Obtenir un devis
CÂBLES MINIERS ET DE TUNNELAGE Modèle / construction

Type 441.1 Class 2 Screened Mining Cable 1.1/1.1 kV

Type 441.1 Class 2 mining cable is a 1.1/1.1 kV semiconductive screened cable for general mine use outside underground coal applications.

  • Three tinned-copper power cores, three interstitial earth cores and one central pilot
  • Class 2 EPR R-EP-90 insulation with semiconductive layer
  • Semiconductive cradle and bedding
  • Open-weave braid reinforcement and heavy-duty elastomer sheath
  • 4.2 kV test voltage listed in the source
  • +90 °C maximum continuous; −25 °C minimum installation

Confirm conductor area, route and termination configuration before ordering.

Informations sur le produit
Marque
Modèle / construction
Présentation du produit

Type 441.1 Class 2 mining cable for 1.1 kV service

Type 441.1 Class 2 mining cable is a 1.1/1.1 kV screened cable for general mine use outside underground coal-mine applications, according to the supplied datasheet. It is a focused low-voltage product page rather than a catch-all Type 441 listing: the source gives one voltage designation, one Class 2 construction and its own area, diameter and mass tables.

The construction combines three flexible tinned-copper power cores, three interstitial earth cores and one central pilot. Power-core insulation is Class 2 EPR R-EP-90 with a semiconductive layer; the cores are laid over a semiconductive cradle. The earth cores are not insulated, and the assembly is completed by semiconductive elastomer bedding, an open-weave reinforcing braid and a heavy-duty elastomer outer sheath.

Selection should start with the 1.1 kV machine supply and the required conductor area, then move to the cable-entry, support and handling conditions. The datasheet records a 4.2 kV test voltage, but it does not provide current capacity, bend radius, pulling load or travel speed. Those details belong in the equipment-specific RFQ.

Construction

Type 441.1 Class 2 screened arrangement

This Type 441.1 variant uses a compact screened assembly with three power cores, interstitial earth cores and one central extensible pilot. The Class 2 designation and 1.1/1.1 kV rating should remain visible in every size cross-reference.

Type 441.1 Class 2 cable cross-section showing power cores, earth cores, pilot and braid
Supplied Type 441.1 Class 2 cross-section with the screened power, earth and pilot arrangement.
Construction identified in the supplied datasheet
ParamètreValeur indiquée dans la source
ConducteurTinned copper rope lay to AS/NZS 1125-2.10
Power insulationClass 2 EPR R-EP-90 to AS/NZS 3808
Power screeningSemiconductive layer over power-core insulation
noyaux terrestresThree interstitial earth cores; not insulated
PilotOne central pilot
RenforcementOpen-weave braid
GaineHeavy-duty elastomer outer sheath

The supplied cross-section is placed here because the earth-core and pilot positions are part of the product identity. Termination and screening continuity must be checked against the machine design.

Applications

Type 441.1 Class 2 application boundary

The source describes Type 441.1 for general use in mines except underground coal mines, where screened cores and reinforcement are required. That boundary is important when this 1.1 kV product is compared with other mine-feeder families.

  • General mine installations outside underground coal-mine service
  • Underground or open mines needing screened cores and reinforcement, as stated in the source
  • Mobile equipment cable routes where a three-earth/one-pilot arrangement is specified
  • Confirm the machine voltage, cable-entry space, screening termination and mechanical handling before substitution

The sheet does not state water, oil or UV ratings or a minimum bending radius. Do not turn the application description into a broader environmental or mechanical guarantee.

Caractéristiques

Type 441.1 Class 2 Screened Mining Cable 1.1/1.1 kV technical data

The dimensional and electrical values below are transcribed from the supplied PDF for Type 441.1 Class 2 mining cable. The tables are retained by voltage, screen option or construction section as presented in the source. Source ordering codes are included where present in the extracted table; blank source cells are not assigned new values.

Use the relevant area, conductor dimensions, insulation or covering thickness, nominal diameter and mass together. The source does not create a universal current-capacity, bend-radius, pulling-load or travel-speed value for this product.

