202b\">\u221225 \u00b0C<\/text><line x1=\"410.0\" y1=\"58\" x2=\"410.0\" y2=\"298\" stroke=\"#e3e7eb\" stroke-width=\"1\"\/><text x=\"410.0\" y=\"52\" text-anchor=\"middle\" font-size=\"12\" fill=\"#16202b\">0 \u00b0C<\/text><line x1=\"490.0\" y1=\"58\" x2=\"490.0\" y2=\"298\" stroke=\"#e3e7eb\" stroke-width=\"1\"\/><text x=\"490.0\" y=\"52\" text-anchor=\"middle\" font-size=\"12\" fill=\"#16202b\">+25 \u00b0C<\/text><line x1=\"570.0\" y1=\"58\" x2=\"570.0\" y2=\"298\" stroke=\"#e3e7eb\" stroke-width=\"1\"\/><text x=\"570.0\" y=\"52\" text-anchor=\"middle\" font-size=\"12\" fill=\"#16202b\">+50 \u00b0C<\/text><line x1=\"650.0\" y1=\"58\" x2=\"650.0\" y2=\"298\" stroke=\"#e3e7eb\" stroke-width=\"1\"\/><text x=\"650.0\" y=\"52\" text-anchor=\"middle\" font-size=\"12\" fill=\"#16202b\">+75 \u00b0C<\/text><line x1=\"730.0\" y1=\"58\" x2=\"730.0\" y2=\"298\" stroke=\"#e3e7eb\" stroke-width=\"1\"\/><text x=\"730.0\" y=\"52\" text-anchor=\"middle\" font-size=\"12\" fill=\"#16202b\">+100 \u00b0C<\/text><line x1=\"410.0\" y1=\"58\" x2=\"410.0\" y2=\"298\" stroke=\"#3b4652\" stroke-width=\"1.2\" stroke-dasharray=\"4 4\"\/><text x=\"238\" y=\"92\" text-anchor=\"end\" font-size=\"13\" fill=\"#16202b\">H05VV-F 300\/500 V<\/text><rect x=\"394.0\" y=\"78\" width=\"240.0\" height=\"20\" rx=\"4\" fill=\"#9aa3ad\" stroke=\"#5f6a75\" stroke-width=\"1\"\/><text x=\"400.0\" y=\"93\" font-size=\"11.5\" fill=\"#fff\" font-weight=\"700\">\u22125<\/text><text x=\"628.0\" y=\"93\" text-anchor=\"end\" font-size=\"11.5\" fill=\"#fff\" font-weight=\"700\">+70<\/text><path d=\"M634.0 74 l6 -8 h-12 z\" fill=\"#c62828\"\/><text x=\"642.0\" y=\"74\" font-size=\"10.5\" fill=\"#c62828\">70<\/text><text x=\"238\" y=\"130\" text-anchor=\"end\" font-size=\"13\" fill=\"#16202b\">C\u00e2ble ascenseur plat H05VVH6-F<\/text><rect x=\"394.0\" y=\"116\" width=\"240.0\" height=\"20\" rx=\"4\" fill=\"#9aa3ad\" stroke=\"#5f6a75\" stroke-width=\"1\"\/><text x=\"400.0\" y=\"131\" font-size=\"11.5\" fill=\"#fff\" font-weight=\"700\">\u22125<\/text><text x=\"628.0\" y=\"131\" text-anchor=\"end\" font-size=\"11.5\" fill=\"#fff\" font-weight=\"700\">+70<\/text><text x=\"238\" y=\"168\" text-anchor=\"end\" font-size=\"13\" fill=\"#16202b\">C\u00e2ble PVC C800 pour enrouleur<\/text><rect x=\"378.0\" y=\"154\" width=\"224.0\" height=\"20\" rx=\"4\" fill=\"#9aa3ad\" stroke=\"#5f6a75\" stroke-width=\"1\"\/><text x=\"384.0\" y=\"169\" font-size=\"11.5\" fill=\"#fff\" font-weight=\"700\">\u221210<\/text><text x=\"596.0\" y=\"169\" text-anchor=\"end\" font-size=\"11.5\" fill=\"#fff\" font-weight=\"700\">+60<\/text><path d=\"M666.0 150 l6 -8 h-12 z\" fill=\"#c62828\"\/><text x=\"674.0\" y=\"150\" font-size=\"10.5\" fill=\"#c62828\">80<\/text><text x=\"238\" y=\"206\" text-anchor=\"end\" font-size=\"13\" fill=\"#16202b\">Guirlande plate PVC KYFLY<\/text><rect x=\"330.0\" y=\"192\" width=\"304.0\" height=\"20\" rx=\"4\" fill=\"#9aa3ad\" stroke=\"#5f6a75\" stroke-width=\"1\"\/><text x=\"336.0\" y=\"207\" font-size=\"11.5\" fill=\"#fff\" font-weight=\"700\">\u221225<\/text><text