Type 14 BS 6708 640/1100 V Pilot and Earth Mining Cable
Type 14 mining cable for excavating, crushing and coal-cutting equipment, with the source-defined 640/1100 V rating and 3 kV test reference.
- Model: Type 14
- Conductor and insulation: flexible tinned copper with the insulation and core construction listed for this model in the supplied PDF
- Screen, pilot, earth and armour arrangement preserved from the source datasheet
- Heavy-duty chloroprene or PCP outer protection as listed for this model
- Original Type datasheet available as the product download
Send the equipment, voltage, conductor area, route, quantity and document requirements for an RFQ.
Type 14 for excavating, crushing and coal-cutting equipment
Type 14 mining cable is specified in the supplied BS 6708 datasheet for excavating, crushing and coal-cutting equipment. This page keeps the source-listed voltage, test reference, core functions and dimensional tables together so a procurement engineer can compare the requested model against the cable marking and the equipment connection. The editorial focus is the separate pilot-and-earth selection, not a generic promise of performance.
The supplied construction uses three individually screened phase cores, one unscreened pilot core and one unscreened earth core arranged around an elastomeric cradle, with rubber bedding and a heavy-duty chloroprene sheath. That arrangement matters because Type 14 is a five-core cradle arrangement: the pilot and earth cores are both unscreened. The family should therefore be selected by model, core function and installation route as well as by voltage. The مجموعة كابلات التعدين والأنفاق provides the wider TEBAOFLEX product context.
- اختر حسب: confirm that the installation needs separate unscreened pilot and earth cores rather than the central-earth layout of Type 7.
- تأكيد قبل الطلب: existing sheath marking, conductor area, cable length, route, support or handling system, terminations and the required inspection documents.
- Do not infer: values not listed in the supplied PDF, such as a different current basis, water/oil/UV performance, certification scope or mechanical interchangeability.
استخدم BS 6708 mining cable replacement guide to separate pilot-and-earth layouts from nearby low-voltage Type families during replacement planning.
For a technical quotation, send the equipment nameplate or existing cable marking, voltage and size requirement, installation conditions, quantity, destination and any project-specific test or documentation requirement.
Type 14 construction
The cross-section below is the supplied construction drawing for Type 14. The ordering decision is driven by Type 14 is a five-core cradle arrangement: the pilot and earth cores are both unscreened.

Source-listed construction
| عنصر التركيب | القيمة المدرجة في المصدر |
|---|---|
| موصل | Electrolytic stranded tinned copper wire, IEC 60228 Class 5 |
| العزل | عزل EPR |
| شاشة | Tinned copper and nylon braided screen over phase cores; pilot and earth cores are not screened |
| Pilot and earth | One unscreened pilot core and one unscreened earth core |
| التسديدة السهلة | Three phase cores, pilot and earth laid up around an elastomeric cradle and in contact with each other |
| غمد | Heavy-duty chloroprene outer sheath |
Do not use the drawing as a substitute for the dimensional tables. Confirm the cable end preparation, screen and earth termination, armour bonding and machine interface with the equipment documentation before installation.
Type 14 applications

The supplied datasheet identifies this cable for excavating, crushing and coal-cutting equipment. Google result patterns for the BS 6708 family also separate cables by equipment duty, voltage class, core function and whether the route is armoured, screened, flat or auxiliary. That is why this page keeps the Type 14 construction separate from nearby Type numbers.
- Primary duty: excavating, crushing and coal-cutting equipment.
- Model boundary: Type 14 is a five-core cradle arrangement: the pilot and earth cores are both unscreened.
- Project check: match the cable marking, core map, voltage, termination, route geometry and handling method to the machine drawing.
- Environmental review: confirm the actual mine/quarry conditions and any authority, inspection or documentation requirements; do not infer a certification or material-resistance claim from the model number.
Where the equipment drawing calls for two earth cores, the Type 16 mining cable provides the adjacent model reference; confirm the conductor layout before treating it as an alternative.
