Solicita un presupuesto
CABLES PARA MINERÍA Y TÚNELES TEBAOFLEX

Type 20 / Type 21 BS 6708 640/1100 V Armoured Mining Cable

Type 20 / Type 21 mining cable for excavating and crushing machines and equipment, with the source-defined 640/1100 V rating and 3 kV test reference.

  • Model: Type 20 / Type 21
  • Conductor and insulation: flexible tinned copper with the insulation and core construction listed for this model in the supplied PDF
  • Screen, pilot, earth and armour arrangement preserved from the source datasheet
  • Heavy-duty chloroprene or PCP outer protection as listed for this model
  • Original Type datasheet available as the product download

Send the equipment, voltage, conductor area, route, quantity and document requirements for an RFQ.

Información del producto
Marca
TEBAOFLEX
Descripción general del producto

Type 20 / Type 21 for excavating and crushing machines and equipment

Type 20 / Type 21 mining cable is specified in the supplied BS 6708 datasheet for excavating and crushing machines and equipment. This page keeps the source-listed voltage, test reference, core functions and dimensional tables together so a procurement engineer can compare the requested model against the cable marking and the equipment connection. The editorial focus is the armoured unscreened power path, not a generic promise of performance.

The supplied construction uses three or four unscreened cores laid around an elastomeric cradle without contacting one another, with galvanized steel pliable armour between inner and outer sheaths. That arrangement matters because The core count is the principal distinction: Type 20 is three-core and Type 21 is four-core; neither is an individually screened coal-cutter cable. The family should therefore be selected by model, core function and installation route as well as by voltage. The Gama de cables para minería y túneles provides the wider TEBAOFLEX product context.

  • Elegir por: confirm whether the equipment requires the three-core Type 20 or four-core Type 21 arrangement and check the armour interface.
  • Confirmar antes de realizar el pedido: existing sheath marking, conductor area, cable length, route, support or handling system, terminations and the required inspection documents.
  • Do not infer: values not listed in the supplied PDF, such as a different current basis, water/oil/UV performance, certification scope or mechanical interchangeability.

For model screening around core count and armoured low-voltage routes, consult the BS 6708 mining cable replacement guide before issuing a replacement request.

For a technical quotation, send the equipment nameplate or existing cable marking, voltage and size requirement, installation conditions, quantity, destination and any project-specific test or documentation requirement.

Construcción

Type 20 / Type 21 construction

The cross-section below is the supplied construction drawing for Type 20 / Type 21. The ordering decision is driven by The core count is the principal distinction: Type 20 is three-core and Type 21 is four-core; neither is an individually screened coal-cutter cable.

Type 20 / Type 21 cable cross-section showing the supplied power, pilot, earth, screen and protection arrangement
Supplied Type 20 / Type 21 cross-section; the exact core and armour arrangement must be checked against the product datasheet.

Source-listed construction

Elemento de construcciónValor indicado en la fuente
ConductorElectrolytic stranded tinned copper wire, IEC 60228 Class 5
AislamientoAislamiento EPR
bandejaThree or four unscreened cores laid up around an elastomeric cradle without contacting each other
ArmaduraGalvanized steel pliable armour between inner and outer sheaths
VainaHeavy-duty chloroprene outer sheath
VariantsType 20 three-core; Type 21 four-core

Do not use the drawing as a substitute for the dimensional tables. Confirm the cable end preparation, screen and earth termination, armour bonding and machine interface with the equipment documentation before installation.

Aplicaciones

Type 20 / Type 21 applications

Type 20 / Type 21 mining cable application with surface mining excavator equipment
Media-library application scene showing surface mining excavator equipment; used for application context, not as a model-specific construction proof.

The supplied datasheet identifies this cable for excavating and crushing machines and equipment. Google result patterns for the BS 6708 family also separate cables by equipment duty, voltage class, core function and whether the route is armoured, screened, flat or auxiliary. That is why this page keeps the Type 20 / Type 21 construction separate from nearby Type numbers.

