{"id":6463,"date":"2026-10-28T10:21:09","date_gmt":"2026-10-28T02:21:09","guid":{"rendered":"https:\/\/tebaoflex-cable.com\/?p=6463"},"modified":"2026-10-30T09:21:12","modified_gmt":"2026-10-30T01:21:12","slug":"conductor-stranding-classes","status":"publish","type":"post","link":"https:\/\/tebaoflex-cable.com\/fr\/conductor-stranding-classes\/","title":{"rendered":"C\u00e2blage des \u00e2mes de c\u00e2bles industriels : classe K (Class K), classe 5 et classe 6"},"content":{"rendered":"<div class=\"tf-csc-page\">\n<p>Le c\u00e2blage classe K est une d\u00e9signation d&#039;\u00e2me \u00e0 brins fins utilis\u00e9e dans les sp\u00e9cifications nord-am\u00e9ricaines. Dans une construction <a href=\"https:\/\/store.astm.org\/standards\/b172\" rel=\"nofollow noopener\" target=\"_blank\">ASTM B172<\/a> c\u00e2bl\u00e9e en corde (rope-lay), la classe K utilise des brins constitutifs de 30 AWG nominal ; les classes 5 et 6 de l&#039;IEC ob\u00e9issent \u00e0 des d\u00e9finitions diff\u00e9rentes et ne sont pas des \u00e9quivalents automatiques.<\/p>\n<p>Pour les c\u00e2bles de soudage, les c\u00e2bles d&#039;alimentation en caoutchouc, les c\u00e2bles d&#039;enroulement et le c\u00e2blage en cha\u00eene porte-c\u00e2bles, sp\u00e9cifiez la classe d&#039;\u00e2me, puis v\u00e9rifiez s\u00e9par\u00e9ment le service du c\u00e2ble complet et les bornes. Une \u00e2me \u00e0 brins plus fins n&#039;\u00e9tablit pas, \u00e0 elle seule, un rayon de courbure admissible plus faible ni une dur\u00e9e de vie plus longue du c\u00e2ble.<\/p>\n<nav class=\"tf-csc-toc\" aria-label=\"Sur cette page\"><strong>Sur cette page<\/strong><\/p>\n<ol>\n<li><a href=\"#read-the-conductor-construction-before-comparing-classes\">Construction du conducteur<\/a><\/li>\n<li><a href=\"#iec-conductor-classes-1-2-5-and-6\">Classes IEC<\/a><\/li>\n<li><a href=\"#class-b-class-k-and-class-m-identify-the-astm-construction\">Classes ASTM<\/a><\/li>\n<li><a href=\"#is-class-k-equivalent-to-iec-class-5\">Classe K et classe 5<\/a><\/li>\n<li><a href=\"#apply-the-classes-to-the-industrial-cable-application\">Applications industrielles<\/a><\/li>\n<li><a href=\"#a-conductor-class-is-not-a-continuous-flex-rating\">Service en mouvement<\/a><\/li>\n<li><a href=\"#match-fine-stranded-conductors-to-their-terminals\">Terminaisons<\/a><\/li>\n<li><a href=\"#write-an-enquiry-that-keeps-size-class-and-duty-together\">R\u00e9diger la sp\u00e9cification<\/a><\/li>\n<\/ol>\n<\/nav>\n<h2 id=\"read-the-conductor-construction-before-comparing-classes\">Lisez la construction de l&#039;\u00e2me avant de comparer les classes<\/h2>\n<p>Une \u00e2me est l&#039;assemblage m\u00e9tallique qui transporte le courant. Un brin \u00e9l\u00e9mentaire est un composant de cet assemblage ; un faisceau ou un toron est un groupe de brins. L&#039;isolation entoure l&#039;\u00e2me pour former un conducteur isol\u00e9, tandis qu&#039;un c\u00e2ble multiconducteur r\u00e9unit plusieurs conducteurs isol\u00e9s avec ses autres couches sp\u00e9cifi\u00e9es.<\/p>\n<p>Ces distinctions comptent \u00e0 la lecture d&#039;une description de c\u00e2blage. Une section globale d&#039;\u00e2me en AWG ou en mm\u00b2 est diff\u00e9rente de la taille de chaque brin constitutif. Un plan peut aussi montrer plusieurs torons c\u00e2bl\u00e9s en faisceau assembl\u00e9s en une \u00e2me c\u00e2bl\u00e9e en corde, plut\u00f4t qu&#039;un seul faisceau non divis\u00e9.