Zapytaj o ofertę
KABLE PRZEMYSŁOWE TEBAOFLEX

NSGAFOEU 1.8/3kV Medium Voltage Single-Core Cable

NSGAFOEU 1.8/3kV Medium Voltage Single-Core Cable is a TEBAOFLEX cable for the application and operating conditions identified in the original product record. These model distinctions should be preserved in the quotation, order confirmation, production marking and test documentation. A halogen-free compound or metallic screen changes the cable designation and should not be added as a generic NSGAFOEU attribute. The following figures are transcribed from the supplied 1.8/3 kV table. Send the exact size, length, installation duty and documentation requirements for a technical quotation.

Informacje o produkcie
SKU
TF-NSGAFOEU
Marka
TEBAOFLEX
Przegląd produktu

NSGAFOEU 1.8/3kV Medium Voltage Single-Core Cable is a TEBAOFLEX cable for the application and operating conditions identified in the original product record. These model distinctions should be preserved in the quotation, order confirmation, production marking and test documentation. A halogen-free compound or metallic screen changes the cable designation and should not be added as a generic NSGAFOEU attribute. The following figures are transcribed from the supplied 1.8/3 kV table. Minimum and maximum diameters help with conduit fill, gland selection, termination space, support cleats and routing clearance. Confirm final production dimensions for the selected cross-section before freezing equipment interfaces. Data check required: the 1 x 400 mm² row in the supplied image lists a 40.0 mm minimum diameter and a 34.6 mm maximum diameter. Because a minimum cannot exceed the maximum, this row should remain unpublished as a purchasable variation until the original datasheet or factory specification confirms both values. NSGAFOEU is a 1.8/3 kV medium-voltage single-core cable for protected fixed wiring and selected movable connections in railway vehicles, buses, pipes, enclosed ducts and switchgear. Its Class 5 tinned-copper conductor and rubber construction combine routing flexibility with a compact, mechanically protected power connection. The source record places this product in industrial cables. Before ordering, confirm the exact product variant, conductor or core arrangement, system rating, route conditions, equipment connection and required documentation against the project specification.

Budowa

NSGAFOEU 1.8/3kV Medium Voltage Single-Core Cable construction

Budowa kabla

  1. Żyła przewodząca: Flexible stranded tinned-copper wires, Class 5 according to DIN VDE 0295 / IEC 60228.
  2. Inner conductor layer: A semiconducting layer is included in the 3.6/6 kV construction. This layer is not identified as part of the 1.8/3 kV build in the supplied diagram.
  3. Izolacja: EPR rubber compound type 3GI3 or 3GJ3.
  4. Powłoka zewnętrzna: Chlorinated rubber compound type 5GM3, stated as oil-resistant and flame-retardant.
Zastosowania

NSGAFOEU 1.8/3kV Medium Voltage Single-Core Cable applications

AC Single-Core Installation Considerations

  • Keep circuit conductors together: Arrange all phases of an AC circuit in the specified trefoil or flat formation so their magnetic fields remain balanced and loop impedance is controlled.
  • Avoid individual ferromagnetic entries: Do not pass each AC single-core phase separately through a closed steel gland plate or steel conduit without an approved non-magnetic arrangement. Alternating magnetic flux can cause eddy-current heating.
  • Use equal phase lengths: Parallel or phase conductors should follow equivalent routes and have consistent lengths and terminations to limit current imbalance.
  • Support dynamic connections correctly: A cable suitable for connecting movable parts is not automatically a continuous-reeling, drag-chain or torsion cable. Define the movement radius, frequency and restraint system before use.
  • Check grouping and enclosure heat: Enclosed ducts, bundled single cores and crowded switchboards reduce heat dissipation. Apply the current-rating and derating rules for the actual installation.

Zastosowania

  • Power wiring in railway and other track-bound vehicles
  • Electrical connections in buses and trolley buses
  • Internal connections in switchboards and distribution equipment
  • Low-voltage circuits designed for inherently short-circuit and earth-fault-proof routing
  • Protected installation in pipes, conduits and closed cable ducts
  • Equipment and movable-part connections with a defined bending duty

Kontrole przy doborze

Przed ostatecznym doborem potwierdź interfejs urządzenia, sposób ułożenia, długość trasy, warunki ruchu lub zginania, narażenia środowiskowe, wymagania dotyczące przewodników lub żył oraz dokumentację projektu.

Dane techniczne

NSGAFOEU 1.8/3kV Medium Voltage Single-Core Cable specifications

Poniżej zachowano uwagi techniczne wymienione w źródle. Przed zatwierdzeniem potwierdź ostateczny wymiar, tolerancję, założenia instalacyjne i zamówioną konfigurację.

NSGAFOEU 1.8/3kV Dimensions and Weight

The following figures are transcribed from the supplied 1.8/3 kV table. Minimum and maximum diameters help with conduit fill, gland selection, termination space, support cleats and routing clearance. Confirm final production dimensions for the selected cross-section before freezing equipment interfaces.

Data check required: the 1 x 400 mm² row in the supplied image lists a 40.0 mm minimum diameter and a 34.6 mm maximum diameter. Because a minimum cannot exceed the maximum, this row should remain unpublished as a purchasable variation until the original datasheet or factory specification confirms both values.

Tabele techniczne ze źródła

Poniższe tabele zachowują oryginalne dane produktu, w tym jednostki, zakresy i przykłady zamówień.

