CABLES PARA MINERÍA Y TÚNELES TEBAOFLEX

Mine Feeder Type 2S and Type 2S.3 Screened Machine Cable 1.1/1.1–3.3/3.3 kV

Mine Feeder Type 2S / Type 2S.3 cable covers 1.1/1.1 and 3.3/3.3 kV screened elastomer cable for mobile mining equipment.

  • EPR R-EP-90 insulated tinned annealed copper
  • Individually or collectively screened configurations
  • Pilot provided where required by the cable arrangement
  • Black HD-90-CPE sheath
  • Continuous miners, shuttle cars, road headers and longwall lighting
  • +90 °C continuous operating; −25 °C minimum installation

Specify Type 2S or Type 2S.3, screen method, area and pilot requirement.

Información del producto
Marca
TEBAOFLEX
Descripción general del producto

Mine Feeder Type 2S and Type 2S.3 cable

Mine Feeder Type 2S and Type 2S.3 cable is an elastomer-insulated and sheathed screened machine-cable family for mobile mining equipment. The supplied datasheet separates Type 2S at 1.1/1.1 kV from Type 2S.3 at 3.3/3.3 kV, then further separates individually and collectively screened constructions in the technical tables. Keeping those choices visible helps prevent a low-voltage Type 2S enquiry from being treated as a generic Type 2S.3 match.

The construction uses tinned annealed copper, EPR R-EP-90 insulation and a tinned copper wire/polyester yarn composite braid screen. A pilot is included where required, and the black HD-90-CPE sheath completes the assembly. The source identifies continuous miners, shuttle cars, road headers, personnel transporters, equipment interconnection and longwall lighting as relevant applications.

Type 2S is stated as sheathed and not requiring further mechanical protection for external non-protected installations. Selection still depends on voltage, screen method, core count, pilot requirement, route and termination. The PDF does not supply a universal current or mechanical-duty rating, so those requirements belong in the RFQ.

Construcción

Type 2S / Type 2S.3 elastomer screened construction

This family combines a shared elastomeric build with two voltage designations and two screening options. Type 2S is the 1.1/1.1 kV designation; Type 2S.3 is the 3.3/3.3 kV designation in the supplied sheet.

Mine Feeder Type 2S and Type 2S.3 cross-section showing EPR cores, screen, pilot and CPE sheath
Supplied Mine Feeder Type 2S/2S.3 cross-section showing the elastomer screened arrangement.
Construction identified in the supplied datasheet
ParámetroValor indicado en la fuente
ConductorTinned annealed copper
AislamientoEPR R-EP-90
PilotTinned annealed copper pilot, R-EP-90 insulated where required
PantallaTinned copper wire and polyester yarn composite braid
Screening optionCores can be individually or collectively screened
VainaHD-90-CPE black sheath

The cross-section is kept in Construction; the Type 2S, Type 2S.3, individual-screen and collective-screen tables are retained separately in Specifications.

Aplicaciones

Type 2S and Type 2S.3 machine applications

The supplied application note connects this family to mobile equipment and longwall support functions. The voltage designation and screening mode should be selected from the machine cable schedule, not from the equipment name alone.

  • Continuous miners, shuttle cars and road headers
  • Personnel transporters and equipment interconnection
  • Longwall lighting systems where the specified cable construction matches
  • External non-protected installations covered by the source statement that Type 2S cables are sheathed and do not require further mechanical protection

Confirm screen continuity, pilot use, core count, route, entry protection and termination hardware. Do not extend the Type 2S external-installation statement to a different product or unlisted mechanical duty.

Especificaciones

Mine Feeder Type 2S and Type 2S.3 Screened Machine Cable 1.1/1.1–3.3/3.3 kV technical data

The dimensional and electrical values below are transcribed from the supplied PDF for Mine Feeder Type 2S Type 2S.3 cable. The tables are retained by voltage, screen option or construction section as presented in the source. Source ordering codes are included where present in the extracted table; blank source cells are not assigned new values.

Use the relevant area, conductor dimensions, insulation or covering thickness, nominal diameter and mass together. The source does not create a universal current-capacity, bend-radius, pulling-load or travel-speed value for this product.

1.1/1.1 kV TYPE 2S - INDIVIDUALLY SCREENED - ELECTRICAL DATA

1.1/1.1 kV TYPE 2S - INDIVIDUALLY SCREENED - ELECTRICAL DATA
Area mm2NúcleosCond. dia. mmInsul. thick. mmAC res. 90 deg C oh/kmReact. 50 Hz oh/kmVolt drop mV/A.mMax DC res. combined oh/km
1024.61.02.580.09534.476.06
1626.21.01.580.08792.743.72
1034.61.02.580.09534.476.06
1636.21.01.580.08792.743.72
1044.61.02.580.1034.476.06
1646.21.01.580.09542.743.72
1626.21.01.580.07862.743.72
623.51.04.320.09367.488.21
1024.61.02.580.08604.476.06
1626.21.01.580.07862.743.72
633.51.04.320.1197.498.21
1034.61.02.580.1044.476.06
1636.21.01.580.08792.743.72
2537.21.20.9510.08701.652.24
3538.41.20.6980.08371.221.64
5039.71.40.5230.08280.9171.23

