Solicita un presupuesto
CABLES PARA MINERÍA Y TÚNELES TEBAOFLEX

Type 621 BS 6708 3800/6600 V Armoured Mining Cable

Type 621 mining cable for excavating and crushing machines in deep mines and on the surface, with the source-defined 3800/6600 V rating and 15 kV test reference.

  • Model: Type 621
  • Conductor and insulation: flexible tinned copper with the insulation and core construction listed for this model in the supplied PDF
  • Screen, pilot, earth and armour arrangement preserved from the source datasheet
  • Heavy-duty chloroprene or PCP outer protection as listed for this model
  • Original Type datasheet available as the product download

Send the equipment, voltage, conductor area, route, quantity and document requirements for an RFQ.

Información del producto
Marca
TEBAOFLEX
Descripción general del producto

Type 621 for excavating and crushing machines in deep mines and on the surface

Type 621 mining cable is specified in the supplied BS 6708 datasheet for excavating and crushing machines in deep mines and on the surface. This page keeps the source-listed voltage, test reference, core functions and dimensional tables together so a procurement engineer can compare the requested model against the cable marking and the equipment connection. The editorial focus is the unscreened-core armoured 6.6 kV selection, not a generic promise of performance.

The supplied construction uses three phase cores and one pilot core, all unscreened, laid up in contact with one another and protected by galvanized steel pliable armour between inner and outer sheaths. That arrangement matters because Type 621 is armoured and unscreened; it is therefore a different construction path from individually screened Type 630/631 and Type 730. The family should therefore be selected by model, core function and installation route as well as by voltage. The Gama de cables para minería y túneles provides the wider TEBAOFLEX product context.

  • Elegir por: confirm that the machine design accepts the unscreened three-phase and pilot arrangement before comparing Type 621 with Type 630 or Type 730.
  • Confirmar antes de realizar el pedido: existing sheath marking, conductor area, cable length, route, support or handling system, terminations and the required inspection documents.
  • Do not infer: values not listed in the supplied PDF, such as a different current basis, water/oil/UV performance, certification scope or mechanical interchangeability.

For a project review that includes equipment connection, cable handling and documentation, use the Mining & Tunnelling solutions page as a planning companion to this Type 621 data.

For a technical quotation, send the equipment nameplate or existing cable marking, voltage and size requirement, installation conditions, quantity, destination and any project-specific test or documentation requirement.

Construcción

Type 621 construction

The cross-section below is the supplied construction drawing for Type 621. The ordering decision is driven by Type 621 is armoured and unscreened; it is therefore a different construction path from individually screened Type 630/631 and Type 730.

Type 621 cable cross-section showing the supplied power, pilot, earth, screen and protection arrangement
Supplied Type 621 cross-section; the exact core and armour arrangement must be checked against the product datasheet.

Source-listed construction

Elemento de construcciónValor indicado en la fuente
ConductorElectrolytic stranded tinned copper wire, IEC 60228 Class 5
AislamientoAislamiento EPR
bandejaCores laid up over each other
ArmaduraArmadura flexible de acero galvanizado
VainaHeavy-duty chloroprene outer sheath
Disposición centralThree phase cores and one pilot core, all unscreened, laid up in contact; pliable armour between inner and outer sheaths

Do not use the drawing as a substitute for the dimensional tables. Confirm the cable end preparation, screen and earth termination, armour bonding and machine interface with the equipment documentation before installation.

Aplicaciones

Type 621 applications

Type 621 mining cable application with surface mining excavator equipment
Media-library application scene showing surface mining excavator equipment; used for application context, not as a model-specific construction proof.

The supplied datasheet identifies this cable for excavating and crushing machines in deep mines and on the surface. Google result patterns for the BS 6708 family also separate cables by equipment duty, voltage class, core function and whether the route is armoured, screened, flat or auxiliary. That is why this page keeps the Type 621 construction separate from nearby Type numbers.

  • Primary duty: excavating and crushing machines in deep mines and on the surface.
  • Model boundary: Type 621 is armoured and unscreened; it is therefore a different construction path from individually screened Type 630/631 and Type 730.
  • Project check: match the cable marking, core map, voltage, termination, route geometry and handling method to the machine drawing.
  • Environmental review: confirm the actual mine/quarry conditions and any authority, inspection or documentation requirements; do not infer a certification or material-resistance claim from the model number.

For projects evaluating the paired Type 630/631 construction, see the Type 630/631 armoured mining cable page and compare the source-listed core and armour details.

The cable should be released only after the equipment route, required length, conductor area, core functions and connection details are agreed. If the intended duty is different from the source-listed application, request an engineering review through the quotation process.

Especificaciones

Type 621 specifications

The summary below identifies the supplied model family. The source-transcribed tables that follow retain the PDF's dimensional, electrical and construction values, including available sizes, resistance, current, diameter, mass, bending or pulling data when the PDF provides them.