<\/p>\n<figure class=\"tf-csc-portrait\"><img loading=\"lazy\" alt=\"Brins de cuivre nu assembl\u00e9s en groupes plus grands, l&#039;extr\u00e9mit\u00e9 de l&#039;\u00e9chantillon maintenue par un ruban rouge\" decoding=\"async\" height=\"1333\" src=\"https:\/\/tebaoflex-cable.com\/wp-content\/uploads\/2026\/10\/bare-copper-conductor-strand-groups.webp\" width=\"1000\"\/><figcaption>Un \u00e9chantillon d&#039;\u00e2me en cuivre nu montre des brins \u00e9l\u00e9mentaires assembl\u00e9s en groupes plus grands. La composition des brins indique comment ces groupes forment l&#039;\u00e2me compl\u00e8te.<\/figcaption><\/figure>\n<p>Demandez la description r\u00e9elle de la construction lorsque la distinction a une incidence sur une commande. Les termes \u00ab \u00e0 brins fins \u00bb et \u00ab extra-souple \u00bb sont des descriptions utiles, mais ils ne remplacent pas une norme et une classe d\u00e9clar\u00e9es.<\/p>\n<h2 id=\"iec-conductor-classes-1-2-5-and-6\">Classes d&#039;\u00e2me IEC 1, 2, 5 et 6<\/h2>\n<p>L&#039;IEC 60228 distingue les \u00e2mes massives et c\u00e2bl\u00e9es des c\u00e2bles pour installation fixe des \u00e2mes souples des c\u00e2bles et cordons. Sa classification actuelle d\u00e9finit la classe 6 par des brins \u00e9l\u00e9mentaires plus petits que ceux de la classe 5 \u00e0 section nominale \u00e9gale. Les exigences relatives aux \u00e2mes comprennent des limites de diam\u00e8tre des brins \u00e9l\u00e9mentaires et de r\u00e9sistance ; elles ne constituent pas une sp\u00e9cification compl\u00e8te du mouvement du c\u00e2ble. Voir la norme <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/71891\" rel=\"nofollow noopener\" target=\"_blank\">IEC 60228:2023<\/a>.<\/p>\n<div aria-label=\"Tableau comparatif des \u00e2mes\" class=\"tf-csc-table\" role=\"region\" tabindex=\"0\">\n<table>\n<thead>\n<tr>\n<th scope=\"col\">Classe IEC<\/th>\n<th scope=\"col\">Description de l&#039;\u00e2me<\/th>\n<th scope=\"col\">Incidence sur le choix<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">Classe 1<\/th>\n<td>\u00c2me massive<\/td>\n<td>V\u00e9rifiez les exigences sp\u00e9cifi\u00e9es du c\u00e2ble pour installation fixe et du raccordement<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Classe 2<\/th>\n<td>\u00c2me c\u00e2bl\u00e9e<\/td>\n<td>Plusieurs brins ne font pas automatiquement d&#039;une \u00e2me une construction souple de classe 5 ou 6<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Classe 5<\/th>\n<td>conducteur flexible<\/td>\n<td>V\u00e9rifiez les exigences relatives \u00e0 l&#039;\u00e2me pour la section choisie et le service du c\u00e2ble complet<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Classe 6<\/th>\n<td>\u00c2me souple \u00e0 brins \u00e9l\u00e9mentaires plus petits que ceux de la classe 5 \u00e0 section nominale \u00e9gale<\/td>\n<td>Confirmez la construction r\u00e9elle ; n&#039;en d\u00e9duisez ni un classement pour porte-c\u00e2bles ni une valeur de dur\u00e9e de vie<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>Les classes 5 et 6 peuvent aussi \u00eatre utilis\u00e9es en installation fixe. La norme ne prescrit pas un nombre de brins universel pour toutes les \u00e2mes d&#039;une section nominale donn\u00e9e. La composition des brins d&#039;un fournisseur doit \u00eatre v\u00e9rifi\u00e9e par rapport aux exigences applicables, plut\u00f4t que d&#039;\u00eatre consid\u00e9r\u00e9e comme la seule construction possible.