{"id":8724,"date":"2026-11-20T10:01:50","date_gmt":"2026-11-20T02:01:50","guid":{"rendered":"https:\/\/tebaoflex-cable.com\/cases\/fep-f46-vented-capillary-level-transmitter-cable-belarus\/"},"modified":"2026-11-20T10:01:50","modified_gmt":"2026-11-20T02:01:50","slug":"fep-f46-vented-capillary-level-transmitter-cable-belarus","status":"publish","type":"page","link":"https:\/\/tebaoflex-cable.com\/ru\/cases\/fep-f46-vented-capillary-level-transmitter-cable-belarus\/","title":{"rendered":"\u042d\u043a\u0440\u0430\u043d\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u0439 \u0432\u0435\u043d\u0442\u0438\u043b\u0438\u0440\u0443\u0435\u043c\u044b\u0439 \u043a\u0430\u043f\u0438\u043b\u043b\u044f\u0440\u043d\u044b\u0439 \u043a\u0430\u0431\u0435\u043b\u044c F46 (FEP) 4\u00d70.2 mm\u00b2 \u0434\u043b\u044f \u043f\u043e\u0433\u0440\u0443\u0436\u043d\u044b\u0445 \u0433\u0438\u0434\u0440\u043e\u0441\u0442\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0434\u0430\u0442\u0447\u0438\u043a\u043e\u0432 \u0443\u0440\u043e\u0432\u043d\u044f \u0432 \u0411\u0435\u043b\u0430\u0440\u0443\u0441\u0438"},"content":{"rendered":"\n<style>\n.tbf-case-pg{max-width:960px;margin-left:auto;margin-right:auto;--ink:#16202b;--muted:#5b6b7c;--line:#e2e8ee;--accent:#b4381f;--soft:#f6f8fa;color:var(--ink);line-height:1.7;font-size:17px}\n.tbf-case-pg h1{font-size:2rem;line-height:1.2;margin:0 0 .6rem}\n.tbf-case-pg h2{font-size:1.5rem;margin:2.4rem 0 .5rem;border-top:3px solid var(--ink);padding-top:.5rem}\n.tbf-case-pg h3{font-size:1.08rem;margin:1.4rem 0 .3rem}\n.tbf-case-pg p{margin:0 0 1rem}\n.tbf-case-pg a{color:var(--accent);text-underline-offset:2px}\n.tbf-kicker{font-size:.75rem;letter-spacing:.1em;text-transform:uppercase;font-weight:700;color:#1f7a5c;margin-bottom:.4rem}\n.tbf-lede{font-size:1.1rem;color:var(--muted)}\n.tbf-case-pg table{width:100%;border-collapse:collapse;margin:1.1rem 0;font-size:.96rem}\n.tbf-case-pg th,.tbf-case-pg td{border:1px solid var(--line);padding:.55rem .75rem;text-align:left;vertical-align:top}\n.tbf-case-pg th{background:var(--soft);width:34%;font-weight:700}\n.tbf-wide{min-width:620px}\n.tbf-wide th{width:auto}\n.tbf-tw{overflow-x:auto}\n.tbf-hero{margin:1.3rem 0 .3rem}\n.tbf-hero img{width:100%;height:auto;display:block;border-radius:10px;border:1px solid var(--line);background:#fff}\n.tbf-hero figcaption,.tbf-fig figcaption{font-size:.85rem;color:var(--muted);margin-top:.4rem}\n.tbf-fig{margin:1.4rem 0}\n.tbf-fig img{width:100%;max-width:520px;height:auto;display:block;margin:0 auto;border-radius:10px;border:1px solid var(--line);background:#fff}\n.tbf-shots{display:grid;grid-template-columns:1fr 1fr;gap:1rem;margin:1.4rem 0}\n.tbf-shots figure{margin:0}\n.tbf-shots img{width:100%;height:360px;object-fit:contain;background:#fff;border-radius:10px;border:1px solid var(--line);display:block}\n.tbf-shots figcaption{font-size:.85rem;color:var(--muted);margin-top:.4rem}\n.tbf-scope{border:1px dashed var(--line);border-radius:8px;padding:.85rem 1.1rem;margin:1.2rem 0;font-size:.92rem;color:var(--muted);background:var(--soft)}\n.tbf-eng{background:var(--soft);border-left:3px solid var(--ink);padding:.2rem 1.1rem .6rem;margin:1.2rem 0;border-radius:0 8px 8px 0}\n.tbf-eng .tag{display:inline-block;font-size:.7rem;letter-spacing:.09em;text-transform:uppercase;font-weight:700;color:var(--muted);margin:.9rem 0 .2rem}\n.tbf-need{background:#fdf6f4;border-left:3px solid var(--accent);padding:.9rem 1.1rem;margin:1.2rem 0;border-radius:0 8px 8px 0}\n.tbf-need ul{margin:.4rem 0 0;padding-left:1.1rem;columns:2;column-gap:2rem}\n.tbf-need li{margin:.2rem 0;break-inside:avoid}\n.tbf-rel ul{padding-left:1.1rem;columns:2;column-gap:2rem}\n.tbf-rel li{margin:.22rem 0;break-inside:avoid}\n.tbf-faq details{border-bottom:1px solid var(--line);padding:.8rem 0}\n.tbf-faq summary{cursor:pointer;font-weight:600}\n.tbf-faq p{margin:.55rem 0 0;color:var(--muted)}\n.tbf-cta{display:inline-block;background:var(--accent);color:#fff!important;text-decoration:none!important;border-radius:8px;padding:.6rem 1.15rem;font-weight:600;margin-top:.5rem}\n.tbf-byline{font-size:.92rem;color:var(--muted);background:var(--soft);border-radius:8px;padding:.85rem 1.1rem;margin:1.6rem 0}\n.tbf-back{font-size:.9rem;margin-top:2rem;padding-top:1rem;border-top:1px solid var(--line)}\n@media(max-width:640px){.tbf-shots{grid-template-columns:1fr}.tbf-need ul,.tbf-rel ul{columns:1}.tbf-case-pg th{width:auto}}\n.tbf-case-pg caption{caption-side:top;text-align:left;font-weight:700;font-size:.95rem;color:var(--ink);margin-bottom:.45rem}.tbf-case-pg ul.tbf-list,.tbf-case-pg ol.tbf-list{padding-left:1.2rem;margin:0 0 1rem}.tbf-case-pg .tbf-list li{margin:.3rem 0}.tbf-case-pg .tbf-answer{font-size:1.04rem;border-left:3px solid #1f7a5c;padding:.1rem 0 .1rem .9rem}.tbf-sys{width:100%;max-width:760px;height:auto;display:block;margin:0 auto}.tbf-diag{margin:1.4rem 0}.tbf-diag figcaption{font-size:.85rem;color:var(--muted);margin-top:.4rem}.tbf-print{font-family:ui-monospace,Consolas,monospace;font-size:.92rem;background:#f4f6f8;padding:.5rem .7rem;border-radius:4px;overflow-wrap:anywhere}@media(max-width:640px){.tbf-shots{grid-template-columns:1fr}.tbf-shots img{height:auto}}\n<\/style>\n<div class=\"tbf-case-pg\">\n<p class=\"tbf-kicker\">Case 25 \u00b7 Belarus \u00b7 Hydrostatic Level Transmitters \u00b7 F46 (FEP) Vented Capillary Cable<\/p>\n<h1>F46 (FEP) 4\u00d70.2 mm\u00b2 Vented Capillary Shielded Cable for Submersible Level Transmitters in Belarus<\/h1>\n<p class=\"tbf-lede\">A pressure-transmitter manufacturer in Belarus\u2014producing submersible hydrostatic level gauges for aggressive industrial tanks\u2014needed a long-term cable source starting with a 1,000 m trial qualification batch ahead of recurring multi-kilometer volume. The specification combined conflicting material constraints inside a tight 6.9 to 7.3 mm transmitter gland window: four 0.2 mm\u00b2 tinned-copper signal cores with PE insulation, high-tensile polyamide yarns, a central hollow atmospheric-pressure compensation capillary tube, a tinned-copper braided EMC shield and a chemical-resistant black F46 (FEP) fluoropolymer outer sheath. TEBAOFLEX re-balanced the four signal cores into a 90-degree symmetrical layout, solved the high-temperature FEP-over-PE extrusion thermal barrier without collapsing the 1.60 mm vent bore, and verified finished cable dimensions at 6.99 to 7.11 mm OD with a 0.59 to 0.70 mm FEP jacket wall.<\/p>\n<figure class=\"tbf-hero\"><img fetchpriority=\"high\" src=\"https:\/\/tebaoflex-cable.com\/wp-content\/uploads\/2026\/11\/fep-f46-vented-capillary-level-transmitter-cable-belarus-hero.webp\" alt=\"Stripped factory sample of TEBAOFLEX 4\u00d70.2 mm\u00b2 F46 (FEP) vented capillary hydrostatic level-transmitter cable showing black FEP outer jacket, tinned-copper EMC braid, polyamide tensile yarns, four PE-insulated cores and central hollow vent tube\" width=\"1200\" height=\"900\" fetchpriority=\"high\" decoding=\"async\" data-no-lazy=\"1\"><figcaption>Finished production sample for the Belarus 1,000 m qualification order: matte-black F46 (FEP) acid\/alkali-resistant outer sheath, woven tinned-copper (CuSn) EMC braid, polyamide tensile strength fibers, symmetrically spaced yellow\/green\/blue\/red 0.2 mm\u00b2 PE cores and the central hollow capillary tube.<\/figcaption><\/figure>\n<h2 id=\"project-at-a-glance\">Project at a glance<\/h2>\n<p class=\"tbf-answer\">This 1,000 m trial qualification order for a Belarus pressure-transmitter manufacturer delivered a custom 4 \u00d7 0.2 mm\u00b2 shielded vented capillary cable with a central 1.60 mm OD hollow PE vent tube, polyamide tensile fibers, a CuSn braid and a black F46 (FEP) outer sheath verified at 6.99 to 7.11 mm OD.<\/p>\n<div class=\"tbf-tw\"><table><caption>Summary of the Belarus F46 (FEP) 4\u00d70.2 mm\u00b2 vented capillary level-transmitter cable qualification order<\/caption><thead><tr><th scope=\"col\">Order item<\/th><th scope=\"col\">Verified engineering detail<\/th><\/tr><\/thead><tbody>\n<tr><th scope=\"row\">Destination &#038; application<\/th><td>Belarus \u2014 submersible hydrostatic level transmitters (pressure gauges) operating in corrosive acid, alkali and chemical-vapor tanks<\/td><\/tr>\n<tr><th scope=\"row\">Order qualification scope<\/th><td>1,000 m continuous sequential metre-marked qualification batch (ahead of recurring 10 km program evaluation)<\/td><\/tr>\n<tr><th scope=\"row\">Signal conductors<\/th><td>4 \u00d7 0.2 mm\u00b2 finely stranded tinned copper (CuSn) with colour-coded polyethylene (PE) insulation (yellow, green, blue, red)<\/td><\/tr>\n<tr><th scope=\"row\">Atmospheric vent capillary tube<\/th><td>Central hollow PE polymer capillary tube (1.60 mm caliper-verified OD) \u2014 flexible, collapse-resistant and vapor-resistant<\/td><\/tr>\n<tr><th scope=\"row\">Tensile reinforcement &#038; DFM layout<\/th><td>Four symmetrical polyamide tensile yarn sectors alternating at 90-degree intervals with the four signal cores around the central tube<\/td><\/tr>\n<tr><th scope=\"row\">EMC screen &#038; chemical outer sheath<\/th><td>Protective barrier wrapping + woven tinned-copper (CuSn) wire braid + black F46 (FEP) fluorinated ethylene propylene outer sheath<\/td><\/tr>\n<tr><th scope=\"row\">Verified caliper measurements<\/th><td>Finished OD: 6.99 mm \/ 7.11 mm (target 6.9\u20137.3 mm) \u00b7 FEP outer wall: 0.59\u20130.70 mm (0.68 mm typical) \u00b7 Central vent tube OD: 1.60 mm<\/td><\/tr>\n<tr><th scope=\"row\">Thermal rating, mass &#038; print<\/th><td>\u221240 \u00b0C to +70 \u00b0C operating range \u00b7 approx. 0.077 kg\/m nominal weight \u00b7 TEBAOFLEX 4\u00d70.2+Capillary Tube Combined Shielded Cable 0001M&#8230;1000M<\/td><\/tr>\n<\/tbody><\/table><\/div>\n<div class=\"tbf-scope\"><strong>Scope note.<\/strong> This engineering case documents the DFM core-symmetry redesign, high-temperature F46 (FEP)-over-PE extrusion process control and factory digital-caliper inspection for the Belarus vented capillary cable order. Customer company identity, personnel names and commercial settlement terms remain confidential.