x=\"628.0\" y=\"207\" text-anchor=\"end\" font-size=\"11.5\" fill=\"#fff\" font-weight=\"700\">+70<\/text><path d=\"M634.0 188 l6 -8 h-12 z\" fill=\"#c62828\"\/><text x=\"642.0\" y=\"188\" font-size=\"10.5\" fill=\"#c62828\">70<\/text><text x=\"238\" y=\"244\" text-anchor=\"end\" font-size=\"13\" fill=\"#16202b\">H07RN-F 450\/750 V<\/text><rect x=\"330.0\" y=\"230\" width=\"272.0\" height=\"20\" rx=\"4\" fill=\"#1f7a5c\" stroke=\"#145a43\" stroke-width=\"1\"\/><text x=\"336.0\" y=\"245\" font-size=\"11.5\" fill=\"#fff\" font-weight=\"700\">\u221225<\/text><text x=\"596.0\" y=\"245\" text-anchor=\"end\" font-size=\"11.5\" fill=\"#fff\" font-weight=\"700\">+60<\/text><text x=\"238\" y=\"282\" text-anchor=\"end\" font-size=\"13\" fill=\"#16202b\">Guirlande plate caoutchouc NGFLGOEU<\/text><rect x=\"298.0\" y=\"268\" width=\"368.0\" height=\"20\" rx=\"4\" fill=\"#1f7a5c\" stroke=\"#145a43\" stroke-width=\"1\"\/><text x=\"304.0\" y=\"283\" font-size=\"11.5\" fill=\"#fff\" font-weight=\"700\">\u221235<\/text><text x=\"660.0\" y=\"283\" text-anchor=\"end\" font-size=\"11.5\" fill=\"#fff\" font-weight=\"700\">+80<\/text><path d=\"M698.0 264 l6 -8 h-12 z\" fill=\"#c62828\"\/><text x=\"706.0\" y=\"264\" font-size=\"10.5\" fill=\"#c62828\">90<\/text><rect x=\"250\" y=\"309\" width=\"16\" height=\"12\" rx=\"2\" fill=\"#9aa3ad\"\/><text x=\"272\" y=\"320\" font-size=\"12\" fill=\"#16202b\">PVC<\/text><rect x=\"320\" y=\"309\" width=\"16\" height=\"12\" rx=\"2\" fill=\"#1f7a5c\"\/><text x=\"342\" y=\"320\" font-size=\"12\" fill=\"#16202b\">Caoutchouc (EI4\/EM2 ou EPR\/CR)<\/text><path d=\"M256 340 l6 -8 h-12 z\" fill=\"#c62828\"\/><text x=\"272\" y=\"342\" font-size=\"12\" fill=\"#16202b\">temp\u00e9rature maximale de l&#039;\u00e2me, si la page l&#039;indique<\/text><\/svg><figcaption>Plage de temp\u00e9rature pour un service en mouvement ou en flexion et, lorsque la page l&#039;indique, temp\u00e9rature maximale de l&#039;\u00e2me, telles que publi\u00e9es sur six pages produits TEBAOFLEX. Valeurs de r\u00e9f\u00e9rence, et non r\u00e9sultats d&#039;essais.<\/figcaption><\/figure>\n<h2 id=\"cold-and-movement\">Quel c\u00e2ble reste souple dans le froid et sur les \u00e9quipements mobiles ?<\/h2>\n<p>Le c\u00e2ble caoutchouc ordinaire. Notre fiche technique H07RN-F autorise la flexion \u00e0 partir de \u221225 \u00b0C et notre c\u00e2ble guirlande caoutchouc NGFLGOEU \u00e0 partir de \u221235 \u00b0C, alors que le cordon PVC H05VV-F n&#039;est donn\u00e9 en flexion qu&#039;\u00e0 partir de \u22125 \u00b0C (\u221240 \u00b0C en pose fixe). Les limites basses proviennent des fiches techniques des fabricants, et non des normes harmonis\u00e9es : comparez donc les valeurs du c\u00e2ble que vous achetez.<\/p>\n<p>Cela ne signifie pas que le PVC ne peut pas bouger. Des grades de PVC sp\u00e9ciaux sont con\u00e7us pour le mouvement, dans leurs limites :<\/p>\n<ul>\n<li><a href=\"https:\/\/tebaoflex-cable.com\/fr\/product\/kyfly-pvc-flat-festoon-cable\/\">C\u00e2ble feston plat PVC KYFLY<\/a> fl\u00e9chit dans un seul plan \u00e0 partir de \u221225 \u00b0C sur les ponts roulants et les palans.