UL 3257 Silicone Ignition Wire, 250°C 10kV AC / 25kV DC
UL 3257 is a UL-certified silicone ignition wire rated 250°C, 10 kV AC and 25 kV DC. The stranded nickel-plated copper construction is intended for internal high-voltage leads, with separate voltage ratings for AC and DC circuits.
- Napięcie: 10 kV AC / 25 kV DC
- Temperatura: 250°C
- Izolacja / powłoka: extruded silicone rubber
- Dobór przekroju: 22–12 AWG
- Certyfikacja: AWM z certyfikatem UL; UL 758
UL 3257 wire selection
UL 3257 is a UL-certified silicone ignition wire rated 250°C, 10 kV AC and 25 kV DC. The stranded nickel-plated copper construction is intended for internal high-voltage leads, with separate voltage ratings for AC and DC circuits.
Two silicone wall options are listed across 22–12 AWG: 5/64 in and 7/64 in. The larger wall increases the finished diameter, weight and minimum bend radius even when the conductor size stays the same. The two complete tables make that difference visible, so an ignition lead can be selected against the terminal boot, entry opening and available bend space rather than by AWG alone.
For burner or oven ignition assemblies, record the waveform and operating voltage before choosing the construction. Protect the lead from repeated flexing and use terminations that suit the full voltage and temperature duty. The silicone construction is not intended for immersion. Where a thicker wall is requested, make sure the assembly drawing also allows the larger outside diameter and bend radius.
Tabele modeli i rozmiarów znajdują się w zakładce Specyfikacja. Przejrzyj kategorię gamę kabli wysokotemperaturowych for related constructions. Compare the construction of przewód silikonowy wysokiego napięcia when the duty is a high-voltage equipment lead rather than an igniter.
Budowa
UL 3257 uses the following conductor and insulation system. The diagram illustrates the layer sequence; select the conductor construction and covering shown in the required size specification.

| Element | Szczegóły budowy |
|---|---|
| Żyła przewodząca | Stranded 2% nickel-plated copper |
| Izolacja | Wytłaczana guma silikonowa |
| Wall options | 5/64 in standard or 7/64 in thicker wall |
Zastosowania
UL 3257 suits internal ignition and high-voltage lead connections in burners, ovens and related equipment. The wire must be installed without flexing in service, with terminal insulation and clearances appropriate to the circuit.

UL 3257 replacement selection
Przy zapytaniu o zamiennik podaj oznaczenie dotychczasowego przewodu i rysunek połączeń urządzenia, aby można było dopasować żyłę, izolację i układ zacisków.
Dane techniczne
| Parametr | Specyfikacja |
|---|---|
| Styl UL | UL 3257 |
| Napięcie znamionowe | 10 kV AC / 25 kV DC |
| Klasa temperaturowa | 250°C |
| Izolacja / warstwa ochronna | extruded silicone rubber |
| Zakres rozmiarów żył | 22–12 AWG |
| AC voltage rating | 10,000 V AC |
| DC voltage rating | 25,000 V DC |
| Minimum average / point silicone wall | 78 / 70 mils |
| Temperature range in supplied construction | −60°C to 250°C |
| Instalacja | Internal wiring without flexing; not for immersion |
| Model, size and silicone wall | Druciki | OD (mm) | OD (in) | Masa (kg/km) | Weight (lb/1000 ft) | Min. promień gięcia (in) |
|---|---|---|---|---|---|---|
| UL 3257 22 AWG — 5/64 in | 7 | 4.83 | 0.190 | 26.52 | 18 | 1.52 |
| UL 3257 20 AWG — 5/64 in | 7 | 5.00 | 0.197 | 29.41 | 20 | 1.58 |
| UL 3257 18 AWG — 5/64 in | 19 | 5.18 | 0.204 | 33.38 | 22 | 1.63 |
| UL 3257 16 AWG — 5/64 in | 26 | 5.51 | 0.217 | 40.73 | 27 | 1.74 |
| UL 3257 14 AWG — 5/64 in | 41 | 5.89 | 0.232 | 50.85 | 34 | 1.86 |
| UL 3257 12 AWG — 5/64 in | 65 | 6.35 | 0.250 | 66.58 | 45 | 2.00 |
| Model, size and silicone wall | Druciki | OD (mm) | OD (in) | Masa (kg/km) | Weight (lb/1000 ft) | Min. promień gięcia (in) |
|---|---|---|---|---|---|---|
| UL 3257 22 AWG — 7/64 in | 7 | 6.45 | 0.254 | 45.26 | 30 | 2.03 |
| UL 3257 20 AWG — 7/64 in | 7 | 6.63 | 0.261 | 48.70 | 33 | 2.09 |
| UL 3257 18 AWG — 7/64 in | 19 | 6.81 | 0.268 | 53.26 | 36 | 2.14 |
| UL 3257 16 AWG — 7/64 in | 26 | 7.14 | 0.281 | 61.69 | 41 | 2.25 |
| UL 3257 14 AWG — 7/64 in | 41 | 7.52 | 0.296 | 73.09 | 49 | 2.37 |
| UL 3257 12 AWG — 7/64 in | 65 | 7.98 | 0.314 | 90.40 | 61 | 2.51 |
Dobór wymaganej konstrukcji
Use UL 3257 plus AWG and wall option on the order. State 10 kV AC or 25 kV DC duty explicitly and compare the corresponding OD and minimum bend radius before choosing a boot or gland.
Normy
TEBAOFLEX UL 3257 wire is UL-certified appliance wiring material.
| Pozycja | Wymaganie lub odniesienie |
|---|---|
| Certyfikacja | AWM z certyfikatem UL |
| Oznaczenie stylu | UL 3257 |
| Norma konstrukcyjna | UL 758 — Materiały do okablowania urządzeń |
| Klasyfikacja palności stylu | Pozioma próba płomieniowa |
W specyfikacji zakupowej podaj styl UL, rozmiar żyły oraz klasę napięciową i temperaturową. Do zapytania dołącz wymaganą identyfikację produktu i dokumenty certyfikacyjne.
Poproś o dobór kabla i wycenę
Prześlij wymagane funkcje, długość kabla, warunki pracy mechanicznej, środowisko, zakończenia i ilość. Nasz zespół przeanalizuje zastosowanie przed przygotowaniem wyceny.
- Podaj nazwę produktu lub SKU oraz wymaganą długość kabla i ilość.
- Jeśli są dostępne, dołącz specyfikację, rysunek lub kartę katalogową.