Получить ценовое предложение
КАБЕЛИ ДЛЯ ГОРНОДОБЫВАЮЩЕЙ ПРОМЫШЛЕННОСТИ И ПРОКЛАДКИ ТОННЕЛЕЙ ТЕБАОФЛЕКС

NTSKCGWÖU 0.6/1 (1.2) kV Mining Loader Cable

NTSKCGWÖU cable is a 0.6/1 (1.2) kV mining loader cable for stated connections to material-handling machinery in mines and other industrial applications.

  • Строительство: tinned class 5 copper, EPR, Kevlar reinforcement and 5GM5 sheaths
  • Core system: three power, one earth and two pilot cores
  • Operating range: −50°C to +90°C
  • Minimum bend radius: 4 × cable diameter
  • Стандартный справочник: DIN VDE 0250 Часть 813

Request a quote with the NTSKCGWÖU configuration, loader connection and route details.

Информация о продукте
Бренд
ТЕБАОФЛЕКС
Обзор продукта

NTSKCGWÖU 0.6/1 (1.2) kV mining loader cable

TEBAOFLEX NTSKCGWÖU is a flexible mining loader cable for connecting material-handling machinery, including loaders, in mines and for related industrial applications. The supplied construction is designed around three power cores, one earth core and two pilot cores, with Kevlar reinforcement at the centre. It combines flexible class 5 tinned copper conductors, EPR insulation, a semi-conductive core covering, a 5GM5 internal and outer sheath system, and a polyamide anti-torsion braid.

The NTSKCGWÖU cable information supplied for this page identifies resistance to tear, impact, abrasion and torsion, together with flame-retardant, oil, UV, sunlight, ozone and weather resistance. These properties support demanding mobile mine-equipment routes, but the final selection must still account for the actual voltage system, machine connection, route, bending, tensile loading, termination method and local site requirements.

  • Stated use: mine loaders, material-handling equipment and other industrial machinery.
  • Основная структура: three power, one earth and two pilot cores with central Kevlar reinforcement.
  • Диапазон температур: −50°C to +90°C.
  • Supplied configurations: 3×16 + 1×6 + 2×6P through 3×50 + 1×10 + 2×10P.

См. Ассортимент кабелей для горнодобывающей и туннельной промышленности for related constructions. Send your NTSKCGWÖU core size, machine type, route, length, quantity and documentation requirements for an engineering-led quotation.

Конструкция

NTSKCGWÖU construction

The supplied NTSKCGWÖU construction places three power cores, one earth core and two pilot cores on a cradle separator with Kevlar reinforcement in the centre. Semi-conductive and anti-torsion layers support the stated mobile mining duty.

NTSKCGWÖU mining loader cable cutaway showing three power cores, a central reinforcement and black outer sheath
NTSKCGWÖU cable construction view; confirm the final approved core arrangement before production.
Строительный элементSupplied NTSKCGWÖU reference
ДирижерыAnnealed flexible stranded tin-coated copper, class 5 to IEC 60228
СепараторSuitable semi-conductive tape between conductor and insulation, where needed
ИзоляцияEthylene-propylene rubber (EPR), type 3GI3 to DIN VDE 0207 Part 20
Пилотные ядраClass 5 tinned copper conductors with EPR insulation
Earth coreClass 5 tinned copper covered with semi-conductive compound
Основной узелThree power, one earth and two pilot cores on cradle separator with Kevlar centre reinforcement
Core coveringSemi-conductive layer over the core assembly
Internal / outer sheathSynthetic thermosetting compound type 5GM5 to DIN VDE 0207 Part 21
Противоторсионная оплеткаPolyamide-thread braid between internal and outer sheath layers
Outer jacket colourЧерный
Применения

Применения

NTSKCGWÖU is supplied for the stated connection of material-handling machines, including loaders in mines, and for other industrial applications. The cable’s tear, impact, abrasion and torsion resistance are relevant selection factors where a mobile machine route is exposed to handling and contact conditions.

Underground mining loader connected by trailing cable in a mine tunnel, illustrating NTSKCGWÖU cable selection
Underground mining-loader environment illustrating the stated NTSKCGWÖU application.

