احصل على عرض سعر
كابلات التعدين وحفر الأنفاق تيباوفليكس

NTSKCGWÖU 0.6/1 (1.2) kV Mining Loader Cable

NTSKCGWÖU cable is a 0.6/1 (1.2) kV mining loader cable for stated connections to material-handling machinery in mines and other industrial applications.

  • بناء: tinned class 5 copper, EPR, Kevlar reinforcement and 5GM5 sheaths
  • Core system: three power, one earth and two pilot cores
  • Operating range: −50°C to +90°C
  • Minimum bend radius: 4 × cable diameter
  • المرجع القياسي: DIN VDE 0250 الجزء 813

Request a quote with the NTSKCGWÖU configuration, loader connection and route details.

معلومات المنتج
ماركة
تيباوفليكس
نظرة عامة على المنتج

NTSKCGWÖU 0.6/1 (1.2) kV mining loader cable

TEBAOFLEX NTSKCGWÖU is a flexible mining loader cable for connecting material-handling machinery, including loaders, in mines and for related industrial applications. The supplied construction is designed around three power cores, one earth core and two pilot cores, with Kevlar reinforcement at the centre. It combines flexible class 5 tinned copper conductors, EPR insulation, a semi-conductive core covering, a 5GM5 internal and outer sheath system, and a polyamide anti-torsion braid.

The NTSKCGWÖU cable information supplied for this page identifies resistance to tear, impact, abrasion and torsion, together with flame-retardant, oil, UV, sunlight, ozone and weather resistance. These properties support demanding mobile mine-equipment routes, but the final selection must still account for the actual voltage system, machine connection, route, bending, tensile loading, termination method and local site requirements.

  • Stated use: mine loaders, material-handling equipment and other industrial machinery.
  • الترتيب الأساسي: three power, one earth and two pilot cores with central Kevlar reinforcement.
  • نطاق درجة الحرارة: −50°C to +90°C.
  • Supplied configurations: 3×16 + 1×6 + 2×6P through 3×50 + 1×10 + 2×10P.

للعائلات ذات الصلة من الكابلات. نطاق كابلات التعدين والأنفاق for related constructions. Send your NTSKCGWÖU core size, machine type, route, length, quantity and documentation requirements for an engineering-led quotation.

بناء

NTSKCGWÖU construction

The supplied NTSKCGWÖU construction places three power cores, one earth core and two pilot cores on a cradle separator with Kevlar reinforcement in the centre. Semi-conductive and anti-torsion layers support the stated mobile mining duty.

NTSKCGWÖU mining loader cable cutaway showing three power cores, a central reinforcement and black outer sheath
NTSKCGWÖU cable construction view; confirm the final approved core arrangement before production.
عنصر البناءSupplied NTSKCGWÖU reference
الموصلاتAnnealed flexible stranded tin-coated copper, class 5 to IEC 60228
فاصلSuitable semi-conductive tape between conductor and insulation, where needed
العزلEthylene-propylene rubber (EPR), type 3GI3 to DIN VDE 0207 Part 20
النوى التجريبيةClass 5 tinned copper conductors with EPR insulation
Earth coreClass 5 tinned copper covered with semi-conductive compound
التجميع الأساسيThree power, one earth and two pilot cores on cradle separator with Kevlar centre reinforcement
Core coveringSemi-conductive layer over the core assembly
Internal / outer sheathSynthetic thermosetting compound type 5GM5 to DIN VDE 0207 Part 21
جديلة مقاومة للالتواءPolyamide-thread braid between internal and outer sheath layers
Outer jacket colourأسود
التطبيقات

السيارات:

NTSKCGWÖU is supplied for the stated connection of material-handling machines, including loaders in mines, and for other industrial applications. The cable’s tear, impact, abrasion and torsion resistance are relevant selection factors where a mobile machine route is exposed to handling and contact conditions.

Underground mining loader connected by trailing cable in a mine tunnel, illustrating NTSKCGWÖU cable selection
Underground mining-loader environment illustrating the stated NTSKCGWÖU application.

Selection checks

  • Confirm the loader voltage, power-core size, earth and pilot-core functions against the approved machine wiring schedule.
  • Check the route for bending, tensile load, crushing risk, heat, oil exposure and termination movement.
  • Use the supplied 4 × D bending-radius requirement and −50°C to +90°C temperature range within the project’s complete installation assessment.
  • State the requested NTSKCGWÖU length, marking, drum packing and test-documentation requirements with the enquiry.

