
NSGAFOEU 1.8/3kV Medium Voltage Single-Core Cable
NSGAFOEU 1.8/3kV Medium Voltage Single-Core Cable is a TEBAOFLEX cable for the application and operating conditions identified in the original product record. These model distinctions should be preserved in the quotation, order confirmation, production marking and test documentation. A halogen-free compound or metallic screen changes the cable designation and should not be added as a generic NSGAFOEU attribute. The following figures are transcribed from the supplied 1.8/3 kV table. Send the exact size, length, installation duty and documentation requirements for a technical quotation.
NSGAFOEU 1.8/3kV Medium Voltage Single-Core Cable is a TEBAOFLEX cable for the application and operating conditions identified in the original product record. These model distinctions should be preserved in the quotation, order confirmation, production marking and test documentation. A halogen-free compound or metallic screen changes the cable designation and should not be added as a generic NSGAFOEU attribute. The following figures are transcribed from the supplied 1.8/3 kV table. Minimum and maximum diameters help with conduit fill, gland selection, termination space, support cleats and routing clearance. Confirm final production dimensions for the selected cross-section before freezing equipment interfaces. Data check required: the 1 x 400 mm² row in the supplied image lists a 40.0 mm minimum diameter and a 34.6 mm maximum diameter. Because a minimum cannot exceed the maximum, this row should remain unpublished as a purchasable variation until the original datasheet or factory specification confirms both values. NSGAFOEU is a 1.8/3 kV medium-voltage single-core cable for protected fixed wiring and selected movable connections in railway vehicles, buses, pipes, enclosed ducts and switchgear. Its Class 5 tinned-copper conductor and rubber construction combine routing flexibility with a compact, mechanically protected power connection. The source record places this product in industrial cables. Before ordering, confirm the exact product variant, conductor or core arrangement, system rating, route conditions, equipment connection and required documentation against the project specification.
NSGAFOEU 1.8/3kV Medium Voltage Single-Core Cable construction
Budowa kabla
- Żyła przewodząca: Flexible stranded tinned-copper wires, Class 5 according to DIN VDE 0295 / IEC 60228.
- Inner conductor layer: A semiconducting layer is included in the 3.6/6 kV construction. This layer is not identified as part of the 1.8/3 kV build in the supplied diagram.
- Izolacja: EPR rubber compound type 3GI3 or 3GJ3.
- Powłoka zewnętrzna: Chlorinated rubber compound type 5GM3, stated as oil-resistant and flame-retardant.
NSGAFOEU 1.8/3kV Medium Voltage Single-Core Cable applications
AC Single-Core Installation Considerations
- Keep circuit conductors together: Arrange all phases of an AC circuit in the specified trefoil or flat formation so their magnetic fields remain balanced and loop impedance is controlled.
- Avoid individual ferromagnetic entries: Do not pass each AC single-core phase separately through a closed steel gland plate or steel conduit without an approved non-magnetic arrangement. Alternating magnetic flux can cause eddy-current heating.
- Use equal phase lengths: Parallel or phase conductors should follow equivalent routes and have consistent lengths and terminations to limit current imbalance.
- Support dynamic connections correctly: A cable suitable for connecting movable parts is not automatically a continuous-reeling, drag-chain or torsion cable. Define the movement radius, frequency and restraint system before use.
- Check grouping and enclosure heat: Enclosed ducts, bundled single cores and crowded switchboards reduce heat dissipation. Apply the current-rating and derating rules for the actual installation.
Zastosowania
- Power wiring in railway and other track-bound vehicles
- Electrical connections in buses and trolley buses
- Internal connections in switchboards and distribution equipment
- Low-voltage circuits designed for inherently short-circuit and earth-fault-proof routing
- Protected installation in pipes, conduits and closed cable ducts
- Equipment and movable-part connections with a defined bending duty
Kontrole przy doborze
Przed ostatecznym doborem potwierdź interfejs urządzenia, sposób ułożenia, długość trasy, warunki ruchu lub zginania, narażenia środowiskowe, wymagania dotyczące przewodników lub żył oraz dokumentację projektu.
NSGAFOEU 1.8/3kV Medium Voltage Single-Core Cable specifications
Poniżej zachowano uwagi techniczne wymienione w źródle. Przed zatwierdzeniem potwierdź ostateczny wymiar, tolerancję, założenia instalacyjne i zamówioną konfigurację.
NSGAFOEU 1.8/3kV Dimensions and Weight
The following figures are transcribed from the supplied 1.8/3 kV table. Minimum and maximum diameters help with conduit fill, gland selection, termination space, support cleats and routing clearance. Confirm final production dimensions for the selected cross-section before freezing equipment interfaces.
Data check required: the 1 x 400 mm² row in the supplied image lists a 40.0 mm minimum diameter and a 34.6 mm maximum diameter. Because a minimum cannot exceed the maximum, this row should remain unpublished as a purchasable variation until the original datasheet or factory specification confirms both values.
