احصل على عرض سعر
كابلات التعدين وحفر الأنفاق تيباوفليكس

Type 441 Class 1 Screened Mining Cable 3.3–22 kV

Type 441 Class 1 mining cable covers 3.3–22 kV semiconductive screened service where a flexible, lower-radial Class 1 construction is required.

  • Three XR-EP-90 screened power cores
  • Three elastomer-covered tinned earth cores plus one central extensible pilot
  • Extra-heavy XHD-85-PCP sheath and polyaramid braid
  • Pilot DC resistance limits listed in the datasheet
  • For materials handling, slow reeling and trailing applications
  • +90 °C continuous operating; −25 °C minimum installation

Request a size review using the voltage, area and handling arrangement.

معلومات المنتج
ماركة
تيباوفليكس
نظرة عامة على المنتج

Type 441 Class 1 cable for screened high-voltage mine service

ال Type 441 Class 1 mining cable page covers the 3.3 kV, 6.6 kV, 11 kV and 22 kV variants in the supplied datasheet. It is separate from the Type 441.1 Class 2 1.1 kV product because the class, insulation radial and voltage family are not interchangeable labels. This Class 1 design is presented as a flexible cable for materials handling and slow reeling or trailing where a lower nominal outside diameter and mass are useful selection considerations.

Three tinned-copper power cores are insulated with XR-EP-90 and printed for identification on a black semiconductive elastomer screen. Three elastomer-covered tinned earth cores and one EPR-covered central extensible pilot occupy the interstitial spaces. The extra-heavy XHD-85-PCP sheath includes polyaramid braid reinforcement. The source also lists pilot resistance limits, which should be checked when the pilot function is part of the control circuit.

Start with the equipment voltage, required area and cable-management method. Then compare the relevant table for nominal diameter and mass with the entry and handling system. Current capacity, bend radius, tensile load and travel speed are not supplied and remain quotation-stage checks.

بناء

Type 441 Class 1 screened power-core construction

The Class 1 Type 441 construction is defined by semiconductive screened XR-EP-90 power cores, separate interstitial earth cores and one central pilot. The lower-radial Class 1 layout should not be merged with the Type 441.1 Class 2 construction.

Type 441 Class 1 cable cross-section showing screened power cores, earth cores, pilot and braid
Supplied Type 441 Class 1 cross-section for the 3.3–22 kV screened arrangement.
Construction identified in the supplied datasheet
المعلمةالقيمة المدرجة في المصدر
نوى الطاقةThree tinned copper cores with XR-EP-90 insulation
Power screenBlack semiconductive elastomer screen with printed core identification
لب الأرضThree elastomer-covered tinned earth cores, interstitial
PilotOne EPR-covered central extensible pilot
Pilot resistanceMaximum DC 3 ohm/100 m up to 35 mm²; 2 ohm/100 m above 35 mm²
غمدExtra-heavy XHD-85-PCP with polyaramid braid

The supplied cross-section is shown only in Construction. Use the source technical tables for the variant-specific earth, sheath, diameter and mass values.

التطبيقات

Selecting Type 441 Class 1 for handling duty

The buyer-language addition for this page is the distinction between electrical fit and handling fit: the source describes materials handling and slow reeling/trailing, so the cable-management system must be reviewed with the voltage and size.

  • Materials-handling equipment and mobile mine service identified in the source
  • Slow reeling or trailing routes where the Class 1 radial and mass profile is relevant
  • Equipment using three earth conductors and a central pilot through the termination
  • Compare nominal diameter, mass, entry space, guide layout and the required pilot circuit before approval

The source does not publish a travel speed, bend radius or pulling load. A smaller nominal diameter alone is not evidence that the cable can replace another construction in a live route.

تحديد

Type 441 Class 1 Screened Mining Cable 3.3–22 kV technical data

The dimensional and electrical values below are transcribed from the supplied PDF for Type 441 Class 1 mining cable. The tables are retained by voltage, screen option or construction section as presented in the source. Source ordering codes are included where present in the extracted table; blank source cells are not assigned new values.

