Hafen- und Schleppkabelleitungen TEBAOFLEX

NTSFLCGEWOEU flache Mittelspannungs-Trommelleitung

NTSFLCGEWOEU flache Mittelspannungs-Trommelleitung ist für kontinuierliche Biegung in einer Ebene auf monospiralen Trommeln ausgelegt. Die Spannungsklassen reichen von 3.6/6 kV bis 8.7/15 kV; WGF-D-Ausführungen stehen für kombinierte Energie- und Lichtwellenleiterübertragung zur Verfügung.

Produktinformationen
SKU
TF-NTSFLCGEWOEU
Marke
TEBAOFLEX
Produktübersicht

Built around one-plane travel

The NTSFLCGEWOEU flat profile is designed for moving medium-voltage power supplies on monospiral reels and aligned guide systems. Its width and height matter as much as conductor size when matching the cable to your equipment.

Compare the 3.6/6 kV and 6/10 kV constructions below. The wider voltage family also includes 8.7/15 kV; its dimensions require a separate review. Optional WGF-D configurations combine power with fibre-optic transmission.

Start with the complete cable route. Send reel geometry, cable length, movement and operating conditions. We can review the construction before preparing a quotation.

Aufbau

Aufbau

A flexible copper and rubber-insulation system, arranged in a flat profile for controlled movement.

NTSFLCGEWOEU construction
SchichtAufbaudetail
LeiterFlexible Class 5 copper power cores.
Field controlSemiconductive conductor and insulation screens.
IsolierungEPR-based medium-voltage rubber.
AußenmantelAbrasion-resistant rubber compound.
Fibre optionOptical elements in WGF-D configurations.

Specify the earth arrangement, fibre type and fibre count for the construction you need.

NTSFLCGEWOEU 3D product video thumbnail
3D product presentation. The power and fibre configuration shown is one option; confirm the construction for your enquiry.

Watch on YouTube ↗

Anwendungen

Check your application

Match the movement first. Then confirm the electrical duty and the available reel space.

Illustrative stacker-reclaimer application in a bulk-material-handling yard
Stacker-reclaimer application
Anwendungsillustration
Illustrative monospiral reel, aligned guide and flat cable route
Controlled one-plane routing
Conceptual routing illustration
Kabeltrommel
Monospiral arrangement
Guide
Aligned cable support
Kabelweg
Controlled bending in one plane

Monospiral reel systems

For routes that keep the cable flat through the reel and guides, with bending controlled in one plane.

Intended movement

Stackers & reclaimers

Match the guide path, travel speed, installed length and environmental exposure to the selected construction.

Application review

Twisting or multi-plane routes

These need a separate selection review. A round reeling cable may be the appropriate starting point.

Review an alternative cable

Power with fibre optics

Ask for a WGF-D configuration. Specify the optical fibre type and count with the power-core requirement.

Optional configuration

For reel fit, include the drum core diameter, guide arrangement, acceleration and operating tension.

Request application review →

Send the reel layout and operating conditions with your enquiry.

Technische Daten

Select your configuration

Published catalogue options; final dimensions and ratings are confirmed during technical review.

The published size schedule covers 3.6/6 kV and 6/10 kV. It does not define 8.7/15 kV or WGF-D fibre configurations.

NTSFLCGEWOEU 3.6/6 and 6/10 kV configuration selection
Model / core configurationWidth × height (mm)Masse ca. (kg/km)Current at 30 °C (A)
(N)TSFLCGEWOEU 3.6/6 kV 3×25+3×25/3E mm²68.5 × 25.22400105
(N)TSFLCGEWOEU 3.6/6 kV 3×35+3×25/3E mm²75.2 × 26.52780130
(N)TSFLCGEWOEU 3.6/6 kV 3×50+3×25/3E mm²82.6 × 293450162
(N)TSFLCGEWOEU 3.6/6 kV 3×70+3×35/3E mm²90.5 × 324580202
(N)TSFLCGEWOEU 3.6/6 kV 3×95+3×50/3E mm²98.8 × 36.55890242
(N)TSFLCGEWOEU 3.6/6 kV 3×120+3×70/3E mm²106.2 × 38.86980282
(N)TSFLCGEWOEU 6/10 kV 3×25+3×25/3E mm²82 × 26.52680105
(N)TSFLCGEWOEU 6/10 kV 3×35+3×25/3E mm²86 × 27.23120130
(N)TSFLCGEWOEU 6/10 kV 3×50+3×25/3E mm²92 × 30.53890162
(N)TSFLCGEWOEU 6/10 kV 3×70+3×35/3E mm²102 × 354920202
(N)TSFLCGEWOEU 6/10 kV 3×95+3×50/3E mm²112 × 38.56290242
(N)TSFLCGEWOEU 6/10 kV 3×120+3×70/3E mm²120.5 × 417380282
(N)TSFLCGEWOEU 6/10 kV 4×35+4×25/4E mm²102 × 27.23780130
(N)TSFLCGEWOEU 6/10 kV 4×70+4×35/4E mm²119.5 × 355890202

Current rating depends on installation conditions.