Standard packing is 500 m on drums; other packing and delivery forms are available on request.

تحديد

NTSKCGWÖU specifications

The following nominal data are transcribed from the supplied NTSKCGWÖU product information. Confirm the selected configuration and project calculations before order release.

Dimensions and electrical reference data

Number of cores × cross-sectionOverall diameter min. / approx. / max.الوزن التقريبيConductor resistance at 20°CInductive reactance at 50 HzالسعةShort-circuit capacityCurrent-carrying capacity at 30°C
3×16 + 1×6 + 2×6P32.0 / 32.3 / 35.0 mm1,526 kg/km1.24 أوم/كم0.089 Ω/km0.39 μF/km2.3 kA99 أ
3×25 + 1×6 + 2×6P37.0 / 37.4 / 40.0 mm2,097 kg/km0.795 أوم/كم0.088 Ω/km0.42 ميكروفاراد/كم3.6 kA131 أ
3×50 + 1×10 + 2×10P44.0 / 45.1 / 50.0 mm3,357 kg/km0.565 أوم/كم0.082 أوم/كم0.32 μF/km6.4 kA202 أ

Performance parameters

Temperature range / maximum conductor temperature−50°C to +90°C / 90°C
درجة حرارة موصل الدائرة القصيرة250 درجة مئوية
نصف قطر الانحناء الأدنى4 × D, where D is cable diameter
الحمل الشدّيUp to 20 N/mm²
Outer-sheath tensile strength / elongation at breakMinimum 15 N/mm² / minimum 300%
Outer-sheath tear resistanceMinimum 30 N/mm
Air ageing100°C, 168 h; change in tensile strength ±30%, elongation at break ±40%
Oil ageing100°C, 24 h; change in tensile strength and elongation at break ±40%
المعايير

المرجع / العنصر

The supplied NTSKCGWÖU information cites the following construction, test and reference standards.

Cable standard referenceDIN VDE 0250 الجزء 813
Conductor referenceIEC 60228, class 5
EPR insulation referenceDIN VDE 0207 Part 20, type 3GI3
Sheath-material referenceDIN VDE 0207 Part 21, type 5GM5
مرجع سعة حمل التيارDIN VDE 0298 الجزء 4
مرجع مقاومة الزيتDIN VDE 811-2-1, p.10
Voltage test referenceTest in air between power, earth conductors and screen in accordance with DIN VDE 0250 Part 813

Include the required standard edition, project test scope and documentation requirements in the purchase enquiry.

قارن حسب الرسوم

خيارات الكابلات ذات الصلة

قارن بين خيارات الكابلات هذه حسب مجموعة الخدمات، والحركة، والحمل، والجهد، ومتطلبات الإرسال.

عرض أسعار قائم على الهندسة

اطلب توصية بشأن الكابلات وعرض سعر

يرجى إرسال الخدمات المطلوبة، وطول الكابل، والقدرات الميكانيكية، والبيئة، ونوع التوصيلات، والكمية. سيقوم فريقنا بمراجعة الطلب قبل تقديم عرض السعر.

  • يرجى تضمين اسم المنتج أو رمز المنتج (SKU) بالإضافة إلى طول الكابل المطلوب وكميته.
  • أرفق المواصفات أو الرسم أو ورقة البيانات عند توفرها.

    اختياري: إرفاق مواصفات الكابل أو الرسم أو ورقة البيانات أو صورة المنتج (PDF، DOC، DOCX، XLS، XLSX، CSV، JPG أو PNG؛ بحد أقصى 10 ميجابايت).

    بإرسال هذا النموذج، فإنك توافق على أن تستخدم شركة TEBAOFLEX معلومات الاتصال والملفات المُقدمة لمراجعة استفسارك والرد عليه. تُستخدم الملفات لإعداد عروض الأسعار والتواصل الهندسي المتعلق بطلبك. راجع سياسة ملفاتنا سياسة الخصوصية للحصول على معلومات حديثة حول معالجة البيانات والاحتفاظ بها.

    * الحقول المطلوبة. يرجى تضمين تفاصيل الكابل الرئيسي أو التطبيق للمراجعة.