<\/div>\n<h2 id=\"fep-over-pe-thermal-barrier\">Why is extruding F46 (FEP) over PE cores and a hollow vent tube a critical factory hurdle?<\/h2>\n<p class=\"tbf-answer\">Fluorinated ethylene propylene (F46 \/ FEP) requires extrusion melt temperatures above 330 \u00b0C, whereas polyethylene (PE) core insulation and hollow PE atmospheric vent tubes soften above 105 \u00b0C to 130 \u00b0C. Controlled barrier wrapping, rapid crosshead drawdown and immediate water-trough quenching kept the 1.60 mm bore open and round.<\/p>\n<p>Submersible hydrostatic level transmitters installed in acid pickling tanks, caustic neutralization basins and industrial chemical sumps demand two seemingly opposite polymer properties in one slim 7 mm cable. On the outside, the jacket must resist concentrated acids, alkalis and corrosive process vapors without swelling, hardening or leaching plasticizers\u2014a chemical envelope far beyond PVC or standard oil-rated jackets (compared in our <a href=\"https:\/\/tebaoflex-cable.com\/oil-resistant-cable-ratings\/\">industrial oil- and fluid-resistant cable ratings guide<\/a>). That drives transmitter OEMs to specify fluorinated ethylene propylene (F46 \/ FEP), the same fluoropolymer family used in our <a href=\"https:\/\/tebaoflex-cable.com\/product\/fep-6y-fep-c-6y-multicore-control-cable\/\">FEP-6Y \/ FEP-C-6Y screened fluoropolymer control cables<\/a>, <a href=\"https:\/\/tebaoflex-cable.com\/product\/screened-fep-pfa-pt100-rtd-sensor-cable\/\">screened FEP\/PFA industrial sensor cables<\/a> and <a href=\"https:\/\/tebaoflex-cable.com\/product\/kff-kffp-kffrp-djfpfp-fluoroplastic-control-cable\/\">KFFP fluoroplastic instrumentation series<\/a>.<\/p><p>Inside the cable, however, this Belarus transmitter schedule retained low-capacitance polyethylene (PE) core insulation and a flexible hollow PE atmospheric capillary tube across a \u221240 \u00b0C to +70 \u00b0C operating envelope. As detailed in our <a href=\"https:\/\/tebaoflex-cable.com\/high-temp-wire-insulation-ratings\/\">high-temperature wire insulation ratings guide<\/a>, FEP melts above 260 \u00b0C and extrudes around 330 \u00b0C to 380 \u00b0C\u2014nearly triple PE&#8217;s softening temperature. During pre-production engineering review at our Taicang facility, process engineers resolved this melt-temperature mismatch through three controls:<\/p><ul class=\"tbf-list\"><li><strong>Thermal-barrier wrapping + metallic CuSn braid heat sink:<\/strong> Wrapping the core-and-polyamide assembly beneath a dense <a href=\"https:\/\/tebaoflex-cable.com\/tinned-copper-vs-bare-copper\/\">tinned-copper (CuSn)<\/a> wire braid (<a href=\"https:\/\/webstore.iec.ch\/en\/publication\/71891\" rel=\"nofollow noopener\" target=\"_blank\">IEC 60228<\/a> fine-stranded basis) shields the inner PE components from direct molten-FEP contact while providing full-circumference EMC screening for millivolt or 4\u201320 mA sensor signals (see our <a href=\"https:\/\/tebaoflex-cable.com\/pas-5308-instrumentation-cable-specification-guide\/\">shielded instrumentation cable specification guide<\/a>).<\/li><li><strong>Tube-extrusion drawdown control:<\/strong> Applying the black F46 (FEP) jacket via calibrated tubing drawdown rather than high-pressure compression extrusion avoids squeezing the 1.60 mm hollow capillary lumen flat while the tube is warm.<\/li><li><strong>Immediate post-die cooling:<\/strong> Fast-quench trough cooling right downstream of the fluoropolymer crosshead freezes the 0.59 to 0.70 mm FEP outer wall before conductive heat can penetrate to the central vent channel.<\/li><\/ul>\n<div class=\"tbf-shots\">\n<figure><img loading=\"lazy\" src=\"https:\/\/tebaoflex-cable.com\/wp-content\/uploads\/2026\/11\/fep-vented-level-cable-open-capillary-lumen-symmetrical-cores.webp\" alt=\"Macro end view of the finished 4\u00d70.2 mm\u00b2 vented capillary cable showing the open circular air bore in the central PE vent tube surrounded by yellow, green, blue and red PE-insulated CuSn cores and polyamide tensile fibers\" width=\"1200\" height=\"900\" loading=\"lazy\" decoding=\"async\"><figcaption>Macro end-on check after F46 (FEP) extrusion: the translucent central capillary tube lumen remains cleanly open and circular alongside the four intact PE-insulated CuSn cores and polyamide tensile yarns.<\/figcaption><\/figure>\n<figure><img loading=\"lazy\" src=\"https:\/\/tebaoflex-cable.com\/wp-content\/uploads\/2026\/11\/fep-f46-vented-capillary-cable-cusn-braid-strip-inspection.webp\" alt=\"Step-stripped inspection sample of TEBAOFLEX 4\u00d70.2 mm\u00b2 vented capillary cable displaying the smooth black F46 (FEP) outer sheath, tinned-copper wire braid screen and symmetrically laid signal cores\" width=\"1200\" height=\"900\" loading=\"lazy\" decoding=\"async\"><figcaption>Step-stripped sample confirming clean separation between the black F46 (FEP) chemical outer sheath, woven tinned-copper EMC braid and internal core bundle for transmitter potting and termination.