Use the relevant area, conductor dimensions, insulation or covering thickness, nominal diameter and mass together. The source does not create a universal current-capacity, bend-radius, pulling-load or travel-speed value for this product.

TYPE 441.3 - 3.3 kV - ELECTRICAL DATA

TYPE 441.3 - 3.3 kV - ELECTRICAL DATA
جزءArea mm2Nom. dia. mmInsul. thick. mmAC res. oh/kmReact. oh/kmVolt drop mV/A.mCap. uF/km
25-441-3257.22.20.9510.1201.660.395
35-441-3358.42.20.6980.1151.230.437
50-441-3509.72.40.5230.1130.9270.450
70-441-37012.02.40.3460.1050.6260.525
95-441-39513.32.40.2710.1000.5000.563
120-441-312015.32.40.2100.09590.4000.628
150-441-315017.22.40.1660.09290.3290.687
185-441-318518.82.40.1370.09060.2840.741
240-441-324021.72.40.1070.08740.2390.833
300-441-330024.32.40.08510.08500.2080.917

TYPE 441.3 - 3.3 kV - EARTH, SHEATH AND MASS

TYPE 441.3 - 3.3 kV - EARTH, SHEATH AND MASS
جزءEarth area each mm2Sheath thick. mmNom. dia. mmApprox mass kg/100m
25-441-35.34.945.9320
35-441-35.35.248.8370
50-441-385.754.4470
70-441-312.56.059.5595
95-441-3166.362.7685
120-441-3206.567.2815
150-441-3276.671.3965
185-441-3326.775.11105
240-441-339.56.981.61350
300-441-3507.087.41620

TYPE 441.6 - 6.6 kV - ELECTRICAL DATA

TYPE 441.6 - 6.6 kV - ELECTRICAL DATA
جزءArea mm2Nom. dia. mmInsul. thick. mmAC res. oh/kmReact. oh/kmVolt drop mV/A.mCap. uF/km
25-441-6257.23.00.9510.1261.660.309
35-441-6358.43.00.6980.1211.230.340
50-441-6509.73.00.5230.1160.9280.375
70-441-67012.03.00.3460.1080.6280.435
95-441-69513.33.00.2710.1030.5020.465
120-441-612015.33.00.2100.09900.4020.518
150-441-615017.23.00.1660.09580.3320.566
185-441-618518.83.00.1370.09340.2870.608
240-441-624021.73.00.1060.08990.2410.682
300-441-630024.33.00.08490.08770.2110.754

TYPE 441.6 - 6.6 kV - EARTH, SHEATH AND MASS

TYPE 441.6 - 6.6 kV - EARTH, SHEATH AND MASS
جزءEarth area each mm2Sheath thick. mmNom. dia. mmApprox mass kg/100m
25-441-65.35.350.2370
35-441-65.35.653.3425
50-441-686.057.6515
70-441-612.56.362.6640
95-441-6166.465.5725
120-441-6206.670.1860
150-441-6276.774.21015
185-441-6326.878.01155
240-441-639.57.084.61410
300-441-6507.190.41680

TYPE 441.11 - 11 kV - ELECTRICAL DATA

TYPE 441.11 - 11 kV - ELECTRICAL DATA
جزءArea mm2Nom. dia. mmInsul. thick. mmAC res. oh/kmReact. oh/kmVolt drop mV/A.mCap. uF/km
25-441-11257.25.00.9510.1371.660.217
35-441-11358.45.00.6980.1311.230.236
50-441-11509.75.00.5230.1240.9310.258
70-441-117012.05.00.3460.1160.6320.296
95-441-119513.35.00.2710.1120.5080.317
120-441-1112015.35.00.2100.1080.4090.350
150-441-1115017.25.00.1660.1040.3390.381
185-441-1118518.85.00.1370.1010.2950.407
240-441-1124021.75.00.1060.09700.2490.453
300-441-1130024.35.00.08460.09420.2190.499