<\/p>\n<p>La classe n&#039;\u00e9tablit pas non plus la finition du cuivre. Le cuivre nu et le cuivre \u00e0 rev\u00eatement m\u00e9tallique sont des choix de sp\u00e9cification distincts. <a href=\"https:\/\/tebaoflex-cable.com\/fr\/tinned-copper-vs-bare-copper\/\">Le guide sur le cuivre \u00e9tam\u00e9 et le cuivre nu<\/a> explique ce choix de mat\u00e9riau ; une photographie de couleur argent\u00e9e ne constitue pas, \u00e0 elle seule, un certificat de finition de l&#039;\u00e2me.<\/p>\n<h2 id=\"class-b-class-k-and-class-m-identify-the-astm-construction\">Classe B, classe K et classe M : identifiez la construction ASTM<\/h2>\n<p>Les classes nord-am\u00e9ricaines d\u00e9sign\u00e9es par une lettre exigent leur norme de construction de r\u00e9f\u00e9rence. <a href=\"https:\/\/store.astm.org\/b0008-23.html\" rel=\"nofollow noopener\" target=\"_blank\">ASTM B8<\/a> couvre les \u00e2mes en cuivre c\u00e2bl\u00e9es concentriques, y compris la classe B. <a href=\"https:\/\/store.astm.org\/standards\/b174\" rel=\"nofollow noopener\" target=\"_blank\">ASTM B174<\/a> couvre le cuivre c\u00e2bl\u00e9 en faisceau, tandis que l&#039;ASTM B172 couvre les \u00e2mes c\u00e2bl\u00e9es en corde assembl\u00e9es \u00e0 partir de torons c\u00e2bl\u00e9s en faisceau.<\/p>\n<p>La classe K et la classe M ne d\u00e9crivent pas un calibre global d&#039;\u00e2me. L&#039;ASTM B172 associe la classe M \u00e0 des brins constitutifs de 34 AWG nominal, plus fins que les brins de 30 AWG associ\u00e9s \u00e0 la classe K. Il s&#039;agit de tailles de brins \u00e9l\u00e9mentaires, et non de la taille AWG de l&#039;\u00e2me compl\u00e8te ni d&#039;un nombre total de brins universel.<\/p>\n<p>Deux \u00e2mes d\u00e9crites comme de classe K peuvent donc tout de m\u00eame exiger des compositions de brins et des d\u00e9tails de construction diff\u00e9rents selon la section. Confirmez si la commande porte sur un assemblage c\u00e2bl\u00e9 en faisceau ou c\u00e2bl\u00e9 en corde, ainsi que la norme applicable et la section r\u00e9elle de l&#039;\u00e2me. Ne copiez pas dans la demande une ligne de nombre de brins provenant d&#039;une autre construction de c\u00e2ble.<\/p>\n<p>Les classes B, K et M ne constituent pas non plus une \u00e9chelle de qualit\u00e9 num\u00e9rique unique. Une d\u00e9signation de classe devient utile lorsqu&#039;elle est rattach\u00e9e \u00e0 la construction de l&#039;\u00e2me et \u00e0 l&#039;application dont l&#039;acheteur a r\u00e9ellement besoin.<\/p>\n<h2 id=\"is-class-k-equivalent-to-iec-class-5\">La classe K est-elle \u00e9quivalente \u00e0 la classe 5 de l&#039;IEC ?<\/h2>\n<p>Les d\u00e9signations n&#039;\u00e9tablissent aucune \u00e9quivalence automatique. La classe K et la classe 5 de l&#039;IEC appartiennent \u00e0 des syst\u00e8mes de sp\u00e9cification diff\u00e9rents ; la m\u00eame prudence s&#039;applique \u00e0 la classe M et \u00e0 la classe 6 de l&#039;IEC. Une \u00e2me donn\u00e9e peut satisfaire \u00e0 plus d&#039;une sp\u00e9cification, mais cela exige des preuves pour la construction choisie.