<\/figcaption><\/figure>\n<\/div>\n<h2 id=\"symmetrical-core-dfm-redesign\">DFM improvement: re-balancing four 0.2 mm\u00b2 cores and polyamide tensile yarns around the vent tube<\/h2>\n<p class=\"tbf-answer\">In the buyer&#8217;s initial schematic, the yellow and red 0.2 mm\u00b2 cores sat directly adjacent on one side of the central capillary tube. TEBAOFLEX engineers proposed spacing all four cores symmetrically at 90-degree intervals separated by polyamide tensile yarns so hanging load and gland torque compress the vent tube evenly.<\/p>\n<figure class=\"tbf-diag\"><svg class=\"tbf-sys\" viewBox=\"0 0 760 318\" role=\"img\" aria-labelledby=\"tbf-c25-title tbf-c25-desc\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><title id=\"tbf-c25-title\">DFM core symmetry comparison for 4\u00d70.2 mm\u00b2 F46 (FEP) vented capillary level-transmitter cable<\/title><desc id=\"tbf-c25-desc\">Left panel shows the initial asymmetric drawing where red and yellow PE cores sit directly adjacent on one side of the central hollow vent tube. Right panel shows the TEBAOFLEX production redesign placing yellow, green, blue and red 0.2 mm\u00b2 CuSn cores symmetrically at 90-degree intervals separated by polyamide tensile yarns around the 1.60 mm central PE capillary tube, enclosed by protective wrapping, a tinned-copper wire braid and a 0.59 to 0.70 mm black F46 (FEP) outer sheath measuring 6.99 to 7.11 mm OD.<\/desc><rect x=\"0\" y=\"0\" width=\"760\" height=\"318\" fill=\"#fbfcfd\"\/><rect x=\"14\" y=\"14\" width=\"356\" height=\"290\" rx=\"6\" fill=\"#ffffff\" stroke=\"#d5dce4\" stroke-width=\"1.2\"\/><rect x=\"390\" y=\"14\" width=\"356\" height=\"290\" rx=\"6\" fill=\"#ffffff\" stroke=\"#1f7a5c\" stroke-width=\"1.5\"\/><text x=\"192\" y=\"38\" text-anchor=\"middle\" font-family=\"system-ui,Segoe UI,Arial,sans-serif\" font-size=\"13.5\" font-weight=\"700\" fill=\"#8b1e1e\">1. Initial Asymmetric Core Layout<\/text><text x=\"568\" y=\"38\" text-anchor=\"middle\" font-family=\"system-ui,Segoe UI,Arial,sans-serif\" font-size=\"13.5\" font-weight=\"700\" fill=\"#1f7a5c\">2. TEBAOFLEX 90\u00b0 Symmetrical DFM Build<\/text><circle cx=\"192\" cy=\"144\" r=\"82\" fill=\"#1d2228\" stroke=\"#0c0f12\" stroke-width=\"1.6\"\/><circle cx=\"192\" cy=\"144\" r=\"68\" fill=\"none\" stroke=\"#cfd6de\" stroke-width=\"5\" stroke-dasharray=\"5,2.5\"\/><circle cx=\"192\" cy=\"144\" r=\"63\" fill=\"#f3f5f8\" stroke=\"#9aa5b1\" stroke-width=\"1\"\/><circle cx=\"192\" cy=\"144\" r=\"24\" fill=\"#c7ced6\" stroke=\"#7b8794\" stroke-width=\"1.4\"\/><circle cx=\"192\" cy=\"144\" r=\"14\" fill=\"#ffffff\" stroke=\"#7b8794\" stroke-width=\"1\"\/><circle cx=\"192\" cy=\"102\" r=\"16\" fill=\"#d3d9e0\" stroke=\"#9aa5b1\" stroke-width=\"1\"\/><circle cx=\"228\" cy=\"123\" r=\"16\" fill=\"#238a3b\"\/><circle cx=\"228\" cy=\"123\" r=\"8\" fill=\"#dfe4ea\"\/><circle cx=\"228\" cy=\"165\" r=\"16\" fill=\"#d3d9e0\" stroke=\"#9aa5b1\" stroke-width=\"1\"\/><circle cx=\"192\" cy=\"186\" r=\"16\" fill=\"#1c64c7\"\/><circle cx=\"192\" cy=\"186\" r=\"8\" fill=\"#dfe4ea\"\/><circle cx=\"156\" cy=\"165\" r=\"16\" fill=\"#e5b819\"\/><circle cx=\"156\" cy=\"165\" r=\"8\" fill=\"#dfe4ea\"\/><circle cx=\"156\" cy=\"123\" r=\"16\" fill=\"#c92e2e\"\/><circle cx=\"156\" cy=\"123\" r=\"8\" fill=\"#dfe4ea\"\/><path d=\"M135 121 Q 124 144 135 167\" fill=\"none\" stroke=\"#8b1e1e\" stroke-width=\"2\" stroke-dasharray=\"3,2\"\/><text x=\"192\" y=\"250\" text-anchor=\"middle\" font-family=\"system-ui,Segoe UI,Arial,sans-serif\" font-size=\"11.5\" font-weight=\"600\" fill=\"#8b1e1e\">Red &amp; yellow cores paired on one side<\/text><text x=\"192\" y=\"270\" text-anchor=\"middle\" font-family=\"system-ui,Segoe UI,Arial,sans-serif\" font-size=\"11\" fill=\"#4a5a6a\">Uneven radial stiffness during reeling &amp; gland<\/text><text x=\"192\" y=\"287\" text-anchor=\"middle\" font-family=\"system-ui,Segoe UI,Arial,sans-serif\" font-size=\"11\" fill=\"#4a5a6a\">compression risks ovalizing the vent bore<\/text><circle cx=\"568\" cy=\"144\" r=\"82\" fill=\"#1d2228\" stroke=\"#0c0f12\" stroke-width=\"1.6\"\/><circle cx=\"568\" cy=\"144\" r=\"68\" fill=\"none\" stroke=\"#cfd6de\" stroke-width=\"5\" stroke-dasharray=\"5,2.5\"\/><circle cx=\"568\" cy=\"144\" r=\"63\" fill=\"#f3f5f8\" stroke=\"#9aa5b1\" stroke-width=\"1\"\/><circle cx=\"568\" cy=\"144\" r=\"24\" fill=\"#c7ced6\" stroke=\"#1f7a5c\" stroke-width=\"1.6\"\/><circle cx=\"568\" cy=\"144\" r=\"14\" fill=\"#ffffff\" stroke=\"#1f7a5c\" stroke-width=\"1.2\"\/><circle cx=\"568\" cy=\"102\" r=\"16\" fill=\"#e5b819\"\/><circle cx=\"568\" cy=\"102\" r=\"8\" fill=\"#dfe4ea\"\/><circle cx=\"610\" cy=\"144\" r=\"16\" fill=\"#238a3b\"\/><circle cx=\"610\" cy=\"144\" r=\"8\" fill=\"#dfe4ea\"\/><circle cx=\"568\" cy=\"186\" r=\"16\" fill=\"#1c64c7\"\/><circle cx=\"568\" cy=\"186\" r=\"8\" fill=\"#dfe4ea\"\/><circle cx=\"526\" cy=\"144\" r=\"16\" fill=\"#c92e2e\"\/><circle cx=\"526\" cy=\"144\" r=\"8\" fill=\"#dfe4ea\"\/><circle cx=\"598\" cy=\"114\" r=\"14\" fill=\"#f2e6b6\" stroke=\"#b59f5b\" stroke-width=\"1\"\/><circle cx=\"598\" cy=\"174\" r=\"14\" fill=\"#f2e6b6\" stroke=\"#b59f5b\" stroke-width=\"1\"\/><circle cx=\"538\" cy=\"174\" r=\"14\" fill=\"#f2e6b6\" stroke=\"#b59f5b\" stroke-width=\"1\"\/><circle