TYPE 441.11 - 11 kV - EARTH, SHEATH AND MASS

TYPE 441.11 - 11 kV - EARTH, SHEATH AND MASS
جزءEarth area each mm2Sheath thick. mmNom. dia. mmApprox mass kg/100m
25-441-115.36.360.9500
35-441-115.36.463.6555
50-441-1186.566.7635
70-441-1112.56.671.6765
95-441-11166.874.8870
120-441-11206.979.31010
150-441-11277.083.61180
185-441-11327.187.21320
240-441-1139.57.393.81585
300-441-11507.5100.01880

TYPE 441.22 - 22 kV - ELECTRICAL DATA

TYPE 441.22 - 22 kV - ELECTRICAL DATA
جزءArea mm2Nom. dia. mmInsul. thick. mmAC res. oh/kmReact. oh/kmVolt drop mV/A.mCap. uF/km
35-441-22358.47.60.6980.1431.230.178
50-441-22509.77.60.5230.1360.9360.194
70-441-227012.07.60.3460.1270.6380.219
95-441-229513.37.60.2710.1230.5150.234
120-441-2212015.37.60.2100.1180.4170.256
150-441-2215017.27.60.1650.1130.3460.276
185-441-2218518.87.60.1360.1100.3030.294
240-441-2224021.77.60.1060.1050.2580.325

TYPE 441.22 - 22 kV - EARTH, SHEATH AND MASS

TYPE 441.22 - 22 kV - EARTH, SHEATH AND MASS
جزءEarth area each mm2Sheath thick. mmNom. dia. mmApprox mass kg/100m
35-441-225.36.976.0750
50-441-2287.079.2840
70-441-2212.57.184.1980
95-441-22167.287.01085
120-441-22207.391.71245
150-441-22277.495.81415
185-441-22327.699.81580
240-441-2239.57.71061850

8 technical tables were transcribed from the supplied datasheet; confirm final selection against the original PDF and project cable schedule.

المعايير

Type 441 Class 1 voltage and standard

The supplied sheet identifies Type 441 Class 1 as a semiconductive screened mining cable to AS/NZS 2802. Its voltage family is recorded below.

Source-listed standard and service limits
المعلمةالقيمة المدرجة في المصدر
معيار المنتجAS/NZS 2802
Voltage range3.3 kV to 22 kV
أقصى درجة حرارة تشغيل مستمرة+90 °C
Minimum installation temperature−25 °C
تثبيتFree air for mobile equipment
Oil / water performanceExcellent immersion performance and very good flexibility
أداء اللهبC1

Use the exact Type 441 Class 1 voltage designation and the required pilot resistance/documentation scope in the RFQ.

قارن حسب الرسوم

خيارات الكابلات ذات الصلة

قارن بين خيارات الكابلات هذه حسب مجموعة الخدمات، والحركة، والحمل، والجهد، ومتطلبات الإرسال.

عرض أسعار قائم على الهندسة

اطلب توصية بشأن الكابلات وعرض سعر

يرجى إرسال الخدمات المطلوبة، وطول الكابل، والقدرات الميكانيكية، والبيئة، ونوع التوصيلات، والكمية. سيقوم فريقنا بمراجعة الطلب قبل تقديم عرض السعر.

  • يرجى تضمين اسم المنتج أو رمز المنتج (SKU) بالإضافة إلى طول الكابل المطلوب وكميته.
  • أرفق المواصفات أو الرسم أو ورقة البيانات عند توفرها.

    اختياري: إرفاق مواصفات الكابل أو الرسم أو ورقة البيانات أو صورة المنتج (PDF، DOC، DOCX، XLS، XLSX، CSV، JPG أو PNG؛ بحد أقصى 10 ميجابايت).

    بإرسال هذا النموذج، فإنك توافق على أن تستخدم شركة TEBAOFLEX معلومات الاتصال والملفات المُقدمة لمراجعة استفسارك والرد عليه. تُستخدم الملفات لإعداد عروض الأسعار والتواصل الهندسي المتعلق بطلبك. راجع سياسة ملفاتنا سياسة الخصوصية للحصول على معلومات حديثة حول معالجة البيانات والاحتفاظ بها.

    * الحقول المطلوبة. يرجى تضمين تفاصيل الكابل الرئيسي أو التطبيق للمراجعة.