<\/p>\n<p>Une comparaison des sections en AWG et en mm\u00b2 ne l\u00e8ve pas la diff\u00e9rence. V\u00e9rifiez la section nominale, la construction des brins constitutifs, la finition du cuivre et les exigences applicables \u00e0 l&#039;\u00e2me au regard de chaque sp\u00e9cification revendiqu\u00e9e. Une offre indiquant les deux classes doit pr\u00e9ciser ce qui \u00e9taye les deux d\u00e9clarations.<\/p>\n<p>C&#039;est particuli\u00e8rement important lors du remplacement d&#039;un c\u00e2ble import\u00e9. Faire correspondre la section approximative de l&#039;\u00e2me, la couleur de la gaine et le mot \u00ab souple \u00bb laisse sans r\u00e9ponse la sp\u00e9cification de l&#039;\u00e2me, le service du c\u00e2ble fini et l&#039;acceptation par la borne.<\/p>\n<h2 id=\"apply-the-classes-to-the-industrial-cable-application\">Appliquez les classes \u00e0 l&#039;application industrielle du c\u00e2ble<\/h2>\n<p>Partez de la description r\u00e9elle du produit. Les pages produits actuelles de TEBAOFLEX illustrent plusieurs d\u00e9clarations d&#039;\u00e2me diff\u00e9rentes ; elles n&#039;attribuent pas une classe unique \u00e0 chaque c\u00e2ble de soudage, c\u00e2ble en caoutchouc ou c\u00e2ble mobile.<\/p>\n<div aria-label=\"Tableau comparatif des \u00e2mes\" class=\"tf-csc-table\" role=\"region\" tabindex=\"0\">\n<table>\n<thead>\n<tr>\n<th scope=\"col\">Application et page produit<\/th>\n<th scope=\"col\">Description publi\u00e9e de l&#039;\u00e2me<\/th>\n<th scope=\"col\">\u00c0 confirmer pour la commande<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\"><a href=\"https:\/\/tebaoflex-cable.com\/fr\/product\/wct-cable\/\">C\u00e2ble de soudage WCT<\/a><\/th>\n<td>Cuivre recuit c\u00e2bl\u00e9 ; la page ne d\u00e9clare ni K, ni M, ni 5, ni 6<\/td>\n<td>Composition r\u00e9elle des brins, sp\u00e9cification de r\u00e9f\u00e9rence, section de l&#039;\u00e2me et service du c\u00e2ble de soudage<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\"><a href=\"https:\/\/tebaoflex-cable.com\/fr\/product\/soow-cable-600v-epdm-cpe\/\">Cordon d&#039;alimentation portable SOOW<\/a><\/th>\n<td>R\u00e9f\u00e9rence \u00e0 la classe K<\/td>\n<td>Section choisie, disposition en faisceau ou en corde, norme de construction de r\u00e9f\u00e9rence et exigences du cordon<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\"><a href=\"https:\/\/tebaoflex-cable.com\/fr\/product\/h07rn-f-cable\/\">C\u00e2ble souple en caoutchouc H07RN-F<\/a><\/th>\n<td>R\u00e9f\u00e9rence \u00e0 la classe 5 selon EN\/IEC 60228<\/td>\n<td>Section command\u00e9e, finition du cuivre, conditions d&#039;installation et mouvement admissible<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\"><a href=\"https:\/\/tebaoflex-cable.com\/fr\/product\/ntscgewoeu-mv-crane-reeling-cable\/\">C\u00e2ble d&#039;enroulement pour grues NTSCGEWOU<\/a><\/th>\n<td>R\u00e9f\u00e9rence \u00e0 la classe 5<\/td>\n<td>G\u00e9om\u00e9trie du tambour et des poulies, effort de traction, torsion, disposition des conducteurs isol\u00e9s et syst\u00e8me de gaine complet<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\"><a href=\"https:\/\/tebaoflex-cable.com\/fr\/product\/servo-encoder-feedback-cable\/\">C\u00e2ble de retour codeur pour servomoteur<\/a><\/th>\n<td>R\u00e9f\u00e9rence \u00e0 la classe 6 pour les constructions de retour indiqu\u00e9es<\/td>\n<td>Configuration des signaux, \u00e9cran, conditions en porte-c\u00e2bles