احصل على عرض سعر
كابلات التعدين وحفر الأنفاق تيباوفليكس

Type 450 Class 1 Composite Screened Mining Cable 3.3/3.3–33/33 kV

Type 450 mining cable is a Class 1 composite screened cable for 3.3/3.3–33/33 kV reeling and trailing service.

  • Three semiconductive screened EPR power cores
  • Two earth conductors and one elastomer-covered pilot
  • Composite tinned-copper/polyester-yarn screen
  • Extra-heavy XHD-85-PCP sheath with polyaramid braid
  • Draglines, shovels, excavators, wharf cranes and materials handling
  • 33/33 kV available on request; +90 °C operating temperature

Send the voltage, area, route and reel arrangement for technical review.

معلومات المنتج
ماركة
تيباوفليكس
نظرة عامة على المنتج

Type 450 mining cable for reeling and trailing equipment

Type 450 mining cable is the composite-screened Class 1 option in the supplied high-voltage surface-mining group. The datasheet covers 3.3/3.3, 6.6/6.6, 11/11 and 22/22 kV, with 33/33 kV available on request. It is organized for general-purpose reeling and trailing on draglines, shovels, excavators, wharf cranes and materials-handling equipment.

Three semiconductive screened EPR power cores are paired with two elastomer-covered tinned earth conductors and one elastomer-covered tinned pilot. The composite screen uses tinned annealed copper and polyester yarn beneath semiconductive tape, and the outer build uses an extra-heavy XHD-85-PCP sheath with polyaramid braid. Those elements make Type 450 more specific than a generic screened power cable: the complete core count and termination arrangement must be preserved.

For procurement, choose the voltage designation and conductor area first; then assess drum or guide geometry, cable entry, handling speed and connection hardware. The source does not publish a speed, bending radius or pulling limit, so those values should be requested for the actual machine route. Include the intended reel direction and access constraints in that review.

بناء

Type 450 Class 1 composite screen

Type 450 combines semiconductive screened power cores with a composite screen and a defined two-earth/one-pilot interstitial arrangement. The 33/33 kV option is identified in the source as available on request rather than as a standard table series.

Type 450 cable cross-section showing power cores, composite screen, two earths and pilot
Supplied Type 450 cross-section showing the Class 1 composite screened core arrangement.
Construction identified in the supplied datasheet
المعلمةالقيمة المدرجة في المصدر
نوى الطاقةThree tinned copper cores with XR-EP-90 semiconductive screened insulation
شاشة مركبةTinned annealed copper and polyester yarn under semiconductive tape
موصلات التأريضTwo elastomer-covered tinned earth conductors
PilotOne elastomer-covered tinned pilot
تعريفRed, white and blue braid tracers
غمدExtra-heavy XHD-85-PCP with polyaramid braid

The core count and composite screen are shown in the supplied cross-section. Confirm them with the termination schedule and do not select solely by voltage or outer diameter.

التطبيقات

Type 450 reeling and trailing applications

Type 450 is suited to the project conversations that start with a reel, dragline or mobile materials-handling route. The source names the equipment categories; the final cable decision still depends on the complete handling system.

  • Draglines, shovels and excavators
  • Wharf cranes and materials-handling equipment
  • General-purpose reeling or slow trailing routes
  • 33/33 kV enquiries should identify the requested size and documentation because the source marks this voltage as available on request

Confirm the route, reel/guide arrangement, terminations and mechanical duty. No current, bend-radius, pulling-load or UV rating is added beyond the source data.

تحديد

Type 450 Class 1 Composite Screened Mining Cable 3.3/3.3–33/33 kV technical data

The dimensional and electrical values below are transcribed from the supplied PDF for Type 450 mining cable. The tables are retained by voltage, screen option or construction section as presented in the source. Source ordering codes are included where present in the extracted table; blank source cells are not assigned new values.

Use the relevant area, conductor dimensions, insulation or covering thickness, nominal diameter and mass together. The source does not create a universal current-capacity, bend-radius, pulling-load or travel-speed value for this product.