The cable should be released only after the equipment route, required length, conductor area, core functions and connection details are agreed. If the intended duty is different from the source-listed application, request an engineering review through the quotation process.
Type 14 specifications
The summary below identifies the supplied model family. The source-transcribed tables that follow retain the PDF's dimensional, electrical and construction values, including available sizes, resistance, current, diameter, mass, bending or pulling data when the PDF provides them.
| Selection item | Source-linked value |
|---|---|
| نموذج | Type 14 |
| الجهد المقنن | 640/1100 فولت |
| جهد الاختبار | 3 كيلو فولت |
| طلب | excavating, crushing and coal-cutting equipment |
| معيار المنتج | BS 6708 |
Complete source-transcribed technical tables
Source PDF: BS6708_TYPE_14_640_1100V_CABLE_datasheet.pdf; 3 pages; 7 extracted tables. Values are not recalculated or replaced by third-party values.
| المعلمة | قيمة |
|---|---|
| موصل | Electrolytic stranded tinned copper wire, IEC 60228 Class 5 |
| العزل | عزل EPR |
| فاصل | Coloured textile tape for core identification |
| شاشة | Tinned copper and nylon braided screen over phase cores; pilot core and earth core are not screened |
| النواة التجريبية | One unscreened pilot core laid up with the phase and earth cores |
| Earth core | One unscreened earth core laid up with the phase and pilot cores |
| التسديدة السهلة | Three phase cores with composite individual screens, one unscreened pilot core and one unscreened earth core laid up around an elastomeric cradle and in contact with each other |
| أغطية الفراش | Rubber based bedding compound |
| الغلاف الخارجي | Heavy duty chloroprene outer sheath |
| المعلمة | قيمة |
|---|---|
| معيار | BS 6708 |
| الجهد المقنن | 640/1100 فولت |
| جهد الاختبار | 3 كيلو فولت |
| نوع الكابل | Composite individually screened phase cores with unscreened pilot core and unscreened earth core laid up around an elastomeric cradle |
| CORE DIMENSIONS | |||||||
|---|---|---|---|---|---|---|---|
| Nominal cross section | موصل الطور | Phase stranding mm | Cond. dia. mm | Insul. thick. mm | Total screen cross section mm2 | موصل أرضي | Pilot conductor |
| 3x25+2x16 | 3x25 | 196/0.40 | 6.75 | 1.6 | 25.4 | 1x16 | 1x25 |
| 3x35+2x16 | 3x35 | 276/0.40 | 8.00 | 1.6 | 25.4 | 1x16 | 1x35 |
| 3x50+2x25 | 3x50 | 396/0.40 | 9.75 | 1.7 | 33 | 1x25 | 1x50 |
| 3x70+2x35 | 3x70 | 360/0.50 | 11.60 | 1.8 | 35 | 1x35 | 1x70 |
| 3x95+2x50 | 3x95 | 475/0.50 | 12.75 | 2.0 | 53 | 1x50 | 1x95 |
| PILOT CORE DETAILS | ||||
|---|---|---|---|---|
| Nominal cross section | Pilot conductor | Pilot stranding mm | Pilot cond. dia. mm | Pilot insul. thick. mm |
| 3x25+2x16 | 1x25 | 196/0.40 | 6.75 | 1.5 |
| 3x35+2x16 | 1x35 | 276/0.40 | 8.00 | 1.5 |
| 3x50+2x25 | 1x50 | 396/0.40 | 9.75 | 1.6 |
| 3x70+2x35 | 1x70 | 360/0.50 | 11.60 | 1.6 |
| 3x95+2x50 | 1x95 | 475/0.50 | 12.75 | 1.7 |
