Type 441.1 Class 2 Screened Mining Cable 1.1/1.1 kV
Type 441.1 Class 2 mining cable is a 1.1/1.1 kV semiconductive screened cable for general mine use outside underground coal applications.
- Three tinned-copper power cores, three interstitial earth cores and one central pilot
- Class 2 EPR R-EP-90 insulation with semiconductive layer
- Semiconductive cradle and bedding
- Open-weave braid reinforcement and heavy-duty elastomer sheath
- 4.2 kV test voltage listed in the source
- +90 °C maximum continuous; −25 °C minimum installation
Confirm conductor area, route and termination configuration before ordering.
Type 441.1 Class 2 mining cable for 1.1 kV service
Type 441.1 Class 2 mining cable is a 1.1/1.1 kV screened cable for general mine use outside underground coal-mine applications, according to the supplied datasheet. It is a focused low-voltage product page rather than a catch-all Type 441 listing: the source gives one voltage designation, one Class 2 construction and its own area, diameter and mass tables.
The construction combines three flexible tinned-copper power cores, three interstitial earth cores and one central pilot. Power-core insulation is Class 2 EPR R-EP-90 with a semiconductive layer; the cores are laid over a semiconductive cradle. The earth cores are not insulated, and the assembly is completed by semiconductive elastomer bedding, an open-weave reinforcing braid and a heavy-duty elastomer outer sheath.
Selection should start with the 1.1 kV machine supply and the required conductor area, then move to the cable-entry, support and handling conditions. The datasheet records a 4.2 kV test voltage, but it does not provide current capacity, bend radius, pulling load or travel speed. Those details belong in the equipment-specific RFQ.
Type 441.1 Class 2 screened arrangement
This Type 441.1 variant uses a compact screened assembly with three power cores, interstitial earth cores and one central extensible pilot. The Class 2 designation and 1.1/1.1 kV rating should remain visible in every size cross-reference.

| Parámetro | Valor indicado en la fuente |
|---|---|
| Conductor | Tinned copper rope lay to AS/NZS 1125-2.10 |
| Power insulation | Class 2 EPR R-EP-90 to AS/NZS 3808 |
| Power screening | Semiconductive layer over power-core insulation |
| núcleos terrestres | Three interstitial earth cores; not insulated |
| Pilot | One central pilot |
| Reforzamiento | Open-weave braid |
| Vaina | Heavy-duty elastomer outer sheath |
The supplied cross-section is placed here because the earth-core and pilot positions are part of the product identity. Termination and screening continuity must be checked against the machine design.
Type 441.1 Class 2 application boundary
The source describes Type 441.1 for general use in mines except underground coal mines, where screened cores and reinforcement are required. That boundary is important when this 1.1 kV product is compared with other mine-feeder families.
- General mine installations outside underground coal-mine service
- Underground or open mines needing screened cores and reinforcement, as stated in the source
- Mobile equipment cable routes where a three-earth/one-pilot arrangement is specified
- Confirm the machine voltage, cable-entry space, screening termination and mechanical handling before substitution
The sheet does not state water, oil or UV ratings or a minimum bending radius. Do not turn the application description into a broader environmental or mechanical guarantee.
Type 441.1 Class 2 Screened Mining Cable 1.1/1.1 kV technical data
The dimensional and electrical values below are transcribed from the supplied PDF for Type 441.1 Class 2 mining cable. The tables are retained by voltage, screen option or construction section as presented in the source. Source ordering codes are included where present in the extracted table; blank source cells are not assigned new values.
Use the relevant area, conductor dimensions, insulation or covering thickness, nominal diameter and mass together. The source does not create a universal current-capacity, bend-radius, pulling-load or travel-speed value for this product.
