Obtenir un devis
CÂBLES MINIERS ET DE TUNNELAGE Modèle / construction

Type 44 BS 6708 125/72 V Metallic Screened Drill Cable

Type 44 mining cable for hand-held drilling machines in deep mines and on the surface, with the source-defined 125/72 V rating and 1.5 kV test reference.

  • Model: Type 44
  • Conductor and insulation: flexible tinned copper with the insulation and core construction listed for this model in the supplied PDF
  • Screen, pilot, earth and armour arrangement preserved from the source datasheet
  • Heavy-duty chloroprene or PCP outer protection as listed for this model
  • Original Type datasheet available as the product download

Send the equipment, voltage, conductor area, route, quantity and document requirements for an RFQ.

Informations sur le produit
Marque
Modèle / construction
Présentation du produit

Type 44 for hand-held drilling machines in deep mines and on the surface

Type 44 mining cable is specified in the supplied BS 6708 datasheet for hand-held drilling machines in deep mines and on the surface. This page keeps the source-listed voltage, test reference, core functions and dimensional tables together so a procurement engineer can compare the requested model against the cable marking and the equipment connection. The editorial focus is the individually metallic-screened drill-cable route, not a generic promise of performance.

The supplied construction uses three individually screened phase cores with one unscreened pilot and one unscreened earth core laid around an elastomeric cradle, using EPR insulation and a heavy-duty chloroprene sheath. That arrangement matters because Type 44 is the metallic-screened drill cable; its construction must not be merged with the non-metallic-screened Type 43 page. The family should therefore be selected by model, core function and installation route as well as by voltage. The gamme de câbles pour l'exploitation minière et le creusement de tunnels provides the wider TEBAOFLEX product context.

  • Choisir par : confirm whether the drill equipment and termination design require metallic phase screens and separate pilot/earth cores.
  • Confirmez avant de commander : existing sheath marking, conductor area, cable length, route, support or handling system, terminations and the required inspection documents.
  • Do not infer: values not listed in the supplied PDF, such as a different current basis, water/oil/UV performance, certification scope or mechanical interchangeability.

For a drill-cable project that needs equipment and route context beyond the model label, review the Mining & Tunnelling solutions page with the supplied Type 44 data.

For a technical quotation, send the equipment nameplate or existing cable marking, voltage and size requirement, installation conditions, quantity, destination and any project-specific test or documentation requirement.

Construction

Type 44 construction

The cross-section below is the supplied construction drawing for Type 44. The ordering decision is driven by Type 44 is the metallic-screened drill cable; its construction must not be merged with the non-metallic-screened Type 43 page.

Type 44 cable cross-section showing the supplied power, pilot, earth, screen and protection arrangement
Supplied Type 44 cross-section; the exact core and armour arrangement must be checked against the product datasheet.

Source-listed construction

Élément de constructionValeur indiquée dans la source
ConducteurElectrolytic stranded tinned copper wire, IEC 60228 Class 5
IsolationIsolation EPR
ÉcranTinned copper and nylon braided screen over phase cores; pilot and earth cores are not screened
Lay-upAll cores laid up in contact with each other around an elastomeric cradle
LiterieRubber based bedding compound
GaineHeavy-duty chloroprene outer sheath
Agencement de baseThree screened phase cores, one unscreened pilot and one unscreened earth core

Do not use the drawing as a substitute for the dimensional tables. Confirm the cable end preparation, screen and earth termination, armour bonding and machine interface with the equipment documentation before installation.

Applications

Type 44 applications

Type 44 mining cable application with hand-held drilling equipment underground
Media-library application scene showing hand-held drilling equipment underground; used for application context, not as a model-specific construction proof.

The supplied datasheet identifies this cable for hand-held drilling machines in deep mines and on the surface. Google result patterns for the BS 6708 family also separate cables by equipment duty, voltage class, core function and whether the route is armoured, screened, flat or auxiliary. That is why this page keeps the Type 44 construction separate from nearby Type numbers.

  • Primary duty: hand-held drilling machines in deep mines and on the surface.
  • Model boundary: Type 44 is the metallic-screened drill cable; its construction must not be merged with the non-metallic-screened Type 43 page.
  • Project check: match the cable marking, core map, voltage, termination, route geometry and handling method to the machine drawing.
  • Environmental review: confirm the actual mine/quarry conditions and any authority, inspection or documentation requirements; do not infer a certification or material-resistance claim from the model number.

Where a non-metallic conducting screen is specified, compare the Type 43 drill cable and keep the screen construction aligned with the approved drilling-machine documentation.

The cable should be released only after the equipment route, required length, conductor area, core functions and connection details are agreed. If the intended duty is different from the source-listed application, request an engineering review through the quotation process.