| CABLE DETAILS | |||||||
|---|---|---|---|---|---|---|---|
| Nominal cross section | Min. OD mm | Max. OD mm | Min. bend radius mm | Outer sheath radial thick. mm | Max pulling tension kgf | Approx. weight kg/km | Copper weight kg/km |
| 3x25+2x16 | 43.2 | 46.6 | 420 | 5.0 | 638 | 3550 | 1307 |
| 3x35+2x16 | 47.3 | 50.7 | 457 | 5.2 | 729 | 4280 | 1675 |
| 3x50+2x25 | 53.7 | 57.6 | 519 | 5.7 | 910 | 5650 | 2340 |
| 3x70+2x35 | 61.2 | 65.0 | 585 | 6.3 | 1148 | 7520 | 3228 |
| 3x95+2x50 | 69.3 | 73.9 | 666 | 7.0 | 1446 | 9800 | 4326 |
| CURRENT RATINGS | ||
|---|---|---|
| Nominal cross section | Continuous current rating at 25 deg C | Short circuit current for 1 s |
| 3x25+2x16 | 110 | 3450 |
| 3x35+2x16 | 135 | 3450 |
| 3x50+2x25 | 170 | 4550 |
| 3x70+2x35 | 205 | 4820 |
| 3x95+2x50 | 250 | 7300 |
| ELECTRICAL DETAILS | |||
|---|---|---|---|
| Nominal Bcross section | Phase and earth conductors DC res. at 20 deg C ohm/km | Pilot conductor DC res.X at 20 deg C ohm/km | 3 screens in parallel connection ohm/km |
| 3x25+2x16 | 0.795 | 1.240 | 1.10 |
| 3x35+2x16 | 0.565 | 1.240 | 1.20 |
| 3x50+2x25 | 0.393 | 0.795 | 1.40 |
| 3x70+2x35 | 0.277 | 0.565 | 0.70 |
| 3x95+2x50 | 0.210 | 0.393 | 0.85 |
Use the table values with the equipment drawing and approved termination plan. If the requested conductor area, current basis, mechanical limit or environmental condition is not listed in the supplied PDF, treat it as a quotation-stage confirmation item.
Type 14 standards and references
| الموضوع | Source-linked reference |
|---|---|
| معيار المنتج | BS 6708 |
| الجهد المقنن | 640/1100 فولت |
| جهد الاختبار | 3 كيلو فولت |
| Source application | excavating, crushing and coal-cutting equipment |
The product page preserves the BS 6708 reference appearing in the supplied PDF. The BSI record currently identifies BS 6708:1998 as withdrawn on 22 May 2026; this status note is a standards-reference update, not a claim that the product is currently certified or approved. See the official BSI BS 6708 scope record for the published status.
For an RFQ, state the required standard documents, inspection scope, test report, cable marking, destination rules and any replacement-equivalence requirement. The model number alone does not establish legal installation compliance.
خيارات الكابلات ذات الصلة
قارن بين خيارات الكابلات هذه حسب مجموعة الخدمات، والحركة، والحمل، والجهد، ومتطلبات الإرسال.
كابل منجم فحم تحت الأرض من النوع 240، من 1.1 كيلو فولت إلى 11 كيلو فولت
خيار كابل ذي صلة لتطبيق أو وظيفة مختلفة.
عرض المنتجكابل تعدين من النوع 241.1 بجهد 1.1 كيلو فولت | عائلة النوع 241
خيار كابل ذي صلة لتطبيق أو وظيفة مختلفة.
عرض المنتجاطلب توصية بشأن الكابلات وعرض سعر
يرجى إرسال الخدمات المطلوبة، وطول الكابل، والقدرات الميكانيكية، والبيئة، ونوع التوصيلات، والكمية. سيقوم فريقنا بمراجعة الطلب قبل تقديم عرض السعر.
- يرجى تضمين اسم المنتج أو رمز المنتج (SKU) بالإضافة إلى طول الكابل المطلوب وكميته.
- أرفق المواصفات أو الرسم أو ورقة البيانات عند توفرها.