NSGAFOEU 1.8/3kV Medium Voltage Single-Core Cable
NSGAFOEU 1.8/3kV Medium Voltage Single-Core Cable is a TEBAOFLEX cable for the application and operating conditions identified in the original product record. These model distinctions should be preserved in the quotation, order confirmation, production marking and test documentation. A halogen-free compound or metallic screen changes the cable designation and should not be added as a generic NSGAFOEU attribute. The following figures are transcribed from the supplied 1.8/3 kV table. Send the exact size, length, installation duty and documentation requirements for a technical quotation.
NSGAFOEU 1.8/3kV Medium Voltage Single-Core Cable is a TEBAOFLEX cable for the application and operating conditions identified in the original product record. These model distinctions should be preserved in the quotation, order confirmation, production marking and test documentation. A halogen-free compound or metallic screen changes the cable designation and should not be added as a generic NSGAFOEU attribute. The following figures are transcribed from the supplied 1.8/3 kV table. Minimum and maximum diameters help with conduit fill, gland selection, termination space, support cleats and routing clearance. Confirm final production dimensions for the selected cross-section before freezing equipment interfaces. Data check required: the 1 x 400 mm² row in the supplied image lists a 40.0 mm minimum diameter and a 34.6 mm maximum diameter. Because a minimum cannot exceed the maximum, this row should remain unpublished as a purchasable variation until the original datasheet or factory specification confirms both values. NSGAFOEU is a 1.8/3 kV medium-voltage single-core cable for protected fixed wiring and selected movable connections in railway vehicles, buses, pipes, enclosed ducts and switchgear. Its Class 5 tinned-copper conductor and rubber construction combine routing flexibility with a compact, mechanically protected power connection. The source record places this product in industrial cables. Before ordering, confirm the exact product variant, conductor or core arrangement, system rating, route conditions, equipment connection and required documentation against the project specification.
NSGAFOEU 1.8/3kV Medium Voltage Single-Core Cable construction
Kablo yapısı
- İletken: Flexible stranded tinned-copper wires, Class 5 according to DIN VDE 0295 / IEC 60228.
- Inner conductor layer: A semiconducting layer is included in the 3.6/6 kV construction. This layer is not identified as part of the 1.8/3 kV build in the supplied diagram.
- Yalıtım: EPR rubber compound type 3GI3 or 3GJ3.
- Dış kılıf: Chlorinated rubber compound type 5GM3, stated as oil-resistant and flame-retardant.
NSGAFOEU 1.8/3kV Medium Voltage Single-Core Cable applications
AC Single-Core Installation Considerations
- Keep circuit conductors together: Arrange all phases of an AC circuit in the specified trefoil or flat formation so their magnetic fields remain balanced and loop impedance is controlled.
- Avoid individual ferromagnetic entries: Do not pass each AC single-core phase separately through a closed steel gland plate or steel conduit without an approved non-magnetic arrangement. Alternating magnetic flux can cause eddy-current heating.
- Use equal phase lengths: Parallel or phase conductors should follow equivalent routes and have consistent lengths and terminations to limit current imbalance.
- Support dynamic connections correctly: A cable suitable for connecting movable parts is not automatically a continuous-reeling, drag-chain or torsion cable. Define the movement radius, frequency and restraint system before use.
- Check grouping and enclosure heat: Enclosed ducts, bundled single cores and crowded switchboards reduce heat dissipation. Apply the current-rating and derating rules for the actual installation.
Uygulamalar
- Power wiring in railway and other track-bound vehicles
- Electrical connections in buses and trolley buses
- Internal connections in switchboards and distribution equipment
- Low-voltage circuits designed for inherently short-circuit and earth-fault-proof routing
- Protected installation in pipes, conduits and closed cable ducts
- Equipment and movable-part connections with a defined bending duty
Seçim kontrolleri
Nihai seçimden önce ekipman arayüzünü, döşeme yöntemini, güzergâh uzunluğunu, hareket veya bükülme koşullarını, çevresel etkileri, iletken veya damar gereksinimlerini ve proje belgelerini teyit edin.
NSGAFOEU 1.8/3kV Medium Voltage Single-Core Cable specifications
Kaynakta listelenen teknik notlar aşağıda korunmuştur. Onaylamadan önce nihai kesiti, toleransı, döşeme esaslarını ve sipariş edilen yapılandırmayı teyit edin.
NSGAFOEU 1.8/3kV Dimensions and Weight
The following figures are transcribed from the supplied 1.8/3 kV table. Minimum and maximum diameters help with conduit fill, gland selection, termination space, support cleats and routing clearance. Confirm final production dimensions for the selected cross-section before freezing equipment interfaces.
Data check required: the 1 x 400 mm² row in the supplied image lists a 40.0 mm minimum diameter and a 34.6 mm maximum diameter. Because a minimum cannot exceed the maximum, this row should remain unpublished as a purchasable variation until the original datasheet or factory specification confirms both values.
