
Type 43 BS 6708 125/72 V Non-Metallic Screened Drill Cable
Type 43 mining cable for hand-held drilling machines in deep mines and on the surface, with the source-defined 125/72 V rating and 1.5 kV test reference.
- Model: Type 43
- Conductor and insulation: flexible tinned copper with the insulation and core construction listed for this model in the supplied PDF
- Screen, pilot, earth and armour arrangement preserved from the source datasheet
- Heavy-duty chloroprene or PCP outer protection as listed for this model
- Original Type datasheet available as the product download
Send the equipment, voltage, conductor area, route, quantity and document requirements for an RFQ.
Type 43 for hand-held drilling machines in deep mines and on the surface
Type 43 mining cable is specified in the supplied BS 6708 datasheet for hand-held drilling machines in deep mines and on the surface. This page keeps the source-listed voltage, test reference, core functions and dimensional tables together so a procurement engineer can compare the requested model against the cable marking and the equipment connection. The editorial focus is the conducting-elastomer screen route for low-voltage drill service, not a generic promise of performance.
The supplied construction uses three phase cores, one pilot and one earth core laid without contact around a semiconducting cradle, with a conducting elastomeric compound and heavy-duty chloroprene sheath. That arrangement matters because Type 43 uses the non-metallic conducting screen construction; Type 44 uses a tinned copper/nylon braided phase screen. The family should therefore be selected by model, core function and installation route as well as by voltage. The gama de cabos para mineração e construção de túneis provides the wider TEBAOFLEX product context.
- Escolha por: confirm the drilling-machine voltage, semiconductive cradle arrangement and non-metallic screen requirement before comparing with Type 44.
- Confirme antes de fazer o pedido: existing sheath marking, conductor area, cable length, route, support or handling system, terminations and the required inspection documents.
- Do not infer: values not listed in the supplied PDF, such as a different current basis, water/oil/UV performance, certification scope or mechanical interchangeability.
When a hand-held drill cable is being replaced, the BS 6708 mining cable replacement guide helps keep the low-voltage drill family and its screen construction distinctions visible.
For a technical quotation, send the equipment nameplate or existing cable marking, voltage and size requirement, installation conditions, quantity, destination and any project-specific test or documentation requirement.
Type 43 construction
The cross-section below is the supplied construction drawing for Type 43. The ordering decision is driven by Type 43 uses the non-metallic conducting screen construction; Type 44 uses a tinned copper/nylon braided phase screen.

Source-listed construction
| Elemento de construção | Valor indicado na fonte |
|---|---|
| Condutor | Electrolytic stranded tinned copper wire, IEC 60228 Class 5 |
| Isolamento | Isolamento EPR |
| Lay-up | All cores laid without contact around a semiconducting cradle |
| Roupa de cama | Conducting elastomeric compound |
| Bainha | Heavy-duty chloroprene outer sheath |
| Arranjo central | Three phase cores, one pilot and one earth core around the semiconducting cradle |
Do not use the drawing as a substitute for the dimensional tables. Confirm the cable end preparation, screen and earth termination, armour bonding and machine interface with the equipment documentation before installation.
Type 43 applications

The supplied datasheet identifies this cable for hand-held drilling machines in deep mines and on the surface. Google result patterns for the BS 6708 family also separate cables by equipment duty, voltage class, core function and whether the route is armoured, screened, flat or auxiliary. That is why this page keeps the Type 43 construction separate from nearby Type numbers.
- Primary duty: hand-held drilling machines in deep mines and on the surface.
- Model boundary: Type 43 uses the non-metallic conducting screen construction; Type 44 uses a tinned copper/nylon braided phase screen.
- Project check: match the cable marking, core map, voltage, termination, route geometry and handling method to the machine drawing.
- Environmental review: confirm the actual mine/quarry conditions and any authority, inspection or documentation requirements; do not infer a certification or material-resistance claim from the model number.
The metallic-screened Type 44 drill cable is the closest model comparison when the project requires a different screen construction; verify the drill maker's cable interface before ordering.
The cable should be released only after the equipment route, required length, conductor area, core functions and connection details are agreed. If the intended duty is different from the source-listed application, request an engineering review through the quotation process.