cx=\"538\" cy=\"114\" r=\"14\" fill=\"#f2e6b6\" stroke=\"#b59f5b\" stroke-width=\"1\"\/><text x=\"568\" y=\"250\" text-anchor=\"middle\" font-family=\"system-ui,Segoe UI,Arial,sans-serif\" font-size=\"11.5\" font-weight=\"600\" fill=\"#1f7a5c\">90\u00b0 balanced cores + 4 tensile yarn sectors<\/text><text x=\"568\" y=\"270\" text-anchor=\"middle\" font-family=\"system-ui,Segoe UI,Arial,sans-serif\" font-size=\"11\" fill=\"#4a5a6a\">Caliper verified: 6.99\u20137.11 mm OD \u00b7 0.59\u20130.70 mm FEP<\/text><text x=\"568\" y=\"287\" text-anchor=\"middle\" font-family=\"system-ui,Segoe UI,Arial,sans-serif\" font-size=\"11\" fill=\"#4a5a6a\">1.60 mm central PE capillary bore stays open &amp; round<\/text><\/svg><figcaption>Pre-production DFM review: shifting from an asymmetric core grouping (left) to four 90-degree symmetrical 0.2 mm\u00b2 cores separated by balanced polyamide tensile yarn sectors (right) prevents vent-bore ovalization inside tight transmitter cable glands.<\/figcaption><\/figure>\n<p>Submersible hydrostatic probes hang freely from their own cable down deep chemical wells and bore pipes, often 10 m to 100 m below the top junction box. If copper signal conductors carry the suspended weight of the stainless-steel or titanium sensor body, fine 0.2 mm\u00b2 strands work-harden and open-circuit; meanwhile, if radial compression inside the stainless-steel sensor cable gland pushes harder from one side than the other, the thin polymer capillary bore can kink and block barometric equalization.<\/p><p>By alternating the four colour-coded PE cores (yellow, green, blue, red) at 90-degree symmetry with four equal sectors of polyamide tensile cord around the central capillary tube, tensile pull transfers cleanly to the high-modulus strength yarns while every quadrant presents identical crush resistance under the sensor compression gland. How cable outside diameter and jacket modulus interact with submerged sealing glands is examined further in our <a href=\"https:\/\/tebaoflex-cable.com\/pur-vs-ldpe-rov-tether-potting-penetrator-guide\/\">submerged cable jacket and compression penetrator sizing guide<\/a>, and related underwater multi-element builds are shown on our <a href=\"https:\/\/tebaoflex-cable.com\/product\/seabed-observation-aquaculture-subsea-composite-cable\/\">submerged sensor and observation composite cable page<\/a>.<\/p>\n<h2 id=\"caliper-verification-and-marking\">Digital caliper QC: holding 6.99\u20137.11 mm OD inside the 6.9\u20137.3 mm transmitter gland window<\/h2>\n<p class=\"tbf-answer\">Transmitter cable glands tolerate only \u00b10.2 mm diameter deviation before losing IP68 immersion seal or failing to assemble. Digital caliper inspection on the finished Belarus batch verified 6.99 mm and 7.11 mm outside diameters, 0.59 to 0.70 mm F46 (FEP) outer-wall thickness and an un-deformed 1.60 mm central capillary tube.<\/p>\n<div class=\"tbf-tw\"><table class=\"tbf-wide\"><caption>Pre-shipment digital caliper inspection and construction verification for the Belarus F46 (FEP) vented capillary cable<\/caption><thead><tr><th scope=\"col\">Inspected dimension \/ item<\/th><th scope=\"col\">Belarus OEM specification<\/th><th scope=\"col\">Factory digital-caliper result<\/th><th scope=\"col\">Engineering acceptance note<\/th><\/tr><\/thead><tbody>\n<tr><th scope=\"row\">Finished cable outside \u00d8<\/th><td>6.9 \u2013 7.3 mm<\/td><td>6.99 mm \/ 7.11 mm (two axes)<\/td><td>Centered cleanly inside \u00b10.2 mm sensor compression-gland seal window<\/td><\/tr>\n<tr><th scope=\"row\">F46 (FEP) outer sheath wall<\/th><td>Chemical barrier black FEP<\/td><td>0.59 mm \/ 0.68 mm \/ 0.70 mm<\/td><td>Concentric fluoropolymer barrier against acids, alkalis and vapors<\/td><\/tr>\n<tr><th scope=\"row\">Central capillary vent tube OD<\/th><td>Flexible hollow PE vent bore<\/td><td>1.60 mm OD (open lumen)<\/td><td>Verified circular and un-collapsed after high-temperature FEP extrusion<\/td><\/tr>\n<tr><th scope=\"row\">Signal cores &#038; EMC screen<\/th><td>4 \u00d7 0.2 mm\u00b2 CuSn + CuSn braid<\/td><td>Yellow, green, blue, red (90\u00b0)<\/td><td>Symmetrical 4-quadrant lay with polyamide tensile strength fibers<\/td><\/tr>\n<tr><th scope=\"row\">Thermal &#038; nominal mass basis<\/th><td>\u221240 \u00b0C to +70 \u00b0C \u00b7 ~0.077 kg\/m<\/td><td>1,000 m qualification batch<\/td><td>Sequential metre printing from 0001M to 1000M for reel-off tracking<\/td><\/tr>\n<\/tbody><\/table><\/div>\n<p class=\"tbf-print\">TEBAOFLEX 4\u00d70.2+Capillary Tube Combined Shielded Cable 0001M 0002M&#8230;1000M<\/p>\n<div class=\"tbf-shots\">\n<figure><img loading=\"lazy\" src=\"https:\/\/tebaoflex-cable.com\/wp-content\/uploads\/2026\/11\/fep-vented-level-cable-caliper-od-6-99mm-gland-check.webp\" alt=\"Factory digital caliper measuring 6.99 mm finished outside diameter on the F46 (FEP) vented capillary level-transmitter cable, inside the 6.9 to 7.3 mm pressure-transmitter cable-gland window\" width=\"1200\" height=\"900\" loading=\"lazy\" decoding=\"async\"><figcaption>Digital caliper verifying 6.99 mm finished outside diameter on the completed F46 (FEP) vented capillary cable (target window 6.9 to 7.3 mm).