3GSEYQY 18/30 kV Screened Tunnel Cable

18/30 kV screened tunnel cable with EPR insulation, copper tape screens and minimum 90% galvanized steel wire braid.

Informações sobre o produto
Marca
TEBAOFLEX
Visão geral do produto

3GSEYQY is an 18/30 kV screened tunnel cable for mobile mine and tunnelling equipment and for stationary connections at high-voltage transformers, main panels and switchboards. The supplied VDE datasheet specifies three concentrically laid screened cores, circular stranded plain annealed copper Class 2 conductors, 3GI3 EPR insulation with inner and outer semiconductive layers, copper tape over each main core, PVC filler, galvanized steel wire braid with minimum 90% coverage and a red 5GM5 elastomer sheath. The source lists 48 kV AC testing, 90 °C maximum conductor temperature and 250 °C short-circuit temperature. Fixed service is −25 °C to +90 °C and mobile service is +5 °C to +90 °C. Conductor sizes in the supplied table range from 3 × 25/16 to 3 × 120/16. The braid and screening arrangement should be checked against the specified mechanical protection and installation environment before quotation. For mobile service, coordinate the requested bending and torsional duty with the support system, protective routing and termination space; verify the applicable current-carrying table for the actual ambient condition. Confirm the final conductor size, route, current calculation, termination, earthing arrangement, test documentation and delivery schedule with TEBAOFLEX.

Construção

3GSEYQY screened tunnel-cable construction

3GSEYQY uses three screened medium-voltage cores laid concentrically. Each main core has EPR insulation with inner and outer semiconductive layers, followed by a copper tape screen; PVC filler, galvanized steel wire braid and a red elastomer sheath complete the supplied arrangement.

3GSEYQY cable cross-section showing three screened power cores, copper tape screens, steel wire braid and red outer sheath
Supplied 3GSEYQY cross-section showing the screened three-core and galvanized steel wire braid arrangement.
Construction identified in the supplied VDE datasheet
ParâmetroValor indicado na fonte
CondutorCabo circular trançado de cobre recozido, Classe 2 de acordo com a norma IEC 60228.
Insulation / field control3GI3 quality EPR rubber compound with extruded inner and outer semi-conductive layers
Identificação centralNatural colouring with black semi-conductive layer
TelaCopper tapes applied over each main core
Lay-upThree screened cores laid up concentrically
Roupa de camaEnchimento de PVC
ArmaduraMalha de arame de aço galvanizado com cobertura mínima de 90%
Bainha exterior5GM5 type elastomer compound, red

The copper tape screens provide the documented electrical-screening layer while the ≥90% braid supplies mechanical protection. Confirm the termination and earthing arrangement against the project drawing.

Aplicações

Applications for 3GSEYQY

The supplied application positions this 18/30 kV screened tunnel cable for mobile operating equipment in mines, underground excavations and tunnelling environments. It is also listed for stationary connections to high-voltage transformers, main panels and switchboards.

3GSEYQY tunnel cable application with medium-voltage transformer and switchgear in an open-cast mining environment
Existing Media Library application image illustrating the medium-voltage transformer and switchgear context; confirm the actual route and equipment interface for 3GSEYQY.
  • Mobile mining and tunnelling equipment using the stated 18/30 kV system
  • Stationary high-voltage transformer, main-panel and switchboard connections listed in the source
  • Underground excavation and tunnel routes where screening and mechanical braid protection are required
  • Confirm route movement, cable support, terminations, earthing, current calculation and final bending arrangement before quotation

The cable is not selected by voltage alone. Provide the equipment, route, installation mode and protection requirements so the supplied construction can be checked against the actual duty.

Especificações

3GSEYQY specifications

Nominal electrical and dimensional values are transcribed from the supplied 3GSEYQY datasheet. Confirm the final size, route and termination drawing before order release.

3GSEYQY electrical and mechanical characteristics
ParâmetroValor indicado na fonte
Rated voltage U₀/U18/30 kV
tensão de teste CA48 kV
Maximum permissible AC operating voltage20,8/36 kV
Maximum permissible DC operating voltage27/54 kV
temperatura máxima do condutor90 °C
temperatura máxima de curto-circuito250 °C
Fixed working temperature−25 °C to +90 °C
Mobile working temperature+5 °C to +90 °C
carga máxima de tração15 N/mm²
Torção máxima25°/m
Raio de curvatura mínimoDe acordo com a norma DIN VDE 0298-3
Current carrying capacityDe acordo com a norma DIN VDE 0298-4
3GSEYQY size and weight data
Secção transversal (mm²)Overall diameter min–max (mm)Max. DC resistance at 20 °C (Ω/km)Approx. weight (kg/km)
3 × 25/1665.1–72.00.7276860
3 × 35/1668.0–75.10.5247640
3 × 50/1670.8–78.30.3878520
3 × 70/1674.5–82.40.2689760
3 × 95/1679.0–87.20.19311280
3 × 120/1682.2–90.90.15312600

The datasheet notes that dimensions may vary with manufacturing tolerances. Other conductor sizes, packing forms and delivery lengths are available on request.

Padrões

3GSEYQY standards and test references

The following references are recorded as they appear in the supplied datasheet. They are presented as standards and test references, not as a broader approval claim.

Standards, tests and approvals referenced for this product
ParâmetroValor indicado na fonte
ConstruçãoDIN VDE 0250-605 e IEC 60502-2
General requirementsDIN VDE 0250-1
Guide useDIN VDE 0298-3
Electrical testsDIN VDE 0472-501, 503, 508
Non-electrical testsDIN VDE 0472-401, 402, 602, 303, 615
Under-fire-condition testsDIN VDE 0472-803, 804
retardante de chamasVDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1

State the required standard edition, inspection scope and test documentation with the RFQ. Current carrying capacity and minimum bending radius follow the supplied DIN VDE references.

Comparar por dever

Opções de cabos relacionadas

Compare estas opções de cabos por combinação de serviços, movimentação, carga, tensão e requisito de transmissão.

Cotação elaborada por engenheiros

Solicite uma recomendação e orçamento de cabos.

Envie-nos as especificações dos serviços necessários, comprimento do cabo, capacidade mecânica, ambiente, tipo de terminação e quantidade. Nossa equipe analisará a solicitação antes de enviar um orçamento.

  • Inclua o nome do produto ou o código SKU, além do comprimento e da quantidade de cabos necessários.
  • Anexe uma especificação, desenho ou ficha técnica, quando disponíveis.

    Opcional: anexe uma especificação do cabo, desenho, ficha técnica ou imagem do produto (PDF, DOC, DOCX, XLS, XLSX, CSV, JPG ou PNG; máximo de 10 MB).

    Ao enviar este formulário, você concorda que a TEBAOFLEX pode usar as informações de contato e os arquivos fornecidos para analisar e responder à sua solicitação. Os arquivos são usados para orçamentos e comunicação técnica relacionados à sua solicitação. Consulte nossa política de privacidade. política de Privacidade Para obter informações atuais sobre o tratamento e a retenção de dados.

    * Campos obrigatórios. Inclua os detalhes principais do cabo ou da aplicação para análise.