Type 506 / Type 512 / Type 518 / Type 524 BS 6708 320/550 V Armoured Control Cable

Type 506 / Type 512 / Type 518 / Type 524 mining cable for control connections inside large mining machines and interconnection between surrounding machine segments, with the source-defined 320/550 V rating and 1.5 kV test reference.

  • Model: Type 506 / Type 512 / Type 518 / Type 524
  • Conductor and insulation: flexible tinned copper with the insulation and core construction listed for this model in the supplied PDF
  • Screen, pilot, earth and armour arrangement preserved from the source datasheet
  • Heavy-duty chloroprene or PCP outer protection as listed for this model
  • Original Type datasheet available as the product download

Send the equipment, voltage, conductor area, route, quantity and document requirements for an RFQ.

معلومات المنتج
ماركة
تيباوفليكس
نظرة عامة على المنتج

Type 506 / Type 512 / Type 518 / Type 524 for control connections inside large mining machines and interconnection between surrounding machine segments

Type 506 / Type 512 / Type 518 / Type 524 mining cable is specified in the supplied BS 6708 datasheet for control connections inside large mining machines and interconnection between surrounding machine segments. This page keeps the source-listed voltage, test reference, core functions and dimensional tables together so a procurement engineer can compare the requested model against the cable marking and the equipment connection. The editorial focus is the auxiliary-control function rather than the primary power path, not a generic promise of performance.

The supplied construction uses multiple individually screened cores laid in contact with flexible galvanized steel armour between inner and outer sheaths, with EPR or TPE insulation and a heavy-duty chloroprene jacket. That arrangement matters because This family is intended for control and interconnection duties; it should not be presented as a primary high-current power cable. The family should therefore be selected by model, core function and installation route as well as by voltage. The مجموعة كابلات التعدين والأنفاق provides the wider TEBAOFLEX product context.

  • اختر حسب: confirm core count, circuit function, screen termination and whether the cable is carrying control/auxiliary circuits rather than machine power.
  • تأكيد قبل الطلب: existing sheath marking, conductor area, cable length, route, support or handling system, terminations and the required inspection documents.
  • Do not infer: values not listed in the supplied PDF, such as a different current basis, water/oil/UV performance, certification scope or mechanical interchangeability.

For machine interconnection projects, pair this control-cable data with the Mining & Tunnelling solutions page so the control route and primary power route are reviewed as separate requirements.

For a technical quotation, send the equipment nameplate or existing cable marking, voltage and size requirement, installation conditions, quantity, destination and any project-specific test or documentation requirement.

بناء

Type 506 / Type 512 / Type 518 / Type 524 construction

The cross-section below is the supplied construction drawing for Type 506 / Type 512 / Type 518 / Type 524. The ordering decision is driven by This family is intended for control and interconnection duties; it should not be presented as a primary high-current power cable.

Type 506 / Type 512 / Type 518 / Type 524 cable cross-section showing the supplied power, pilot, earth, screen and protection arrangement
Supplied Type 506 / Type 512 / Type 518 / Type 524 cross-section; the exact core and armour arrangement must be checked against the product datasheet.

Source-listed construction

عنصر التركيبالقيمة المدرجة في المصدر
موصلElectrolytic stranded tinned copper wire, IEC 60228 Class 5
العزلEPR or TPE insulation
شاشةTinned copper and nylon braided screen over cores
التسديدة السهلةAll cores laid up in contact with each other
درعدرع فولاذي مجلفن مرن
غمدHeavy-duty chloroprene outer sheath
Cable designComposite individual screens with pliable armour between inner and outer sheaths

Do not use the drawing as a substitute for the dimensional tables. Confirm the cable end preparation, screen and earth termination, armour bonding and machine interface with the equipment documentation before installation.

التطبيقات

Type 506 / Type 512 / Type 518 / Type 524 applications

Type 506 / Type 512 / Type 518 / Type 524 mining cable application with mixed underground and surface mining equipment
Media-library application scene showing mixed underground and surface mining equipment; used for application context, not as a model-specific construction proof.

The supplied datasheet identifies this cable for control connections inside large mining machines and interconnection between surrounding machine segments. Google result patterns for the BS 6708 family also separate cables by equipment duty, voltage class, core function and whether the route is armoured, screened, flat or auxiliary. That is why this page keeps the Type 506 / Type 512 / Type 518 / Type 524 construction separate from nearby Type numbers.

  • Primary duty: control connections inside large mining machines and interconnection between surrounding machine segments.
  • Model boundary: This family is intended for control and interconnection duties; it should not be presented as a primary high-current power cable.
  • Project check: match the cable marking, core map, voltage, termination, route geometry and handling method to the machine drawing.
  • Environmental review: confirm the actual mine/quarry conditions and any authority, inspection or documentation requirements; do not infer a certification or material-resistance claim from the model number.

For primary low-voltage power rather than control interconnection, compare the Type 70/71 mining cable; the conductor purpose and termination schedule should decide the selection.

The cable should be released only after the equipment route, required length, conductor area, core functions and connection details are agreed. If the intended duty is different from the source-listed application, request an engineering review through the quotation process.

تحديد

Type 506 / Type 512 / Type 518 / Type 524 specifications

The summary below identifies the supplied model family. The source-transcribed tables that follow retain the PDF's dimensional, electrical and construction values, including available sizes, resistance, current, diameter, mass, bending or pulling data when the PDF provides them.

