Obtenir un devis
CÂBLES MINIERS ET DE TUNNELAGE Modèle / construction

NTSKCGWÖU 0.6/1 (1.2) kV Mining Loader Cable

NTSKCGWÖU cable is a 0.6/1 (1.2) kV mining loader cable for stated connections to material-handling machinery in mines and other industrial applications.

  • Construction: tinned class 5 copper, EPR, Kevlar reinforcement and 5GM5 sheaths
  • Core system: three power, one earth and two pilot cores
  • Operating range: −50°C to +90°C
  • Minimum bend radius: 4 × cable diameter
  • Référence standard : DIN VDE 0250 Partie 813

Request a quote with the NTSKCGWÖU configuration, loader connection and route details.

Informations sur le produit
Marque
Modèle / construction
Présentation du produit

NTSKCGWÖU 0.6/1 (1.2) kV mining loader cable

TEBAOFLEX NTSKCGWÖU is a flexible mining loader cable for connecting material-handling machinery, including loaders, in mines and for related industrial applications. The supplied construction is designed around three power cores, one earth core and two pilot cores, with Kevlar reinforcement at the centre. It combines flexible class 5 tinned copper conductors, EPR insulation, a semi-conductive core covering, a 5GM5 internal and outer sheath system, and a polyamide anti-torsion braid.

The NTSKCGWÖU cable information supplied for this page identifies resistance to tear, impact, abrasion and torsion, together with flame-retardant, oil, UV, sunlight, ozone and weather resistance. These properties support demanding mobile mine-equipment routes, but the final selection must still account for the actual voltage system, machine connection, route, bending, tensile loading, termination method and local site requirements.

  • Stated use: mine loaders, material-handling equipment and other industrial machinery.
  • Agencement de base : three power, one earth and two pilot cores with central Kevlar reinforcement.
  • Plage de températures : −50°C to +90°C.
  • Supplied configurations: 3×16 + 1×6 + 2×6P through 3×50 + 1×10 + 2×10P.

Voir le gamme de câbles pour l'exploitation minière et le creusement de tunnels for related constructions. Send your NTSKCGWÖU core size, machine type, route, length, quantity and documentation requirements for an engineering-led quotation.

Construction

NTSKCGWÖU construction

The supplied NTSKCGWÖU construction places three power cores, one earth core and two pilot cores on a cradle separator with Kevlar reinforcement in the centre. Semi-conductive and anti-torsion layers support the stated mobile mining duty.

NTSKCGWÖU mining loader cable cutaway showing three power cores, a central reinforcement and black outer sheath
NTSKCGWÖU cable construction view; confirm the final approved core arrangement before production.
Élément de constructionSupplied NTSKCGWÖU reference
ConducteursAnnealed flexible stranded tin-coated copper, class 5 to IEC 60228
SéparateurSuitable semi-conductive tape between conductor and insulation, where needed
IsolationEthylene-propylene rubber (EPR), type 3GI3 to DIN VDE 0207 Part 20
noyaux pilotesClass 5 tinned copper conductors with EPR insulation
Earth coreClass 5 tinned copper covered with semi-conductive compound
Assemblage de baseThree power, one earth and two pilot cores on cradle separator with Kevlar centre reinforcement
Core coveringSemi-conductive layer over the core assembly
Internal / outer sheathSynthetic thermosetting compound type 5GM5 to DIN VDE 0207 Part 21
tresse anti-torsionPolyamide-thread braid between internal and outer sheath layers
Outer jacket colourNoir
Applications

Applications

NTSKCGWÖU is supplied for the stated connection of material-handling machines, including loaders in mines, and for other industrial applications. The cable’s tear, impact, abrasion and torsion resistance are relevant selection factors where a mobile machine route is exposed to handling and contact conditions.

Underground mining loader connected by trailing cable in a mine tunnel, illustrating NTSKCGWÖU cable selection
Underground mining-loader environment illustrating the stated NTSKCGWÖU application.