et variante exacte choisie<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>Pour les demandes concernant le soudage, ne transposez pas directement le nom de l&#039;application en classe K. <a href=\"https:\/\/tebaoflex-cable.com\/fr\/product\/h01n2-d-h01n2-e-welding-cable\/\">La page relative aux c\u00e2bles de soudage H01N2-D \/ H01N2-E<\/a> d\u00e9crit diff\u00e9rents types de souplesse, mais ses suffixes D\/E ne doivent pas servir de conversion pr\u00e9sum\u00e9e en classe 5\/classe 6. Demandez la construction d&#039;\u00e2me sp\u00e9cifi\u00e9e pour le c\u00e2ble de soudage concern\u00e9.<\/p>\n<p>L&#039;exemple SOOW n\u00e9cessite lui aussi sa construction propre \u00e0 la section. Sa description publique distingue les dispositions c\u00e2bl\u00e9es en faisceau et c\u00e2bl\u00e9es en corde ; la d\u00e9signation classe K ne d\u00e9termine pas \u00e0 elle seule quelle disposition ou quelle norme s&#039;applique \u00e0 la section choisie.<\/p>\n<p>Pour le c\u00e2blage en cha\u00eene porte-c\u00e2bles, l&#039;exemple de retour codeur rel\u00e8ve des c\u00e2bles de signal. Il n&#039;\u00e9tablit pas l&#039;aptitude au circuit de puissance d&#039;un servomoteur et ne montre pas que tout c\u00e2ble pour cha\u00eene porte-c\u00e2bles doit utiliser la classe 6.<\/p>\n<figure class=\"tf-csc-portrait\"><img loading=\"lazy\" alt=\"Extr\u00e9mit\u00e9 coup\u00e9e d&#039;un c\u00e2ble \u00e0 quatre conducteurs sous gaine caoutchouc montrant le cuivre c\u00e2bl\u00e9 \u00e0 l&#039;int\u00e9rieur des conducteurs isol\u00e9s\" decoding=\"async\" height=\"1333\" src=\"https:\/\/tebaoflex-cable.com\/wp-content\/uploads\/2026\/10\/rubber-cable-four-core-stranded-conductors.webp\" width=\"1000\"\/><figcaption>Un \u00e9chantillon de c\u00e2ble en caoutchouc \u00e0 quatre conducteurs montre des \u00e2mes c\u00e2bl\u00e9es dans leur isolation et sous la gaine ext\u00e9rieure. Ces couches doivent \u00eatre sp\u00e9cifi\u00e9es ensemble pour l&#039;application pr\u00e9vue.<\/figcaption><\/figure>\n<h2 id=\"a-conductor-class-is-not-a-continuous-flex-rating\">Une classe d&#039;\u00e2me n&#039;est pas une aptitude \u00e0 la flexion continue<\/h2>\n<p>La classe 5 ou la classe 6 ne pr\u00e9cise pas, \u00e0 elle seule, la vitesse de d\u00e9placement, le service en torsion, le rayon de courbure admissible ni le nombre de cycles de mouvement d&#039;un c\u00e2ble fini. La construction et les conditions d&#039;application d\u00e9clar\u00e9es doivent \u00eatre \u00e9valu\u00e9es ensemble.<\/p>\n<p>Les exemples de produits ci-dessus montrent pourquoi c&#039;est important : un c\u00e2ble d&#039;enroulement con\u00e7u \u00e0 cet effet peut d\u00e9clarer la classe 5, tandis qu&#039;une construction particuli\u00e8re de retour pour cha\u00eene porte-c\u00e2bles d\u00e9clare la classe 6. Il s&#039;agit de conceptions et de services de c\u00e2ble diff\u00e9rents, et non de la preuve qu&#039;une classe peut remplacer l&#039;autre partout.<\/p>\n<p>Pour un cheminement mobile, v\u00e9rifiez l&#039;assemblage des conducteurs isol\u00e9s, l&#039;isolation, les s\u00e9parateurs, le renfort, l&#039;\u00e9cran et la gaine en plus de l&#039;\u00e2me. Comparez ensuite le cheminement r\u00e9el avec les conditions d\u00e9clar\u00e9es du c\u00e2ble. L&#039;enroulement, le mouvement en <a href=\"https:\/\/tebaoflex-cable.com\/fr\/festoon-system\/\">feston<\/a> , le d\u00e9placement en porte-c\u00e2bles et la torsion sont des exigences diff\u00e9rentes.