UL 3644 Silicone Appliance Wire, 200°C 1000V
UL 3644 is a UL-certified silicone appliance wire rated 1000 V AC, with 150°C and 200°C constructions. It is intended for internal appliance wiring where the wire is totally enclosed, and the required temperature grade should appear on the equipment specification.
- Spannung: 1000 V AC
- Temperatur: 150°C or 200°C by construction
- Isolierung / Umhüllung: extruded silicone rubber
- Größenauswahl: 30 AWG–1000 kcmil style range; table: 30 AWG–4/0 AWG
- Zertifizierung: UL-zertifiziertes AWM; UL 758
UL 3644 wire selection
UL 3644 is a UL-certified silicone appliance wire rated 1000 V AC, with 150°C and 200°C constructions. It is intended for internal appliance wiring where the wire is totally enclosed, and the required temperature grade should appear on the equipment specification.
The dimension table now includes 19 conductor sizes from 30 AWG through 4/0 AWG. The nominal insulation wall changes with conductor size, starting at 0.82 mm for the 30–10 AWG rows. Stranding and finished diameter are shown together, while a separate style thickness schedule covers the wider range up to 1000 kcmil. This separates a finished-wire dimension from the minimum insulation requirement used to define the construction.
When replacing an enclosed appliance lead, check the temperature grade and the available bend space before assuming that another 1 kV silicone wire will fit. The listed constructions use a bend radius of 10 times finished diameter. A different wall schedule can change the terminal entry clearance even when the AWG and voltage rating match.
Modell- und Größentabellen finden Sie auf der Registerkarte „Spezifikationen“. Sehen Sie sich die Kategorie Hochtemperaturkabel-Sortiment for related constructions. Compare UL 3580 for 150°C motor lead duty and UL 3645 when an additional outer covering is specified.
Aufbau
UL 3644 uses the following conductor and insulation system. The diagram illustrates the layer sequence; select the conductor construction and covering shown in the required size specification.

| Bestandteil | Aufbaudetail |
|---|---|
| Leiter | Solid or stranded copper; dimensioned examples are stranded |
| Isolierung | Extrudierter Silikonkautschuk |
Anwendungen
UL 3644 is intended for appliance internal wiring inside a complete enclosure. Select the 150°C or 200°C construction to match the local thermal duty and connection materials.

UL 3644 replacement selection
Geben Sie bei Ersatzanfragen die Kennzeichnung der vorhandenen Leitung und den Anschlussplan des Geräts an, damit Leiter, Isolierung und Klemmenanordnung abgeglichen werden können.
Technische Daten
| Parameter | Spezifikation |
|---|---|
| UL-Stil | UL 3644 |
| Nennspannung | 1000 V AC |
| Temperaturbemessung | 150°C or 200°C by construction |
| Isolierung / Umhüllung | extruded silicone rubber |
| Abgedeckter Leitergrößenbereich | 30 AWG–1000 kcmil style range; table: 30 AWG–4/0 AWG |
| Bending radius for listed construction | 10 × finished OD |
Nominal dimensions follow the listed conductor constructions. Confirm the agreed finished-diameter drawing for tight-clearance assemblies.
| Modell und Leitergröße | Litzenanzahl (Anz./mm) | Nominal silicone wall (mm) | Nenn-Außendurchmesser / Toleranz (mm) |
|---|---|---|---|
| UL 3644 4/0 AWG | 2146/0.254 | 2.09 | 17.77 ±0.15 |
| UL 3644 3/0 AWG | 1615/0.254 | 2.09 | 15.97 ±0.15 |
| UL 3644 2/0 AWG | 1330/0.254 | 2.09 | 14.88 ±0.15 |
| UL 3644 1/0 AWG | 1026/0.254 | 2.09 | 13.58 ±0.15 |
| UL 3644 2 AWG | 665/0.254 | 1.58 | 10.73 ±0.15 |
| UL 3644 4 AWG | 420/0.254 | 1.58 | 9.18 ±0.15 |
| UL 3644 6 AWG | 259/0.254 | 1.58 | 7.89 ±0.15 |
| UL 3644 8 AWG | 161/0.254 | 1.20 | 6.88 ±0.15 |
| UL 3644 10 AWG | 105/0.254 | 0.82 | 4.65 ±0.15 |
| UL 3644 12 AWG | 65/0.254 | 0.82 | 4.01 ±0.15 |
| UL 3644 14 AWG | 41/0.254 | 0.82 | 3.52 ±0.15 |
| UL 3644 16 AWG | 26/0.254 | 0.82 | 3.14 ±0.15 |
| UL 3644 18 AWG | 34/0.18 | 0.82 | 2.86 ±0.15 |
| UL 3644 20 AWG | 21/0.18 | 0.82 | 2.60 ±0.15 |
| UL 3644 22 AWG | 17/0.16 | 0.82 | 2.41 ±0.15 |
| UL 3644 24 AWG | 11/0.16 | 0.82 | 2.26 ±0.15 |
| UL 3644 26 AWG | 7/0.16 | 0.82 | 2.13 ±0.15 |
| UL 3644 28 AWG | 7/0.127 | 0.82 | 2.03 ±0.15 |
| UL 3644 30 AWG | 7/0.10 | 0.82 | 1.95 ±0.15 |
Style construction thicknesses are shown in mils; 1 mil = 0.0254 mm. Nominal finished dimensions are listed separately.
| Model and conductor group | Minimum average silicone wall (mils) | Minimum point wall (mils) |
|---|---|---|
| UL 3644 30–9 AWG | 30 | 27 |
| UL 3644 8 AWG | 45 | 40 |
| UL 3644 7–2 AWG | 60 | 54 |
| UL 3644 1–4/0 AWG | 80 | 72 |
| UL 3644 250–500 kcmil | 95 | 85 |
| UL 3644 501–1000 kcmil | 110 | 99 |
Auswahl der spezifizierten Ausführung
Identify UL 3644, conductor size and 150°C or 200°C grade together. Use the selected row for nominal OD and the appropriate thickness group for construction review.
Normen
TEBAOFLEX UL 3644 wire is UL-certified appliance wiring material.
| Merkmal | Anforderung oder Referenz |
|---|---|
| Zertifizierung | UL-zertifiziertes AWM |
| Stilbezeichnung | UL 3644 |
| Konstruktionsnorm | UL 758 — Verdrahtungsmaterial für Geräte |
| Flammklassifizierung des Stils | Horizontale Flammprüfung |
Geben Sie in der Einkaufsspezifikation den UL-Stil, die Leitergröße sowie Spannungs- und Temperaturklasse an. Fügen Sie der Anfrage die erforderliche Produktkennzeichnung und Zertifizierungsunterlagen bei.
Kabelempfehlung und Angebot anfordern
Senden Sie die benötigten Funktionen, Kabellänge, mechanische Beanspruchung, Umgebung, Anschlussausführung und Menge. Unser Team prüft die Anwendung vor der Angebotserstellung.
- Geben Sie den Produktnamen oder die SKU sowie die benötigte Kabellänge und Menge an.
- Fügen Sie nach Möglichkeit eine Spezifikation, Zeichnung oder ein Datenblatt bei.