Selection checks

  • Confirm the loader voltage, power-core size, earth and pilot-core functions against the approved machine wiring schedule.
  • Check the route for bending, tensile load, crushing risk, heat, oil exposure and termination movement.
  • Use the supplied 4 × D bending-radius requirement and −50°C to +90°C temperature range within the project’s complete installation assessment.
  • State the requested NTSKCGWÖU length, marking, drum packing and test-documentation requirements with the enquiry.

Standard packing is 500 m on drums; other packing and delivery forms are available on request.

Caractéristiques

NTSKCGWÖU specifications

The following nominal data are transcribed from the supplied NTSKCGWÖU product information. Confirm the selected configuration and project calculations before order release.

Dimensions and electrical reference data

Number of cores × cross-sectionOverall diameter min. / approx. / max.Poids approximatifConductor resistance at 20°CInductive reactance at 50 HzCapacitanceShort-circuit capacityCurrent-carrying capacity at 30°C
3×16 + 1×6 + 2×6P32.0 / 32.3 / 35.0 mm1,526 kg/km1,24 Ω/km0.089 Ω/km0.39 μF/km2.3 kA99 A
3×25 + 1×6 + 2×6P37.0 / 37.4 / 40.0 mm2,097 kg/km0,795 Ω/km0.088 Ω/km0,42 μF/km3.6 kA131 A
3×50 + 1×10 + 2×10P44.0 / 45.1 / 50.0 mm3,357 kg/km0,565 Ω/km0,082 Ω/km0.32 μF/km6.4 kA202 A

Performance parameters

Temperature range / maximum conductor temperature−50°C to +90°C / 90°C
température du conducteur en court-circuit250°C
rayon de courbure minimal4 × D, where D is cable diameter
Charge de tractionUp to 20 N/mm²
Outer-sheath tensile strength / elongation at breakMinimum 15 N/mm² / minimum 300%
Outer-sheath tear resistanceMinimum 30 N/mm
Air ageing100°C, 168 h; change in tensile strength ±30%, elongation at break ±40%
Oil ageing100°C, 24 h; change in tensile strength and elongation at break ±40%
Normes

Normes

The supplied NTSKCGWÖU information cites the following construction, test and reference standards.

Cable standard referenceDIN VDE 0250 Partie 813
Conductor referenceIEC 60228, class 5
EPR insulation referenceDIN VDE 0207 Part 20, type 3GI3
Sheath-material referenceDIN VDE 0207 Part 21, type 5GM5
Référence de capacité de transport de courantDIN VDE 0298 Partie 4
Référence de résistance à l'huileDIN VDE 811-2-1, p.10
Voltage test referenceTest in air between power, earth conductors and screen in accordance with DIN VDE 0250 Part 813

Include the required standard edition, project test scope and documentation requirements in the purchase enquiry.

Comparer par fonction

Options de câbles associées

Comparez ces options de câbles en fonction de la combinaison de services, du mouvement, de la charge, de la tension et des exigences de transmission.

devis basé sur l'ingénierie

Demandez une recommandation et un devis pour un câble.

Veuillez nous indiquer les services requis, la longueur du câble, les contraintes mécaniques, l'environnement, le type de terminaison et la quantité. Notre équipe examinera votre demande avant de vous établir un devis.

  • Veuillez inclure le nom du produit ou son SKU, ainsi que la longueur et la quantité de câble requises.
  • Joignez une fiche technique, un dessin ou une fiche de spécifications si disponible.

    Facultatif : joindre une spécification de câble, un dessin, une fiche technique ou une image du produit (PDF, DOC, DOCX, XLS, XLSX, CSV, JPG ou PNG ; maximum 10 Mo).

    En soumettant ce formulaire, vous acceptez que TEBAOFLEX utilise vos coordonnées et les fichiers fournis pour examiner votre demande et y répondre. Les fichiers servent à l'établissement du devis et aux échanges techniques relatifs à votre demande. Consultez notre politique de confidentialité. politique de confidentialité pour obtenir des informations à jour sur le traitement et la conservation des données.

    * Champs obligatoires. Veuillez inclure les détails du câble principal ou de l'application pour examen.