1.1/1.1 kV TYPE 2S - INDIVIDUALLY SCREENED - PILOT, DIMENSIONS AND MASS

1.1/1.1 kV TYPE 2S - INDIVIDUALLY SCREENED - PILOT, DIMENSIONS AND MASS
Area mm2NúcleosPilot area mm2núcleos pilotoSheath thick. mmNom. dia. mmApprox mass kg/100m
102--1.818.960
162--1.822.185
103--1.820.175
163--1.823.5105
104--1.822.195
164--1.825.9130
162111.822.1100
62121.816.950
102121.819.065
162121.822.190
63131.819.870
103131.821.385
163131.823.5110
253131.826.8155
353131.829.5190
503131.933.4245

3.3/3.3 kV TYPE 2S.3 - INDIVIDUALLY SCREENED - ELECTRICAL DATA

3.3/3.3 kV TYPE 2S.3 - INDIVIDUALLY SCREENED - ELECTRICAL DATA
Area mm2NúcleosCond. dia. mmInsul. thick. mmAC res. 90 deg C oh/kmReact. 50 Hz oh/kmVolt drop mV/A.mMax DC res. combined oh/km
1034.63.02.580.1254.476.06
1636.23.01.580.1162.743.72
2537.23.00.9510.1101.662.24
3538.43.00.6980.1051.221.64
5039.73.00.5230.1010.9231.23
70312.03.00.3460.09500.6210.813
95313.33.00.2710.09260.4960.636
120315.33.00.2100.08970.3960.492

3.3/3.3 kV TYPE 2S.3 - INDIVIDUALLY SCREENED - PILOT, DIMENSIONS AND MASS

3.3/3.3 kV TYPE 2S.3 - INDIVIDUALLY SCREENED - PILOT, DIMENSIONS AND MASS
Area mm2NúcleosPilot area mm2núcleos pilotoSheath thick. mmNom. dia. mmApprox mass kg/100m
1031.531.830.5140
1631.531.934.7185
2531.532.037.3235
3531.532.039.8275
5031.532.142.8325
7031.532.348.3435
9531.532.451.4515
12031.532.556.4640

1.1/1.1 kV TYPE 2S - COLLECTIVELY SCREENED - ELECTRICAL DATA

1.1/1.1 kV TYPE 2S - COLLECTIVELY SCREENED - ELECTRICAL DATA
Area mm2NúcleosCond. dia. mmInsul. thick. mmAC res. 90 deg C oh/kmReact. 50 Hz oh/kmVolt drop mV/A.mMax DC res. combined oh/km
1.521.61.017.50.11830.313.7
1.531.61.017.50.11930.313.7
1.541.61.017.50.12630.313.7
1.561.61.017.50.13530.313.7
1.5161.61.017.50.16430.313.7
1.5301.61.017.50.18130.313.7

1.1/1.1 kV TYPE 2S - COLLECTIVELY SCREENED - PILOT, DIMENSIONS AND MASS

1.1/1.1 kV TYPE 2S - COLLECTIVELY SCREENED - PILOT, DIMENSIONS AND MASS
Area mm2NúcleosPilot area mm2núcleos pilotoSheath thick. mmNom. dia. mmApprox mass kg/100m
1.52--1.812.220
1.53--1.812.725
1.54--1.813.725
1.56--1.816.035
1.516--1.822.875
1.530--1.829.1120

6 technical tables were transcribed from the supplied datasheet; confirm final selection against the original PDF and project cable schedule.

Estándares

Type 2S / Type 2S.3 voltage references

The source identifies the family to AS/NZS 1972 and distinguishes Type 2S from Type 2S.3 by voltage. The values below keep that distinction explicit.

Source-listed standard and service limits
ParámetroValor indicado en la fuente
Norma del productoAS/NZS 1972
Type 2S1,1/1,1 kV
Type 2S.33,3/3,3 kV
Temperatura máxima de funcionamiento continuo+90 °C
Minimum installation temperature−25 °C
InstalaciónFree air for mobile equipment
Oil / water performanceVery good immersion performance and very good flexibility
Comportamiento frente a la llamaC1

Put the exact Type 2S or Type 2S.3 designation, screen mode, pilot requirement and machine route into the RFQ.

Comparar por impuesto

Opciones de cable relacionadas

Compare estas opciones de cable según la combinación de servicios, el movimiento, la carga, el voltaje y los requisitos de transmisión.

Cotización basada en ingeniería

Solicite una recomendación y un presupuesto de cables.

Indique los servicios requeridos, la longitud del cable, la carga mecánica, el entorno, el tipo de terminación y la cantidad. Nuestro equipo revisará la solicitud antes de elaborar un presupuesto.

  • Incluya el nombre del producto o SKU, así como la longitud y la cantidad de cable requeridas.
  • Adjunte una especificación, un dibujo o una hoja de datos cuando esté disponible.

    Opcional: adjunte una especificación del cable, un dibujo, una hoja de datos o una imagen del producto (PDF, DOC, DOCX, XLS, XLSX, CSV, JPG o PNG; máximo 10 MB).

    Al enviar este formulario, usted acepta que TEBAOFLEX pueda utilizar la información de contacto y los archivos proporcionados para revisar y responder a su consulta. Los archivos se utilizan para la cotización y la comunicación técnica relacionada con su solicitud. Consulte nuestra política de privacidad para obtener información actualizada sobre el manejo y la retención de datos.