NTSCGERLWOEU 3.6/6 kV Flexible Submersible Cable
NTSCGERLWOEU cable is a 3.6/6 kV flexible submersible cable for permanent water operation where additional mechanical protection is required. The supplied 3 × 120 + 3 × 70/3E configuration combines class 5 flexible copper conductors, 3GI3 rubber insulation, a galvanised steel-strand braid and a 5GM5 rubber outer sheath.
- Voltaje: 3,6/6 kV
- Reference configuration: 3 × 120 + 3 × 70/3E mm²
- Conductor: flexible stranded copper, class 5
- Protección mecánica: galvanised steel-strand braid
- Vaina interior: waterproof synthetic butyl rubber
- Vaina exterior: 5GM5 rubber; red shown in the supplied cross-section
- Referencia estándar: VDE 0250 Parte 813
Send the cable marking, route, quantity, water-duty conditions, termination details and documentation requirements for a technical quotation.
NTSCGERLWOEU 3.6/6 kV flexible submersible cable
TEBAOFLEX NTSCGERLWOEU cable is a flexible medium-voltage power cable for permanent operation in water where the route also requires added mechanical protection. The supplied 3 × 120 + 3 × 70/3E reference configuration has a galvanised steel-strand braid and rubber sheathing, helping procurement teams identify it as a protected water-duty construction rather than an ordinary flexible power cable.
This page is deliberately specific to the supplied 3.6/6 kV configuration. It records the available diameter range and approximate weight, while leaving unsupplied project limits—such as water depth, bending radius, current capacity and tensile load—to the approved cable drawing. That distinction matters: a cable can look suitably armoured on a reel yet still be wrong for the route, termination or earth-core arrangement.
- Adecuado para: permanent water-operation duties requiring a flexible, mechanically protected medium-voltage cable.
- Reference size: 3 × 120 + 3 × 70/3E mm², with a 75–80 mm overall-diameter range.
- Confirmar antes de realizar el pedido: installation route, water conditions, cable support, earth and pilot-core requirement, length and test documents.
- Elija otra construcción cuando: the project needs a proven depth rating, a stated movement/reeling rating or electrical values not supplied for this configuration.
Explora el Gama de cables para bombas sumergibles for other water-duty power-cable options. The technical details for this model are in the Construction, Applications, Specifications and Standards tabs.
NTSCGERLWOEU cable construction
The supplied NTSCGERLWOEU construction uses flexible class 5 stranded copper conductors, conductive rubber layers around 3GI3 rubber insulation, and a galvanised steel-strand braid. This layer sequence combines electrical field-control materials with added mechanical protection for the stated water-operation duty.

| Elemento constructivo | Supplied material or arrangement |
|---|---|
| Conductores de fase | Flexible stranded copper, class 5 according to DIN VDE 0295 |
| Inner conductor layer | Special conductive rubber compound |
| Aislamiento | Rubber type 3GI3 |
| Outer conductor layer | Special conductive rubber, easy strippable |
| núcleos piloto | Optional copper conductor with EPR insulation |
| conductor de tierra | Spiral of tinned annealed copper wires |
| vaina interior | Waterproof synthetic butyl rubber |
| Blindaje | Braid of galvanised steel strands |
| Vaina exterior | Rubber type 5GM5; red on the supplied cross-section image |
Aplicaciones
NTSCGERLWOEU is specified for permanent operation in water where the cable also needs additional mechanical protection. The supplied construction is relevant to submerged fixed-service power connections for equipment such as pumps, dredging equipment and similar water-duty installations where the final project design calls for a braided flexible medium-voltage cable.
Selection checks before ordering
- Confirm the required voltage, route length, termination system and whether optional pilot cores are needed.
- Confirm the 3 × 120 + 3 × 70/3E conductor arrangement against the connected equipment and earthing design.
- Define the installation path, support points and strain-relief arrangement; the steel braid provides mechanical protection but does not replace project-specific suspension or termination design.
- State water conditions, immersion depth, movement and any inspection or test-document requirement. These limits are not supplied for this specific configuration and must be reviewed for the quotation.
TEBAOFLEX can review the existing cable marking, conductor arrangement and installation duty before issuing a technical quotation, helping the buyer avoid ordering a similar-looking construction with a different earth or pilot-core layout.
Especificaciones
The following values are the supplied reference data for the NTSCGERLWOEU 3.6/6 kV configuration. Confirm the final cable drawing and dimensions before release to production.
| Modelo | NTSCGERLWOEU |
|---|---|
| Tensión nominal | 3,6/6 kV |
| Reference core configuration | 3 × 120 + 3 × 70/3E mm² |
| Minimum overall diameter | 75 mm |
| Maximum overall diameter | 80 mm |
| Approximate weight | 9,980 kg/km |
| Installation duty stated in supplied material | Permanent operation in water with additional mechanical protection |
Ordering boundary
Only the 3 × 120 + 3 × 70/3E reference size, diameter range and approximate weight were supplied. Temperature limits, bending radius, tensile load, water depth, current capacity, resistance, test voltage and reeling speed were not supplied for this configuration, so they are not stated as product claims.
Normas
The supplied technical information identifies the following standard references for NTSCGERLWOEU. Include the required standard edition and any project-specific inspection or test documentation in the RFQ.
| Cable standard reference | VDE 0250 Parte 813 |
|---|---|
| Conductor class reference | DIN VDE 0295, class 5 |
Confirm the required edition, final documentation and test requirements for the ordered cable configuration in the RFQ.
Opciones de cable relacionadas
Compare estas opciones de cable según la combinación de servicios, el movimiento, la carga, el voltaje y los requisitos de transmisión.
Cable NTSCGEWOEU-W de 3,6/6 kV a 18/30 kV
Una opción de cable relacionada para una aplicación o perfil de trabajo diferente.
Ver productoCable sumergible (N)TSCGECEWÖU 3,6/20 kV | Cable para bombas mineras de 300 m
Una opción de cable relacionada para una aplicación o perfil de trabajo diferente.
Ver productoCable para motor de bomba sumergible 450/750V 0.6/1kV con núcleos de control
Una opción de cable relacionada para una aplicación o perfil de trabajo diferente.
Ver productoSolicite una recomendación y un presupuesto de cables.
Indique los servicios requeridos, la longitud del cable, la carga mecánica, el entorno, el tipo de terminación y la cantidad. Nuestro equipo revisará la solicitud antes de elaborar un presupuesto.
- Incluya el nombre del producto o SKU, así como la longitud y la cantidad de cable requeridas.
- Adjunte una especificación, un dibujo o una hoja de datos cuando esté disponible.