<\/li>\n<li><a href=\"https:\/\/tebaoflex-cable.com\/fr\/product\/c800-pvc-reeling-cable\/\">C\u00e2ble d&#039;enroulement en PVC C800<\/a> fonctionne sur enrouleurs \u00e0 ressort \u00e0 partir de \u221210 \u00b0C avec un rayon de courbure dynamique de 8 \u00d7 D.<\/li>\n<li><a href=\"https:\/\/tebaoflex-cable.com\/fr\/product\/h05vvh6-f-h07vvh6-f-elevator-traveling-cable\/\">C\u00e2ble pendentif plat pour ascenseurs H05VVH6-F<\/a> est un c\u00e2ble PVC con\u00e7u pour \u00eatre suspendu et se d\u00e9placer dans une cage d&#039;ascenseur, en flexion \u00e0 partir de \u22125 \u00b0C.<\/li>\n<\/ul>\n<p>Le caoutchouc accepte aussi des courbures plus serr\u00e9es. Notre fiche technique H07RN-F indique 4 \u00e0 6 \u00d7 D en mouvement selon le diam\u00e8tre du c\u00e2ble, contre 7.5 \u00d7 D pour le H05VV-F en flexion. D&#039;autres fabricants publient des multiplicateurs diff\u00e9rents, et EN 50565-1 donne les recommandations harmonis\u00e9es : utilisez donc la valeur de la fiche technique du c\u00e2ble lui-m\u00eame pour dimensionner poulies, tambours et boucles.<\/p>\n<p>Pour convertir un multiplicateur en rayon pour un c\u00e2ble r\u00e9el, et pour les r\u00e8gles NEC et europ\u00e9ennes \u00e0 l&#039;origine de ces chiffres, consultez l&#039;article <a href=\"https:\/\/tebaoflex-cable.com\/fr\/cable-minimum-bending-radius\/\">comment calculer le rayon de courbure d&#039;un c\u00e2ble<\/a>, qui comprend des exemples de calcul pour le H07RN-F et le Type W.<\/p>\n<p>Aucune norme ne publie de classement de dur\u00e9e de vie en flexion du caoutchouc par rapport au PVC. Chaque type harmonis\u00e9 doit r\u00e9ussir ses propres essais de flexion, de courbure et de pliage, aujourd&#039;hui regroup\u00e9s dans IEC 63294, et les nombres de cycles obtenus lors de l&#039;essai d&#039;un fabricant ne se transposent pas au c\u00e2ble d&#039;un autre.<\/p>\n<h2 id=\"environment\">Huile, ozone, usage en ext\u00e9rieur, eau et abrasion<\/h2>\n<p>C&#039;est surtout la gaine qui en d\u00e9cide. Les gaines r\u00e9ticul\u00e9es comme le m\u00e9lange EM 2 du H07RN-F sont test\u00e9es pour la r\u00e9sistance \u00e0 l&#039;huile min\u00e9rale (IEC 60811-404) et au craquelage \u00e0 l&#039;ozone (IEC 60811-403), l&#039;essai appliqu\u00e9 aux m\u00e9langes r\u00e9ticul\u00e9s. C&#039;est pourquoi le H07RN-F s&#039;utilise en ext\u00e9rieur, sur les chantiers et avec les machines agricoles et industrielles, alors que notre fiche technique H05VV-F pr\u00e9cise clairement qu&#039;il n&#039;est pas destin\u00e9 \u00e0 une installation en ext\u00e9rieur.<\/p>\n<p>Des m\u00e9langes de gainage PVC r\u00e9sistants \u00e0 l&#039;huile existent (TM 5 dans EN 50363-4-1) et conviennent aux c\u00e2bles de commande \u00e0 l&#039;int\u00e9rieur des machines, mais ils ne transforment pas un cordon PVC l\u00e9ger en c\u00e2ble pour l&#039;ext\u00e9rieur ou les chantiers.