UL 3257 Silicone Ignition Wire, 250°C 10kV AC / 25kV DC
UL 3257 is a UL-certified silicone ignition wire rated 250°C, 10 kV AC and 25 kV DC. The stranded nickel-plated copper construction is intended for internal high-voltage leads, with separate voltage ratings for AC and DC circuits.
- Spannung: 10 kV AC / 25 kV DC
- Temperatur: 250°C
- Isolierung / Umhüllung: extruded silicone rubber
- Größenauswahl: 22–12 AWG
- Zertifizierung: UL-zertifiziertes AWM; UL 758
UL 3257 wire selection
UL 3257 is a UL-certified silicone ignition wire rated 250°C, 10 kV AC and 25 kV DC. The stranded nickel-plated copper construction is intended for internal high-voltage leads, with separate voltage ratings for AC and DC circuits.
Two silicone wall options are listed across 22–12 AWG: 5/64 in and 7/64 in. The larger wall increases the finished diameter, weight and minimum bend radius even when the conductor size stays the same. The two complete tables make that difference visible, so an ignition lead can be selected against the terminal boot, entry opening and available bend space rather than by AWG alone.
For burner or oven ignition assemblies, record the waveform and operating voltage before choosing the construction. Protect the lead from repeated flexing and use terminations that suit the full voltage and temperature duty. The silicone construction is not intended for immersion. Where a thicker wall is requested, make sure the assembly drawing also allows the larger outside diameter and bend radius.
Modell- und Größentabellen finden Sie auf der Registerkarte „Spezifikationen“. Sehen Sie sich die Kategorie Hochtemperaturkabel-Sortiment for related constructions. Compare the construction of Hochspannungs-Silikonkabel when the duty is a high-voltage equipment lead rather than an igniter.
Aufbau
UL 3257 uses the following conductor and insulation system. The diagram illustrates the layer sequence; select the conductor construction and covering shown in the required size specification.

| Bestandteil | Aufbaudetail |
|---|---|
| Leiter | Stranded 2% nickel-plated copper |
| Isolierung | Extrudierter Silikonkautschuk |
| Wall options | 5/64 in standard or 7/64 in thicker wall |
Anwendungen
UL 3257 suits internal ignition and high-voltage lead connections in burners, ovens and related equipment. The wire must be installed without flexing in service, with terminal insulation and clearances appropriate to the circuit.

UL 3257 replacement selection
Geben Sie bei Ersatzanfragen die Kennzeichnung der vorhandenen Leitung und den Anschlussplan des Geräts an, damit Leiter, Isolierung und Klemmenanordnung abgeglichen werden können.
Technische Daten
| Parameter | Spezifikation |
|---|---|
| UL-Stil | UL 3257 |
| Nennspannung | 10 kV AC / 25 kV DC |
| Temperaturbemessung | 250°C |
| Isolierung / Umhüllung | extruded silicone rubber |
| Abgedeckter Leitergrößenbereich | 22–12 AWG |
| AC voltage rating | 10,000 V AC |
| DC voltage rating | 25,000 V DC |
| Minimum average / point silicone wall | 78 / 70 mils |
| Temperature range in supplied construction | −60°C to 250°C |
| Installation | Internal wiring without flexing; not for immersion |
| Model, size and silicone wall | Einzeldrähte | OD (mm) | OD (in) | Gewicht (kg/km) | Weight (lb/1000 ft) | Mindestbiegeradius (in) |
|---|---|---|---|---|---|---|
| UL 3257 22 AWG — 5/64 in | 7 | 4.83 | 0.190 | 26.52 | 18 | 1.52 |
| UL 3257 20 AWG — 5/64 in | 7 | 5.00 | 0.197 | 29.41 | 20 | 1.58 |
| UL 3257 18 AWG — 5/64 in | 19 | 5.18 | 0.204 | 33.38 | 22 | 1.63 |
| UL 3257 16 AWG — 5/64 in | 26 | 5.51 | 0.217 | 40.73 | 27 | 1.74 |
| UL 3257 14 AWG — 5/64 in | 41 | 5.89 | 0.232 | 50.85 | 34 | 1.86 |
| UL 3257 12 AWG — 5/64 in | 65 | 6.35 | 0.250 | 66.58 | 45 | 2.00 |
| Model, size and silicone wall | Einzeldrähte | OD (mm) | OD (in) | Gewicht (kg/km) | Weight (lb/1000 ft) | Mindestbiegeradius (in) |
|---|---|---|---|---|---|---|
| UL 3257 22 AWG — 7/64 in | 7 | 6.45 | 0.254 | 45.26 | 30 | 2.03 |
| UL 3257 20 AWG — 7/64 in | 7 | 6.63 | 0.261 | 48.70 | 33 | 2.09 |
| UL 3257 18 AWG — 7/64 in | 19 | 6.81 | 0.268 | 53.26 | 36 | 2.14 |
| UL 3257 16 AWG — 7/64 in | 26 | 7.14 | 0.281 | 61.69 | 41 | 2.25 |
| UL 3257 14 AWG — 7/64 in | 41 | 7.52 | 0.296 | 73.09 | 49 | 2.37 |
| UL 3257 12 AWG — 7/64 in | 65 | 7.98 | 0.314 | 90.40 | 61 | 2.51 |
Auswahl der spezifizierten Ausführung
Use UL 3257 plus AWG and wall option on the order. State 10 kV AC or 25 kV DC duty explicitly and compare the corresponding OD and minimum bend radius before choosing a boot or gland.
Normen
TEBAOFLEX UL 3257 wire is UL-certified appliance wiring material.
| Merkmal | Anforderung oder Referenz |
|---|---|
| Zertifizierung | UL-zertifiziertes AWM |
| Stilbezeichnung | UL 3257 |
| Konstruktionsnorm | UL 758 — Verdrahtungsmaterial für Geräte |
| Flammklassifizierung des Stils | Horizontale Flammprüfung |
Geben Sie in der Einkaufsspezifikation den UL-Stil, die Leitergröße sowie Spannungs- und Temperaturklasse an. Fügen Sie der Anfrage die erforderliche Produktkennzeichnung und Zertifizierungsunterlagen bei.
Kabelempfehlung und Angebot anfordern
Senden Sie die benötigten Funktionen, Kabellänge, mechanische Beanspruchung, Umgebung, Anschlussausführung und Menge. Unser Team prüft die Anwendung vor der Angebotserstellung.
- Geben Sie den Produktnamen oder die SKU sowie die benötigte Kabellänge und Menge an.
- Fügen Sie nach Möglichkeit eine Spezifikation, Zeichnung oder ein Datenblatt bei.