{"id":664,"count":2,"description":"<strong>\u041f\u0440\u0438\u0431\u043e\u0440\u043d\u044b\u0435 \u043a\u0430\u0431\u0435\u043b\u0438 BS5308 \u0438 PAS5308 \u043f\u0435\u0440\u0435\u0434\u0430\u044e\u0442 \u0430\u043d\u0430\u043b\u043e\u0433\u043e\u0432\u044b\u0435 \u0438 \u0446\u0438\u0444\u0440\u043e\u0432\u044b\u0435 \u0441\u0438\u0433\u043d\u0430\u043b\u044b \u043c\u0435\u0436\u0434\u0443 \u043f\u043e\u043b\u0435\u0432\u044b\u043c\u0438 \u043f\u0440\u0438\u0431\u043e\u0440\u0430\u043c\u0438 \u0438 \u0441\u0438\u0441\u0442\u0435\u043c\u0430\u043c\u0438 \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f, \u0440\u0430\u0441\u0441\u0447\u0438\u0442\u0430\u043d\u044b \u043d\u0430 300\/500 \u0412 \u0438 \u044d\u043a\u0440\u0430\u043d\u0438\u0440\u043e\u0432\u0430\u043d\u044b \u0434\u043b\u044f \u0438\u0441\u043a\u0440\u043e\u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u044b\u0445 \u0446\u0435\u043f\u0435\u0439.<\/strong> TEBAOFLEX \u0438\u0437\u0433\u043e\u0442\u0430\u0432\u043b\u0438\u0432\u0430\u0435\u0442 \u044d\u0442\u0438 \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u0438 \u043d\u0430 \u0437\u0430\u043a\u0430\u0437 \u0441 \u043f\u043e\u043b\u0438\u044d\u0442\u0438\u043b\u0435\u043d\u043e\u0432\u043e\u0439 \u0438 \u041f\u0412\u0425 \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u0435\u0439, \u043d\u0435\u0431\u0440\u043e\u043d\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u0435 \u0438\u043b\u0438 \u0441 \u0431\u0440\u043e\u043d\u0451\u0439 \u0438\u0437 \u0441\u0442\u0430\u043b\u044c\u043d\u043e\u0439 \u043f\u0440\u043e\u0432\u043e\u043b\u043e\u043a\u0438, \u0441 \u043e\u0431\u0449\u0438\u043c \u043b\u0438\u0431\u043e \u0438\u043d\u0434\u0438\u0432\u0438\u0434\u0443\u0430\u043b\u044c\u043d\u044b\u043c \u0438 \u043e\u0431\u0449\u0438\u043c \u044d\u043a\u0440\u0430\u043d\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435\u043c.\r\n<strong>\u0421\u0442\u0430\u0442\u0443\u0441 \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u0430.<\/strong> BS 5308 Parts 1 \u0438 2 \u0431\u044b\u043b\u0438 \u043e\u0442\u043e\u0437\u0432\u0430\u043d\u044b \u0432 2005 \u0433\u043e\u0434\u0443, \u0430 PAS 5308-1:2009 \u0438 PAS 5308-2:2009 \u0431\u044b\u043b\u0438 \u043e\u0442\u043e\u0437\u0432\u0430\u043d\u044b BSI 3 \u0430\u043f\u0440\u0435\u043b\u044f 2024 \u0433\u043e\u0434\u0430. \u042d\u0442\u0438 \u043e\u0431\u043e\u0437\u043d\u0430\u0447\u0435\u043d\u0438\u044f \u043f\u043e-\u043f\u0440\u0435\u0436\u043d\u0435\u043c\u0443 \u0448\u0438\u0440\u043e\u043a\u043e \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u044e\u0442\u0441\u044f \u0432 \u043f\u0440\u043e\u0435\u043a\u0442\u043d\u044b\u0445 \u0441\u043f\u0435\u0446\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u044f\u0445, \u043d\u043e \u043d\u0438 \u043e\u0434\u043d\u043e \u0438\u0437 \u043d\u0438\u0445 \u043d\u0435 \u0434\u0435\u0439\u0441\u0442\u0432\u0443\u0435\u0442. \u0410\u043a\u0442\u0443\u0430\u043b\u044c\u043d\u044b\u043c \u0434\u043e\u043a\u0443\u043c\u0435\u043d\u0442\u043e\u043c, \u043e\u0445\u0432\u0430\u0442\u044b\u0432\u0430\u044e\u0449\u0438\u043c \u044d\u0442\u0438 \u043a\u0430\u0431\u0435\u043b\u0438, \u044f\u0432\u043b\u044f\u0435\u0442\u0441\u044f BS EN 50288-7:2005. <a href=\"\/ru\/pas-5308-instrumentation-cable-specification-guide\/\">\u041f\u0440\u043e\u0447\u0438\u0442\u0430\u0439\u0442\u0435 \u0440\u0443\u043a\u043e\u0432\u043e\u0434\u0441\u0442\u0432\u043e \u043f\u043e \u0441\u043f\u0435\u0446\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u0438<\/a> before issuing a cable schedule.\r\n\r\nSelect by three independent axes\r\nPart, Type and screening are separate decisions. Stating one does not define the cable, and Part 1 Type 2 on its own is an incomplete instruction.\r\n\r\nBS5308 and PAS5308 selection axes\r\nAxisOptionsChoose this when\r\n\r\n<strong>\u0427\u0430\u0441\u0442\u044c<\/strong> \u2014 \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u044fPart 1 \u043f\u043e\u043b\u0438\u044d\u0442\u0438\u043b\u0435\u043dPart 2 \u041f\u0412\u0425Part 1 \u0434\u043b\u044f \u0434\u043b\u0438\u043d\u043d\u044b\u0445 \u0443\u0447\u0430\u0441\u0442\u043a\u043e\u0432, \u043c\u0435\u043d\u044c\u0448\u0435\u0439 \u0451\u043c\u043a\u043e\u0441\u0442\u0438 \u0438 \u0431\u043e\u043b\u0435\u0435 \u0448\u0438\u0440\u043e\u043a\u043e\u0433\u043e \u0442\u0435\u043c\u043f\u0435\u0440\u0430\u0442\u0443\u0440\u043d\u043e\u0433\u043e \u0434\u0438\u0430\u043f\u0430\u0437\u043e\u043d\u0430. Part 2 \u0434\u043b\u044f \u043e\u0431\u0449\u0435\u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u044b\u0445 \u0442\u0440\u0430\u0441\u0441 \u043f\u0440\u0438 \u0443\u043c\u0435\u0440\u0435\u043d\u043d\u043e\u0439 \u0442\u0435\u043c\u043f\u0435\u0440\u0430\u0442\u0443\u0440\u0435.\r\n<strong>\u0422\u0438\u043f<\/strong> \u2014 \u0431\u0440\u043e\u043d\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435Type 1 \u043d\u0435\u0431\u0440\u043e\u043d\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u0439Type 2 \u0441 \u0431\u0440\u043e\u043d\u0451\u0439 \u0438\u0437 \u043e\u0446\u0438\u043d\u043a\u043e\u0432\u0430\u043d\u043d\u043e\u0439 \u0441\u0442\u0430\u043b\u044c\u043d\u043e\u0439 \u043f\u0440\u043e\u0432\u043e\u043b\u043e\u043a\u0438Type 1 \u0432\u043d\u0443\u0442\u0440\u0438 \u043b\u043e\u0442\u043a\u0430, \u043a\u043e\u0440\u043e\u0431\u0430 \u0438\u043b\u0438 \u0442\u0440\u0443\u0431\u044b. Type 2 \u0434\u043b\u044f \u043f\u0440\u044f\u043c\u043e\u0439 \u043f\u0440\u043e\u043a\u043b\u0430\u0434\u043a\u0438 \u0432 \u0433\u0440\u0443\u043d\u0442\u0435 \u0438\u043b\u0438 \u0442\u0430\u043c, \u0433\u0434\u0435 \u0432\u0435\u0440\u043e\u044f\u0442\u043d\u044b \u0440\u0430\u0437\u0434\u0430\u0432\u043b\u0438\u0432\u0430\u043d\u0438\u0435 \u0438 \u0443\u0434\u0430\u0440\u044b.\r\n<strong>\u042d\u043a\u0440\u0430\u043d<\/strong>CAM collectiveICAM individual and collectiveCAM where all circuits share a signal type and earth reference. ICAM for mixed signal levels, low-level analogue, or segregation of intrinsically safe circuits.