<\/p>\n<p>Pour l&#039;eau, distinguez les locaux mouill\u00e9s de l&#039;immersion. Le H07RN-F convient aux locaux humides et mouill\u00e9s ; pour les c\u00e2bles qui passent sous l&#039;eau, EN 50525-2-21 pr\u00e9voit un type distinct r\u00e9sistant \u00e0 l&#039;eau, le <a href=\"https:\/\/tebaoflex-cable.com\/fr\/product\/h07rn8-f-cable\/\">H07RN8-F pour pompes immerg\u00e9es<\/a>, que notre fiche technique donne pour l&#039;eau douce jusqu&#039;\u00e0 10 m de profondeur et 40 \u00b0C.<\/p>\n<p>Pour les services lourds, les gaines en caoutchouc sont choisies pour leur r\u00e9sistance \u00e0 la d\u00e9chirure et \u00e0 l&#039;abrasion l\u00e0 o\u00f9 les c\u00e2bles sont tra\u00een\u00e9s sur le b\u00e9ton et le gravier. Les normes v\u00e9rifient l&#039;usure par un essai plut\u00f4t que de classer les mat\u00e9riaux : si l&#039;abrasion est le risque principal, indiquez-le dans la demande ; une gaine plus \u00e9paisse ou en polyur\u00e9thane peut mieux convenir que l&#039;un ou l&#039;autre des types de base.<\/p>\n<h2 id=\"fire\">Comment les c\u00e2bles caoutchouc et PVC se comportent-ils au feu ?<\/h2>\n<p>Les deux types ordinaires sont non propagateurs de la flamme selon IEC 60332-1-2, l&#039;essai sur c\u00e2ble vertical isol\u00e9, et tous deux contiennent du chlore. Le PVC d\u00e9gage du chlorure d&#039;hydrog\u00e8ne en br\u00fblant : <a href=\"https:\/\/pmc.ncbi.nlm.nih.gov\/articles\/PMC7084980\/\" target=\"_blank\" rel=\"noopener\">une \u00e9tude \u00e9valu\u00e9e par les pairs sur la combustion de fils de cuivre isol\u00e9s au PVC<\/a> a mesur\u00e9 environ 0.3 g de HCl par gramme de fil. Le polychloropr\u00e8ne, le N de H07RN-F, contient environ 40 % de chlore en masse, et les gaines ext\u00e9rieures CPE sont chlor\u00e9es par d\u00e9finition : un c\u00e2ble caoutchouc n&#039;est donc pas automatiquement sans halog\u00e8ne.<\/p>\n<p>\u00c9tant thermodurcissable, une gaine en caoutchouc se carbonise au lieu de fondre, ce qui aide l\u00e0 o\u00f9 un c\u00e2ble peut toucher des surfaces chaudes, mais ce n&#039;est pas une classification au feu. Si la sp\u00e9cification exige une faible \u00e9mission de fum\u00e9e, z\u00e9ro halog\u00e8ne, commandez un c\u00e2ble construit et test\u00e9 pour cela, comme le type H07ZZ-F sans halog\u00e8ne \u00e0 faible \u00e9mission de fum\u00e9e de EN 50525-3-21. Non-propagation de la flamme, faible \u00e9mission de fum\u00e9e et maintien de la fonction sont trois essais diff\u00e9rents, comme notre <a href=\"https:\/\/tebaoflex-cable.com\/fr\/cases\/shielded-speaker-cable-2x2-5mm2-voice-evacuation-philippines\/\">dossier de projet sur un c\u00e2ble d&#039;\u00e9vacuation vocale<\/a> l&#039;explique.<\/p>\n<h2 id=\"size-and-cost\">Taille, poids et co\u00fbt<\/h2>\n<p>\u00c0 conducteurs et section identiques, le c\u00e2ble caoutchouc est plus \u00e9pais et plus lourd que le c\u00e2ble PVC, et le c\u00e2ble PVC co\u00fbte moins cher au m\u00e8tre. Une partie de l&#039;\u00e9cart de taille vient de la classe de tension : le H07RN-F est un c\u00e2ble 450\/750 V aux parois plus \u00e9paisses que le H05VV-F 300\/500 V.