Caractéristiques

Type 44 specifications

The summary below identifies the supplied model family. The source-transcribed tables that follow retain the PDF's dimensional, electrical and construction values, including available sizes, resistance, current, diameter, mass, bending or pulling data when the PDF provides them.

Selection itemSource-linked value
ModèleType 44
Tension nominale125/72 V
Tension d'essai1.5 kV
Applicationhand-held drilling machines in deep mines and on the surface
Norme du produitBS 6708

Complete source-transcribed technical tables

Source PDF: BS6708_TYPE_44_125_72V_HANDHELD_DRILLING_MACHINE_CABLE_datasheet.pdf; 3 pages; 6 extracted tables. Values are not recalculated or replaced by third-party values.

Source table 1, PDF page 1
ParamètreValeur
ConducteurElectrolytic, stranded, tinned copper wire, IEC 60228 Class 5
IsolationEPR
SéparateurColored textile tape for core identification
ÉcranTinned copper and nylon braided screen over phase cores; pilot and earth cores are not screened
Lay-upAll cores are laid up in contact with each other
LiterieRubber based bedding compound
Gaine extérieureHeavy duty chloroprene outer sheath
Source table 2, PDF page 1
ParamètreValeur
StandardBS 6708
Tension nominale125/72 V
Tension d'essai1.5 kV
Type de câbleThree phase cores with composite individual screens, one unscreened pilot core and one unscreened earth core laid up around an elastomeric cradle
Source table 1, PDF page 2
CORE DIMENSIONS
Nominal cross sectionPhase / earth / pilot conductorsStranding mmConductor diameter mmInsulation thickness mmTotal screen cross section mm2
5x63x6 / 1x6 / 1x684/0.303.301.0011
Source table 2, PDF page 2
CABLE DETAILS
Nominal cross sectionMin. OD mmMax. OD mmMin. bend radius mmOuter sheath thickness mmMax pulling tension kgfApprox. weight kg/kmCopper weight kg/km
5x624.726.72413.02181150400
Source table 1, PDF page 3
CURRENT RATINGS
Nominal cross sectionContinuous current rating at 25 deg CShort circuit current for 1 s A
5x646908
Source table 2, PDF page 3
ELECTRICAL DETAILS
Nominal cross sectionFPhase and earth conductors Max. DC res. at 20 deg C ohm/kmPilot conductor Max. DC res. at 20 deg C ohm/kmE3 screens in parallel Max. DC res. at 20 deg C ohm/km
5x63.483.4811

Use the table values with the equipment drawing and approved termination plan. If the requested conductor area, current basis, mechanical limit or environmental condition is not listed in the supplied PDF, treat it as a quotation-stage confirmation item.

Normes

Type 44 standards and references

ObjetSource-linked reference
Norme du produitBS 6708
Tension nominale125/72 V
Tension d'essai1.5 kV
Source applicationhand-held drilling machines in deep mines and on the surface

The product page preserves the BS 6708 reference appearing in the supplied PDF. The BSI record currently identifies BS 6708:1998 as withdrawn on 22 May 2026; this status note is a standards-reference update, not a claim that the product is currently certified or approved. See the official BSI BS 6708 scope record for the published status.

For an RFQ, state the required standard documents, inspection scope, test report, cable marking, destination rules and any replacement-equivalence requirement. The model number alone does not establish legal installation compliance.

Comparer par fonction

Options de câbles associées

Comparez ces options de câbles en fonction de la combinaison de services, du mouvement, de la charge, de la tension et des exigences de transmission.

devis basé sur l'ingénierie

Demandez une recommandation et un devis pour un câble.

Veuillez nous indiquer les services requis, la longueur du câble, les contraintes mécaniques, l'environnement, le type de terminaison et la quantité. Notre équipe examinera votre demande avant de vous établir un devis.

  • Veuillez inclure le nom du produit ou son SKU, ainsi que la longueur et la quantité de câble requises.
  • Joignez une fiche technique, un dessin ou une fiche de spécifications si disponible.

    Facultatif : joindre une spécification de câble, un dessin, une fiche technique ou une image du produit (PDF, DOC, DOCX, XLS, XLSX, CSV, JPG ou PNG ; maximum 10 Mo).

    En soumettant ce formulaire, vous acceptez que TEBAOFLEX utilise vos coordonnées et les fichiers fournis pour examiner votre demande et y répondre. Les fichiers servent à l'établissement du devis et aux échanges techniques relatifs à votre demande. Consultez notre politique de confidentialité. politique de confidentialité pour obtenir des informations à jour sur le traitement et la conservation des données.

    * Champs obligatoires. Veuillez inclure les détails du câble principal ou de l'application pour examen.