<\/figcaption><\/figure>\n<figure><img loading=\"lazy\" src=\"https:\/\/tebaoflex-cable.com\/wp-content\/uploads\/2026\/11\/fep-vented-level-cable-caliper-od-7-11mm-gland-check.webp\" alt=\"Second orthogonal digital caliper check recording 7.11 mm finished outside diameter on the 4\u00d70.2 mm\u00b2 F46 (FEP) vented level-sensor cable, confirming circularity within the 6.9 to 7.3 mm specification\" width=\"1200\" height=\"900\" loading=\"lazy\" decoding=\"async\"><figcaption>Orthogonal diameter check recording 7.11 mm across the black F46 (FEP) outer jacket, confirming uniform roundness for watertight sensor glands.<\/figcaption><\/figure>\n<\/div>\n<div class=\"tbf-shots\">\n<figure><img loading=\"lazy\" src=\"https:\/\/tebaoflex-cable.com\/wp-content\/uploads\/2026\/11\/fep-f46-outer-sheath-wall-thickness-0-68mm-caliper.webp\" alt=\"Digital caliper verifying 0.68 mm wall thickness on a peeled strip of the black F46 (FEP) chemical-resistant outer sheath (0.59 to 0.70 mm across batch inspection points)\" width=\"1200\" height=\"900\" loading=\"lazy\" decoding=\"async\"><figcaption>Peeled black F46 (FEP) outer jacket strip measured at 0.68 mm wall thickness (0.59 to 0.70 mm recorded across batch inspection points).<\/figcaption><\/figure>\n<figure><img loading=\"lazy\" src=\"https:\/\/tebaoflex-cable.com\/wp-content\/uploads\/2026\/11\/vented-level-cable-central-pe-capillary-tube-1-60mm-caliper.webp\" alt=\"Digital caliper recording 1.60 mm outside diameter on the central translucent PE atmospheric-pressure compensation capillary tube after high-temperature F46 (FEP) outer-sheath extrusion\" width=\"1200\" height=\"900\" loading=\"lazy\" decoding=\"async\"><figcaption>Digital caliper verifying 1.60 mm outside diameter on the translucent central PE capillary vent tube with open air lumen intact post-extrusion.<\/figcaption><\/figure>\n<\/div>\n<h2 id=\"rfq-checklist\">What to specify when ordering vented capillary hydrostatic level-sensor cables<\/h2>\n<p class=\"tbf-answer\">To match your transmitter body gland and tank chemistry without prototype rework, specify fluid\/vapor exposure (PE vs PUR vs F46\/FEP jacket), exact finished OD tolerance, conductor count\/mm\u00b2, capillary tube bore\/OD and maximum hanging depth.<\/p>\n<div class=\"tbf-need\"><strong>Send these transmitter-cable parameters for a pre-production DFM drawing review:<\/strong>\n<ul>\n<li>Chemical &#038; immersion exposure: clean water\/boreholes (PE or polyether PUR jacket) vs acids, alkalis, hydrocarbons or corrosive vapors (F46\/FEP or PVDF outer jacket)<\/li>\n<li>Transmitter cable-gland sealing OD window (for example 6.9 to 7.3 mm or 7.5 \u00b10.2 mm) and whether potting adhesion primer\/etching is required on fluoropolymer sheaths<\/li>\n<li>Conductor count, cross-section and plating: e.g. 2, 4 or 6 \u00d7 0.2 mm\u00b2 \/ 0.25 mm\u00b2 \/ 0.34 mm\u00b2 tinned copper (CuSn) plus overall CuSn braid or foil+drain EMC screen<\/li>\n<li>Capillary vent tube material and dimensions: PE, PP, FEP or PVDF vent tube ID\/OD (e.g. 1.60 mm OD) and collapse-pressure depth requirement<\/li>\n<li>Suspended cable length &#038; tensile member: polyamide or aramid strength yarns for deep wells, plus trial batch vs production drum length (from 50 m MOQ)<\/li>\n<\/ul>\n<p>As of November 2026, TEBAOFLEX manufactures custom vented capillary, fluoropolymer sensor and instrumentation cables at our Taicang factory from a 50 m minimum order quantity (MOQ), with standard production lead times of 7 to 45 working days depending on fluoropolymer extrusion tooling and batch length. Review fluoropolymer material options on our <a href=\"https:\/\/tebaoflex-cable.com\/solutions\/high-temperature-wire-manufacturer\/\">high-temperature and fluoropolymer wire solutions page<\/a> or browse our <a href=\"https:\/\/tebaoflex-cable.com\/products\/high-temperature-cables\/\">fluoropolymer and high-temperature cables catalogue<\/a>.<\/p><\/div>\n<p><a class=\"tbf-cta\" href=\"https:\/\/tebaoflex-cable.com\/contact-us\/#request-quote\">Request a vented capillary sensor cable DFM drawing &amp; quote &rarr;<\/a><\/p>\n<h2 id=\"faq\">Frequently asked questions on F46 (FEP) vented capillary level-transmitter cables<\/h2>\n<div class=\"tbf-faq\">\n<details><summary>Why does a submersible hydrostatic level transmitter require a built-in capillary vent tube inside its cable?<\/summary><p>Gauge-referenced submersible hydrostatic level sensors measure liquid depth by comparing total pressure at the submerged diaphragm against local atmospheric air pressure. Running an integrated hollow capillary vent tube inside the cable equalizes atmospheric pressure directly behind the sensing diaphragm so barometric weather swings do not introduce false level drift.<\/p><\/details>\n<details><summary>Why is an F46 (FEP) outer sheath chosen over PVC or standard polyurethane for corrosive level-sensor service?