<\/p>\n<table>\n<caption>Diam\u00e8tre ext\u00e9rieur et poids selon les fiches techniques TEBAOFLEX<\/caption>\n<thead>\n<tr>\n<th scope=\"col\">Taille<\/th>\n<th scope=\"col\">H07RN-F<\/th>\n<th scope=\"col\">H05VV-F<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>3G1.5 mm\u00b2<\/td>\n<td>10 mm, 170 kg\/km<\/td>\n<td>8.0 mm, environ 101 kg\/km<\/td>\n<\/tr>\n<tr>\n<td>3G2.5 mm\u00b2<\/td>\n<td>12 mm, 230 kg\/km<\/td>\n<td>9.9 mm, environ 156 kg\/km<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Cet avantage de prix fait du PVC le choix habituel pour les cordons d&#039;appareils. Ne comparez les prix qu&#039;entre des c\u00e2bles tous deux adapt\u00e9s au service : un cordon PVC utilis\u00e9 hors de ses limites de temp\u00e9rature ou d&#039;usage en ext\u00e9rieur n&#039;est pas un \u00e9quivalent moins cher d&#039;un cordon caoutchouc.<\/p>\n<h2 id=\"choose\">C\u00e2ble caoutchouc ou PVC : lequel choisir ?<\/h2>\n<p>Choisissez le c\u00e2ble caoutchouc ou PVC selon le service : caoutchouc pour un service en mouvement, en ext\u00e9rieur, avec huile ou dans le froid, PVC pour les raccordements l\u00e9gers, secs et int\u00e9rieurs. Le tableau ci-dessous part de l&#039;application, et non du mat\u00e9riau, et indique ce qu&#039;il faut v\u00e9rifier sur la fiche technique avant de commander.<\/p>\n<table>\n<caption>Caoutchouc ou PVC selon l&#039;application<\/caption>\n<thead>\n<tr>\n<th scope=\"col\">Application<\/th>\n<th scope=\"col\">Choix habituel<\/th>\n<th scope=\"col\">\u00c0 v\u00e9rifier avant commande<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Cordon d&#039;appareil, raccordement int\u00e9rieur l\u00e9ger<\/td>\n<td>PVC, H05VV-F<\/td>\n<td>Pas d&#039;usage en ext\u00e9rieur, pas de flexion sous \u22125 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Outils \u00e9lectriques, ateliers, chantiers, alimentation temporaire<\/td>\n<td>Caoutchouc, H07RN-F<\/td>\n<td>Limite de 60 \u00b0C \u00e0 l&#039;\u00e2me, intensit\u00e9 admissible selon la section<\/td>\n<\/tr>\n<tr>\n<td>Pompes immerg\u00e9es et c\u00e2bles immerg\u00e9s<\/td>\n<td>Caoutchouc, H07RN8-F<\/td>\n<td>Type d&#039;eau, profondeur et temp\u00e9rature<\/td>\n<\/tr>\n<tr>\n<td>Guirlandes de ponts roulants et palans, en ext\u00e9rieur ou dans le froid<\/td>\n<td>Caoutchouc, NGFLGOEU<\/td>\n<td>Vitesse de d\u00e9placement, longueur de boucle, disposition des conducteurs isol\u00e9s<\/td>\n<\/tr>\n<tr>\n<td>Guirlandes int\u00e9rieures dans un seul plan<\/td>\n<td>PVC, KYFLY<\/td>\n<td>Limite en mouvement \u221225 \u00b0C, nombre de conducteurs isol\u00e9s<\/td>\n<\/tr>\n<tr>\n<td>Enrouleurs \u00e0 ressort sur machines compactes<\/td>\n<td>PVC, C800<\/td>\n<td>Limite \u221210 \u00b0C, 8 \u00d7 D sur l&#039;enrouleur<\/td>\n<\/tr>\n<tr>\n<td>C\u00e2ble pendentif pour ascenseurs<\/td>\n<td>PVC, H05VVH6-F<\/td>\n<td>Longueur suspendue, nombre de conducteurs isol\u00e9s<\/td>\n<\/tr>\n<tr>\n<td>Cordons portables nord-am\u00e9ricains<\/td>\n<td>Caoutchouc, <a href=\"https:\/\/tebaoflex-cable.com\/fr\/product\/sjoow-cable-300v-portable-power\/\">SJOOW<\/a> (300 