\r\n\r\nConstruction range\r\n\r\nInstrumentation cable construction and governing standards\r\nElementSpecificationStandard\r\n\r\nConductorPlain annealed copper, Class 1 solid, Class 2 stranded or Class 5 flexibleBS EN 60228\r\nSizes0.5, 0.75, 1.0, 1.5 and 2.5\u00a0mm\u00b2\u2014\r\nUnitsPairs and triads, single unit to multi-unit builds\u2014\r\nInsulationPolyethylene Type 03, or PVCBS 6234\r\nScreenAluminium\/polyester tape with tinned copper drain wire\u2014\r\nArmourGalvanised steel wire over bedding, Type 2 only\u2014\r\nSheathPVC Type TM1, or low smoke zero halogenBS EN 50363\r\nVoltage300\/500\u00a0V (Uo\/U)\u2014\r\nFire performanceFlame propagation, single vertical wire and bunched cablesBS EN\/IEC 60332-1, 60332-3-24\r\n\r\nTemperature depends on the material system rather than on the Part or Type designation. Polyethylene insulated constructions are commonly rated \u221230\u00a0\u00b0C to +75\u00a0\u00b0C for fixed installation and PVC insulated constructions \u221220\u00a0\u00b0C to +65\u00a0\u00b0C. Confirm the figure for the specific build.\r\n\r\nIntrinsic safety\r\nThese constructions are designed to form part of an intrinsically safe system, and a blue sheath is the convention used to identify intrinsically safe circuits. Sheath colour does not by itself make a loop intrinsically safe: the cable inductance and capacitance per unit length must be checked against the permitted values for the complete loop. Request those parameters with the enquiry.\r\n\r\nWhat to send with an enquiry\r\n\r\nPart, Type and screening arrangement, or the construction described in full\r\nConductor class and cross-sectional area\r\nNumber of pairs or triads\r\nRoute conditions: buried, tray or trunking, ambient range, chemical exposure\r\nWhether the loop is intrinsically safe\r\nStandard to appear on the drum and in documentation, and any deviation already agreed\r\nLengths, drum or coil, marking and packaging\r\n\r\nMinimum order quantity is 50\u00a0m for standard and customised constructions alike, and lead time runs from 7 to 45 working days depending on product type, material position and the extent of customisation, as of August 2026. A written quotation from sales is the binding statement for any specific order.\r\n\r\nRelated routes\r\n\r\n<a href=\"\/ru\/pas-5308-instrumentation-cable-specification-guide\/\">\u0420\u0443\u043a\u043e\u0432\u043e\u0434\u0441\u0442\u0432\u043e \u043f\u043e \u0441\u043f\u0435\u0446\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u044f\u043c PAS 5308 \u0438 BS 5308<\/a> \u2014 \u0441\u0442\u0430\u0442\u0443\u0441 \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u0430, \u0442\u0440\u0438 \u043e\u0441\u0438 \u0432\u044b\u0431\u043e\u0440\u0430 \u0438 \u0447\u0442\u043e \u0443\u043a\u0430\u0437\u044b\u0432\u0430\u0442\u044c \u0442\u0435\u043f\u0435\u0440\u044c, \u043a\u043e\u0433\u0434\u0430 \u043e\u0431\u0430 \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u0430 \u043e\u0442\u043e\u0437\u0432\u0430\u043d\u044b.