TYPE 450.3 - 3.3 kV - ELECTRICAL DATA

TYPE 450.3 - 3.3 kV - ELECTRICAL DATA
جزءArea mm2Nom. dia. mmInsul. thick. mmAC res. oh/kmReact. oh/kmVolt drop mV/A.mCap. uF/km
25-450-3257.22.20.9510.1181.660.395
35-450-3358.42.20.6980.1131.220.437
50-450-3509.72.40.5230.1090.9250.450
70-450-37012.02.40.3460.1030.6250.525
95-450-39513.32.40.2710.09860.5000.563
120-450-312015.32.40.2100.09470.3990.628
150-450-315017.22.40.1660.09180.3290.687
185-450-318518.82.40.1370.08960.2840.741
240-450-324021.72.40.1070.08670.2390.833
300-450-330024.32.40.08510.08440.2080.917

TYPE 450.3 - 3.3 kV - SCREEN, EARTH, PILOT AND MASS

TYPE 450.3 - 3.3 kV - SCREEN, EARTH, PILOT AND MASS
جزءScreen area mm2/phaseEarth and pilot area each mm2Sheath thick. mmNom. dia. mmApprox mass kg/100m
25-450-37.984.846.7355
35-450-38.585.149.7415
50-450-39.3125.654.5515
70-450-314186.060.5660
95-450-315256.363.9765
120-450-316316.468.4900
150-450-31739.56.672.81070
185-450-318506.776.51225
240-450-325606.983.31485
300-450-327807.089.01800

TYPE 450.6 - 6.6 kV - ELECTRICAL DATA

TYPE 450.6 - 6.6 kV - ELECTRICAL DATA
جزءArea mm2Nom. dia. mmInsul. thick. mmAC res. oh/kmReact. oh/kmVolt drop mV/A.mCap. uF/km
25-450-6257.23.00.9510.1241.660.309
35-450-6358.43.00.6980.1181.230.340
50-450-6509.73.00.5230.1130.9270.375
70-450-67012.03.00.3460.1060.6270.435
95-450-69513.33.00.2710.1020.5020.465
120-450-612015.33.00.2100.09790.4010.518
150-450-615017.23.00.1660.09480.3310.566
185-450-618518.83.00.1370.09230.2860.608
240-450-624021.73.00.1060.08930.2400.682
300-450-630024.33.00.08500.08710.2110.754

TYPE 450.6 - 6.6 kV - SCREEN, EARTH, PILOT AND MASS

TYPE 450.6 - 6.6 kV - SCREEN, EARTH, PILOT AND MASS
جزءScreen area mm2/phaseEarth and pilot area each mm2Sheath thick. mmNom. dia. mmApprox mass kg/100m
25-450-68.885.251.1410
35-450-69.385.554.2470
50-450-610125.957.8560
70-450-615186.363.9710
95-450-616256.466.8810
120-450-617316.571.4950
150-450-61839.56.675.51120
185-450-620506.879.31280
240-450-627607.086.21545
300-450-629807.192.31875

TYPE 450.11 - 11 kV - ELECTRICAL DATA

TYPE 450.11 - 11 kV - ELECTRICAL DATA
جزءArea mm2Nom. dia. mmInsul. thick. mmAC res. oh/kmReact. oh/kmVolt drop mV/A.mCap. uF/km
25-450-11257.25.00.9510.1361.660.217
35-450-11358.45.00.6980.1291.230.236
50-450-11509.75.00.5230.1230.9310.258
70-450-117012.05.00.3460.1150.6320.296
95-450-119513.35.00.2710.1110.5070.317
120-450-1112015.35.00.2100.1070.4080.350
150-450-1115017.25.00.1660.1030.3380.381
185-450-1118518.85.00.1370.1000.2940.407
240-450-1124021.75.00.1060.09640.2480.453
300-450-1130024.35.00.08460.09370.2190.499

TYPE 450.11 - 11 kV - SCREEN, EARTH, PILOT AND MASS

TYPE 450.11 - 11 kV - SCREEN, EARTH, PILOT AND MASS
جزءScreen area mm2/phaseEarth and pilot area each mm2Sheath thick. mmNom. dia. mmApprox mass kg/100m
25-450-111486.362.3565
35-450-111586.465.0625
50-450-1116126.568.1715
70-450-1117186.673.1855
95-450-1118256.776.1965
120-450-1120316.980.71115
150-450-112639.57.085.21315
185-450-1127507.189.01485
240-450-1130607.395.51745
300-450-1132807.41012080