  • Primary duty: excavating and crushing machines and equipment.
  • Model boundary: The core count is the principal distinction: Type 20 is three-core and Type 21 is four-core; neither is an individually screened coal-cutter cable.
  • Project check: match the cable marking, core map, voltage, termination, route geometry and handling method to the machine drawing.
  • Environmental review: confirm the actual mine/quarry conditions and any authority, inspection or documentation requirements; do not infer a certification or material-resistance claim from the model number.

For lower-voltage armoured equipment routes, the Type 70/71 mining cable offers a useful comparison point; verify the voltage class and core requirement before selection.

The cable should be released only after the equipment route, required length, conductor area, core functions and connection details are agreed. If the intended duty is different from the source-listed application, request an engineering review through the quotation process.

Especificaciones

Type 20 / Type 21 specifications

The summary below identifies the supplied model family. The source-transcribed tables that follow retain the PDF's dimensional, electrical and construction values, including available sizes, resistance, current, diameter, mass, bending or pulling data when the PDF provides them.

Selection itemSource-linked value
ModeloType 20 / Type 21
Tensión nominal640/1100 V
Voltaje de prueba3 kV
Aplicaciónexcavating and crushing machines and equipment
Norma del productoBS 6708

Complete source-transcribed technical tables

Source PDF: BS6708_TYPE_20_TYPE_21_640_1100V_ARMOURED_CABLE_datasheet.pdf; 4 pages; 8 extracted tables. Values are not recalculated or replaced by third-party values.

Source table 1, PDF page 1
ParámetroValor
ConductorElectrolytic stranded tinned copper wire, IEC 60228 Class 5
AislamientoAislamiento EPR
bandejaThree or four unscreened cores laid up around an elastomeric cradle without contacting each other
LechoRubber based bedding compound
ArmaduraGalvanized steel pliable armour between inner and outer sheaths
Vaina exteriorHeavy duty chloroprene outer sheath
Source table 2, PDF page 1
ParámetroValor
EstándarBS 6708
Tensión nominal640/1100 V
Voltaje de prueba3 kV
Type 20Three-core unscreened power supply cable with pliable steel armouring
Type 21Four-core unscreened power supply cable with pliable steel armouring
Source table 1, PDF page 2
TYPE 20 CORE DIMENSIONS
Nominal cross sectionStranding mmCond. dia. mmInsul. thick. mm
3x2.550/0.252.101.4
3x456/0.302.701.4
3x684/0.303.301.5
3x1080/0.404.401.5
3x16126/0.405.501.5
3x25196/0.407.101.6
3x35276/0.408.401.6
3x50396/0.4010.101.7
3x70360/0.5011.901.8
3x95475/0.5013.902.0
3x120629/0.5015.802.2
3x150740/0.5017.002.3
Source table 2, PDF page 2
TYPE 21 CORE DIMENSIONS
Nominal cross sectionStranding mmCond. dia. mmInsul. thick. mm
4x2.550/0.252.101.4
4x456/0.302.701.4
4x684/0.303.301.5
4x1080/0.404.401.5
4x16126/0.405.501.5
4x25196/0.407.101.6
4x35276/0.408.401.6
4x50396/0.4010.101.7
4x70360/0.5011.901.8
4x95475/0.5013.902.0
4x120629/0.5015.802.2
4x150740/0.5017.002.3
Source table 1, PDF page 3
TYPE 20 CABLE DETAILS
Nominal cross sectionInner sheath radial thick. mmArmour size mmOuter sheath thick. mmMax. OD mmMin. bend radius mmApprox. weight kg/kmCopper weight kg/km
3x2.52.07/0.452.526.924399072
3x42.07/0.452.528.22541150115
3x62.57/0.713.836.53292000173
3x102.57/0.713.838.43462350288
3x162.57/0.713.840.83682750461
3x252.57/0.904.047.04233350720
3x352.57/0.904.350.645643001008
3x502.57/0.904.756.751153201440
3x702.57/0.905.262.756567502016
3x953.87/0.905.872.164987502736
3x1203.87/0.906.277.0693106503456
3x1505.07/1.256.687.3786125004320
Source table 2, PDF page 3
TYPE 20 ELECTRICAL DETAILS
Nominal cross sectionCurrent rating at 25 deg CPhase and earth conductors DC res. ohm/kmArmour DC res. at 20 deg C ohm/km
3x2.5288.214.6
3x4375.094.2
3x6463.392.2
3x10631.952.0
3x16851.241.9
3x251100.7951.3
3x351350.5651.2
3x501700.3931.1
3x702050.2770.94
3x952500.2100.80
3x1202950.1640.74
3x1503200.1320.45
Source table 1, PDF page 4
TYPE 21 CABLE DETAILS
Nominal cross sectionInner sheath radial thick. mmArmour size mmOuter sheath thick. mmMax. OD mmMin. bend radius mmApprox. weight kg/kmCopper weight kg/km
4x2.52.07/0.452.528.6258115096
4x42.07/0.452.530.12711320154
4x62.57/0.713.838.83502350230
4x102.57/0.713.841.03692740384
4x162.57/0.713.944.03963170614
4x252.57/0.904.349.84494030960
4x352.57/0.904.756.150552201344
4x502.57/0.905.161.855764001920
4x702.57/0.905.771.464380602688
4x953.87/0.906.378.6708106503648
4x1203.87/0.906.889.0801134504608
4x1505.07/1.257.395.3858153005760
Source table 2, PDF page 4
TYPE 21 ELECTRICAL DETAILS
Nominal cross sectionCurrent rating at 25 deg CPhase and earth conductors DC res. ohm/kmArmour DC res. at 20 deg C ohm/km
4x2.5288.214.2
4x4375.093.9
4x6463.392.0
4x10631.951.9
4x16851.241.7
4x251100.7951.5
4x351350.5651.1
4x501700.3930.96
4x702050.2770.80
4x952500.2100.73
4x1202950.1640.47
4x1503200.1320.41

