Yêu cầu báo giá
CÁP CÔNG NGHIỆP TEBAOFLEX

NSGAFOEU 1.8/3kV Medium Voltage Single-Core Cable

NSGAFOEU 1.8/3kV Medium Voltage Single-Core Cable is a TEBAOFLEX cable for the application and operating conditions identified in the original product record. These model distinctions should be preserved in the quotation, order confirmation, production marking and test documentation. A halogen-free compound or metallic screen changes the cable designation and should not be added as a generic NSGAFOEU attribute. The following figures are transcribed from the supplied 1.8/3 kV table. Send the exact size, length, installation duty and documentation requirements for a technical quotation.

Thông tin sản phẩm
SKU
TF-NSGAFOEU
Thương hiệu
TEBAOFLEX
Tổng quan sản phẩm

NSGAFOEU 1.8/3kV Medium Voltage Single-Core Cable is a TEBAOFLEX cable for the application and operating conditions identified in the original product record. These model distinctions should be preserved in the quotation, order confirmation, production marking and test documentation. A halogen-free compound or metallic screen changes the cable designation and should not be added as a generic NSGAFOEU attribute. The following figures are transcribed from the supplied 1.8/3 kV table. Minimum and maximum diameters help with conduit fill, gland selection, termination space, support cleats and routing clearance. Confirm final production dimensions for the selected cross-section before freezing equipment interfaces. Data check required: the 1 x 400 mm² row in the supplied image lists a 40.0 mm minimum diameter and a 34.6 mm maximum diameter. Because a minimum cannot exceed the maximum, this row should remain unpublished as a purchasable variation until the original datasheet or factory specification confirms both values. NSGAFOEU is a 1.8/3 kV medium-voltage single-core cable for protected fixed wiring and selected movable connections in railway vehicles, buses, pipes, enclosed ducts and switchgear. Its Class 5 tinned-copper conductor and rubber construction combine routing flexibility with a compact, mechanically protected power connection. The source record places this product in industrial cables. Before ordering, confirm the exact product variant, conductor or core arrangement, system rating, route conditions, equipment connection and required documentation against the project specification.

Cấu tạo

NSGAFOEU 1.8/3kV Medium Voltage Single-Core Cable construction

Cấu tạo cáp

  1. Ruột dẫn: Flexible stranded tinned-copper wires, Class 5 according to DIN VDE 0295 / IEC 60228.
  2. Inner conductor layer: A semiconducting layer is included in the 3.6/6 kV construction. This layer is not identified as part of the 1.8/3 kV build in the supplied diagram.
  3. Cách điện: EPR rubber compound type 3GI3 or 3GJ3.
  4. Vỏ ngoài: Chlorinated rubber compound type 5GM3, stated as oil-resistant and flame-retardant.
Ứng dụng

NSGAFOEU 1.8/3kV Medium Voltage Single-Core Cable applications

AC Single-Core Installation Considerations

  • Keep circuit conductors together: Arrange all phases of an AC circuit in the specified trefoil or flat formation so their magnetic fields remain balanced and loop impedance is controlled.
  • Avoid individual ferromagnetic entries: Do not pass each AC single-core phase separately through a closed steel gland plate or steel conduit without an approved non-magnetic arrangement. Alternating magnetic flux can cause eddy-current heating.
  • Use equal phase lengths: Parallel or phase conductors should follow equivalent routes and have consistent lengths and terminations to limit current imbalance.
  • Support dynamic connections correctly: A cable suitable for connecting movable parts is not automatically a continuous-reeling, drag-chain or torsion cable. Define the movement radius, frequency and restraint system before use.
  • Check grouping and enclosure heat: Enclosed ducts, bundled single cores and crowded switchboards reduce heat dissipation. Apply the current-rating and derating rules for the actual installation.

