Type 70 / Type 71 BS 6708 320/550 V Armoured Mining Cable
Type 70 / Type 71 mining cable for excavating and crushing machines, equipment and coalface lighting, with the source-defined 320/550 V rating and 1.5 kV test reference.
- Model: Type 70 / Type 71
- Conductor and insulation: flexible tinned copper with the insulation and core construction listed for this model in the supplied PDF
- Screen, pilot, earth and armour arrangement preserved from the source datasheet
- Heavy-duty chloroprene or PCP outer protection as listed for this model
- Original Type datasheet available as the product download
Send the equipment, voltage, conductor area, route, quantity and document requirements for an RFQ.
Type 70 / Type 71 for excavating and crushing machines, equipment and coalface lighting
Type 70 / Type 71 mining cable is specified in the supplied BS 6708 datasheet for excavating and crushing machines, equipment and coalface lighting. This page keeps the source-listed voltage, test reference, core functions and dimensional tables together so a procurement engineer can compare the requested model against the cable marking and the equipment connection. The editorial focus is the lower-voltage armoured supply and lighting route, not a generic promise of performance.
The supplied construction uses four or five unscreened cores laid in contact, with rubber bedding, galvanized steel pliable armour and a heavy-duty chloroprene outer sheath. That arrangement matters because Type 70 and Type 71 are the 320/550 V four- and five-core options; the PDF does not describe individual core screens. The family should therefore be selected by model, core function and installation route as well as by voltage. The Ассортимент кабелей для горнодобывающей и туннельной промышленности provides the wider TEBAOFLEX product context.
- Выберите по: confirm whether the auxiliary circuit needs the four-core Type 70 or five-core Type 71 arrangement and retain the 320/550 V rating.
- Подтвердите перед заказом: existing sheath marking, conductor area, cable length, route, support or handling system, terminations and the required inspection documents.
- Do not infer: values not listed in the supplied PDF, such as a different current basis, water/oil/UV performance, certification scope or mechanical interchangeability.
Используйте Mining & Tunnelling solutions page to frame the lower-voltage armoured cable choice around the machine connection and route, not the model number alone.
For a technical quotation, send the equipment nameplate or existing cable marking, voltage and size requirement, installation conditions, quantity, destination and any project-specific test or documentation requirement.
Type 70 / Type 71 construction
The cross-section below is the supplied construction drawing for Type 70 / Type 71. The ordering decision is driven by Type 70 and Type 71 are the 320/550 V four- and five-core options; the PDF does not describe individual core screens.

Source-listed construction
| Элемент конструкции | Значение по исходным данным |
|---|---|
| Дирижер | Electrolytic stranded tinned copper wire, IEC 60228 Class 5 |
| Изоляция | Изоляция из ЭПР |
| бросок | Four or five unscreened cores laid up in contact with each other |
| Доспехи | Гибкая броня из оцинкованной стали |
| Ножны | Heavy-duty chloroprene outer sheath |
| Variants | Type 70 four-core; Type 71 five-core |
Do not use the drawing as a substitute for the dimensional tables. Confirm the cable end preparation, screen and earth termination, armour bonding and machine interface with the equipment documentation before installation.
Type 70 / Type 71 applications

The supplied datasheet identifies this cable for excavating and crushing machines, equipment and coalface lighting. Google result patterns for the BS 6708 family also separate cables by equipment duty, voltage class, core function and whether the route is armoured, screened, flat or auxiliary. That is why this page keeps the Type 70 / Type 71 construction separate from nearby Type numbers.
- Primary duty: excavating and crushing machines, equipment and coalface lighting.
- Model boundary: Type 70 and Type 71 are the 320/550 V four- and five-core options; the PDF does not describe individual core screens.
- Project check: match the cable marking, core map, voltage, termination, route geometry and handling method to the machine drawing.
- Environmental review: confirm the actual mine/quarry conditions and any authority, inspection or documentation requirements; do not infer a certification or material-resistance claim from the model number.
Where the project calls for the higher 640/1100 V armoured family, compare the Type 20/21 mining cable, paying attention to its three-core/four-core distinction.
The cable should be released only after the equipment route, required length, conductor area, core functions and connection details are agreed. If the intended duty is different from the source-listed application, request an engineering review through the quotation process.