Selection itemSource-linked value
ModeloType 621
Tensión nominal3800/6600 V
Voltaje de prueba15 kV
Aplicaciónexcavating and crushing machines in deep mines and on the surface
Norma del productoBS 6708

Complete source-transcribed technical tables

Source PDF: BS6708_TYPE_621_3800_6600V_ARMOURED_POWER_CABLE_datasheet.pdf; 3 pages; 6 extracted tables. Values are not recalculated or replaced by third-party values.

Source table 1, PDF page 1
ParámetroValor
ConductorElectrolytic, stranded, tinned copper wire, IEC 60228 Class 5
AislamientoEPR
bandejaCores are laid up over each other
LechoRubber based bedding compound
ArmaduraArmadura flexible de acero galvanizado
Cubierta exteriorHeavy duty chloroprene outer sheath
Source table 2, PDF page 1
ParámetroValor
EstándarBS 6708
Tensión nominal3800/6600 V
Voltaje de prueba15 kV
Tipo de cableThree phase cores and one pilot core, all unscreened, laid up in contact with each other; pliable armour between inner and outer sheaths
Source table 1, PDF page 2
CORE DIMENSIONS
Nominal cross sectionConductoresStranding mmConductor diameter mmInsulation thickness mm
4x354x35276/0.408.405.0
4x504x50396/0.4010.105.0
4x704x70360/0.5011.905.0
4x954x95475/0.5013.905.0
4x1204x120608/0.5015.505.0
4x1504x150756/0.5017.205.0
Source table 2, PDF page 2
CABLE DETAILS
Nominal Ecross sectionInner sheath thickness mmMin. inner sheath dia. mmMax. inner sheath dia. mmArmour size mmOuter sheath thickness mmMin. OD mmMax. OD mmMin. bend radius mmApprox. weight kg/kmCopper weight kg/km
4x353.853.856.87/0.906.071.275.275289001350
4x505.060.563.57/1.256.381.085.3853111001950
4x705.065.669.47/1.257.087.191.4914130002700
4x955.070.774.57/1.257.593.297.5975140503700
4x1205.074.378.17/1.257.897.4101.71017206004650
4x1505.079.283.27/1.258.3103.3107.61076220005800
Source table 1, PDF page 3
CURRENT RATINGS
Nominal cross sectionContinuous current rating at 25 deg C
4x35135
4x50170
4x70205
4x95250
4x120295
4x150320
Source table 2, PDF page 3
ELECTRICAL DETAILS
Nominal cross sectionConductors Max. DC res. at 20 deg C ohm/kmArmour Max. DC res. at 20 deg C ohm/km
4x350.5650.70
4x500.3930.50
4x700.2770.43
4x950.2100.39
4x1200.1640.38
4x1500.1320.35

Use the table values with the equipment drawing and approved termination plan. If the requested conductor area, current basis, mechanical limit or environmental condition is not listed in the supplied PDF, treat it as a quotation-stage confirmation item.

Estándares

Type 621 standards and references

TemaSource-linked reference
Norma del productoBS 6708
Tensión nominal3800/6600 V
Voltaje de prueba15 kV
Source applicationexcavating and crushing machines in deep mines and on the surface

The product page preserves the BS 6708 reference appearing in the supplied PDF. The BSI record currently identifies BS 6708:1998 as withdrawn on 22 May 2026; this status note is a standards-reference update, not a claim that the product is currently certified or approved. See the official BSI BS 6708 scope record for the published status.

For an RFQ, state the required standard documents, inspection scope, test report, cable marking, destination rules and any replacement-equivalence requirement. The model number alone does not establish legal installation compliance.

Comparar por impuesto

Opciones de cable relacionadas

Compare estas opciones de cable según la combinación de servicios, el movimiento, la carga, el voltaje y los requisitos de transmisión.

Cotización basada en ingeniería

Solicite una recomendación y un presupuesto de cables.

Indique los servicios requeridos, la longitud del cable, la carga mecánica, el entorno, el tipo de terminación y la cantidad. Nuestro equipo revisará la solicitud antes de elaborar un presupuesto.

  • Incluya el nombre del producto o SKU, así como la longitud y la cantidad de cable requeridas.
  • Adjunte una especificación, un dibujo o una hoja de datos cuando esté disponible.

    Opcional: adjunte una especificación del cable, un dibujo, una hoja de datos o una imagen del producto (PDF, DOC, DOCX, XLS, XLSX, CSV, JPG o PNG; máximo 10 MB).

    Al enviar este formulario, usted acepta que TEBAOFLEX pueda utilizar la información de contacto y los archivos proporcionados para revisar y responder a su consulta. Los archivos se utilizan para la cotización y la comunicación técnica relacionada con su solicitud. Consulte nuestra política de privacidad para obtener información actualizada sobre el manejo y la retención de datos.

    * Campos obligatorios. Incluya el cable clave o los detalles de la aplicación para su revisión.