Solicite um orçamento
CABOS PARA MINERAÇÃO E ESCAVAÇÃO DE TÚNEIS TEBAOFLEX

Type 44 BS 6708 125/72 V Metallic Screened Drill Cable

Type 44 mining cable for hand-held drilling machines in deep mines and on the surface, with the source-defined 125/72 V rating and 1.5 kV test reference.

  • Model: Type 44
  • Conductor and insulation: flexible tinned copper with the insulation and core construction listed for this model in the supplied PDF
  • Screen, pilot, earth and armour arrangement preserved from the source datasheet
  • Heavy-duty chloroprene or PCP outer protection as listed for this model
  • Original Type datasheet available as the product download

Send the equipment, voltage, conductor area, route, quantity and document requirements for an RFQ.

Informações sobre o produto
Marca
TEBAOFLEX
Visão geral do produto

Type 44 for hand-held drilling machines in deep mines and on the surface

Type 44 mining cable is specified in the supplied BS 6708 datasheet for hand-held drilling machines in deep mines and on the surface. This page keeps the source-listed voltage, test reference, core functions and dimensional tables together so a procurement engineer can compare the requested model against the cable marking and the equipment connection. The editorial focus is the individually metallic-screened drill-cable route, not a generic promise of performance.

The supplied construction uses three individually screened phase cores with one unscreened pilot and one unscreened earth core laid around an elastomeric cradle, using EPR insulation and a heavy-duty chloroprene sheath. That arrangement matters because Type 44 is the metallic-screened drill cable; its construction must not be merged with the non-metallic-screened Type 43 page. The family should therefore be selected by model, core function and installation route as well as by voltage. The gama de cabos para mineração e construção de túneis provides the wider TEBAOFLEX product context.

  • Escolha por: confirm whether the drill equipment and termination design require metallic phase screens and separate pilot/earth cores.
  • Confirme antes de fazer o pedido: existing sheath marking, conductor area, cable length, route, support or handling system, terminations and the required inspection documents.
  • Do not infer: values not listed in the supplied PDF, such as a different current basis, water/oil/UV performance, certification scope or mechanical interchangeability.

For a drill-cable project that needs equipment and route context beyond the model label, review the Mining & Tunnelling solutions page with the supplied Type 44 data.

For a technical quotation, send the equipment nameplate or existing cable marking, voltage and size requirement, installation conditions, quantity, destination and any project-specific test or documentation requirement.

Construção

Type 44 construction

The cross-section below is the supplied construction drawing for Type 44. The ordering decision is driven by Type 44 is the metallic-screened drill cable; its construction must not be merged with the non-metallic-screened Type 43 page.

Type 44 cable cross-section showing the supplied power, pilot, earth, screen and protection arrangement
Supplied Type 44 cross-section; the exact core and armour arrangement must be checked against the product datasheet.

Source-listed construction

Elemento de construçãoValor indicado na fonte
CondutorElectrolytic stranded tinned copper wire, IEC 60228 Class 5
IsolamentoIsolamento EPR
TelaTinned copper and nylon braided screen over phase cores; pilot and earth cores are not screened
Lay-upAll cores laid up in contact with each other around an elastomeric cradle
Roupa de camaRubber based bedding compound
BainhaHeavy-duty chloroprene outer sheath
Arranjo centralThree screened phase cores, one unscreened pilot and one unscreened earth core

Do not use the drawing as a substitute for the dimensional tables. Confirm the cable end preparation, screen and earth termination, armour bonding and machine interface with the equipment documentation before installation.

Aplicações

Type 44 applications

Type 44 mining cable application with hand-held drilling equipment underground
Media-library application scene showing hand-held drilling equipment underground; used for application context, not as a model-specific construction proof.

The supplied datasheet identifies this cable for hand-held drilling machines in deep mines and on the surface. Google result patterns for the BS 6708 family also separate cables by equipment duty, voltage class, core function and whether the route is armoured, screened, flat or auxiliary. That is why this page keeps the Type 44 construction separate from nearby Type numbers.

  • Primary duty: hand-held drilling machines in deep mines and on the surface.
  • Model boundary: Type 44 is the metallic-screened drill cable; its construction must not be merged with the non-metallic-screened Type 43 page.
  • Project check: match the cable marking, core map, voltage, termination, route geometry and handling method to the machine drawing.
  • Environmental review: confirm the actual mine/quarry conditions and any authority, inspection or documentation requirements; do not infer a certification or material-resistance claim from the model number.

Where a non-metallic conducting screen is specified, compare the Type 43 drill cable and keep the screen construction aligned with the approved drilling-machine documentation.

The cable should be released only after the equipment route, required length, conductor area, core functions and connection details are agreed. If the intended duty is different from the source-listed application, request an engineering review through the quotation process.