Electrical & mechanical details

NTSFLCGEWOEU electrical and mechanical catalogue data
Model / core configurationMaximale Zugkraft (N)DC resistance at 20 °C (Ω/km)1 s short circuit (kA)
(N)TSFLCGEWOEU 3.6/6 kV 3×25+3×25/3E mm²11250.7803.58
(N)TSFLCGEWOEU 3.6/6 kV 3×35+3×25/3E mm²15750.5545.01
(N)TSFLCGEWOEU 3.6/6 kV 3×50+3×25/3E mm²22500.3867.15
(N)TSFLCGEWOEU 3.6/6 kV 3×70+3×35/3E mm²31500.27210.01
(N)TSFLCGEWOEU 3.6/6 kV 3×95+3×50/3E mm²42750.20613.59
(N)TSFLCGEWOEU 3.6/6 kV 3×120+3×70/3E mm²54000.16117.16
(N)TSFLCGEWOEU 6/10 kV 3×25+3×25/3E mm²11250.7803.58
(N)TSFLCGEWOEU 6/10 kV 3×35+3×25/3E mm²15750.5545.01
(N)TSFLCGEWOEU 6/10 kV 3×50+3×25/3E mm²22500.3867.15
(N)TSFLCGEWOEU 6/10 kV 3×70+3×35/3E mm²31500.27210.01
(N)TSFLCGEWOEU 6/10 kV 3×95+3×50/3E mm²42750.20613.59
(N)TSFLCGEWOEU 6/10 kV 3×120+3×70/3E mm²54000.16117.16
(N)TSFLCGEWOEU 6/10 kV 4×35+4×25/4E mm²21000.5545.01
(N)TSFLCGEWOEU 6/10 kV 4×70+4×35/4E mm²42000.27210.01

Send the reel layout for review of bending requirements and the selected construction.

Normen

Standards & records

Check the technical references and specify the documents your project requires.

NTSFLCGEWOEU technical references
ReferenzProduktanwendung
IEC 60228Class 5 flexible conductor classification.
IEC 60332-1Referenz für die Flammenausbreitungsprüfung an einer einzelnen Leitung.
DIN VDE 0298-3Installation guidance for the cable route.

Include your document requirements

  • Electrical test records for the supplied length.
  • Dimensions and conductor arrangement.
  • Fibre configuration details, where applicable.

The applicable construction, supply lengths, marking and document package are confirmed with the quotation.

Technical documents

Request verified datasheet

Request a configuration-specific datasheet with your enquiry. Final dimensions and ratings are confirmed during technical review.

Before you enquire

When should I choose this flat cable?

For monospiral reels and guide systems that maintain controlled bending in one plane, including routes with restricted installation height. Match the width and height to the complete reel and guide layout.

Can the cable follow a twisting route?

Twisting and multi-plane movement need a separate cable selection review. Send the complete route, including any S-bends, rather than selecting from voltage and conductor size alone.

Is 8.7/15 kV included in the size table?

No. The published size schedule shown here covers 3.6/6 and 6/10 kV. Request separate dimensions and configuration details for 8.7/15 kV.

Does every construction include fibre?

No. Optical elements are optional in WGF-D configurations. Include the required fibre type and count, along with the power and earth arrangement.

What information helps you quote?

Start with voltage, core configuration, required length and quantity. Add the reel layout, operating current, movement and environment. A cable marking photo or drawing also helps with a replacement enquiry.

Nach Beanspruchung vergleichen

Verwandte Kabeloptionen

Vergleichen Sie diese Kabeloptionen nach der Kombination der Funktionen, Bewegung, Last, Spannung und Übertragungsanforderung.

Angebot auf Grundlage technischer Prüfung

Kabelempfehlung und Angebot anfordern

Senden Sie die benötigten Funktionen, Kabellänge, mechanische Beanspruchung, Umgebung, Anschlussausführung und Menge. Unser Team prüft die Anwendung vor der Angebotserstellung.

  • Geben Sie den Produktnamen oder die SKU sowie die benötigte Kabellänge und Menge an.
  • Fügen Sie nach Möglichkeit eine Spezifikation, Zeichnung oder ein Datenblatt bei.

    Mit dem Absenden dieses Formulars stimmen Sie zu, dass TEBAOFLEX die angegebenen Kontaktdaten und Dateien zur Prüfung und Beantwortung Ihrer Anfrage verwendet. Die Dateien werden für Angebote und die technische Kommunikation zu Ihrer Anfrage genutzt. Lesen Sie unsere Datenschutzerklärung für aktuelle Informationen zur Datenverarbeitung und -aufbewahrung.

    * Pflichtfelder. Bitte geben Sie die wichtigsten Kabel- oder Anwendungsdaten zur Prüfung an.