TYPE 450.22 - 22 kV - ELECTRICAL DATA

TYPE 450.22 - 22 kV - ELECTRICAL DATA
جزءArea mm2Nom. dia. mmInsul. thick. mmAC res. oh/kmReact. oh/kmVolt drop mV/A.mCap. uF/km
35-450-22358.47.60.6980.1421.230.178
50-450-22509.77.60.5230.1350.9360.194
70-450-227012.07.60.3460.1270.6380.219
95-450-229513.37.60.2710.1220.5150.234
120-450-2212015.37.60.2100.1170.4160.256
150-450-2215017.27.60.1650.1130.3460.276
185-450-2218518.87.60.1360.1100.3030.294
240-450-2224021.77.60.1060.1050.2580.325

TYPE 450.22 - 22 kV - SCREEN, EARTH, PILOT AND MASS

TYPE 450.22 - 22 kV - SCREEN, EARTH, PILOT AND MASS
جزءScreen area mm2/phaseEarth and pilot area each mm2Sheath thick. mmNom. dia. mmApprox mass kg/100m
35-450-221986.877.2835
50-450-2220126.980.2930
70-450-2227187.085.61105
95-450-2227257.288.91230
120-450-2229317.393.41395
150-450-223139.57.497.51580
185-450-2232507.51011760
240-450-2234607.71082035

8 technical tables were transcribed from the supplied datasheet; confirm final selection against the original PDF and project cable schedule.

المعايير

Type 450 high-voltage reference

This page follows the supplied Type 450 Class 1 datasheet and keeps its 33/33 kV request status visible for procurement clarity.

Source-listed standard and service limits
المعلمةالقيمة المدرجة في المصدر
معيار المنتجAS/NZS 2802
Voltage range3.3/3.3 kV to 33/33 kV; 33/33 kV available on request
أقصى درجة حرارة تشغيل مستمرة+90 °C
Minimum installation temperature−25 °C
تثبيتFree air for mobile equipment; reeling/trailing
Oil / water performanceExcellent immersion performance and very good flexibility
أداء اللهبC1

State whether the request is for a standard table voltage or the 33/33 kV option, together with the area, length and machine route.

قارن حسب الرسوم

خيارات الكابلات ذات الصلة

قارن بين خيارات الكابلات هذه حسب مجموعة الخدمات، والحركة، والحمل، والجهد، ومتطلبات الإرسال.

عرض أسعار قائم على الهندسة

اطلب توصية بشأن الكابلات وعرض سعر

يرجى إرسال الخدمات المطلوبة، وطول الكابل، والقدرات الميكانيكية، والبيئة، ونوع التوصيلات، والكمية. سيقوم فريقنا بمراجعة الطلب قبل تقديم عرض السعر.

  • يرجى تضمين اسم المنتج أو رمز المنتج (SKU) بالإضافة إلى طول الكابل المطلوب وكميته.
  • أرفق المواصفات أو الرسم أو ورقة البيانات عند توفرها.

    اختياري: إرفاق مواصفات الكابل أو الرسم أو ورقة البيانات أو صورة المنتج (PDF، DOC، DOCX، XLS، XLSX، CSV، JPG أو PNG؛ بحد أقصى 10 ميجابايت).

    بإرسال هذا النموذج، فإنك توافق على أن تستخدم شركة TEBAOFLEX معلومات الاتصال والملفات المُقدمة لمراجعة استفسارك والرد عليه. تُستخدم الملفات لإعداد عروض الأسعار والتواصل الهندسي المتعلق بطلبك. راجع سياسة ملفاتنا سياسة الخصوصية للحصول على معلومات حديثة حول معالجة البيانات والاحتفاظ بها.

    * الحقول المطلوبة. يرجى تضمين تفاصيل الكابل الرئيسي أو التطبيق للمراجعة.