Type 307M BS 6708 1900/3300 V Screened Pilot Coal Cutter Cable
Type 307M mining cable for excavating, crushing and coal-cutting equipment, with the source-defined 1900/3300 V rating and 7.5 kV test reference.
- Model: Type 307M
- Conductor and insulation: flexible tinned copper with the insulation and core construction listed for this model in the supplied PDF
- Screen, pilot, earth and armour arrangement preserved from the source datasheet
- Heavy-duty chloroprene or PCP outer protection as listed for this model
- Original Type datasheet available as the product download
Send the equipment, voltage, conductor area, route, quantity and document requirements for an RFQ.
Type 307M for excavating, crushing and coal-cutting equipment
Type 307M mining cable is specified in the supplied BS 6708 datasheet for excavating, crushing and coal-cutting equipment. This page keeps the source-listed voltage, test reference, core functions and dimensional tables together so a procurement engineer can compare the requested model against the cable marking and the equipment connection. The editorial focus is the fully screened pilot option in the 3.3 kV family, not a generic promise of performance.
The supplied construction uses three screened phase cores and one screened pilot core laid up in contact with the bare copper earth conductor, with EPR insulation and a heavy-duty chloroprene sheath. That arrangement matters because The screened pilot is the defining Type 307M feature; it is not interchangeable with Type 307 or Type 307S solely by voltage. The family should therefore be selected by model, core function and installation route as well as by voltage. The gamme de câbles pour l'exploitation minière et le creusement de tunnels provides the wider TEBAOFLEX product context.
- Choisir par : confirm the need for a screened pilot and match pilot continuity, termination and monitoring requirements to the machine system.
- Confirmez avant de commander : existing sheath marking, conductor area, cable length, route, support or handling system, terminations and the required inspection documents.
- Do not infer: values not listed in the supplied PDF, such as a different current basis, water/oil/UV performance, certification scope or mechanical interchangeability.
For equipment-specific routing and handling questions around the 3.3 kV class, review the Mining & Tunnelling solutions page with this Type 307M data.
For a technical quotation, send the equipment nameplate or existing cable marking, voltage and size requirement, installation conditions, quantity, destination and any project-specific test or documentation requirement.
Type 307M construction
The cross-section below is the supplied construction drawing for Type 307M. The ordering decision is driven by The screened pilot is the defining Type 307M feature; it is not interchangeable with Type 307 or Type 307S solely by voltage.

Source-listed construction
| Élément de construction | Valeur indiquée dans la source |
|---|---|
| Conducteur | Electrolytic stranded tinned copper wire, IEC 60228 Class 5 |
| Isolation | EPR; earth conductor is not insulated |
| Écran | Tinned copper and nylon braided screen over phase and pilot cores |
| Lay-up | All cores laid up in contact with the bare copper earth conductor |
| Gaine | Heavy-duty chloroprene outer sheath |
| Agencement de base | Three screened phase cores, one screened pilot core and a bare copper earth conductor |
Do not use the drawing as a substitute for the dimensional tables. Confirm the cable end preparation, screen and earth termination, armour bonding and machine interface with the equipment documentation before installation.
Type 307M applications

The supplied datasheet identifies this cable for excavating, crushing and coal-cutting equipment. Google result patterns for the BS 6708 family also separate cables by equipment duty, voltage class, core function and whether the route is armoured, screened, flat or auxiliary. That is why this page keeps the Type 307M construction separate from nearby Type numbers.
- Primary duty: excavating, crushing and coal-cutting equipment.
- Model boundary: The screened pilot is the defining Type 307M feature; it is not interchangeable with Type 307 or Type 307S solely by voltage.
- Project check: match the cable marking, core map, voltage, termination, route geometry and handling method to the machine drawing.
- Environmental review: confirm the actual mine/quarry conditions and any authority, inspection or documentation requirements; do not infer a certification or material-resistance claim from the model number.
When the specification calls for a three-core pilot unit instead of a screened single pilot, compare the Type 307S cable and retain the exact model in the equipment schedule.
