UL 3644 Silicone Appliance Wire, 200°C 1000V
UL 3644 is a UL-certified silicone appliance wire rated 1000 V AC, with 150°C and 200°C constructions. It is intended for internal appliance wiring where the wire is totally enclosed, and the required temperature grade should appear on the equipment specification.
- tension: 1000 V AC
- Température: 150°C or 200°C by construction
- Isolation / revêtement : extruded silicone rubber
- Sélection de la taille : 30 AWG–1000 kcmil style range; table: 30 AWG–4/0 AWG
- Certification : AWM certifié UL; UL 758
UL 3644 wire selection
UL 3644 is a UL-certified silicone appliance wire rated 1000 V AC, with 150°C and 200°C constructions. It is intended for internal appliance wiring where the wire is totally enclosed, and the required temperature grade should appear on the equipment specification.
The dimension table now includes 19 conductor sizes from 30 AWG through 4/0 AWG. The nominal insulation wall changes with conductor size, starting at 0.82 mm for the 30–10 AWG rows. Stranding and finished diameter are shown together, while a separate style thickness schedule covers the wider range up to 1000 kcmil. This separates a finished-wire dimension from the minimum insulation requirement used to define the construction.
When replacing an enclosed appliance lead, check the temperature grade and the available bend space before assuming that another 1 kV silicone wire will fit. The listed constructions use a bend radius of 10 times finished diameter. A different wall schedule can change the terminal entry clearance even when the AWG and voltage rating match.
Consultez l’onglet Caractéristiques pour les tableaux de modèles et de calibres. Parcourez la gamme de câbles haute température for related constructions. Compare UL 3580 for 150°C motor lead duty and UL 3645 when an additional outer covering is specified.
Construction
Le fil UL 1056 utilise le système de conducteur et d’isolation indiqué ci-dessous. Le schéma montre l’ordre des couches; choisissez la construction du conducteur et le revêtement prévus dans la spécification du calibre requis.

| Composant | détail de construction |
|---|---|
| Conducteur | Solid or stranded copper; dimensioned examples are stranded |
| Isolation | Caoutchouc silicone extrudé |
Applications
UL 3644 is intended for appliance internal wiring inside a complete enclosure. Select the 150°C or 200°C construction to match the local thermal duty and connection materials.

UL 3644 replacement selection
Pour une demande de remplacement, fournissez le marquage du fil existant et le schéma de raccordement de l’équipement afin de comparer le conducteur, l’isolation et la disposition des bornes.
Caractéristiques techniques
| Paramètre | Spécification |
|---|---|
| Style UL | UL 3644 |
| Tension assignée | 1000 V AC |
| Indice de température | 150°C or 200°C by construction |
| Isolation / revêtement | extruded silicone rubber |
| Plage de calibres du conducteur | 30 AWG–1000 kcmil style range; table: 30 AWG–4/0 AWG |
| Bending radius for listed construction | 10 × finished OD |
Nominal dimensions follow the listed conductor constructions. Confirm the agreed finished-diameter drawing for tight-clearance assemblies.
| Modèle et calibre du conducteur | Brins du conducteur (n°/mm) | Nominal silicone wall (mm) | Diamètre extérieur nominal / tolérance (mm) |
|---|---|---|---|
| UL 3644 4/0 AWG | 2146/0.254 | 2.09 | 17.77 ±0.15 |
| UL 3644 3/0 AWG | 1615/0.254 | 2.09 | 15.97 ±0.15 |
| UL 3644 2/0 AWG | 1330/0.254 | 2.09 | 14.88 ±0.15 |
| UL 3644 1/0 AWG | 1026/0.254 | 2.09 | 13.58 ±0.15 |
| UL 3644 2 AWG | 665/0.254 | 1.58 | 10.73 ±0.15 |
| UL 3644 4 AWG | 420/0.254 | 1.58 | 9.18 ±0.15 |
| UL 3644 6 AWG | 259/0.254 | 1.58 | 7.89 ±0.15 |
| UL 3644 8 AWG | 161/0.254 | 1.20 | 6.88 ±0.15 |
| UL 3644 10 AWG | 105/0.254 | 0.82 | 4.65 ±0.15 |
| UL 3644 12 AWG | 65/0.254 | 0.82 | 4.01 ±0.15 |
| UL 3644 14 AWG | 41/0.254 | 0.82 | 3.52 ±0.15 |
| UL 3644 16 AWG | 26/0.254 | 0.82 | 3.14 ±0.15 |
| UL 3644 18 AWG | 34/0.18 | 0.82 | 2.86 ±0.15 |
| UL 3644 20 AWG | 21/0.18 | 0.82 | 2.60 ±0.15 |
| UL 3644 22 AWG | 17/0.16 | 0.82 | 2.41 ±0.15 |
| UL 3644 24 AWG | 11/0.16 | 0.82 | 2.26 ±0.15 |
| UL 3644 26 AWG | 7/0.16 | 0.82 | 2.13 ±0.15 |
| UL 3644 28 AWG | 7/0.127 | 0.82 | 2.03 ±0.15 |
| UL 3644 30 AWG | 7/0.10 | 0.82 | 1.95 ±0.15 |
Style construction thicknesses are shown in mils; 1 mil = 0.0254 mm. Nominal finished dimensions are listed separately.
| Model and conductor group | Minimum average silicone wall (mils) | Minimum point wall (mils) |
|---|---|---|
| UL 3644 30–9 AWG | 30 | 27 |
| UL 3644 8 AWG | 45 | 40 |
| UL 3644 7–2 AWG | 60 | 54 |
| UL 3644 1–4/0 AWG | 80 | 72 |
| UL 3644 250–500 kcmil | 95 | 85 |
| UL 3644 501–1000 kcmil | 110 | 99 |
Choix de la construction spécifiée
Identify UL 3644, conductor size and 150°C or 200°C grade together. Use the selected row for nominal OD and the appropriate thickness group for construction review.
Normes
TEBAOFLEX UL 3644 wire is UL-certified appliance wiring material.
| Article | Exigence ou référence |
|---|---|
| Certification | AWM certifié UL |
| Désignation du style | UL 3644 |
| Norme de construction | UL 758 — Matériaux de câblage pour appareils |
| Classement au feu du style | Flamme horizontale |
Indiquez le style UL, le calibre du conducteur et les classes de tension et de température dans le cahier des charges. Joignez à la demande l’identification du produit et les documents de certification requis.
Demandez une recommandation et un devis pour un câble.
Veuillez nous indiquer les services requis, la longueur du câble, les contraintes mécaniques, l'environnement, le type de terminaison et la quantité. Notre équipe examinera votre demande avant de vous établir un devis.
- Veuillez inclure le nom du produit ou son SKU, ainsi que la longueur et la quantité de câble requises.
- Joignez une fiche technique, un dessin ou une fiche de spécifications si disponible.