Type 70 / Type 71 specifications
The summary below identifies the supplied model family. The source-transcribed tables that follow retain the PDF's dimensional, electrical and construction values, including available sizes, resistance, current, diameter, mass, bending or pulling data when the PDF provides them.
| Selection item | Source-linked value |
|---|---|
| Модель | Type 70 / Type 71 |
| Номинальное напряжение | 320/550 V |
| Испытательное напряжение | 1.5 kV |
| Приложение | excavating and crushing machines, equipment and coalface lighting |
| Стандарт изделия | BS 6708 |
Complete source-transcribed technical tables
Source PDF: BS6708_TYPE_70_TYPE_71_320_550V_ARMOURED_CABLE_datasheet.pdf; 2 pages; 5 extracted tables. Values are not recalculated or replaced by third-party values.
| Параметр | Ценить |
|---|---|
| Дирижер | Electrolytic stranded tinned copper wire, IEC 60228 Class 5 |
| Изоляция | Изоляция из ЭПР |
| бросок | Four or five unscreened cores laid up in contact with each other |
| Постельные принадлежности | Rubber based bedding compound |
| Доспехи | Гибкая броня из оцинкованной стали |
| Внешняя оболочка | Heavy duty chloroprene outer sheath |
| Параметр | Ценить |
|---|---|
| Стандарт | BS 6708 |
| Номинальное напряжение | 320/550 V |
| Испытательное напряжение | 1.5 kV |
| Type 70 | Four-core unscreened power supply cable with pliable armour between inner and outer sheaths |
| Type 71 | Five-core unscreened power supply cable with pliable armour between inner and outer sheaths |
| CORE DIMENSIONS | ||||
|---|---|---|---|---|
| Тип | Nominal cross section | Stranding mm | Cond. dia. mm | Insul. thick. mm |
| Type 70 | 4x4 | 56/0.30 | 2.60 | 1.0 |
| Type 71 | 5x4 | 56/0.30 | 2.60 | 1.0 |
| CABLE DIMENSIONS | ||||||||
|---|---|---|---|---|---|---|---|---|
| Тип | Nominal cross section | Inner sheath radial thick. mm | Min. inner sheath dia. mm | Max. inner sheath dia. mm | Armour size mm | Outer sheath thick. mm | Min. OD mm | Max. OD mm |
| Type 70 | 4x4 | 2.0 | 15.8 | 17.8 | 7/0.45 | 2.5 | 23.5 | 26.0 |
| Type 71 | 5x4 | 2.0 | 17.2 | 19.2 | 7/0.45 | 2.5 | 24.9 | 27.4 |
| MECHANICAL AND ELECTRICAL DETAILS | |||||||
|---|---|---|---|---|---|---|---|
| Тип | Min. bend radius mm | Max pulling tension kgf | Approx. weight kg/km | Copper weight kg/km | Current rating at 25 deg C | Phase cond. DC res. ohm/km | Armour DC res. ohm/km |
| Type 70 | 234 | 96 | 1100 | 154 | 28 | 5.09 | 5.07 |
| Type 71 | 247 | 100 | 1230 | 192 | 28 | 5.09 | 4.63 |
Use the table values with the equipment drawing and approved termination plan. If the requested conductor area, current basis, mechanical limit or environmental condition is not listed in the supplied PDF, treat it as a quotation-stage confirmation item.
Type 70 / Type 71 standards and references
| Параметр | Source-linked reference |
|---|---|
| Стандарт изделия | BS 6708 |
| Номинальное напряжение | 320/550 V |
| Испытательное напряжение | 1.5 kV |
| Source application | excavating and crushing machines, equipment and coalface lighting |
The product page preserves the BS 6708 reference appearing in the supplied PDF. The BSI record currently identifies BS 6708:1998 as withdrawn on 22 May 2026; this status note is a standards-reference update, not a claim that the product is currently certified or approved. See the official BSI BS 6708 scope record for the published status.
For an RFQ, state the required standard documents, inspection scope, test report, cable marking, destination rules and any replacement-equivalence requirement. The model number alone does not establish legal installation compliance.
Варианты кабелей по теме
Сравните эти варианты кабелей по сочетанию услуг, типу перемещения, нагрузке, напряжению и требованиям к передаче.
Бронированный экранированный силовой кабель для горнодобывающей промышленности TYPE260
Аналогичный кабель предназначен для других областей применения или режимов работы.
Посмотреть товарПодземный угольный шахтный кабель типа 240, напряжение от 1,1 кВ до 11 кВ.
Аналогичный кабель предназначен для других областей применения или режимов работы.
Посмотреть товарГорнодобывающий кабель типа 241.1 1,1 кВ | Семейство типов 241
Аналогичный кабель предназначен для других областей применения или режимов работы.
Посмотреть товарЗапросите рекомендации по выбору кабеля и коммерческое предложение.
Укажите необходимые услуги, длину кабеля, механические характеристики, условия эксплуатации, тип разъемов и количество. Наша команда рассмотрит заявку перед составлением коммерческого предложения.
- Укажите название продукта или артикул, а также необходимую длину кабеля и количество.
- При наличии приложите техническое задание, чертеж или спецификацию.