The cable should be released only after the equipment route, required length, conductor area, core functions and connection details are agreed. If the intended duty is different from the source-listed application, request an engineering review through the quotation process.
Type 307M specifications
The summary below identifies the supplied model family. The source-transcribed tables that follow retain the PDF's dimensional, electrical and construction values, including available sizes, resistance, current, diameter, mass, bending or pulling data when the PDF provides them.
| Selection item | Source-linked value |
|---|---|
| Modèle | Type 307M |
| Tension nominale | 1900/3300 V |
| Tension d'essai | 7.5 kV |
| Application | excavating, crushing and coal-cutting equipment |
| Norme du produit | BS 6708 |
Complete source-transcribed technical tables
Source PDF: BS6708_TYPE_307M_1900_3300V_POWER_SUPPLY_CABLE_datasheet.pdf; 3 pages; 4 extracted tables. Values are not recalculated or replaced by third-party values.
| Paramètre | Valeur |
|---|---|
| Conducteur | Electrolytic, stranded, tinned copper wire, IEC 60228 Class 5 |
| Isolation | EPR; the earth conductor is not insulated |
| Séparateur | Colored textile tape for core identification |
| Écran | Tinned copper and nylon braided screen over phase and pilot cores |
| Lay-up | All cores laid up in contact with the bare copper earth conductor |
| Literie | Rubber based bedding compound |
| gaine extérieure | Heavy duty chloroprene outer sheath |
| Paramètre | Valeur |
|---|---|
| Standard | BS 6708 |
| Tension nominale | 1900/3300 V |
| Tension d'essai | 7.5 kV |
| Agencement de base | Three screened phase cores, one screened pilot core and a bare copper earth conductor |
| CABLE DIMENSIONS | ||||||
|---|---|---|---|---|---|---|
| Paramètre | 3x25 +25+25 | 3x35 +25+35 | 3x50 +35+50 | 3x70 +50+70 | 3x95 +50+95 | 3x120 +70+120 |
| Phase conductor cross section mm2 | 3x25 | 3x35 | 3x50 | 3x70 | 3x95 | 3x120 |
| Phase conductor stranding | 196/0.40 | 276/0.40 | 396/0.40 | 360/0.50 | 475/0.50 | 608/0.50 |
| Phase conductor diameter nominal mm | 6.75 | 8.35 | 9.40 | 11.35 | 12.75 | 15.10 |
| Phase insulation diameter nominal mm | 13.10 | 14.75 | 15.80 | 17.80 | 19.20 | 21.60 |
| Phase screen diameter mm | 15.50 | 17.10 | 18.20 | 20.15 | 21.60 | 23.95 |
| Earth conductor cross section mm2 | 1x25 | 1x25 | 1x35 | 1x50 | 1x50 | 1x70 |
| Earth conductor stranding | 196/0.40 | 196/0.40 | 276/0.40 | 396/0.40 | 396/0.40 | 360/0.50 |
| Earth conductor diameter nominal mm | 6.75 | 6.75 | 8.20 | 9.80 | 9.80 | 11.70 |
| Pilot conductor cross section mm2 | 1x25 | 1x35 | 1x50 | 1x70 | 1x95 | 1x120 |
| Pilot conductor stranding | 196/0.40 | 276/0.40 | 396/0.40 | 360/0.50 | 475/0.50 | 608/0.50 |
| Pilot conductor diameter nominal mm | 6.75 | 8.35 | 9.40 | 11.35 | 12.75 | 15.10 |
| Pilot insulation diameter nominal mm | 13.10 | 14.75 | 15.80 | 17.80 | 19.20 | 21.60 |
| Pilot screen diameter mm | 15.50 | 17.10 | 18.20 | 20.15 | 21.60 | 23.95 |
| Minimum overall diameter mm | 47.4 | 51.6 | 56.8 | 62.8 | 68.9 | 73.4 |
| Maximum overall diameter mm | 49.9 | 54.6 | 59.8 | 65.8 | 72.7 | 77.4 |
| Minimum bending radius mm | 399 | 437 | 478 | 526 | 581 | 617 |
| Maximum pulling tension kgf | 642 | 834 | 1200 | 1680 | 2000 | 2000 |