\r\n<a href=\"\/ru\/products\/oil-and-gas-cables\/\">\u041d\u0435\u0444\u0442\u0435\u0433\u0430\u0437\u043e\u0432\u044b\u0435 \u043a\u0430\u0431\u0435\u043b\u0438<\/a> \u2014 \u0441\u0438\u043b\u043e\u0432\u044b\u0435, \u0443\u043f\u0440\u0430\u0432\u043b\u044f\u044e\u0449\u0438\u0435 \u0438 \u0441\u0438\u0433\u043d\u0430\u043b\u044c\u043d\u044b\u0435 \u0442\u0440\u0430\u0441\u0441\u044b \u0434\u043b\u044f \u0431\u0443\u0440\u043e\u0432\u044b\u0445, \u043d\u0435\u0444\u0442\u0435\u043f\u0435\u0440\u0435\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u044e\u0449\u0438\u0445 \u0438 \u043c\u043e\u0440\u0441\u043a\u0438\u0445 \u043e\u0431\u044a\u0435\u043a\u0442\u043e\u0432.\r\n<a href=\"\/ru\/product\/type-p-signal-io-p-cable-600v-20-and-18-awg-unarmored\/\">\u0421\u0438\u0433\u043d\u0430\u043b\u044c\u043d\u044b\u0439 \u0438 \u0432\u0432\u043e\u0434\u0430\/\u0432\u044b\u0432\u043e\u0434\u0430 \u043a\u0430\u0431\u0435\u043b\u044c Type P<\/a> \u2014 \u0441\u0435\u0432\u0435\u0440\u043e\u0430\u043c\u0435\u0440\u0438\u043a\u0430\u043d\u0441\u043a\u0430\u044f \u043c\u043e\u0440\u0441\u043a\u0430\u044f \u0441\u0438\u0433\u043d\u0430\u043b\u044c\u043d\u0430\u044f \u0442\u0440\u0430\u0441\u0441\u0430, \u0434\u0440\u0443\u0433\u043e\u0435 \u0441\u0435\u043c\u0435\u0439\u0441\u0442\u0432\u043e \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u043e\u0432.\r\n<a href=\"\/ru\/solutions\/armoured-instrumentation-cables\/\">\u0411\u0440\u043e\u043d\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u0435 \u043f\u043e\u0434\u0432\u043e\u0434\u043d\u044b\u0435 \u043a\u0430\u0431\u0435\u043b\u0438 \u041a\u0418\u041f<\/a> \u2014 \u043f\u043e\u0434\u0432\u043e\u0434\u043d\u044b\u0435 \u0434\u0430\u0442\u0447\u0438\u043a\u0438 \u0438 \u0440\u0430\u0437\u0432\u0451\u0440\u0442\u044b\u0432\u0430\u043d\u0438\u0435, \u0430 \u043d\u0435 \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u044f \u043f\u043e PAS 5308.","link":"https:\/\/tebaoflex-cable.com\/ru\/products\/industrial-cables\/bs5308-instrumentation-cables\/","name":"\u041a\u0430\u0431\u0435\u043b\u0438 \u041a\u0418\u041f BS5308 \/ PAS5308","slug":"bs5308-instrumentation-cables","taxonomy":"product_cat","parent":45,"meta":[],"menu_order":0,"_links":{"self":[{"href":"https:\/\/tebaoflex-cable.com\/ru\/wp-json\/wp\/v2\/product_cat\/664","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/tebaoflex-cable.com\/ru\/wp-json\/wp\/v2\/product_cat"}],"about":[{"href":"https:\/\/tebaoflex-cable.com\/ru\/wp-json\/wp\/v2\/taxonomies\/product_cat"}],"up":[{"embeddable":true,"href":"https:\/\/tebaoflex-cable.com\/ru\/wp-json\/wp\/v2\/product_cat\/45"}],"wp:post_type":[{"href":"https:\/\/tebaoflex-cable.com\/ru\/wp-json\/wp\/v2\/product?product_cat=664"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}