TYPE 441.1 - 1.1/1.1 kV CLASS 2 - POWER, EARTH AND PILOT CORES
| Cross section mm2 | Conductor strand no/mm | Conductor dia. mm | Insul. thick. mm | Insul. dia. mm | Earth strand no/mm | Earth section mm2 | Semi-cond. cover mm | Pilot strand no/mm | Pilot insul. mm |
|---|---|---|---|---|---|---|---|---|---|
| 6 | 84/0.30 | 3.4 | 1.5 | 6.5 | 30/0.30 | 2.2 | 0.8 | 24/0.20 | 0.8 |
| 10 | 77/0.40 | 4.6 | 1.5 | 7.7 | 48/0.30 | 3.4 | 0.8 | 24/0.20 | 0.8 |
| 16 | 126/0.40 | 5.7 | 1.6 | 9 | 75/0.30 | 5.3 | 1.0 | 24/0.20 | 0.8 |
| 25 | 209/0.40 | 7.2 | 1.6 | 10.5 | 75/0.30 | 5.3 | 1.0 | 24/0.20 | 0.8 |
| 35 | 285/0.40 | 8.5 | 1.6 | 11.8 | 75/0.30 | 5.3 | 1.0 | 24/0.20 | 0.8 |
| 50 | 380/0.40 | 10 | 1.7 | 13.5 | 114/0.30 | 8.1 | 1.0 | 40/0.20 | 0.8 |
| 70 | 203/0.67 | 12 | 1.8 | 16 | 36/0.67 | 12.7 | 1.0 | 40/0.20 | 0.8 |
| 95 | 259/0.67 | 13.2 | 2.0 | 17.6 | 45/0.67 | 15.9 | 1.0 | 40/0.20 | 0.8 |
| 120 | 336/0.67 | 15.3 | 2.1 | 20 | 57/0.67 | 20.1 | 1.0 | 40/0.20 | 0.8 |
| 150 | 427/0.67 | 17.1 | 2.3 | 22.2 | 77/0.67 | 27.2 | 1.2 | 40/0.20 | 0.8 |
| 185 | 518/0.67 | 19.2 | 2.5 | 24.7 | 91/0.67 | 32.1 | 1.2 | 40/0.20 | 0.8 |
| 240 | 672/0.67 | 21.8 | 2.8 | 27.9 | 112/0.67 | 39.5 | 1.2 | 40/0.20 | 0.8 |
| 300 | 854/0.67 | 24.4 | 3.0 | 30.9 | 144/0.67 | 50.8 | 1.4 | 40/0.20 | 0.8 |
TYPE 441.1 - SHEATH AND MASS
| Cross section mm2 | Sheath thick. mm | Overall dia. mm | Cable mass kg/km | Copper mass kg/km |
|---|---|---|---|---|
| 6 | 3.8 | 28.5 | 1100 | 244 |
| 10 | 3.8 | 31.1 | 1350 | 394 |
| 16 | 3.9 | 34.1 | 1750 | 621 |
| 25 | 4.2 | 37.9 | 2300 | 885 |
| 35 | 4.4 | 41.2 | 2750 | 1173 |
| 50 | 4.9 | 45.9 | 3500 | 1686 |
| 70 | 5.3 | 52.2 | 4800 | 2394 |
| 95 | 5.8 | 56.7 | 5800 | 3206 |
| 120 | 6.3 | 62.7 | 7250 | 4047 |
| 150 | 6.7 | 68.3 | 8800 | 5116 |
| 185 | 7.3 | 74.9 | 10500 | 6265 |
| 240 | 8.0 | 83.3 | 13300 | 8062 |
| 300 | 8.7 | 91.2 | 16300 | 10116 |
2 technical tables were transcribed from the supplied datasheet; confirm final selection against the original PDF and project cable schedule.
Type 441.1 Class 2 source references
This product is kept separate from the higher-voltage Type 441 Class 1 page because the source documents define different classes and voltage ranges.
| Parámetro | Valor indicado en la fuente |
|---|---|
| Norma del producto | AS/NZS 2802 |
| Tensión nominal | 1,1/1,1 kV |
| Voltaje de prueba | 4,2 kV |
| Temperatura máxima de funcionamiento continuo | +90 °C |
| Minimum installation temperature | −25 °C |
| Disposición central | 3 phase + 3 interstitial earth + 1 central pilot |
Reference the exact Type 441.1 Class 2 designation in the RFQ and request the applicable inspection or test documentation with the cable schedule.
Opciones de cable relacionadas
Compare estas opciones de cable según la combinación de servicios, el movimiento, la carga, el voltaje y los requisitos de transmisión.
Cable subterráneo para minas de carbón tipo 240 de 1,1 kV a 11 kV
Una opción de cable relacionada para una aplicación o perfil de trabajo diferente.
Ver productoCable minero tipo 241.1 de 1,1 kV | Familia tipo 241
Una opción de cable relacionada para una aplicación o perfil de trabajo diferente.
Ver productoCable de alimentación blindado para minería TIPO 260
Una opción de cable relacionada para una aplicación o perfil de trabajo diferente.
Ver productoSolicite una recomendación y un presupuesto de cables.
Indique los servicios requeridos, la longitud del cable, la carga mecánica, el entorno, el tipo de terminación y la cantidad. Nuestro equipo revisará la solicitud antes de elaborar un presupuesto.
- Incluya el nombre del producto o SKU, así como la longitud y la cantidad de cable requeridas.
- Adjunte una especificación, un dibujo o una hoja de datos cuando esté disponible.