Selection itemSource-linked value
نموذجType 506 / Type 512 / Type 518 / Type 524
الجهد المقنن320/550 V
جهد الاختبار1.5 kV
طلبcontrol connections inside large mining machines and interconnection between surrounding machine segments
معيار المنتجBS 6708

Complete source-transcribed technical tables

Source PDF: BS6708_TYPE_506_TYPE_512_TYPE_518_TYPE_524_320_550V_ARMOURED_CONTROL_CABLE_datasheet.pdf; 3 pages; 6 extracted tables. Values are not recalculated or replaced by third-party values.

Source table 1, PDF page 1
المعلمةقيمة
موصلElectrolytic stranded tinned copper wire, IEC 60228 Class 5
العزلEPR or TPE insulation
شاشةTinned copper and nylon braided screen over cores
التسديدة السهلةAll cores are laid up in contact with each other
أغطية الفراشRubber based bedding compound
درعدرع فولاذي مجلفن مرن
الغلاف الخارجيHeavy duty chloroprene outer sheath
Source table 2, PDF page 1
المعلمةقيمة
معيارBS 6708
الجهد المقنن320/550 V
جهد الاختبار1.5 kV
Cable designComposite individual screens with pliable armour between inner and outer sheaths
Source table 1, PDF page 2
CORE DIMENSIONS
يكتبNominal cross sectionConductors number and cross sectionStranding mmCond. dia. mmInsul. thick. mm
Type 50618x1.3418x1.3419/0.301.600.4
Type 5126x1.346x1.3419/0.301.600.4
Type 51812x1.3412x1.3419/0.301.600.4
Type 52424x0.9324x0.9319/0.251.300.4
Source table 2, PDF page 2
CABLE DIMENSIONS
يكتبInner sheath radial thick. mmMin. inner sheath dia. mmMax. inner sheath dia. mmArmour size mmOuter sheath thick. mmMin. OD mmMax. OD mm
Type 5061.516.518.57/0.451.822.825.3
Type 5123.514.816.87/0.451.822.123.6
Type 5181.814.816.87/0.451.822.123.6
Type 5241.517.919.97/0.451.824.226.7
Source table 1, PDF page 3
MECHANICAL AND ELECTRICAL DETAILS
يكتبMin. bend radius mmApprox. weight kg/kmCopper weight kg/kmCurrent rating at 25 deg CMax. DC resistance at 20 deg C ohm/kmArmour DC res. ohm/km3 phase voltage drop mV/A/m
Type 50625314004501115.44.7630
Type 51223610201501615.45.4030
Type 51823612003001315.45.4030
Type 5242671600450822.14.5043
Source table 2, PDF page 3
المعلمةقيمة
Max. DC resistance at 20 deg C - conductors15.4 ohm/km for Types 506, 512 and 518; 22.1 ohm/km for Type 524
Max. DC resistance at 20 deg C - armour4.76 ohm/km for Type 506; 5.40 ohm/km for Types 512 and 518; 4.50 ohm/km for Type 524
3 screens in parallel connection37.3 ohm/km for Types 506, 512 and 518; 44.7 ohm/km for Type 524
DC or single phase voltage drop34 mV/A/m for Types 506, 512 and 518; 50 mV/A/m for Type 524
3 phase voltage drop30 mV/A/m for Types 506, 512 and 518; 43 mV/A/m for Type 524
Continuous current ratingAt 25 deg C ambient

Use the table values with the equipment drawing and approved termination plan. If the requested conductor area, current basis, mechanical limit or environmental condition is not listed in the supplied PDF, treat it as a quotation-stage confirmation item.

المعايير

Type 506 / Type 512 / Type 518 / Type 524 standards and references

الموضوعSource-linked reference
معيار المنتجBS 6708
الجهد المقنن320/550 V
جهد الاختبار1.5 kV
Source applicationcontrol connections inside large mining machines and interconnection between surrounding machine segments

The product page preserves the BS 6708 reference appearing in the supplied PDF. The BSI record currently identifies BS 6708:1998 as withdrawn on 22 May 2026; this status note is a standards-reference update, not a claim that the product is currently certified or approved. See the official BSI BS 6708 scope record for the published status.

For an RFQ, state the required standard documents, inspection scope, test report, cable marking, destination rules and any replacement-equivalence requirement. The model number alone does not establish legal installation compliance.

قارن حسب الرسوم

خيارات الكابلات ذات الصلة

قارن بين خيارات الكابلات هذه حسب مجموعة الخدمات، والحركة، والحمل، والجهد، ومتطلبات الإرسال.

عرض أسعار قائم على الهندسة

اطلب توصية بشأن الكابلات وعرض سعر

يرجى إرسال الخدمات المطلوبة، وطول الكابل، والقدرات الميكانيكية، والبيئة، ونوع التوصيلات، والكمية. سيقوم فريقنا بمراجعة الطلب قبل تقديم عرض السعر.

  • يرجى تضمين اسم المنتج أو رمز المنتج (SKU) بالإضافة إلى طول الكابل المطلوب وكميته.
  • أرفق المواصفات أو الرسم أو ورقة البيانات عند توفرها.

    اختياري: إرفاق مواصفات الكابل أو الرسم أو ورقة البيانات أو صورة المنتج (PDF، DOC، DOCX، XLS، XLSX، CSV، JPG أو PNG؛ بحد أقصى 10 ميجابايت).

    بإرسال هذا النموذج، فإنك توافق على أن تستخدم شركة TEBAOFLEX معلومات الاتصال والملفات المُقدمة لمراجعة استفسارك والرد عليه. تُستخدم الملفات لإعداد عروض الأسعار والتواصل الهندسي المتعلق بطلبك. راجع سياسة ملفاتنا سياسة الخصوصية للحصول على معلومات حديثة حول معالجة البيانات والاحتفاظ بها.

    * الحقول المطلوبة. يرجى تضمين تفاصيل الكابل الرئيسي أو التطبيق للمراجعة.