<\/summary><p>In chemical dosing tanks, acid\/alkali sumps, leachate wells and industrial effluent basins, chemical vapors and aggressive liquids swell PVC and hydrolyze standard polyurethane jackets. Fluorinated ethylene propylene (F46 \/ FEP) provides broad chemical inertness against concentrated acids, alkalis and process vapors across \u221240 \u00b0C to +70 \u00b0C while keeping a smooth, non-stick surface that resists biological fouling.<\/p><\/details>\n<details><summary>What makes extruding an F46 (FEP) jacket over PE-insulated cores and a PE capillary tube technically difficult?<\/summary><p>F46 (FEP) melts near 260 \u00b0C to 280 \u00b0C and is extruded above 330 \u00b0C, whereas polyethylene (PE) core insulation and a hollow PE capillary vent tube soften above 105 \u00b0C to 130 \u00b0C. Without thermal-barrier wrapping, calibrated crosshead drawdown and rapid cooling right after the die, melt heat can deform the PE cores or collapse the 1.60 mm hollow capillary lumen.<\/p><\/details>\n<details><summary>Why did TEBAOFLEX adjust the Belarus buyer&#x27;s core layout from adjacent yellow\/red cores to a 90-degree symmetrical layout?<\/summary><p>Placing two copper cores side by side on one side of a hollow capillary tube creates an asymmetric cross-section that flexes unevenly and concentrates radial compression onto one wall of the vent bore when tightened inside a transmitter cable gland. Spacing the four 0.2 mm\u00b2 cores symmetrically at 90-degree intervals separated by four equal polyamide tensile yarn sectors balances both hanging tension and gland compression.<\/p><\/details>\n<details><summary>What minimum order quantity and customization options apply to vented capillary level-transmitter cables?<\/summary><p>As of November 2026, TEBAOFLEX manufactures custom vented capillary cables with PE, PUR or F46 (FEP) outer jackets and 2 to 6 shielded signal cores from a 50 m minimum order quantity (MOQ), with standard production lead times of 7 to 45 working days depending on fluoropolymer tooling and trial quantity. Supply your transmitter gland OD window, fluid exposure and capillary bore requirements for engineering confirmation.<\/p><\/details>\n<\/div>\n<div class=\"tbf-byline\">Project record prepared by <a href=\"https:\/\/tebaoflex-cable.com\/author\/zheng-lipeng\/\">Zheng LiPeng<\/a>, Manager, with the TEBAOFLEX cable engineering team in Taicang, Jiangsu \u00b7 Published <time datetime=\"2026-11-19\">19 November 2026<\/time>. More about our specialty extrusion lines and quality testing on our <a href=\"https:\/\/tebaoflex-cable.com\/about-us\/\">about us page<\/a>.<\/div>\n<div class=\"tbf-back\"><a href=\"https:\/\/tebaoflex-cable.com\/cases\/\">&larr; Back to all industrial cable application cases<\/a><\/div>\n<\/div>\n\n<script type=\"application\/ld+json\">{\"@context\": \"https:\/\/schema.org\", \"@type\": \"Article\", \"headline\": \"F46 (FEP) 4\u00d70.2 mm\u00b2 Vented Capillary Shielded Cable for Submersible Level Transmitters in Belarus\", \"description\": \"Case: 1,000 m custom F46 (FEP) 4\u00d70.2 mm\u00b2 vented capillary shielded cable for hydrostatic level transmitters in Belarus \u2014 6.99\u20137.11 mm OD and 1.60 mm bore.\", \"mainEntityOfPage\": {\"@type\": \"WebPage\", \"@id\": \"https:\/\/tebaoflex-cable.com\/cases\/fep-f46-vented-capillary-level-transmitter-cable-belarus\/\"}, \"url\": \"https:\/\/tebaoflex-cable.com\/cases\/fep-f46-vented-capillary-level-transmitter-cable-belarus\/\", \"inLanguage\": \"en\", \"image\": [{\"@type\": \"ImageObject\", \"url\": \"https:\/\/tebaoflex-cable.com\/wp-content\/uploads\/2026\/11\/fep-f46-vented-capillary-level-transmitter-cable-belarus-hero.webp\", \"width\": 1200, \"height\": 900}, {\"@type\": \"ImageObject\", \"url\": \"https:\/\/tebaoflex-cable.com\/wp-content\/uploads\/2026\/11\/fep-vented-level-cable-open-capillary-lumen-symmetrical-cores.webp\", \"width\": 1200, \"height\": 900}, {\"@type\": \"ImageObject\", \"url\": \"https:\/\/tebaoflex-cable.com\/wp-content\/uploads\/2026\/11\/fep-vented-level-cable-caliper-od-6-99mm-gland-check.webp\", \"width\": 1200, \"height\": 900}], \"author\": {\"@type\": \"Person\", \"@id\": \"https:\/\/tebaoflex-cable.com\/author\/zheng-lipeng\/\", \"name\": \"Zheng LiPeng\", \"url\": \"https:\/\/tebaoflex-cable.com\/author\/zheng-lipeng\/\", \"jobTitle\": \"Manager\", \"image\": \"https:\/\/tebaoflex-cable.com\/wp-content\/uploads\/2026\/09\/tebaoflex-author-headshot-100x100.jpg\", \"sameAs\": [\"https:\/\/www.linkedin.com\/in\/tebaoflexcable\/\"], \"worksFor\": {\"@id\": \"https:\/\/tebaoflex-cable.com\/#organization\"}}, \"publisher\": {\"@type\": \"Organization\", \"@id\": \"https:\/\/tebaoflex-cable.com\/#organization\", \"name\": \"TEBAOFLEX\", \"url\": \"https:\/\/tebaoflex-cable.com\/\"}, \"about\": [\"F46 (FEP) vented capillary level-transmitter cable\", \"4\u00d70.2 mm\u00b2 shielded hydrostatic level sensor cable\", \"Chemical-resistant fluoropolymer instrumentation cable\"], \"datePublished\": \"2026-11-19\", \"dateModified\": \"2026-11-19\"}<\/script>\n<script type=\"application\/ld+json\">{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"Why does a submersible hydrostatic level transmitter require a built-in capillary vent tube inside its cable?