Type 409 Class 2 Composite Screened Mining Cable 1.1–22 kV
Type 409 mining cable is a Class 2 composite screened cable for 1.1–22 kV open-cut trailing and reeling duties.
- Three flexible tinned-copper power cores plus one central extensible pilot
- Class 2 EPR R-EP-90 insulation
- Composite tinned-copper/polyester-yarn earth screen
- Heavy-duty HD-85-PCP sheath with braid reinforcement where applicable
- +90 °C maximum continuous operating temperature; −25 °C minimum installation temperature
- Suitable for pumps, shovels, draglines and blasthole drills as listed in the datasheet
Request a size and route review with the equipment and voltage details.
Type 409 mining cable for open-cut mobile equipment
Type 409 mining cable is a Class 2 composite screened trailing cable family for open-cut mining equipment. The supplied range spans 1.1 kV through 22 kV, allowing the requested voltage and conductor area to be matched to pumps, shovels, draglines, blasthole drills or another mobile installation. This page keeps the variants together, while the datasheet tables below retain their separate nominal dimensions, electrical values, earth-screen data, outer diameter and mass.
Its defining arrangement is three flexible power cores with one central extensible pilot, Class 2 EPR insulation and a composite earth screen made from tinned annealed copper wire and polyester yarn. A heavy-duty PCP sheath and, where applicable, polyaramid yarn braid reinforcement address the handling context described in the source. The cable is listed for free-air mobile equipment and open-cut trailing service, with very good immersion performance and very good flexibility.
- Voltage path: select Type 409.1, 409.3, 409.6, 409.11 or 409.22 from the equipment supply.
- Application fit: compare the route and handling method with the supplied trailing/reeling description before requesting a quotation.
- RFQ check: send the conductor area, length, equipment, drum or guide arrangement, termination details and required AS/NZS 2802 documents.
Type 409 composite screen construction
The Type 409 construction is organized around three phase cores and a single central pilot. The source differentiates the conductor/insulation tape treatment by voltage: polyester is listed for 1.1/1.1 kV, while semiconductive screening is listed for 3.3 kV and above.

| المعلمة | القيمة المدرجة في المصدر |
|---|---|
| نوى الطاقة | Tinned copper, three phase cores |
| Pilot | Single central extensible pilot core |
| العزل | Class 2 EPR compound, R-EP-90 |
| Earth screen | Tinned annealed copper wire and polyester yarn composite |
| غمد | Heavy-duty HD-85-PCP; polyaramid yarn braid reinforcement where applicable |
Confirm the screen and sheath arrangement against the selected voltage designation and the equipment termination design; the dimensional tables are the controlling source for size selection.
Where Type 409 is used
The supplied application note places this cable in open-cut mining, especially where mobile equipment needs a flexible trailing or reeling connection. Its single pilot is a useful identification point when comparing an existing cable marking.
- Pumps, shovels and draglines identified in the source application
- Blasthole drills and most reeling applications in open-cut mining
- Free-air mobile equipment routes where the selected voltage and conductor area match the machine
- Before ordering, verify route handling, drum or guide layout, terminations and the equipment protection interface
The datasheet does not provide current capacity, minimum bend radius, tensile load or travel speed. Treat those as project confirmation items rather than inferred Type 409 ratings.
Type 409 Class 2 Composite Screened Mining Cable 1.1–22 kV technical data
The dimensional and electrical values below are transcribed from the supplied PDF for Type 409 mining cable. The tables are retained by voltage, screen option or construction section as presented in the source. Source ordering codes are included where present in the extracted table; blank source cells are not assigned new values.
Use the relevant area, conductor dimensions, insulation or covering thickness, nominal diameter and mass together. The source does not create a universal current-capacity, bend-radius, pulling-load or travel-speed value for this product.