<\/p>\n<p>Consultez <a href=\"https:\/\/tebaoflex-cable.com\/fr\/cable-minimum-bending-radius\/\">le guide sur le rayon de courbure minimal des c\u00e2bles<\/a> lors de la d\u00e9finition du cheminement. Distinguez les limites en pose fixe et en mouvement, et utilisez le bon diam\u00e8tre du c\u00e2ble fini. Un brin d&#039;\u00e2me plus fin n&#039;autorise pas une courbure plus serr\u00e9e que ne le permet la sp\u00e9cification du c\u00e2ble.<\/p>\n<h2 id=\"match-fine-stranded-conductors-to-their-terminals\">Associez les \u00e2mes \u00e0 brins fins \u00e0 leurs bornes<\/h2>\n<p>Le connecteur ou la borne doit accepter la classe et la section r\u00e9elles de l&#039;\u00e2me. Le fait qu&#039;une \u00e2me entre dans une cosse ou dans l&#039;ouverture d&#039;une borne n&#039;\u00e9tablit pas que la combinaison convient.<\/p>\n<p>Actuellement, <a href=\"https:\/\/www.shopulstandards.com\/ProductDetail.aspx?productId=UL486E\" rel=\"nofollow noopener\" target=\"_blank\">les exigences UL 486E relatives aux bornes de c\u00e2blage d&#039;\u00e9quipements<\/a> reconnaissent des configurations d&#039;\u00e2me sp\u00e9cifi\u00e9es ainsi que des configurations suppl\u00e9mentaires par marquage. Lorsqu&#039;un embout ou un adaptateur est utilis\u00e9, v\u00e9rifiez sa plage de fils \u00e9valu\u00e9e et sa m\u00e9thode d&#039;installation, ainsi que les caract\u00e9ristiques nominales et les instructions de la borne r\u00e9ceptrice.<\/p>\n<p><a href=\"https:\/\/www.shopulstandards.com\/ProductDetail.aspx?UniqueKey=47552\" rel=\"nofollow noopener\" target=\"_blank\">L&#039;UL 486F couvre les embouts nus et isol\u00e9s<\/a>, y compris des applications sp\u00e9cifi\u00e9es d&#039;\u00e2mes \u00e0 brins fins. Cela ne rend pas chaque embout adapt\u00e9 \u00e0 chaque borne. Respectez les exigences de la combinaison choisie en mati\u00e8re de pr\u00e9paration, de longueur de d\u00e9nudage, d&#039;outillage et d&#039;installation.<\/p>\n<p>Pour un c\u00e2ble de soudage, un cordon portable ou un c\u00e2ble de machine de remplacement, indiquez les d\u00e9tails des bornes dans la demande. Ne r\u00e9duisez pas la v\u00e9rification \u00e0 la seule section de l&#039;\u00e2me, et ne supposez pas qu&#039;un changement de pr\u00e9paration de l&#039;extr\u00e9mit\u00e9 r\u00e9sout une classe d&#039;\u00e2me incompatible.<\/p>\n<h2 id=\"write-an-enquiry-that-keeps-size-class-and-duty-together\">R\u00e9digez une demande qui r\u00e9unit section, classe et service<\/h2>\n<p>Une sp\u00e9cification d&#039;\u00e2me utile indique s\u00e9par\u00e9ment la section globale et la classe de c\u00e2blage. \u00ab 4\/0 AWG \u00bb est une d\u00e9signation de section d&#039;\u00e2me ; \u00ab brins constitutifs de 30 AWG \u00bb d\u00e9crit des brins \u00e9l\u00e9mentaires. De m\u00eame, une section en mm\u00b2 n&#039;est pas le diam\u00e8tre ext\u00e9rieur du c\u00e2ble fini. Conservez ces distinctions lorsque vous transposez un plan d&#039;\u00e9quipement en demande d&#039;achat.<\/p>\n<p>Indiquez :<\/p>\n<ol>\n<li><strong>Section de l&#039;\u00e2me et circuit :<\/strong> AWG, kcmil ou mm\u00b2, nombre de conducteurs, conducteurs de protection et \u00e9ventuelles paires de signal.