| Approximate cable weight kg/km | 4200 | 5000 | 6500 | 8100 | 9800 | 11600 |
| Copper weight kg/km | 1664 | 2048 | 2866 | 3682 | 4546 | 5650 |
| ELECTRICAL DETAILS | ||||||
|---|---|---|---|---|---|---|
| Paramètre | 3x25 +25+25 | 3x35 +25+35 | 3x50 +35+50 | 3x70 +50+70 | 3x95 +50+95 | 3x120 +70+120 |
| Continuous current rating at 25 deg C ambient A | 110 | 135 | 170 | 205 | 250 | 295 |
| Intermittent current rating at 25 deg C ambient A | 130 | 155 | 210 | 255 | 315 | 360 |
| Phase conductor DC resistance at 20 deg C ohm/km | 0.795 | 0.565 | 0.393 | 0.277 | 0.210 | 0.164 |
| Pilot conductor DC resistance at 20 deg C ohm/km | 0.795 | 0.565 | 0.393 | 0.277 | 0.210 | 0.164 |
| Four screens and earth in parallel DC resistance ohm/km | 0.45 | 0.45 | 0.31 | 0.31 | 0.25 | 0.25 |
| Nominal reactance at 50 Hz ohm/km | 0.125 | 0.117 | 0.113 | 0.108 | 0.105 | 0.101 |
| Nominal reactance at 60 Hz ohm/km | 0.150 | 0.141 | 0.136 | 0.129 | 0.126 | 0.121 |
| Minimum insulation resistance at 20 deg C MOhm/km | 1250 | 1100 | 950 | 820 | 720 | 660 |
| 3 phase voltage drop at full load mV/A/m | 1.69 | 1.21 | 0.85 | 0.61 | 0.48 | 0.39 |
Use the table values with the equipment drawing and approved termination plan. If the requested conductor area, current basis, mechanical limit or environmental condition is not listed in the supplied PDF, treat it as a quotation-stage confirmation item.
Type 307M standards and references
| Objet | Source-linked reference |
|---|---|
| Norme du produit | BS 6708 |
| Tension nominale | 1900/3300 V |
| Tension d'essai | 7.5 kV |
| Source application | excavating, crushing and coal-cutting equipment |
The product page preserves the BS 6708 reference appearing in the supplied PDF. The BSI record currently identifies BS 6708:1998 as withdrawn on 22 May 2026; this status note is a standards-reference update, not a claim that the product is currently certified or approved. See the official BSI BS 6708 scope record for the published status.
For an RFQ, state the required standard documents, inspection scope, test report, cable marking, destination rules and any replacement-equivalence requirement. The model number alone does not establish legal installation compliance.
Options de câbles associées
Comparez ces options de câbles en fonction de la combinaison de services, du mouvement, de la charge, de la tension et des exigences de transmission.
Type 245 Flexible Rubber Mining Cable 1.1–6.6 kV
Une option de câble similaire pour une application ou un profil de service différent.
Voir le produitCâble d'alimentation blindé pour l'industrie minière TYPE260
Une option de câble similaire pour une application ou un profil de service différent.
Voir le produitCâble souterrain pour mine de charbon de type 240, 1,1 kV à 11 kV
Une option de câble similaire pour une application ou un profil de service différent.
Voir le produitDemandez une recommandation et un devis pour un câble.
Veuillez nous indiquer les services requis, la longueur du câble, les contraintes mécaniques, l'environnement, le type de terminaison et la quantité. Notre équipe examinera votre demande avant de vous établir un devis.
- Veuillez inclure le nom du produit ou son SKU, ainsi que la longueur et la quantité de câble requises.
- Joignez une fiche technique, un dessin ou une fiche de spécifications si disponible.