Type 43 specifications
The summary below identifies the supplied model family. The source-transcribed tables that follow retain the PDF's dimensional, electrical and construction values, including available sizes, resistance, current, diameter, mass, bending or pulling data when the PDF provides them.
| Selection item | Source-linked value |
|---|---|
| Modelo | Type 43 |
| Tensão nominal | 125/72 V |
| Tensão de teste | 1.5 kV |
| Aplicativo | hand-held drilling machines in deep mines and on the surface |
| Norma do produto | BS 6708 |
Complete source-transcribed technical tables
Source PDF: BS6708_TYPE_43_125_72V_HANDHELD_DRILLING_MACHINE_CABLE_datasheet.pdf; 3 pages; 6 extracted tables. Values are not recalculated or replaced by third-party values.
| Parâmetro | Valor |
|---|---|
| Condutor | Electrolytic, stranded, tinned copper wire, IEC 60228 Class 5 |
| Isolamento | EPR |
| Lay-up | All cores are laid up without contacting each other around a semiconducting cradle |
| Roupa de cama | Conducting elastomeric compound |
| Bainha externa | Heavy duty chloroprene outer sheath |
| Parâmetro | Valor |
|---|---|
| Padrão | BS 6708 |
| Tensão nominal | 125/72 V |
| Tensão de teste | 1.5 kV |
| Tipo de cabo | Three phase cores, one pilot core and one earth core laid up around a semiconducting cradle and screened by semiconducting filler |
| CORE DIMENSIONS | ||||
|---|---|---|---|---|
| Nominal cross section | Condutores | Stranding mm | Conductor diameter mm | Insulation thickness mm |
| 5x6 | 5x6 | 84/0.30 | 3.30 | 1.00 |
| CABLE DETAILS | |||||||
|---|---|---|---|---|---|---|---|
| Nominal cross section | Conducting inner sheath thickness mm | Outer sheath thickness mm | Min. OD mm | Max. OD mm | Min. bend radius mm | Approx. weight kg/km | Copper weight kg/km |
| 5x6 | 1.5 | 2.5 | 24.8 | 26.8 | 268 | 1020 | 150 |
| CURRENT RATINGS | |
|---|---|
| Nominal cross section | Continuous current rating at 25 deg C |
| 5x6 | 46 |
| ELECTRICAL DETAILS | |
|---|---|
| Nominal F cross section | Conductors E Max. DC res. at 20 deg C ohm/km |
| 5x6 | 3.48 |
Use the table values with the equipment drawing and approved termination plan. If the requested conductor area, current basis, mechanical limit or environmental condition is not listed in the supplied PDF, treat it as a quotation-stage confirmation item.
Type 43 standards and references
| Assunto | Source-linked reference |
|---|---|
| Norma do produto | BS 6708 |
| Tensão nominal | 125/72 V |
| Tensão de teste | 1.5 kV |
| Source application | hand-held drilling machines in deep mines and on the surface |
The product page preserves the BS 6708 reference appearing in the supplied PDF. The BSI record currently identifies BS 6708:1998 as withdrawn on 22 May 2026; this status note is a standards-reference update, not a claim that the product is currently certified or approved. See the official BSI BS 6708 scope record for the published status.
For an RFQ, state the required standard documents, inspection scope, test report, cable marking, destination rules and any replacement-equivalence requirement. The model number alone does not establish legal installation compliance.
Opções de cabos relacionadas
Compare estas opções de cabos por combinação de serviços, movimentação, carga, tensão e requisito de transmissão.
Cabo de borracha flexível tipo 210 para mineração, 1,1 kV
Uma opção de cabo relacionada para uma aplicação ou perfil de serviço diferente.
Ver produtoCabo flexível para mineração TYPE275 1,1 kV para transporte de cargas
Uma opção de cabo relacionada para uma aplicação ou perfil de serviço diferente.
Ver produtoCabo para mina de carvão subterrânea tipo 240, 1,1 kV a 11 kV
Uma opção de cabo relacionada para uma aplicação ou perfil de serviço diferente.
Ver produtoSolicite uma recomendação e orçamento de cabos.
Envie-nos as especificações dos serviços necessários, comprimento do cabo, capacidade mecânica, ambiente, tipo de terminação e quantidade. Nossa equipe analisará a solicitação antes de enviar um orçamento.
- Inclua o nome do produto ou o código SKU, além do comprimento e da quantidade de cabos necessários.
- Anexe uma especificação, desenho ou ficha técnica, quando disponíveis.