Ứng dụng

  • Power wiring in railway and other track-bound vehicles
  • Electrical connections in buses and trolley buses
  • Internal connections in switchboards and distribution equipment
  • Low-voltage circuits designed for inherently short-circuit and earth-fault-proof routing
  • Protected installation in pipes, conduits and closed cable ducts
  • Equipment and movable-part connections with a defined bending duty

Kiểm tra khi lựa chọn

Trước khi chốt lựa chọn, hãy xác nhận giao diện kết nối thiết bị, phương pháp lắp đặt, chiều dài tuyến cáp, chế độ chuyển động hoặc uốn, tác động môi trường, yêu cầu về ruột dẫn hoặc lõi và hồ sơ dự án.

Thông số kỹ thuật

NSGAFOEU 1.8/3kV Medium Voltage Single-Core Cable specifications

Các ghi chú kỹ thuật trong nguồn được giữ lại bên dưới. Hãy xác nhận kích thước, dung sai, cơ sở lắp đặt và cấu hình đặt hàng cuối cùng trước khi phê duyệt.

NSGAFOEU 1.8/3kV Dimensions and Weight

The following figures are transcribed from the supplied 1.8/3 kV table. Minimum and maximum diameters help with conduit fill, gland selection, termination space, support cleats and routing clearance. Confirm final production dimensions for the selected cross-section before freezing equipment interfaces.

Data check required: the 1 x 400 mm² row in the supplied image lists a 40.0 mm minimum diameter and a 34.6 mm maximum diameter. Because a minimum cannot exceed the maximum, this row should remain unpublished as a purchasable variation until the original datasheet or factory specification confirms both values.

Bảng kỹ thuật từ nguồn

Các bảng dưới đây giữ nguyên dữ liệu sản phẩm gốc, bao gồm đơn vị, dải giá trị và ví dụ đặt hàng.

Loại sản phẩmFlexible rubber-insulated single-core power cable
Mẫu cápNSGAFOEU / NSGAFÖU
Điện áp danh định1.8/3 kV for the dimension table shown
Higher-Voltage Version3.6/6 kV construction referenced; specification and dimensions to be confirmed separately
Số lõi1
Dải tiết diện danh nghĩa1.5-400 mm² in the supplied data
Ruột dẫnĐồng mạ thiếc bện mềm cấp 5
Tiêu chuẩn ruột dẫnDIN VDE 0295 / IEC 60228
Cách điệnEPR compound type 3GI3 or 3GJ3
Inner Conductor LayerSemiconducting layer for the 3.6/6 kV version
Vỏ ngoàiChlorinated rubber compound type 5GM3
Stated Sheath PerformanceOil-resistant and flame-retardant
Primary InstallationProtected fixed routes and selected movable-part connections
Tiêu chuẩnDIN VDE 0250 Part 602
Mẫu cápConstruction ReferenceKey Distinction
NSGAFOEUDIN VDE 0250 Part 6025GM3 chlorinated-rubber outer sheath; focus product on this page
NSHXAFOEDIN VDE 0250 Part 606HM3 halogen-free outer compound with low-smoke performance stated in the supplied data
NSGAFCMOEURelated screened constructionTinned-copper wire screen; confirm complete standard and build separately
NSHXAFCMOERelated halogen-free screened constructionTinned-copper wire screen with halogen-free sheath system; confirm separately
Core x Nominal Cross-SectionĐường kính tổng thể nhỏ nhấtĐường kính tổng thể lớn nhấtKhối lượng danh nghĩa
1 x 1.5 mm²5.7 mm7.0 mm50 kg/km
1 x 2.5 mm²6.0 mm7.5 mm60 kg/km
1 x 4 mm²6.8 mm9.0 mm80 kg/km
1 x 6 mm²7.3 mm9.5 mm100 kg/km
1 x 10 mm²8.7 mm11.0 mm160 kg/km
1 x 16 mm²10.0 mm13.0 mm230 kg/km
1 x 25 mm²12.4 mm15.0 mm340 kg/km
1 x 35 mm²13.4 mm16.5 mm430 kg/km
1 x 50 mm²14.9 mm18.0 mm580 kg/km
1 x 70 mm²16.6 mm20.5 mm780 kg/km
1 x 95 mm²19.3 mm24.0 mm1030 kg/km
1 x 120 mm²20.8 mm26.0 mm1270 kg/km
1 x 150 mm²23.0 mm28.0 mm1570 kg/km
1 x 185 mm²25.2 mm31.0 mm1900 kg/km
1 x 240 mm²28.1 mm34.5 mm2500 kg/km
1 x 300 mm²30.8 mm38.0 mm3000 kg/km
1 x 400 mm²Source conflict: 40.0 mm minimum and 34.6 mm maximum; confirm before upload4000 kg/km