Typ produktuFlexible rubber-insulated single-core power cable
ModelNSGAFOEU / NSGAFÖU
Napięcie znamionowe1.8/3 kV for the dimension table shown
Higher-Voltage Version3.6/6 kV construction referenced; specification and dimensions to be confirmed separately
Liczba żył1
Zakres przekrojów znamionowych1.5-400 mm² in the supplied data
Żyła przewodzącaGiętka wielodrutowa miedź cynowana klasy 5
Norma żyły przewodzącejDIN VDE 0295 / IEC 60228
IzolacjaEPR compound type 3GI3 or 3GJ3
Inner Conductor LayerSemiconducting layer for the 3.6/6 kV version
Powłoka zewnętrznaChlorinated rubber compound type 5GM3
Stated Sheath PerformanceOil-resistant and flame-retardant
Primary InstallationProtected fixed routes and selected movable-part connections
NormaDIN VDE 0250 część 602
ModelConstruction ReferenceKey Distinction
NSGAFOEUDIN VDE 0250 część 6025GM3 chlorinated-rubber outer sheath; focus product on this page
NSHXAFOEDIN VDE 0250 część 606HM3 halogen-free outer compound with low-smoke performance stated in the supplied data
NSGAFCMOEURelated screened constructionTinned-copper wire screen; confirm complete standard and build separately
NSHXAFCMOERelated halogen-free screened constructionTinned-copper wire screen with halogen-free sheath system; confirm separately
Core x Nominal Cross-SectionMinimalna średnica zewnętrznaMaksymalna średnica zewnętrznaMasa nominalna
1 x 1.5 mm²5.7 mm7.0 mm50 kg/km
1 x 2.5 mm²6.0 mm7.5 mm60 kg/km
1 x 4 mm²6.8 mm9.0 mm80 kg/km
1 x 6 mm²7.3 mm9.5 mm100 kg/km
1 x 10 mm²8.7 mm11.0 mm160 kg/km
1 x 16 mm²10.0 mm13.0 mm230 kg/km
1 x 25 mm²12.4 mm15.0 mm340 kg/km
1 x 35 mm²13.4 mm16.5 mm430 kg/km
1 x 50 mm²14.9 mm18.0 mm580 kg/km
1 x 70 mm²16.6 mm20.5 mm780 kg/km
1 x 95 mm²19.3 mm24.0 mm1030 kg/km
1 x 120 mm²20.8 mm26.0 mm1270 kg/km
1 x 150 mm²23.0 mm28.0 mm1570 kg/km
1 x 185 mm²25.2 mm31.0 mm1900 kg/km
1 x 240 mm²28.1 mm34.5 mm2500 kg/km
1 x 300 mm²30.8 mm38.0 mm3000 kg/km
1 x 400 mm²Source conflict: 40.0 mm minimum and 34.6 mm maximum; confirm before upload4000 kg/km

Oryginalne atrybuty produktu

Te atrybuty produktu zachowano w dostarczonej postaci i należy je sprawdzić względem zamówionej konstrukcji.

Oryginalne atrybuty produktu
Typ produktuFlexible single-core rubber power cable
ModelNSGAFOEU / NSGAFÖU
Napięcie znamionowe1.8/3 kV
Higher-Voltage Version3.6/6 kV, confirm separately
Liczba żył1
Przekroje znamionowe1.5-400 mm² in supplied data
Żyła przewodzącaGiętka wielodrutowa miedź cynowana klasy 5
Norma żyły przewodzącejDIN VDE 0295 / IEC 60228
IzolacjaEPR compound type 3GI3 or 3GJ3
Inner Conductor LayerSemiconducting layer for 3.6/6 kV version
EkranNone in shown NSGAFOEU construction
Powłoka zewnętrznaChlorinated rubber type 5GM3
Stated Sheath PropertiesOil-resistant; flame-retardant
NormaDIN VDE 0250 część 602
ZastosowanieRailway vehicles, buses, switchgear, pipes and closed ducts
Normy

NSGAFOEU 1.8/3kV Medium Voltage Single-Core Cable standards and compliance

Poniższe odniesienia do norm przeniesiono z oryginalnego rekordu produktu. Wskazują podstawę źródłową i nie zastępują wymagań dotyczących certyfikacji lub kontroli dla konkretnego projektu.

  • Conductor Standard DIN VDE 0295 / IEC 60228
  • Standard DIN VDE 0250 Part 602
  • Conductor: Flexible stranded tinned-copper wires, Class 5 according to DIN VDE 0295 / IEC 60228.
  • NSGAFOEU DIN VDE 0250 Part 602 5GM3 chlorinated-rubber outer sheath; focus product on this page
  • NSHXAFOE DIN VDE 0250 Part 606 HM3 halogen-free outer compound with low-smoke performance stated in the supplied data

Jeżeli projekt wymaga raportu z badań, certyfikatu, dokumentacji oznakowania lub dopuszczenia po kontroli, uwzględnij ten wymóg w zapytaniu ofertowym.

Wycena oparta na analizie technicznej

Poproś o dobór kabla i wycenę

Prześlij wymagane funkcje, długość kabla, warunki pracy mechanicznej, środowisko, zakończenia i ilość. Nasz zespół przeanalizuje zastosowanie przed przygotowaniem wyceny.

  • Podaj nazwę produktu lub SKU oraz wymaganą długość kabla i ilość.
  • Jeśli są dostępne, dołącz specyfikację, rysunek lub kartę katalogową.

    Wysyłając ten formularz, zgadzasz się, aby TEBAOFLEX wykorzystywał podane dane kontaktowe i pliki do rozpatrzenia Twojego zapytania oraz udzielenia odpowiedzi. Pliki służą do przygotowania oferty i komunikacji technicznej związanej z zapytaniem. Zapoznaj się z dokumentem: Polityka prywatności Zawiera on aktualne informacje dotyczące przetwarzania i przechowywania danych.

    * Pola wymagane. Podaj najważniejsze informacje o kablu lub zastosowaniu do analizy.