Kaynakta listelenen teknik tablolar
Aşağıdaki tablolar birimler, aralıklar ve sipariş örnekleri dâhil orijinal ürün verilerini korur.
| Ürün Türü | Flexible rubber-insulated single-core power cable |
| Model | NSGAFOEU / NSGAFÖU |
| Anma gerilimi | 1.8/3 kV for the dimension table shown |
| Higher-Voltage Version | 3.6/6 kV construction referenced; specification and dimensions to be confirmed separately |
| Damar Sayısı | 1 |
| Nominal Kesit Aralığı | 1.5-400 mm² in the supplied data |
| İletken | Sınıf 5 esnek çok telli kalaylı bakır |
| İletken standardı | DIN VDE 0295 / IEC 60228 |
| Yalıtım | EPR compound type 3GI3 or 3GJ3 |
| Inner Conductor Layer | Semiconducting layer for the 3.6/6 kV version |
| Dış Kılıf | Chlorinated rubber compound type 5GM3 |
| Stated Sheath Performance | Oil-resistant and flame-retardant |
| Primary Installation | Protected fixed routes and selected movable-part connections |
| Standart | DIN VDE 0250 Bölüm 602 |
| Model | Construction Reference | Key Distinction |
|---|---|---|
| NSGAFOEU | DIN VDE 0250 Bölüm 602 | 5GM3 chlorinated-rubber outer sheath; focus product on this page |
| NSHXAFOE | DIN VDE 0250 Bölüm 606 | HM3 halogen-free outer compound with low-smoke performance stated in the supplied data |
| NSGAFCMOEU | Related screened construction | Tinned-copper wire screen; confirm complete standard and build separately |
| NSHXAFCMOE | Related halogen-free screened construction | Tinned-copper wire screen with halogen-free sheath system; confirm separately |
| Core x Nominal Cross-Section | Minimum Dış Çap | Maksimum Dış Çap | Nominal Ağırlık |
|---|---|---|---|
| 1 x 1.5 mm² | 5.7 mm | 7.0 mm | 50 kg/km |
| 1 x 2.5 mm² | 6.0 mm | 7.5 mm | 60 kg/km |
| 1 x 4 mm² | 6.8 mm | 9.0 mm | 80 kg/km |
| 1 x 6 mm² | 7.3 mm | 9.5 mm | 100 kg/km |
| 1 x 10 mm² | 8.7 mm | 11.0 mm | 160 kg/km |
| 1 x 16 mm² | 10.0 mm | 13.0 mm | 230 kg/km |
| 1 x 25 mm² | 12.4 mm | 15.0 mm | 340 kg/km |
| 1 x 35 mm² | 13.4 mm | 16.5 mm | 430 kg/km |
| 1 x 50 mm² | 14.9 mm | 18.0 mm | 580 kg/km |
| 1 x 70 mm² | 16.6 mm | 20.5 mm | 780 kg/km |
| 1 x 95 mm² | 19.3 mm | 24.0 mm | 1030 kg/km |
| 1 x 120 mm² | 20.8 mm | 26.0 mm | 1270 kg/km |
| 1 x 150 mm² | 23.0 mm | 28.0 mm | 1570 kg/km |
| 1 x 185 mm² | 25.2 mm | 31.0 mm | 1900 kg/km |
| 1 x 240 mm² | 28.1 mm | 34.5 mm | 2500 kg/km |
| 1 x 300 mm² | 30.8 mm | 38.0 mm | 3000 kg/km |
| 1 x 400 mm² | Source conflict: 40.0 mm minimum and 34.6 mm maximum; confirm before upload | 4000 kg/km | |
Orijinal ürün nitelikleri
Bu ürün nitelikleri sunulduğu şekilde korunmuştur ve sipariş edilen yapıyla karşılaştırılarak kontrol edilmelidir.
| Ürün Türü | Flexible single-core rubber power cable |
|---|---|
| Model | NSGAFOEU / NSGAFÖU |
| Anma Gerilimi | 1.8/3 kV |
| Higher-Voltage Version | 3.6/6 kV, confirm separately |
| Damar Sayısı | 1 |
| Nominal Kesitler | 1.5-400 mm² in supplied data |
| İletken | Sınıf 5 esnek çok telli kalaylı bakır |
| İletken standardı | DIN VDE 0295 / IEC 60228 |
| Yalıtım | EPR compound type 3GI3 or 3GJ3 |
| Inner Conductor Layer | Semiconducting layer for 3.6/6 kV version |
| Ekran | None in shown NSGAFOEU construction |
| Dış Kılıf | Chlorinated rubber type 5GM3 |
| Stated Sheath Properties | Oil-resistant; flame-retardant |
| Standart | DIN VDE 0250 Bölüm 602 |
| Uygulama | Railway vehicles, buses, switchgear, pipes and closed ducts |
NSGAFOEU 1.8/3kV Medium Voltage Single-Core Cable standards and compliance
Aşağıdaki standart referansları orijinal ürün kaydından aktarılmıştır. Kaynak dayanağını belirtirler; projeye özel sertifikasyon veya muayene gereksinimlerinin yerine geçmezler.
- Conductor Standard DIN VDE 0295 / IEC 60228
- Standard DIN VDE 0250 Part 602
- Conductor: Flexible stranded tinned-copper wires, Class 5 according to DIN VDE 0295 / IEC 60228.
- NSGAFOEU DIN VDE 0250 Part 602 5GM3 chlorinated-rubber outer sheath; focus product on this page
- NSHXAFOE DIN VDE 0250 Part 606 HM3 halogen-free outer compound with low-smoke performance stated in the supplied data
Proje bir test raporu, sertifika, işaretleme kaydı veya muayene sonrası onay gerektiriyorsa bu gereksinimi teklif talebine ekleyin.
Kablo önerisi ve teklif isteyin
Gerekli işlevleri, kablo uzunluğunu, mekanik çalışma koşullarını, ortamı, uç bağlantısını ve miktarı bildirin. Ekibimiz teklif vermeden önce uygulamayı değerlendirecektir.
- Ürün adını veya SKU kodunu, gerekli kablo uzunluğunu ve miktarı belirtin.
- Varsa teknik şartname, çizim veya veri sayfası ekleyin.