Especificações

Type 44 specifications

The summary below identifies the supplied model family. The source-transcribed tables that follow retain the PDF's dimensional, electrical and construction values, including available sizes, resistance, current, diameter, mass, bending or pulling data when the PDF provides them.

Selection itemSource-linked value
ModeloType 44
Tensão nominal125/72 V
Tensão de teste1.5 kV
Aplicativohand-held drilling machines in deep mines and on the surface
Norma do produtoBS 6708

Complete source-transcribed technical tables

Source PDF: BS6708_TYPE_44_125_72V_HANDHELD_DRILLING_MACHINE_CABLE_datasheet.pdf; 3 pages; 6 extracted tables. Values are not recalculated or replaced by third-party values.

Source table 1, PDF page 1
ParâmetroValor
CondutorElectrolytic, stranded, tinned copper wire, IEC 60228 Class 5
IsolamentoEPR
SeparadorColored textile tape for core identification
TelaTinned copper and nylon braided screen over phase cores; pilot and earth cores are not screened
Lay-upAll cores are laid up in contact with each other
Roupa de camaRubber based bedding compound
Bainha externaHeavy duty chloroprene outer sheath
Source table 2, PDF page 1
ParâmetroValor
PadrãoBS 6708
Tensão nominal125/72 V
Tensão de teste1.5 kV
Tipo de caboThree phase cores with composite individual screens, one unscreened pilot core and one unscreened earth core laid up around an elastomeric cradle
Source table 1, PDF page 2
CORE DIMENSIONS
Nominal cross sectionPhase / earth / pilot conductorsStranding mmConductor diameter mmInsulation thickness mmTotal screen cross section mm2
5x63x6 / 1x6 / 1x684/0.303.301.0011
Source table 2, PDF page 2
CABLE DETAILS
Nominal cross sectionMin. OD mmMax. OD mmMin. bend radius mmOuter sheath thickness mmMax pulling tension kgfApprox. weight kg/kmCopper weight kg/km
5x624.726.72413.02181150400
Source table 1, PDF page 3
CURRENT RATINGS
Nominal cross sectionContinuous current rating at 25 deg CShort circuit current for 1 s A
5x646908
Source table 2, PDF page 3
ELECTRICAL DETAILS
Nominal cross sectionFPhase and earth conductors Max. DC res. at 20 deg C ohm/kmPilot conductor Max. DC res. at 20 deg C ohm/kmE3 screens in parallel Max. DC res. at 20 deg C ohm/km
5x63.483.4811

Use the table values with the equipment drawing and approved termination plan. If the requested conductor area, current basis, mechanical limit or environmental condition is not listed in the supplied PDF, treat it as a quotation-stage confirmation item.

Padrões

Type 44 standards and references

AssuntoSource-linked reference
Norma do produtoBS 6708
Tensão nominal125/72 V
Tensão de teste1.5 kV
Source applicationhand-held drilling machines in deep mines and on the surface

The product page preserves the BS 6708 reference appearing in the supplied PDF. The BSI record currently identifies BS 6708:1998 as withdrawn on 22 May 2026; this status note is a standards-reference update, not a claim that the product is currently certified or approved. See the official BSI BS 6708 scope record for the published status.

For an RFQ, state the required standard documents, inspection scope, test report, cable marking, destination rules and any replacement-equivalence requirement. The model number alone does not establish legal installation compliance.

Comparar por dever

Opções de cabos relacionadas

Compare estas opções de cabos por combinação de serviços, movimentação, carga, tensão e requisito de transmissão.

Cotação elaborada por engenheiros

Solicite uma recomendação e orçamento de cabos.

Envie-nos as especificações dos serviços necessários, comprimento do cabo, capacidade mecânica, ambiente, tipo de terminação e quantidade. Nossa equipe analisará a solicitação antes de enviar um orçamento.

  • Inclua o nome do produto ou o código SKU, além do comprimento e da quantidade de cabos necessários.
  • Anexe uma especificação, desenho ou ficha técnica, quando disponíveis.

    Opcional: anexe uma especificação do cabo, desenho, ficha técnica ou imagem do produto (PDF, DOC, DOCX, XLS, XLSX, CSV, JPG ou PNG; máximo de 10 MB).

    Ao enviar este formulário, você concorda que a TEBAOFLEX pode usar as informações de contato e os arquivos fornecidos para analisar e responder à sua solicitação. Os arquivos são usados para orçamentos e comunicação técnica relacionados à sua solicitação. Consulte nossa política de privacidade. política de Privacidade Para obter informações atuais sobre o tratamento e a retenção de dados.

    * Campos obrigatórios. Inclua os detalhes principais do cabo ou da aplicação para análise.