Selection checks

  • Confirm the loader voltage, power-core size, earth and pilot-core functions against the approved machine wiring schedule.
  • Check the route for bending, tensile load, crushing risk, heat, oil exposure and termination movement.
  • Use the supplied 4 × D bending-radius requirement and −50°C to +90°C temperature range within the project’s complete installation assessment.
  • State the requested NTSKCGWÖU length, marking, drum packing and test-documentation requirements with the enquiry.

Standard packing is 500 m on drums; other packing and delivery forms are available on request.

Спецификации

NTSKCGWÖU specifications

The following nominal data are transcribed from the supplied NTSKCGWÖU product information. Confirm the selected configuration and project calculations before order release.

Dimensions and electrical reference data

Number of cores × cross-sectionOverall diameter min. / approx. / max.Приблизительный весConductor resistance at 20°CInductive reactance at 50 HzЕмкостьShort-circuit capacityCurrent-carrying capacity at 30°C
3×16 + 1×6 + 2×6P32.0 / 32.3 / 35.0 mm1,526 kg/km1,24 Ом/км0.089 Ω/km0.39 μF/km2.3 kA99 А
3×25 + 1×6 + 2×6P37.0 / 37.4 / 40.0 mm2,097 kg/km0,795 Ом/км0.088 Ω/km0,42 мкФ/км3.6 kA131 А
3×50 + 1×10 + 2×10P44.0 / 45.1 / 50.0 mm3,357 kg/km0,565 Ом/км0,082 Ом/км0.32 μF/km6.4 kA202 А

Performance parameters

Temperature range / maximum conductor temperature−50°C to +90°C / 90°C
Температура проводника короткого замыкания250°C
Минимальный радиус изгиба4 × D, where D is cable diameter
Растягивающая нагрузкаUp to 20 N/mm²
Outer-sheath tensile strength / elongation at breakMinimum 15 N/mm² / minimum 300%
Outer-sheath tear resistanceMinimum 30 N/mm
Air ageing100°C, 168 h; change in tensile strength ±30%, elongation at break ±40%
Oil ageing100°C, 24 h; change in tensile strength and elongation at break ±40%
Стандарты

Стандарты

The supplied NTSKCGWÖU information cites the following construction, test and reference standards.

Cable standard referenceDIN VDE 0250 Часть 813
Conductor referenceIEC 60228, class 5
EPR insulation referenceDIN VDE 0207 Part 20, type 3GI3
Sheath-material referenceDIN VDE 0207 Part 21, type 5GM5
эталонная пропускная способность по токуDIN VDE 0298 Часть 4
Справочная информация по маслостойкостиDIN VDE 811-2-1, p.10
Voltage test referenceTest in air between power, earth conductors and screen in accordance with DIN VDE 0250 Part 813

Include the required standard edition, project test scope and documentation requirements in the purchase enquiry.

Сравнение по пошлинам

Варианты кабелей по теме

Сравните эти варианты кабелей по сочетанию услуг, типу перемещения, нагрузке, напряжению и требованиям к передаче.

Коммерческое предложение, составленное инженерами

Запросите рекомендации по выбору кабеля и коммерческое предложение.

Укажите необходимые услуги, длину кабеля, механические характеристики, условия эксплуатации, тип разъемов и количество. Наша команда рассмотрит заявку перед составлением коммерческого предложения.

  • Укажите название продукта или артикул, а также необходимую длину кабеля и количество.
  • При наличии приложите техническое задание, чертеж или спецификацию.

    Необязательно: прикрепите спецификацию кабеля, чертёж, паспорт или изображение изделия (PDF, DOC, DOCX, XLS, XLSX, CSV, JPG или PNG; максимум 10 МБ).

    Эти ссылки и сведения об испытаниях взяты из предоставленного комплекта документации. Формулировки сохранены в соответствии с источником: ссылка на стандарт или метод испытаний не представляется сертификатом изделия, если источник прямо так её не называет. Ссылка / позиция Предоставленная формулировка

    SAE J1128