V) ou SOOW (600 V)<\/td>\n<td>Tension, AWG, exposition \u00e0 l&#039;huile et \u00e0 l&#039;ext\u00e9rieur<\/td>\n<\/tr>\n<tr>\n<td>C\u00e2bles tra\u00eenants d&#039;\u00e9quipements miniers<\/td>\n<td>Caoutchouc, par exemple <a href=\"https:\/\/tebaoflex-cable.com\/fr\/product\/type-g-gc-cable-2000v\/\">Type G-GC<\/a><\/td>\n<td>Tension, conducteur de contr\u00f4le de terre, gaine ext\u00e9rieure<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Pour la famille caoutchouc, TEBAOFLEX d\u00e9tient le certificat VDE 40060056 pour les c\u00e2bles souples isol\u00e9s en \u00e9lastom\u00e8re r\u00e9ticul\u00e9 selon EN 50525-2-21, la norme dont rel\u00e8ve le H07RN-F. Ses cordons SOOW et SJOOW sont certifi\u00e9s UL 62 dans la cat\u00e9gorie ZJCZ (Flexible Cord), certificat UL-US-2449012-4. Pour une vue d&#039;ensemble du H07RN-F, consultez notre <a href=\"https:\/\/tebaoflex-cable.com\/fr\/h07rn-f-cable-guide\/\">guide du c\u00e2ble caoutchouc H07RN-F<\/a>.<\/p>\n<h2 id=\"quote\">Ce qu&#039;il faut envoyer pour obtenir une offre<\/h2>\n<p>&#8220;C\u00e2ble caoutchouc&#8221; ou &#8220;c\u00e2ble PVC&#8221; ne suffit pas pour \u00e9tablir une offre. Envoyez :<\/p>\n<ul>\n<li>D\u00e9signation ou construction, s&#039;il s&#039;agit de remplacer un c\u00e2ble existant<\/li>\n<li>Tension, nombre de conducteurs isol\u00e9s et section<\/li>\n<li>Service : fixe, mouvement occasionnel, guirlande, enrouleur ou tra\u00eenage<\/li>\n<li>Temp\u00e9ratures ambiantes minimale et maximale sur le site<\/li>\n<li>Exposition : ext\u00e9rieur, huile, eau, abrasion<\/li>\n<li>Exigences au feu, le cas \u00e9ch\u00e9ant : non-propagation de la flamme, faible \u00e9mission de fum\u00e9e et z\u00e9ro halog\u00e8ne<\/li>\n<li>Longueur par coupe et quantit\u00e9 totale<\/li>\n<\/ul>\n<p>En date d&#039;ao\u00fbt 2026, la commande minimale est de 50 m pour les constructions standard comme sur mesure, et le d\u00e9lai va de 7 \u00e0 45 jours ouvrables selon le type de produit, l&#039;\u00e9tat des stocks et la personnalisation. <a href=\"https:\/\/tebaoflex-cable.com\/fr\/contact-us\/#request-quote\">Envoyez les donn\u00e9es de service et de site pour qu&#039;on vous propose le bon c\u00e2ble<\/a>&nbsp;; le devis \u00e9crit indique la construction et le d\u00e9lai.<\/p>\n<h2 id=\"faq\">Questions<\/h2>\n<h3>Le c\u00e2ble caoutchouc est-il meilleur que le c\u00e2ble PVC ?<\/h3>\n<p>Le c\u00e2ble caoutchouc est meilleur pour un service en mouvement, en ext\u00e9rieur, en pr\u00e9sence d&#039;huile et dans le froid ; le c\u00e2ble PVC offre un meilleur rapport qualit\u00e9-prix pour les raccordements l\u00e9gers, secs et int\u00e9rieurs. Le caoutchouc ordinaire n&#039;est pas meilleur en temp\u00e9rature : le H07RN-F est donn\u00e9 pour 60 \u00b0C \u00e0 l&#039;\u00e2me contre 70 \u00b0C pour le H05VV-F (EN 50525-2-21 et EN 50525-2-11).<\/p>\n<h3>Le c\u00e2ble PVC peut-il servir en ext\u00e9rieur ?