2YSLGCGOEU 250/250 V Signal and Control Cable
250/250 V screened signal, control and bus cable with paired cores, PE insulation and tinned copper braid screen.
2YSLGCGOEU is a screened signal, control and bus cable for open-cast mining, conveyor systems, material handling and automation circuits. The supplied VDE sheet specifies paired cores, flexible stranded copper conductors, PE type 2YI1 insulation, EM2 inner and outer sheaths and a tinned copper braid screen. It names VDE 0250 Part 812 and DIN VDE 0295 and provides size data for 2 × 2 × 1, 5 × 2 × 1, 10 × 2 × 1 and 20 × 2 × 1 arrangements. Voltage, test, thermal and mechanical fields were added after the authorized cross-check of three public technical references for the same designation: 250/250 V rated voltage, 350 V peak maximum AC and DC operating voltage, 1.5 kV test voltage, 60 °C maximum conductor temperature, 150 °C short-circuit temperature, fixed service from −40 °C to +60 °C and fully flexible service from −25 °C to +60 °C. The reference set also identifies a 15 N/mm² tensile value and ±25°/m torsion value. Confirm the pair count, protocol or control function, route, movement duty, screening termination, marking, length and required test documents with TEBAOFLEX before quotation.
2YSLGCGOEU paired-core construction
2YSLGCGOEU is arranged as paired cores in layers with a continuous non-hygroscopic serving over the conductor assembly. The supplied drawing identifies flexible Class 5 copper conductors, PE type 2YI1 insulation, EM2 inner and outer sheaths and a tinned copper wire braid screen.

| Parámetro | Valor indicado en la fuente |
|---|---|
| Conductores | Flexible stranded copper conductor, Class 5 according to DIN VDE 0295 |
| Aislamiento | PE insulation type 2YI1 |
| elemento de cable | Cores laid up in pairs in layers with continuous non-hygroscopic serving |
| vaina interior | CM type EM2 |
| Pantalla | Tinned copper wire braid |
| Vaina exterior | CM type EM2 |
The paired layout and braid screen are the key selection points for process-data, automation and bus applications. Confirm the transmission requirement and final pair count rather than treating every control cable as a bus cable.
Applications for 2YSLGCGOEU
The supplied application identifies control, signalling and bus connections for electric and electronic equipment, measured-value processing, process-data systems and automation units in open-cast mining. It is suitable for laying alongside conveyor belts and on material-handling equipment.

- Open-cast mining control, signalling and bus circuits
- Measured-value processing, process-data systems and automation units
- Routes alongside conveyor belts and on material-handling equipment
- Fixed or fully flexible installation within the cross-checked temperature and mechanical reference window
- Confirm pair count, protocol/transmission requirement, route, movement, screening termination and final marking before quotation
The 250/250 V rating is a signal/control-circuit reference, not a substitute for the equipment interface or communication-system specification. Include the required pair arrangement and cable length in the RFQ.
2YSLGCGOEU specifications
The supplied VDE sheet provides the construction and size table. Voltage, test, thermal and mechanical fields below were cross-checked on 2026-08-30 against three public technical references for the same 2YSLGCGOEU designation, as authorized for this upload. Confirm the final cable marking and project documentation before order release.
| Parámetro | Valor indicado en la fuente |
|---|---|
| Rated voltage U₀/U | 250/250 V |
| Maximum permissible AC operating voltage | 350 V peak value |
| Maximum permissible DC operating voltage | 350 V peak value |
| Voltaje de prueba de CA | 1.5 kV |
| Temperatura máxima de funcionamiento del conductor | 60 °C |
| Temperatura máxima del conductor en cortocircuito | 150 °C |
| Fixed ambient temperature | −40 °C to +60 °C |
| Fully flexible ambient temperature | −25 °C to +60 °C |
| Carga de tracción máxima | 15 N/mm² |
| Maximum torsional stress | ±25°/m |
| Radio de curvatura mínimo | According to DIN VDE 0298 Part 3; public references also list 4 × Ø fixed and 5 × Ø moving |
| Número de almas × sección nominal | Minimum OD (mm) | Maximum OD (mm) | Peso nominal (kg/km) |
|---|---|---|---|
| 2 × 2 × 1 | 11.0 | 13.0 | 245 |
| 5 × 2 × 1 | 16.0 | 19.0 | 440 |
| 10 × 2 × 1 | 20.0 | 23.0 | 700 |
| 20 × 2 × 1 | 25.0 | 29.0 | 1040 |
Standard values are based on the supplied technical data table. Other packing forms and delivery lengths are available on request.
2YSLGCGOEU standards and cross-checked reference fields
The supplied VDE sheet names VDE 0250 Part 812 and DIN VDE 0295. The voltage, temperature and mechanical fields are included after the authorized three-source public cross-check for this designation.
| Parámetro | Valor indicado en la fuente |
|---|---|
| Cable standard | VDE 0250 Parte 812 |
| Norma del conductor | DIN VDE 0295 |
| Tensión nominal | 250/250 V |
| Voltaje de prueba de CA | 1.5 kV |
| Fixed ambient temperature | −40 °C to +60 °C |
| Fully flexible ambient temperature | −25 °C to +60 °C |
| Flame reference | VDE 0482-332-1-2 / IEC 60332-1-2 — public technical reference cross-check |
| Oil reference | EN 60811-404 — public technical reference cross-check |
For quotation, provide the intended pair/core configuration, bus or control function, route, fixed/moving duty and required test documentation. Public reference values do not replace the final TEBAOFLEX order drawing.
Opciones de cable relacionadas
Compare estas opciones de cable según la combinación de servicios, el movimiento, la carga, el voltaje y los requisitos de transmisión.
Cable de transporte y minería de media tensión F-(N)TSCGEWÖU 3,6/6–18/30 kV
Para rutas de guirnaldas y cintas transportadoras con recorridos repetitivos.
Ver productoCable (N)SSHCOEU de 0,6/1 kV con protección EMC para variador de frecuencia (VFD) para minería.
Una opción de cable relacionada para una aplicación o perfil de trabajo diferente.
Ver productoSolicite una recomendación y un presupuesto de cables.
Indique los servicios requeridos, la longitud del cable, la carga mecánica, el entorno, el tipo de terminación y la cantidad. Nuestro equipo revisará la solicitud antes de elaborar un presupuesto.
- Incluya el nombre del producto o SKU, así como la longitud y la cantidad de cable requeridas.
- Adjunte una especificación, un dibujo o una hoja de datos cuando esté disponible.