Tabele techniczne ze źródła
Poniższe tabele zachowują oryginalne dane produktu, w tym jednostki, zakresy i przykłady zamówień.
| Typ produktu | Flexible rubber-insulated single-core power cable |
| Model | NSGAFOEU / NSGAFÖU |
| Napięcie znamionowe | 1.8/3 kV for the dimension table shown |
| Higher-Voltage Version | 3.6/6 kV construction referenced; specification and dimensions to be confirmed separately |
| Liczba żył | 1 |
| Zakres przekrojów znamionowych | 1.5-400 mm² in the supplied data |
| Żyła przewodząca | Giętka wielodrutowa miedź cynowana klasy 5 |
| Norma żyły przewodzącej | DIN VDE 0295 / IEC 60228 |
| Izolacja | EPR compound type 3GI3 or 3GJ3 |
| Inner Conductor Layer | Semiconducting layer for the 3.6/6 kV version |
| Powłoka zewnętrzna | Chlorinated rubber compound type 5GM3 |
| Stated Sheath Performance | Oil-resistant and flame-retardant |
| Primary Installation | Protected fixed routes and selected movable-part connections |
| Norma | DIN VDE 0250 część 602 |
| Model | Construction Reference | Key Distinction |
|---|---|---|
| NSGAFOEU | DIN VDE 0250 część 602 | 5GM3 chlorinated-rubber outer sheath; focus product on this page |
| NSHXAFOE | DIN VDE 0250 część 606 | HM3 halogen-free outer compound with low-smoke performance stated in the supplied data |
| NSGAFCMOEU | Related screened construction | Tinned-copper wire screen; confirm complete standard and build separately |
| NSHXAFCMOE | Related halogen-free screened construction | Tinned-copper wire screen with halogen-free sheath system; confirm separately |
| Core x Nominal Cross-Section | Minimalna średnica zewnętrzna | Maksymalna średnica zewnętrzna | Masa nominalna |
|---|---|---|---|
| 1 x 1.5 mm² | 5.7 mm | 7.0 mm | 50 kg/km |
| 1 x 2.5 mm² | 6.0 mm | 7.5 mm | 60 kg/km |
| 1 x 4 mm² | 6.8 mm | 9.0 mm | 80 kg/km |
| 1 x 6 mm² | 7.3 mm | 9.5 mm | 100 kg/km |
| 1 x 10 mm² | 8.7 mm | 11.0 mm | 160 kg/km |
| 1 x 16 mm² | 10.0 mm | 13.0 mm | 230 kg/km |
| 1 x 25 mm² | 12.4 mm | 15.0 mm | 340 kg/km |
| 1 x 35 mm² | 13.4 mm | 16.5 mm | 430 kg/km |
| 1 x 50 mm² | 14.9 mm | 18.0 mm | 580 kg/km |
| 1 x 70 mm² | 16.6 mm | 20.5 mm | 780 kg/km |
| 1 x 95 mm² | 19.3 mm | 24.0 mm | 1030 kg/km |
| 1 x 120 mm² | 20.8 mm | 26.0 mm | 1270 kg/km |
| 1 x 150 mm² | 23.0 mm | 28.0 mm | 1570 kg/km |
| 1 x 185 mm² | 25.2 mm | 31.0 mm | 1900 kg/km |
| 1 x 240 mm² | 28.1 mm | 34.5 mm | 2500 kg/km |
| 1 x 300 mm² | 30.8 mm | 38.0 mm | 3000 kg/km |
| 1 x 400 mm² | Source conflict: 40.0 mm minimum and 34.6 mm maximum; confirm before upload | 4000 kg/km | |
Oryginalne atrybuty produktu
Te atrybuty produktu zachowano w dostarczonej postaci i należy je sprawdzić względem zamówionej konstrukcji.
| Typ produktu | Flexible single-core rubber power cable |
|---|---|
| Model | NSGAFOEU / NSGAFÖU |
| Napięcie znamionowe | 1.8/3 kV |
| Higher-Voltage Version | 3.6/6 kV, confirm separately |
| Liczba żył | 1 |
| Przekroje znamionowe | 1.5-400 mm² in supplied data |
| Żyła przewodząca | Giętka wielodrutowa miedź cynowana klasy 5 |
| Norma żyły przewodzącej | DIN VDE 0295 / IEC 60228 |
| Izolacja | EPR compound type 3GI3 or 3GJ3 |
| Inner Conductor Layer | Semiconducting layer for 3.6/6 kV version |
| Ekran | None in shown NSGAFOEU construction |
| Powłoka zewnętrzna | Chlorinated rubber type 5GM3 |
| Stated Sheath Properties | Oil-resistant; flame-retardant |
| Norma | DIN VDE 0250 część 602 |
| Zastosowanie | Railway vehicles, buses, switchgear, pipes and closed ducts |
NSGAFOEU 1.8/3kV Medium Voltage Single-Core Cable standards and compliance
Poniższe odniesienia do norm przeniesiono z oryginalnego rekordu produktu. Wskazują podstawę źródłową i nie zastępują wymagań dotyczących certyfikacji lub kontroli dla konkretnego projektu.
- Conductor Standard DIN VDE 0295 / IEC 60228
- Standard DIN VDE 0250 Part 602
- Conductor: Flexible stranded tinned-copper wires, Class 5 according to DIN VDE 0295 / IEC 60228.
- NSGAFOEU DIN VDE 0250 Part 602 5GM3 chlorinated-rubber outer sheath; focus product on this page
- NSHXAFOE DIN VDE 0250 Part 606 HM3 halogen-free outer compound with low-smoke performance stated in the supplied data
Jeżeli projekt wymaga raportu z badań, certyfikatu, dokumentacji oznakowania lub dopuszczenia po kontroli, uwzględnij ten wymóg w zapytaniu ofertowym.
Poproś o dobór kabla i wycenę
Prześlij wymagane funkcje, długość kabla, warunki pracy mechanicznej, środowisko, zakończenia i ilość. Nasz zespół przeanalizuje zastosowanie przed przygotowaniem wyceny.
- Podaj nazwę produktu lub SKU oraz wymaganą długość kabla i ilość.
- Jeśli są dostępne, dołącz specyfikację, rysunek lub kartę katalogową.

