Type 307M BS 6708 1900/3300 V Screened Pilot Coal Cutter Cable

Type 307M mining cable for excavating, crushing and coal-cutting equipment, with the source-defined 1900/3300 V rating and 7.5 kV test reference.

  • Model: Type 307M
  • Conductor and insulation: flexible tinned copper with the insulation and core construction listed for this model in the supplied PDF
  • Screen, pilot, earth and armour arrangement preserved from the source datasheet
  • Heavy-duty chloroprene or PCP outer protection as listed for this model
  • Original Type datasheet available as the product download

Send the equipment, voltage, conductor area, route, quantity and document requirements for an RFQ.

Informações sobre o produto
Marca
TEBAOFLEX
Visão geral do produto

Type 307M for excavating, crushing and coal-cutting equipment

Type 307M mining cable is specified in the supplied BS 6708 datasheet for excavating, crushing and coal-cutting equipment. This page keeps the source-listed voltage, test reference, core functions and dimensional tables together so a procurement engineer can compare the requested model against the cable marking and the equipment connection. The editorial focus is the fully screened pilot option in the 3.3 kV family, not a generic promise of performance.

The supplied construction uses three screened phase cores and one screened pilot core laid up in contact with the bare copper earth conductor, with EPR insulation and a heavy-duty chloroprene sheath. That arrangement matters because The screened pilot is the defining Type 307M feature; it is not interchangeable with Type 307 or Type 307S solely by voltage. The family should therefore be selected by model, core function and installation route as well as by voltage. The gama de cabos para mineração e construção de túneis provides the wider TEBAOFLEX product context.

  • Escolha por: confirm the need for a screened pilot and match pilot continuity, termination and monitoring requirements to the machine system.
  • Confirme antes de fazer o pedido: existing sheath marking, conductor area, cable length, route, support or handling system, terminations and the required inspection documents.
  • Do not infer: values not listed in the supplied PDF, such as a different current basis, water/oil/UV performance, certification scope or mechanical interchangeability.

For equipment-specific routing and handling questions around the 3.3 kV class, review the Mining & Tunnelling solutions page with this Type 307M data.

For a technical quotation, send the equipment nameplate or existing cable marking, voltage and size requirement, installation conditions, quantity, destination and any project-specific test or documentation requirement.

Construção

Type 307M construction

The cross-section below is the supplied construction drawing for Type 307M. The ordering decision is driven by The screened pilot is the defining Type 307M feature; it is not interchangeable with Type 307 or Type 307S solely by voltage.

Type 307M cable cross-section showing the supplied power, pilot, earth, screen and protection arrangement
Supplied Type 307M cross-section; the exact core and armour arrangement must be checked against the product datasheet.

Source-listed construction

Elemento de construçãoValor indicado na fonte
CondutorElectrolytic stranded tinned copper wire, IEC 60228 Class 5
IsolamentoEPR; earth conductor is not insulated
TelaTinned copper and nylon braided screen over phase and pilot cores
Lay-upAll cores laid up in contact with the bare copper earth conductor
BainhaHeavy-duty chloroprene outer sheath
Arranjo centralThree screened phase cores, one screened pilot core and a bare copper earth conductor

Do not use the drawing as a substitute for the dimensional tables. Confirm the cable end preparation, screen and earth termination, armour bonding and machine interface with the equipment documentation before installation.

Aplicações

Type 307M applications

Type 307M mining cable application with underground longwall mining equipment
Media-library application scene showing underground longwall mining equipment; used for application context, not as a model-specific construction proof.

The supplied datasheet identifies this cable for excavating, crushing and coal-cutting equipment. Google result patterns for the BS 6708 family also separate cables by equipment duty, voltage class, core function and whether the route is armoured, screened, flat or auxiliary. That is why this page keeps the Type 307M construction separate from nearby Type numbers.

  • Primary duty: excavating, crushing and coal-cutting equipment.
  • Model boundary: The screened pilot is the defining Type 307M feature; it is not interchangeable with Type 307 or Type 307S solely by voltage.
  • Project check: match the cable marking, core map, voltage, termination, route geometry and handling method to the machine drawing.
  • Environmental review: confirm the actual mine/quarry conditions and any authority, inspection or documentation requirements; do not infer a certification or material-resistance claim from the model number.

When the specification calls for a three-core pilot unit instead of a screened single pilot, compare the Type 307S cable and retain the exact model in the equipment schedule.

The cable should be released only after the equipment route, required length, conductor area, core functions and connection details are agreed. If the intended duty is different from the source-listed application, request an engineering review through the quotation process.

Especificações

Type 307M specifications

The summary below identifies the supplied model family. The source-transcribed tables that follow retain the PDF's dimensional, electrical and construction values, including available sizes, resistance, current, diameter, mass, bending or pulling data when the PDF provides them.

Selection itemSource-linked value
ModeloType 307M
Tensão nominal1900/3300 V
Tensão de teste7.5 kV
Aplicativoexcavating, crushing and coal-cutting equipment
Norma do produtoBS 6708

Complete source-transcribed technical tables

Source PDF: BS6708_TYPE_307M_1900_3300V_POWER_SUPPLY_CABLE_datasheet.pdf; 3 pages; 4 extracted tables. Values are not recalculated or replaced by third-party values.