TYPE 409.1 - 1.1 kV
| جزء | Area mm2 | Cond. Dia. mm | Insul. mm | AC Res. oh/km | React. oh/km | Volt Drop mV/A.m | Cap. uF/km | Earth mm2 | Sheath mm | Cable Dia. mm | Mass kg/100m |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 6-409-1 | 6 | 3.5 | 1.5 | 4.32 | 0.145 | 7.49 | 0.259 | 8.2 | 3.8 | 32.2 | 160 |
| 10-409-1 | 10 | 4.6 | 1.5 | 2.58 | 0.133 | 4.47 | 0.314 | 8.2 | 3.8 | 34.3 | 185 |
| 16-409-1 | 16 | 6.2 | 1.6 | 1.58 | 0.120 | 2.74 | 0.379 | 10 | 4.0 | 38.1 | 235 |
| 25-409-1 | 25 | 7.2 | 1.6 | 0.951 | 0.113 | 1.66 | 0.432 | 12 | 4.3 | 40.9 | 290 |
| 35-409-1 | 35 | 8.4 | 1.6 | 0.698 | 0.108 | 1.22 | 0.493 | 14 | 4.6 | 44.0 | 345 |
| 50-409-1 | 50 | 9.7 | 1.7 | 0.523 | 0.107 | 0.925 | 0.526 | 14 | 5.0 | 49.1 | 430 |
| 70-409-1 | 70 | 12.0 | 1.8 | 0.346 | 0.0997 | 0.624 | 0.599 | 16 | 5.4 | 54.8 | 550 |
| 95-409-1 | 95 | 13.3 | 2.0 | 0.271 | 0.0971 | 0.499 | 0.591 | 22 | 6.0 | 60.0 | 675 |
| 120-409-1 | 120 | 15.3 | 2.1 | 0.210 | 0.0932 | 0.398 | 0.640 | 25 | 6.4 | 65.2 | 815 |
| 150-409-1 | 150 | 17.2 | 2.3 | 0.166 | 0.0928 | 0.329 | 0.652 | 37 | 6.9 | 72.3 | 1025 |
| 185-409-1 | 185 | 18.8 | 2.5 | 0.137 | 0.0915 | 0.285 | 0.657 | 40 | 7.4 | 77.8 | 1200 |
| 240-409-1 | 240 | 21.7 | 2.8 | 0.106 | 0.0905 | 0.241 | 0.672 | 58 | 8.2 | 88.3 | 1555 |
| 300-409-1 | 300 | 24.3 | 3.0 | 0.0849 | 0.0883 | 0.212 | 0.719 | 63 | 8.8 | 95.7 | 1860 |
TYPE 409.3 - 3.3 kV
| جزء | Area mm2 | Cond. Dia. mm | Insul. mm | AC Res. oh/km | React. oh/km | Volt Drop mV/A.m | Cap. uF/km | Earth mm2 | Sheath mm | Cable Dia. mm | Mass kg/100m |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 16-409-3 | 16 | 6.2 | 3.0 | 1.58 | 0.131 | 2.75 | 0.255 | 14 | 5.3 | 47.4 | 335 |
| 25-409-3 | 25 | 7.2 | 3.0 | 0.951 | 0.125 | 1.66 | 0.280 | 15 | 5.6 | 50.5 | 400 |
| 35-409-3 | 35 | 8.4 | 3.0 | 0.698 | 0.119 | 1.23 | 0.311 | 16 | 5.9 | 53.6 | 460 |
| 50-409-3 | 50 | 9.7 | 3.0 | 0.523 | 0.115 | 0.928 | 0.347 | 17 | 6.3 | 57.8 | 545 |
| 70-409-3 | 70 | 12.0 | 3.0 | 0.346 | 0.107 | 0.627 | 0.408 | 19 | 6.6 | 62.8 | 665 |
| 95-409-3 | 95 | 13.3 | 3.0 | 0.271 | 0.102 | 0.502 | 0.439 | 21 | 7.1 | 66.5 | 765 |
| 120-409-3 | 120 | 15.3 | 3.0 | 0.210 | 0.0985 | 0.402 | 0.492 | 28 | 7.4 | 72.0 | 935 |
| 150-409-3 | 150 | 17.2 | 3.0 | 0.166 | 0.0954 | 0.332 | 0.541 | 32 | 7.8 | 76.7 | 1095 |
| 185-409-3 | 185 | 18.8 | 3.0 | 0.137 | 0.0942 | 0.288 | 0.584 | 42 | 8.2 | 82.5 | 1290 |
