Solicita un presupuesto
CABLES PARA MINERÍA Y TÚNELES TEBAOFLEX

Mine Feeder Type 1 Screened Machine Cable 1.1/1.1 kV

Mine Feeder Type 1 cable is a 1.1/1.1 kV AS/NZS 1972 screened machine cable with PVC insulation and cover.

  • V-90 PVC insulated tinned annealed copper conductors
  • Individually or collectively screened configurations
  • Tinned copper wire and polyester yarn composite braid screen
  • Heat-resistant 5V-90 PVC cover
  • For continuous miners, shuttle cars, road headers and personnel transporters
  • Further mechanical protection required for external non-protected installations

State the screen configuration, core count, area and machine route in the RFQ.

Información del producto
Marca
TEBAOFLEX
Descripción general del producto

Mine Feeder Type 1 cable for screened machine wiring

Mine Feeder Type 1 cable is a 1.1/1.1 kV PVC-insulated and PVC-covered screened machine cable in the supplied AS/NZS 1972 datasheet. The source describes individually screened and collectively screened configurations for mobile equipment such as continuous miners, shuttle cars, road headers and personnel transporters. It also identifies interconnection between control boxes and motors as a use case.

This is a different procurement path from the higher-voltage AS/NZS 2802 surface trailing families. The construction uses tinned annealed copper, heat-resistant V-90 PVC insulation, a tinned copper wire and polyester yarn composite braid screen, and a heat-resistant 5V-90 PVC cover. The electrical and dimensions/mass tables separate individual and collective screening, so the screening choice must be carried into the cable schedule and termination plan.

The datasheet says further mechanical protection is required for external non-protected installations. Confirm the actual duct, machine enclosure, control interface, conductor area, core count and length before requesting a quotation. Current capacity and mechanical limits should come from the project design rather than a generic Type 1 label.

Construcción

Mine Feeder Type 1 PVC screened construction

Mine Feeder Type 1 is built around heat-resistant PVC materials and offers individual or collective screening. The two arrangements are retained in separate source tables so the electrical and dimensional selection remains explicit.

Mine Feeder Type 1 cable cross-section showing PVC cores and composite braid screen
Supplied Mine Feeder Type 1 cross-section showing the PVC screened machine-cable build.
Construction identified in the supplied datasheet
ParámetroValor indicado en la fuente
ConductorTinned annealed copper
AislamientoHeat-resistant V-90 PVC
PantallaTinned copper wire and polyester yarn composite braid
Screening optionIndividually or collectively screened
CoverHeat-resistant 5V-90 PVC
Installation noteFurther mechanical protection for external non-protected installations

The supplied cross-section is shown here, while the individual and collective screening tables remain in Specifications. Match the screen type to the machine protection and control design.

Aplicaciones

Mine Feeder Type 1 machine applications

The source language is machine-focused rather than reel-focused. It names underground mobile equipment and ducted machine wiring, with a specific protection warning for external non-protected routes.

  • Continuous miners, shuttle cars and road headers
  • Personnel transporters and machine control-box/motor interconnection
  • Ducted machine installations using the selected core count and screen arrangement
  • External non-protected installations only with the further mechanical protection stated by the source

Confirm the enclosure, duct, entry protection, screen termination and core count before ordering. The source does not add an oil, UV or general outdoor suitability claim.

Especificaciones

Mine Feeder Type 1 Screened Machine Cable 1.1/1.1 kV technical data

The dimensional and electrical values below are transcribed from the supplied PDF for Mine Feeder Type 1 cable. The tables are retained by voltage, screen option or construction section as presented in the source. Source ordering codes are included where present in the extracted table; blank source cells are not assigned new values.

Use the relevant area, conductor dimensions, insulation or covering thickness, nominal diameter and mass together. The source does not create a universal current-capacity, bend-radius, pulling-load or travel-speed value for this product.