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Gauge-referenced submersible hydrostatic level sensors measure liquid depth by comparing total pressure at the submerged diaphragm against local atmospheric air pressure. Running an integrated hollow capillary vent tube inside the cable equalizes atmospheric pressure directly behind the sensing diaphragm so barometric weather swings do not introduce false level drift.\"}}, {\"@type\": \"Question\", \"name\": \"Why is an F46 (FEP) outer sheath chosen over PVC or standard polyurethane for corrosive level-sensor service?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"In chemical dosing tanks, acid\/alkali sumps, leachate wells and industrial effluent basins, chemical vapors and aggressive liquids swell PVC and hydrolyze standard polyurethane jackets. Fluorinated ethylene propylene (F46 \/ FEP) provides broad chemical inertness against concentrated acids, alkalis and process vapors across \u221240 \u00b0C to +70 \u00b0C while keeping a smooth, non-stick surface that resists biological fouling.\"}}, {\"@type\": \"Question\", \"name\": \"What makes extruding an F46 (FEP) jacket over PE-insulated cores and a PE capillary tube technically difficult?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"F46 (FEP) melts near 260 \u00b0C to 280 \u00b0C and is extruded above 330 \u00b0C, whereas polyethylene (PE) core insulation and a hollow PE capillary vent tube soften above 105 \u00b0C to 130 \u00b0C. Without thermal-barrier wrapping, calibrated crosshead drawdown and rapid cooling right after the die, melt heat can deform the PE cores or collapse the 1.60 mm hollow capillary lumen.\"}}, {\"@type\": \"Question\", \"name\": \"Why did TEBAOFLEX adjust the Belarus buyer's core layout from adjacent yellow\/red cores to a 90-degree symmetrical layout?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Placing two copper cores side by side on one side of a hollow capillary tube creates an asymmetric cross-section that flexes unevenly and concentrates radial compression onto one wall of the vent bore when tightened inside a transmitter cable gland. Spacing the four 0.2 mm\u00b2 cores symmetrically at 90-degree intervals separated by four equal polyamide tensile yarn sectors balances both hanging tension and gland compression.\"}}, {\"@type\": \"Question\", \"name\": \"What minimum order quantity and customization options apply to vented capillary level-transmitter cables?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"As of November 2026, TEBAOFLEX manufactures custom vented capillary cables with PE, PUR or F46 (FEP) outer jackets and 2 to 6 shielded signal cores from a 50 m minimum order quantity (MOQ), with standard production lead times of 7 to 45 working days depending on fluoropolymer tooling and trial quantity. Supply your transmitter gland OD window, fluid exposure and capillary bore requirements for engineering confirmation.\"}}]}<\/script>\n","protected":false},"excerpt":{"rendered":"<p>\u041a\u0435\u0439\u0441: 1,000 m \u0437\u0430\u043a\u0430\u0437\u043d\u043e\u0433\u043e \u044d\u043a\u0440\u0430\u043d\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u043e\u0433\u043e \u0432\u0435\u043d\u0442\u0438\u043b\u0438\u0440\u0443\u0435\u043c\u043e\u0433\u043e \u043a\u0430\u043f\u0438\u043b\u043b\u044f\u0440\u043d\u043e\u0433\u043e \u043a\u0430\u0431\u0435\u043b\u044f \u0441 \u043e\u0431\u043e\u043b\u043e\u0447\u043a\u043e\u0439 F46 (FEP) 4\u00d70.2 mm\u00b2 \u0434\u043b\u044f \u0433\u0438\u0434\u0440\u043e\u0441\u0442\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0443\u0440\u043e\u0432\u043d\u0435\u043c\u0435\u0440\u043e\u0432 \u0432 \u0411\u0435\u043b\u0430\u0440\u0443\u0441\u0438 \u2014 \u043d\u0430\u0440\u0443\u0436\u043d\u044b\u0439 \u0434\u0438\u0430\u043c\u0435\u0442\u0440 6.99\u20137.11 mm \u0438 \u0442\u0440\u0443\u0431\u043a\u0430 1.60 mm.<\/p>","protected":false},"author":1,"featured_media":8716,"parent":3117,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-8724","page","type-page","status-publish","has-post-thumbnail","hentry"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/tebaoflex-cable.com\/ru\/wp-json\/wp\/v2\/pages\/8724","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/tebaoflex-cable.com\/ru\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/tebaoflex-cable.com\/ru\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/tebaoflex-cable.com\/ru\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/tebaoflex-cable.com\/ru\/wp-json\/wp\/v2\/comments?post=8724"}],"version-history":[{"count":0,"href":"https:\/\/tebaoflex-cable.com\/ru\/wp-json\/wp\/v2\/pages\/8724\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/tebaoflex-cable.com\/ru\/wp-json\/wp\/v2\/pages\/3117"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/tebaoflex-cable.com\/ru\/wp-json\/wp\/v2\/media\/8716"}],"wp:attachment":[{"href":"https:\/\/tebaoflex-cable.com\/ru\/wp-json\/wp\/v2\/media?parent=8724"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}