<\/h3>\n<p>Le cordon PVC H05VV-F standard n&#039;est pas destin\u00e9 \u00e0 une installation en ext\u00e9rieur. Pour l&#039;ext\u00e9rieur et les chantiers, choisissez un cordon caoutchouc comme le H07RN-F, ou un c\u00e2ble dont la norme et la fiche technique autorisent l&#039;usage en ext\u00e9rieur.<\/p>\n<h3>Le c\u00e2ble caoutchouc est-il \u00e9tanche ?<\/h3>\n<p>Le H07RN-F convient aux locaux humides et mouill\u00e9s, mais ce n&#039;est pas un c\u00e2ble pour immersion. Pour les c\u00e2bles qui passent sous l&#039;eau, utilisez le type H07RN8-F r\u00e9sistant \u00e0 l&#039;eau, que notre fiche technique donne pour l&#039;eau douce jusqu&#039;\u00e0 10 m de profondeur et 40 \u00b0C.<\/p>\n<h3>Le c\u00e2ble caoutchouc est-il sans halog\u00e8ne ?<\/h3>\n<p>Pas n\u00e9cessairement. Les gaines en polychloropr\u00e8ne (CR) et en CPE contiennent du chlore, comme le PVC. Un c\u00e2ble sans halog\u00e8ne \u00e0 faible \u00e9mission de fum\u00e9e est une construction distincte, comme le type H07ZZ-F de EN 50525-3-21.<\/p>\n<h3>Que signifient R, N et V dans H07RN-F et H05VV-F ?<\/h3>\n<p>R d\u00e9signe l&#039;isolation caoutchouc, N une gaine en polychloropr\u00e8ne et V le PVC : le H07RN-F est donc un c\u00e2ble caoutchouc \u00e0 gaine en chloropr\u00e8ne, et le H05VV-F a une isolation PVC et une gaine PVC. Les chiffres 07 et 05 indiquent la classe de tension : 450\/750 V et 300\/500 V.<\/p>\n<\/article>","protected":false},"excerpt":{"rendered":"<p>Le c\u00e2ble caoutchouc n&#039;est pas toujours donn\u00e9 pour une temp\u00e9rature plus \u00e9lev\u00e9e que le PVC. En quoi le H07RN-F et le H05VV-F diff\u00e8rent en flexion \u00e0 froid, huile, usage en ext\u00e9rieur, feu, taille et prix, et lequel choisir pour chaque service.<\/p>","protected":false},"author":1,"featured_media":5684,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[621],"tags":[],"class_list":["post-5686","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-cable-selection-engineering-guides"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/tebaoflex-cable.com\/fr\/wp-json\/wp\/v2\/posts\/5686","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/tebaoflex-cable.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/tebaoflex-cable.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/tebaoflex-cable.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/tebaoflex-cable.com\/fr\/wp-json\/wp\/v2\/comments?post=5686"}],"version-history":[{"count":3,"href":"https:\/\/tebaoflex-cable.com\/fr\/wp-json\/wp\/v2\/posts\/5686\/revisions"}],"predecessor-version":[{"id":5799,"href":"https:\/\/tebaoflex-cable.com\/fr\/wp-json\/wp\/v2\/posts\/5686\/revisions\/5799"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/tebaoflex-cable.com\/fr\/wp-json\/wp\/v2\/media\/5684"}],"wp:attachment":[{"href":"https:\/\/tebaoflex-cable.com\/fr\/wp-json\/wp\/v2\/media?parent=5686"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/tebaoflex-cable.com\/fr\/wp-json\/wp\/v2\/categories?post=5686"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/tebaoflex-cable.com\/fr\/wp-json\/wp\/v2\/tags?post=5686"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}