<\/li>\n<li><strong>Norme et classe :<\/strong> la norme d&#039;\u00e2me demand\u00e9e et son \u00e9dition, la classe et toute double sp\u00e9cification requise.<\/li>\n<li><strong>Mat\u00e9riau et construction :<\/strong> cuivre nu ou rev\u00eatu, composition des brins, disposition faisceaux\/torons et toute contrainte de diam\u00e8tre d&#039;\u00e2me.<\/li>\n<li><strong>Exigences du c\u00e2ble complet :<\/strong> isolation, gaine, \u00e9cran, tension nominale et conditions de temp\u00e9rature.<\/li>\n<li><strong>Service m\u00e9canique :<\/strong> usage fixe, manipul\u00e9, tra\u00eenant, en enroulement ou en porte-c\u00e2bles, y compris les donn\u00e9es de cheminement et de mouvement pertinentes.<\/li>\n<li><strong>Raccordements :<\/strong> mod\u00e8le de connecteur ou de borne, classe et section d&#039;\u00e2me accept\u00e9es, et instructions applicables de pr\u00e9paration et d&#039;outillage.<\/li>\n<\/ol>\n<p><a href=\"https:\/\/tebaoflex-cable.com\/fr\/contact-us\/#request-quote\">Envoyez \u00e0 TEBAOFLEX la sp\u00e9cification de l&#039;\u00e2me et le service de l&#039;\u00e9quipement<\/a> pour le <a href=\"https:\/\/tebaoflex-cable.com\/fr\/welding-cable-size-chart-amperage-length-and-duty-cycle\/\">c\u00e2ble de soudage<\/a>, le c\u00e2ble d&#039;alimentation en caoutchouc, le c\u00e2ble d&#039;enroulement ou le circuit en cha\u00eene porte-c\u00e2bles. R\u00e9unir ces exigences donne \u00e0 l&#039;\u00e9quipe une base utile pour v\u00e9rifier la construction, au lieu de choisir \u00e0 partir d&#039;une seule d\u00e9signation de classe.<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Comparez les classes d&#039;\u00e2me et les normes de construction pour les c\u00e2bles de soudage, les c\u00e2bles d&#039;alimentation en caoutchouc, les c\u00e2bles d&#039;enroulement et le c\u00e2blage de retour en cha\u00eene porte-c\u00e2bles. V\u00e9rifiez s\u00e9par\u00e9ment le service du c\u00e2ble et les bornes.<\/p>","protected":false},"author":1,"featured_media":6460,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[621],"tags":[],"class_list":["post-6463","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-cable-selection-engineering-guides"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/tebaoflex-cable.com\/fr\/wp-json\/wp\/v2\/posts\/6463","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/tebaoflex-cable.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/tebaoflex-cable.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/tebaoflex-cable.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/tebaoflex-cable.com\/fr\/wp-json\/wp\/v2\/comments?post=6463"}],"version-history":[{"count":3,"href":"https:\/\/tebaoflex-cable.com\/fr\/wp-json\/wp\/v2\/posts\/6463\/revisions"}],"predecessor-version":[{"id":6761,"href":"https:\/\/tebaoflex-cable.com\/fr\/wp-json\/wp\/v2\/posts\/6463\/revisions\/6761"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/tebaoflex-cable.com\/fr\/wp-json\/wp\/v2\/media\/6460"}],"wp:attachment":[{"href":"https:\/\/tebaoflex-cable.com\/fr\/wp-json\/wp\/v2\/media?parent=6463"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/tebaoflex-cable.com\/fr\/wp-json\/wp\/v2\/categories?post=6463"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/tebaoflex-cable.com\/fr\/wp-json\/wp\/v2\/tags?post=6463"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}