Source table 1, PDF page 1
ParâmetroValor
CondutorElectrolytic, stranded, tinned copper wire, IEC 60228 Class 5
IsolamentoEPR; the earth conductor is not insulated
SeparadorColored textile tape for core identification
TelaTinned copper and nylon braided screen over phase and pilot cores
Lay-upAll cores laid up in contact with the bare copper earth conductor
Roupa de camaRubber based bedding compound
Bainha exteriorHeavy duty chloroprene outer sheath
Source table 2, PDF page 1
ParâmetroValor
PadrãoBS 6708
Tensão nominal1900/3300 V
Tensão de teste7.5 kV
Arranjo centralThree screened phase cores, one screened pilot core and a bare copper earth conductor
Source table 1, PDF page 2
CABLE DIMENSIONS
Parâmetro3x25 +25+253x35 +25+353x50 +35+503x70 +50+703x95 +50+953x120 +70+120
Phase conductor cross section mm23x253x353x503x703x953x120
Phase conductor stranding196/0.40276/0.40396/0.40360/0.50475/0.50608/0.50
Phase conductor diameter nominal mm6.758.359.4011.3512.7515.10
Phase insulation diameter nominal mm13.1014.7515.8017.8019.2021.60
Phase screen diameter mm15.5017.1018.2020.1521.6023.95
Earth conductor cross section mm21x251x251x351x501x501x70
Earth conductor stranding196/0.40196/0.40276/0.40396/0.40396/0.40360/0.50
Earth conductor diameter nominal mm6.756.758.209.809.8011.70
Pilot conductor cross section mm21x251x351x501x701x951x120
Pilot conductor stranding196/0.40276/0.40396/0.40360/0.50475/0.50608/0.50
Pilot conductor diameter nominal mm6.758.359.4011.3512.7515.10
Pilot insulation diameter nominal mm13.1014.7515.8017.8019.2021.60
Pilot screen diameter mm15.5017.1018.2020.1521.6023.95
Minimum overall diameter mm47.451.656.862.868.973.4
Maximum overall diameter mm49.954.659.865.872.777.4
Minimum bending radius mm399437478526581617
Maximum pulling tension kgf6428341200168020002000
Approximate cable weight kg/km4200500065008100980011600
Copper weight kg/km166420482866368245465650
Source table 1, PDF page 3
ELECTRICAL DETAILS
Parâmetro3x25 +25+253x35 +25+353x50 +35+503x70 +50+703x95 +50+953x120 +70+120
Continuous current rating at 25 deg C ambient A110135170205250295
Intermittent current rating at 25 deg C ambient A130155210255315360
Phase conductor DC resistance at 20 deg C ohm/km0.7950.5650.3930.2770.2100.164
Pilot conductor DC resistance at 20 deg C ohm/km0.7950.5650.3930.2770.2100.164
Four screens and earth in parallel DC resistance ohm/km0.450.450.310.310.250.25
Nominal reactance at 50 Hz ohm/km0.1250.1170.1130.1080.1050.101
Nominal reactance at 60 Hz ohm/km0.1500.1410.1360.1290.1260.121
Minimum insulation resistance at 20 deg C MOhm/km12501100950820720660
3 phase voltage drop at full load mV/A/m1.691.210.850.610.480.39

Use the table values with the equipment drawing and approved termination plan. If the requested conductor area, current basis, mechanical limit or environmental condition is not listed in the supplied PDF, treat it as a quotation-stage confirmation item.

Padrões

Type 307M standards and references

AssuntoSource-linked reference
Norma do produtoBS 6708
Tensão nominal1900/3300 V
Tensão de teste7.5 kV
Source applicationexcavating, crushing and coal-cutting equipment

The product page preserves the BS 6708 reference appearing in the supplied PDF. The BSI record currently identifies BS 6708:1998 as withdrawn on 22 May 2026; this status note is a standards-reference update, not a claim that the product is currently certified or approved. See the official BSI BS 6708 scope record for the published status.

For an RFQ, state the required standard documents, inspection scope, test report, cable marking, destination rules and any replacement-equivalence requirement. The model number alone does not establish legal installation compliance.

Comparar por dever

Opções de cabos relacionadas

Compare estas opções de cabos por combinação de serviços, movimentação, carga, tensão e requisito de transmissão.

Cotação elaborada por engenheiros

Solicite uma recomendação e orçamento de cabos.

Envie-nos as especificações dos serviços necessários, comprimento do cabo, capacidade mecânica, ambiente, tipo de terminação e quantidade. Nossa equipe analisará a solicitação antes de enviar um orçamento.

  • Inclua o nome do produto ou o código SKU, além do comprimento e da quantidade de cabos necessários.
  • Anexe uma especificação, desenho ou ficha técnica, quando disponíveis.

    Opcional: anexe uma especificação do cabo, desenho, ficha técnica ou imagem do produto (PDF, DOC, DOCX, XLS, XLSX, CSV, JPG ou PNG; máximo de 10 MB).

    Ao enviar este formulário, você concorda que a TEBAOFLEX pode usar as informações de contato e os arquivos fornecidos para analisar e responder à sua solicitação. Os arquivos são usados para orçamentos e comunicação técnica relacionados à sua solicitação. Consulte nossa política de privacidade. política de Privacidade Para obter informações atuais sobre o tratamento e a retenção de dados.

    * Campos obrigatórios. Inclua os detalhes principais do cabo ou da aplicação para análise.