| 240-409-3 | 240 | 21.7 | 3.0 | 0.106 | 0.0906 | 0.242 | 0.659 | 48 | 8.8 | 89.8 | 1560 |
| 300-409-3 | 300 | 24.3 | 3.0 | 0.0849 | 0.0890 | 0.213 | 0.727 | 63 | 9.4 | 97.8 | 1900 |
TYPE 409.6 - 6.6 kV
| جزء | Area mm2 | Cond. Dia. mm | Insul. mm | AC Res. oh/km | React. oh/km | Volt Drop mV/A.m | Cap. uF/km | Earth mm2 | Sheath mm | Cable Dia. mm | Mass kg/100m |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 16-409-6 | 16 | 6.2 | 5.0 | 1.58 | 0.143 | 2.75 | 0.181 | 17 | 6.4 | 58.2 | 475 |
| 25-409-6 | 25 | 7.2 | 5.0 | 0.951 | 0.137 | 1.66 | 0.193 | 19 | 6.7 | 61.7 | 560 |
| 35-409-6 | 35 | 8.4 | 5.0 | 0.698 | 0.130 | 1.23 | 0.212 | 21 | 7.0 | 64.7 | 625 |
| 50-409-6 | 50 | 9.7 | 5.0 | 0.523 | 0.124 | 0.931 | 0.234 | 22 | 7.3 | 68.3 | 715 |
| 70-409-6 | 70 | 12.0 | 5.0 | 0.346 | 0.116 | 0.632 | 0.271 | 23 | 7.7 | 73.9 | 860 |
| 95-409-6 | 95 | 13.3 | 5.0 | 0.271 | 0.113 | 0.509 | 0.292 | 30 | 8.1 | 78.2 | 1005 |
| 120-409-6 | 120 | 15.3 | 5.0 | 0.210 | 0.108 | 0.409 | 0.325 | 32 | 8.5 | 83.4 | 1160 |
| 150-409-6 | 150 | 17.2 | 5.0 | 0.166 | 0.105 | 0.340 | 0.354 | 46 | 8.9 | 89.4 | 1380 |
| 185-409-6 | 185 | 18.8 | 5.0 | 0.136 | 0.102 | 0.294 | 0.381 | 49 | 9.3 | 93.7 | 1545 |
| 240-409-6 | 240 | 21.7 | 5.0 | 0.106 | 0.0981 | 0.250 | 0.426 | 53 | 9.9 | 101 | 1830 |
| 300-409-6 | 300 | 24.3 | 5.0 | 0.0845 | 0.0959 | 0.221 | 0.467 | 71 | 10.4 | 109 | 2195 |
TYPE 409.11 - 11 kV
| جزء | Area mm2 | Cond. Dia. mm | Insul. mm | AC Res. oh/km | React. oh/km | Volt Drop mV/A.m | Cap. uF/km | Earth mm2 | Sheath mm | Cable Dia. mm | Mass kg/100m |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 25-409-11 | 25 | 7.2 | 7.6 | 0.951 | 0.150 | 1.67 | 0.150 | 24 | 8.1 | 76.1 | 810 |
| 35-409-11 | 35 | 8.4 | 7.6 | 0.698 | 0.143 | 1.23 | 0.163 | 30 | 8.4 | 79.8 | 920 |
| 50-409-11 | 50 | 9.7 | 7.6 | 0.523 | 0.136 | 0.936 | 0.178 | 32 | 8.7 | 83.2 | 1020 |
| 70-409-11 | 70 | 12.0 | 7.6 | 0.346 | 0.127 | 0.638 | 0.204 | 35 | 9.1 | 88.8 | 1185 |
| 95-409-11 | 95 | 13.3 | 7.6 | 0.271 | 0.124 | 0.516 | 0.219 | 48 | 9.6 | 93.9 | 1365 |
| 120-409-11 | 120 | 15.3 | 7.6 | 0.210 | 0.119 | 0.418 | 0.241 | 53 | 9.9 | 98.8 | 1540 |
| 150-409-11 | 150 | 17.2 | 7.6 | 0.165 | 0.114 | 0.347 | 0.261 | 56 | 10.3 | 104 | 1730 |
| 185-409-11 | 185 | 18.8 | 7.6 | 0.136 | 0.111 | 0.304 | 0.279 | 56 | 10.7 | 108 | 1900 |