1.1/1.1 kV TYPE 1 - INDIVIDUALLY SCREENED - ELECTRICAL DATA

1.1/1.1 kV TYPE 1 - INDIVIDUALLY SCREENED - ELECTRICAL DATA
Area mm2NúcleosCond. dia. mmInsul. thick. mmAC res. 90 deg C oh/kmReact. 50 Hz oh/kmVolt drop mV/A.mMax DC res. combined oh/km
1.521.60.817.50.12030.313.7
1.531.60.817.50.12030.313.7
1034.61.02.580.09234.476.06
1636.21.01.580.08542.743.72
1.541.60.817.50.12830.313.7
1044.61.02.580.09984.476.06
1646.21.01.580.09292.743.72

1.1/1.1 kV TYPE 1 - INDIVIDUALLY SCREENED - DIMENSIONS AND MASS

1.1/1.1 kV TYPE 1 - INDIVIDUALLY SCREENED - DIMENSIONS AND MASS
Area mm2NúcleosCovering thick. mmNom. dia. mmApprox mass kg/100m
1.520.810.215
1.530.810.820
1031.018.160
1631.322.085
1.540.811.925
1041.320.575
1641.324.3110

1.1/1.1 kV TYPE 1 - COLLECTIVELY SCREENED - ELECTRICAL DATA

1.1/1.1 kV TYPE 1 - COLLECTIVELY SCREENED - ELECTRICAL DATA
Area mm2NúcleosCond. dia. mmInsul. thick. mmAC res. 90 deg C oh/kmReact. 50 Hz oh/kmVolt drop mV/A.mMax DC res. combined oh/km
1.521.60.817.50.10630.313.7
1.531.60.817.50.10630.313.7
1.541.60.817.50.11430.313.7
1.561.60.817.50.12330.313.7
1.5161.60.817.50.15230.313.7
1.5301.60.817.50.16930.313.7

1.1/1.1 kV TYPE 1 - COLLECTIVELY SCREENED - DIMENSIONS AND MASS

1.1/1.1 kV TYPE 1 - COLLECTIVELY SCREENED - DIMENSIONS AND MASS
Area mm2NúcleosCovering thick. mmNom. dia. mmApprox mass kg/100m
1.520.89.3815
1.530.89.8815
1.540.810.720
1.561.012.825
1.5161.318.855
1.5301.524.790

4 technical tables were transcribed from the supplied datasheet; confirm final selection against the original PDF and project cable schedule.

Estándares

Mine Feeder Type 1 standard and installation note

The source identifies this product as a Type 1 cable to AS/NZS 1972. The table records its low-voltage and installation boundaries.

Source-listed standard and service limits
ParámetroValor indicado en la fuente
Norma del productoAS/NZS 1972
Tensión nominal1,1/1,1 kV
Temperatura máxima de funcionamiento continuo+90 °C
Minimum installation temperature0 °C
InstalaciónIn duct for machines
External non-protected installationFurther mechanical protection required
Comportamiento frente a la llamaC3

State individually or collectively screened, core count, area, machine type and protection method in the RFQ. The source notes that cables rated in excess of 20 amps are electrically symmetrical.

Comparar por impuesto

Opciones de cable relacionadas

Compare estas opciones de cable según la combinación de servicios, el movimiento, la carga, el voltaje y los requisitos de transmisión.

Cotización basada en ingeniería

Solicite una recomendación y un presupuesto de cables.

Indique los servicios requeridos, la longitud del cable, la carga mecánica, el entorno, el tipo de terminación y la cantidad. Nuestro equipo revisará la solicitud antes de elaborar un presupuesto.

  • Incluya el nombre del producto o SKU, así como la longitud y la cantidad de cable requeridas.
  • Adjunte una especificación, un dibujo o una hoja de datos cuando esté disponible.

    Opcional: adjunte una especificación del cable, un dibujo, una hoja de datos o una imagen del producto (PDF, DOC, DOCX, XLS, XLSX, CSV, JPG o PNG; máximo 10 MB).

    Al enviar este formulario, usted acepta que TEBAOFLEX pueda utilizar la información de contacto y los archivos proporcionados para revisar y responder a su consulta. Los archivos se utilizan para la cotización y la comunicación técnica relacionada con su solicitud. Consulte nuestra política de privacidad para obtener información actualizada sobre el manejo y la retención de datos.

    * Campos obligatorios. Incluya el cable clave o los detalles de la aplicación para su revisión.