Thuộc tính sản phẩm gốc

Các thuộc tính sản phẩm được giữ nguyên như được cung cấp và cần đối chiếu với cấu tạo đặt hàng.

Thuộc tính sản phẩm gốc
Loại sản phẩmFlexible single-core rubber power cable
Mẫu cápNSGAFOEU / NSGAFÖU
Điện áp danh định1.8/3 kV
Higher-Voltage Version3.6/6 kV, confirm separately
Số lõi1
Tiết diện danh nghĩa1.5-400 mm² in supplied data
Ruột dẫnĐồng mạ thiếc bện mềm cấp 5
Tiêu chuẩn ruột dẫnDIN VDE 0295 / IEC 60228
Cách điệnEPR compound type 3GI3 or 3GJ3
Inner Conductor LayerSemiconducting layer for 3.6/6 kV version
Màn chắnNone in shown NSGAFOEU construction
Vỏ ngoàiChlorinated rubber type 5GM3
Stated Sheath PropertiesOil-resistant; flame-retardant
Tiêu chuẩnDIN VDE 0250 Part 602
Ứng dụngRailway vehicles, buses, switchgear, pipes and closed ducts
Tiêu chuẩn

NSGAFOEU 1.8/3kV Medium Voltage Single-Core Cable standards and compliance

Các tiêu chuẩn tham chiếu dưới đây được giữ lại từ hồ sơ sản phẩm gốc. Chúng xác định cơ sở của nguồn dữ liệu và không thay thế các yêu cầu chứng nhận hoặc kiểm tra riêng của dự án.

  • Conductor Standard DIN VDE 0295 / IEC 60228
  • Standard DIN VDE 0250 Part 602
  • Conductor: Flexible stranded tinned-copper wires, Class 5 according to DIN VDE 0295 / IEC 60228.
  • NSGAFOEU DIN VDE 0250 Part 602 5GM3 chlorinated-rubber outer sheath; focus product on this page
  • NSHXAFOE DIN VDE 0250 Part 606 HM3 halogen-free outer compound with low-smoke performance stated in the supplied data

Nếu dự án yêu cầu báo cáo thử nghiệm, chứng chỉ, hồ sơ in dấu hoặc phê duyệt kiểm tra, hãy nêu yêu cầu đó trong yêu cầu báo giá.

Báo giá dựa trên đánh giá kỹ thuật

Yêu cầu tư vấn chọn cáp và báo giá

Hãy gửi các chức năng cần thiết, chiều dài cáp, điều kiện làm việc cơ học, môi trường, kiểu đấu nối và số lượng. Đội ngũ của chúng tôi sẽ xem xét ứng dụng trước khi báo giá.

  • Ghi tên sản phẩm hoặc mã SKU cùng chiều dài cáp và số lượng cần thiết.
  • Đính kèm thông số kỹ thuật, bản vẽ hoặc bảng dữ liệu nếu có.

    Khi gửi biểu mẫu này, bạn đồng ý để TEBAOFLEX sử dụng thông tin liên hệ và tệp đã cung cấp để xem xét và trả lời yêu cầu. Các tệp được dùng cho báo giá và trao đổi kỹ thuật liên quan đến yêu cầu của bạn. Xem Chính sách quyền riêng tư để biết thông tin hiện hành về xử lý và lưu giữ dữ liệu.