| 240-409-11 | 240 | 21.7 | 7.6 | 0.106 | 0.107 | 0.261 | 0.309 | 77 | 11.3 | 116 | 2280 |
TYPE 409.22 - 22 kV
| جزء | Area mm2 | Cond. Dia. mm | Insul. mm | AC Res. oh/km | React. oh/km | Volt Drop mV/A.m | Cap. uF/km | Earth mm2 | Sheath mm | Cable Dia. mm | Mass kg/100m |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 35-409-22 | 35 | 8.4 | 10.5 | 0.698 | 0.160 | 1.24 | 0.147 | 53 | 10.0 | 102 | 1420 |
| 50-409-22 | 50 | 9.7 | 10.5 | 0.523 | 0.153 | 0.944 | 0.159 | 56 | 10.3 | 106 | 1540 |
| 70-409-22 | 70 | 12.0 | 10.5 | 0.346 | 0.143 | 0.648 | 0.178 | 60 | 10.7 | 111 | 1735 |
| 95-409-22 | 95 | 13.3 | 10.5 | 0.271 | 0.138 | 0.527 | 0.189 | 62 | 11.1 | 115 | 1870 |
5 technical tables were transcribed from the supplied datasheet; confirm final selection against the original PDF and project cable schedule.
Type 409 standard and service window
The product sheet identifies the cable as a Type 409 Class 2 cable to AS/NZS 2802. The table below records the source-listed range and operating limits without adding a certification conclusion.
| المعلمة | القيمة المدرجة في المصدر |
|---|---|
| معيار المنتج | AS/NZS 2802 |
| Voltage range | 1.1 kV to 22 kV |
| أقصى درجة حرارة تشغيل مستمرة | +90 °C |
| Minimum installation temperature | −25 °C |
| تثبيت | Free air, mobile equipment and open-cut mine trailing service |
| Oil / water performance | Very good immersion performance and very good flexibility |
| أداء اللهب | C1 |
For an RFQ, state the required voltage designation, conductor area, source-document scope and destination marking requirements.
خيارات الكابلات ذات الصلة
قارن بين خيارات الكابلات هذه حسب مجموعة الخدمات، والحركة، والحمل، والجهد، ومتطلبات الإرسال.
كابل منجم فحم تحت الأرض من النوع 240، من 1.1 كيلو فولت إلى 11 كيلو فولت
خيار كابل ذي صلة لتطبيق أو وظيفة مختلفة.
عرض المنتجكابل تعدين من النوع 241.1 بجهد 1.1 كيلو فولت | عائلة النوع 241
خيار كابل ذي صلة لتطبيق أو وظيفة مختلفة.
عرض المنتجكابل طاقة التعدين المدرع والمحمي من النوع TYPE260
خيار كابل ذي صلة لتطبيق أو وظيفة مختلفة.
عرض المنتجاطلب توصية بشأن الكابلات وعرض سعر
يرجى إرسال الخدمات المطلوبة، وطول الكابل، والقدرات الميكانيكية، والبيئة، ونوع التوصيلات، والكمية. سيقوم فريقنا بمراجعة الطلب قبل تقديم عرض السعر.
- يرجى تضمين اسم المنتج أو رمز المنتج (SKU) بالإضافة إلى طول الكابل المطلوب وكميته.
- أرفق المواصفات أو الرسم أو ورقة البيانات عند توفرها.