Use the table values with the equipment drawing and approved termination plan. If the requested conductor area, current basis, mechanical limit or environmental condition is not listed in the supplied PDF, treat it as a quotation-stage confirmation item.

Estándares

Type 20 / Type 21 standards and references

TemaSource-linked reference
Norma del productoBS 6708
Tensión nominal640/1100 V
Voltaje de prueba3 kV
Source applicationexcavating and crushing machines and equipment

The product page preserves the BS 6708 reference appearing in the supplied PDF. The BSI record currently identifies BS 6708:1998 as withdrawn on 22 May 2026; this status note is a standards-reference update, not a claim that the product is currently certified or approved. See the official BSI BS 6708 scope record for the published status.

For an RFQ, state the required standard documents, inspection scope, test report, cable marking, destination rules and any replacement-equivalence requirement. The model number alone does not establish legal installation compliance.

Comparar por impuesto

Opciones de cable relacionadas

Compare estas opciones de cable según la combinación de servicios, el movimiento, la carga, el voltaje y los requisitos de transmisión.

Cotización basada en ingeniería

Solicite una recomendación y un presupuesto de cables.

Indique los servicios requeridos, la longitud del cable, la carga mecánica, el entorno, el tipo de terminación y la cantidad. Nuestro equipo revisará la solicitud antes de elaborar un presupuesto.

  • Incluya el nombre del producto o SKU, así como la longitud y la cantidad de cable requeridas.
  • Adjunte una especificación, un dibujo o una hoja de datos cuando esté disponible.

    Opcional: adjunte una especificación del cable, un dibujo, una hoja de datos o una imagen del producto (PDF, DOC, DOCX, XLS, XLSX, CSV, JPG o PNG; máximo 10 MB).

    Al enviar este formulario, usted acepta que TEBAOFLEX pueda utilizar la información de contacto y los archivos proporcionados para revisar y responder a su consulta. Los archivos se utilizan para la cotización y la comunicación técnica relacionada con su solicitud. Consulte nuestra política de privacidad para obtener información actualizada sobre el manejo y la retención de datos.

    * Campos obligatorios. Incluya el cable clave o los detalles de la aplicación para su revisión.