TYPE 441.1 - 1.1/1.1 kV CLASS 2 - POWER, EARTH AND PILOT CORES

TYPE 441.1 - 1.1/1.1 kV CLASS 2 - POWER, EARTH AND PILOT CORES
Cross section mm2Conductor strand no/mmConductor dia. mmInsul. thick. mmInsul. dia. mmEarth strand no/mmEarth section mm2Semi-cond. cover mmPilot strand no/mmPilot insul. mm
684/0.303.41.56.530/0.302.20.824/0.200.8
1077/0.404.61.57.748/0.303.40.824/0.200.8
16126/0.405.71.6975/0.305.31.024/0.200.8
25209/0.407.21.610.575/0.305.31.024/0.200.8
35285/0.408.51.611.875/0.305.31.024/0.200.8
50380/0.40101.713.5114/0.308.11.040/0.200.8
70203/0.67121.81636/0.6712.71.040/0.200.8
95259/0.6713.22.017.645/0.6715.91.040/0.200.8
120336/0.6715.32.12057/0.6720.11.040/0.200.8
150427/0.6717.12.322.277/0.6727.21.240/0.200.8
185518/0.6719.22.524.791/0.6732.11.240/0.200.8
240672/0.6721.82.827.9112/0.6739.51.240/0.200.8
300854/0.6724.43.030.9144/0.6750.81.440/0.200.8

TYPE 441.1 - SHEATH AND MASS

TYPE 441.1 - SHEATH AND MASS
Cross section mm2Sheath thick. mmOverall dia. mmCable mass kg/kmCopper mass kg/km
63.828.51100244
103.831.11350394
163.934.11750621
254.237.92300885
354.441.227501173
504.945.935001686
705.352.248002394
955.856.758003206
1206.362.772504047
1506.768.388005116
1857.374.9105006265
2408.083.3133008062
3008.791.21630010116

2 technical tables were transcribed from the supplied datasheet; confirm final selection against the original PDF and project cable schedule.

Normes

Type 441.1 Class 2 source references

This product is kept separate from the higher-voltage Type 441 Class 1 page because the source documents define different classes and voltage ranges.

Source-listed standard and service limits
ParamètreValeur indiquée dans la source
Norme du produitAS/NZS 2802
Tension nominale1,1/1,1 kV
Tension d'essai4,2 kV
température de fonctionnement continue maximale+90 °C
Minimum installation temperature−25 °C
Agencement de base3 phase + 3 interstitial earth + 1 central pilot

Reference the exact Type 441.1 Class 2 designation in the RFQ and request the applicable inspection or test documentation with the cable schedule.

Comparer par fonction

Options de câbles associées

Comparez ces options de câbles en fonction de la combinaison de services, du mouvement, de la charge, de la tension et des exigences de transmission.

devis basé sur l'ingénierie

Demandez une recommandation et un devis pour un câble.

Veuillez nous indiquer les services requis, la longueur du câble, les contraintes mécaniques, l'environnement, le type de terminaison et la quantité. Notre équipe examinera votre demande avant de vous établir un devis.

  • Veuillez inclure le nom du produit ou son SKU, ainsi que la longueur et la quantité de câble requises.
  • Joignez une fiche technique, un dessin ou une fiche de spécifications si disponible.

    Facultatif : joindre une spécification de câble, un dessin, une fiche technique ou une image du produit (PDF, DOC, DOCX, XLS, XLSX, CSV, JPG ou PNG ; maximum 10 Mo).

    En soumettant ce formulaire, vous acceptez que TEBAOFLEX utilise vos coordonnées et les fichiers fournis pour examiner votre demande et y répondre. Les fichiers servent à l'établissement du devis et aux échanges techniques relatifs à votre demande. Consultez notre politique de confidentialité. politique de confidentialité pour obtenir des informations à jour sur le traitement et la conservation des données.

    * Champs obligatoires. Veuillez inclure les détails du câble principal ou de l'application pour examen.