
Type 730 BS 6708 3800/6600 V Screened Trailing Cable
Type 730 mining cable for large-machine trailing power supply, with the source-defined 3800/6600 V rating and 15 kV test reference.
- Model: Type 730
- Conductor and insulation: flexible tinned copper with the insulation and core construction listed for this model in the supplied PDF
- Screen, pilot, earth and armour arrangement preserved from the source datasheet
- Heavy-duty chloroprene or PCP outer protection as listed for this model
- Original Type datasheet available as the product download
Send the equipment, voltage, conductor area, route, quantity and document requirements for an RFQ.
Type 730 for large-machine trailing power supply
Type 730 mining cable is specified in the supplied BS 6708 datasheet for large-machine trailing power supply. This page keeps the source-listed voltage, test reference, core functions and dimensional tables together so a procurement engineer can compare the requested model against the cable marking and the equipment connection. The editorial focus is the non-armoured screened 6.6 kV trailing route, not a generic promise of performance.
The supplied construction uses three individually screened EPR-insulated cores laid up around a bare copper earth core where fitted, with rubber bedding and a heavy-duty chloroprene outer sheath. That arrangement matters because Type 730 is non-armoured in the supplied construction; larger sizes include a central bare earth core. The family should therefore be selected by model, core function and installation route as well as by voltage. The مجموعة كابلات التعدين والأنفاق provides the wider TEBAOFLEX product context.
- اختر حسب: confirm whether the machine route requires the non-armoured Type 730 construction or the armoured Type 621/630/631 alternatives.
- تأكيد قبل الطلب: existing sheath marking, conductor area, cable length, route, support or handling system, terminations and the required inspection documents.
- Do not infer: values not listed in the supplied PDF, such as a different current basis, water/oil/UV performance, certification scope or mechanical interchangeability.
Before changing a high-voltage trailing cable model, consult the BS 6708 mining cable replacement guide and confirm whether the required screen and armour arrangement remains the same.
For a technical quotation, send the equipment nameplate or existing cable marking, voltage and size requirement, installation conditions, quantity, destination and any project-specific test or documentation requirement.
Type 730 construction
The cross-section below is the supplied construction drawing for Type 730. The ordering decision is driven by Type 730 is non-armoured in the supplied construction; larger sizes include a central bare earth core.

Source-listed construction
| عنصر التركيب | القيمة المدرجة في المصدر |
|---|---|
| موصل | Electrolytic stranded tinned copper wire, IEC 60228 Class 5 |
| العزل | عزل EPR |
| شاشة | Tinned copper and nylon braided screen over phase cores |
| التسديدة السهلة | All cores laid up in contact around the bare copper earth core where fitted |
| أغطية الفراش | Rubber based bedding compound |
| غمد | Heavy-duty chloroprene outer sheath |
| الترتيب الأساسي | Three individually screened cores; larger sizes include a central bare earth core |
Do not use the drawing as a substitute for the dimensional tables. Confirm the cable end preparation, screen and earth termination, armour bonding and machine interface with the equipment documentation before installation.
Type 730 applications

The supplied datasheet identifies this cable for large-machine trailing power supply. Google result patterns for the BS 6708 family also separate cables by equipment duty, voltage class, core function and whether the route is armoured, screened, flat or auxiliary. That is why this page keeps the Type 730 construction separate from nearby Type numbers.
- Primary duty: large-machine trailing power supply.
- Model boundary: Type 730 is non-armoured in the supplied construction; larger sizes include a central bare earth core.
- Project check: match the cable marking, core map, voltage, termination, route geometry and handling method to the machine drawing.
- Environmental review: confirm the actual mine/quarry conditions and any authority, inspection or documentation requirements; do not infer a certification or material-resistance claim from the model number.
Where the design instead requires the Type 621 armoured arrangement, use the Type 621 mining cable page as a structured comparison, not as a direct replacement instruction.
The cable should be released only after the equipment route, required length, conductor area, core functions and connection details are agreed. If the intended duty is different from the source-listed application, request an engineering review through the quotation process.
Type 730 specifications
The summary below identifies the supplied model family. The source-transcribed tables that follow retain the PDF's dimensional, electrical and construction values, including available sizes, resistance, current, diameter, mass, bending or pulling data when the PDF provides them.
| Selection item | Source-linked value |
|---|---|
| نموذج | Type 730 |
| الجهد المقنن | 3800/6600 V |
| جهد الاختبار | 15 كيلو فولت |
| طلب | large-machine trailing power supply |
| معيار المنتج | BS 6708 |
Complete source-transcribed technical tables
Source PDF: BS6708_TYPE_730_3800_6600V_TRAILING_CABLE_datasheet.pdf; 3 pages; 4 extracted tables. Values are not recalculated or replaced by third-party values.
| المعلمة | قيمة |
|---|---|
| موصل | Electrolytic, stranded, tinned copper wire, IEC 60228 Class 5 |
| العزل | تقرير الأداء الإلكتروني |
| شاشة | Tinned copper and nylon braided screen over phase cores |
| التسديدة السهلة | All cores laid up in contact around the bare copper earth core where fitted |
| أغطية الفراش | Rubber based bedding compound |
| الغلاف الخارجي | Heavy duty chloroprene outer sheath |
| المعلمة | قيمة |
|---|---|
| معيار | BS 6708 |
| الجهد المقنن | 3800/6600 V |
| جهد الاختبار | 15 كيلو فولت |
| الترتيب الأساسي | Three individually screened cores; larger sizes include a central bare earth core |
| CABLE DIMENSIONS | ||||||
|---|---|---|---|---|---|---|
| المعلمة | 3x35 | 3x50 | 3x70 | 3x95 | 3x120+16 | 3x150+16 |
| Phase conductor nominal cross section mm2 | 3x35 | 3x50 | 3x70 | 3x95 | 3x120 | 3x150 |
| Phase conductor stranding | 276/0.40 | 396/0.40 | 360/0.50 | 475/0.50 | 608/0.50 | 756/0.50 |
| Phase conductor diameter nominal mm | 8.40 | 10.10 | 11.90 | 13.90 | 15.50 | 17.20 |
| Insulation thickness mm | 5.0 | 5.0 | 5.0 | 5.0 | 5.0 | 5.0 |
| Earth conductor cross section mm2 | - | - | - | - | 1x16 | 1x16 |
| Earth conductor stranding | - | - | - | - | 126/0.40 | 126/0.40 |
| Earth conductor diameter nominal mm | - | - | - | - | 5.50 | 5.50 |
| Outer sheath thickness mm | 6.0 | 6.3 | 6.8 | 7.3 | 7.6 | 8.0 |
| Minimum overall diameter mm | 57.5 | 62.0 | 67.5 | 73.1 | 76.9 | 82.1 |
| Maximum overall diameter mm | 60.5 | 65.0 | 71.4 | 76.9 | 80.9 | 86.0 |
| Minimum bending radius mm | 605 | 650 | 714 | 769 | 809 | 860 |
| Approximate cable weight kg/km | 4800 | 5900 | 7100 | 8500 | 9950 | 11400 |
| Copper weight kg/km | 1300 | 1800 | 2500 | 3250 | 4200 | 5000 |
| ELECTRICAL DETAILS | ||||||
|---|---|---|---|---|---|---|
| المعلمة | 3x35 | 3x50 | 3x70 | 3x95 | 3x120+16 | 3x150+16 |
| Continuous current rating at 25 deg C ambient A | 135 | 170 | 205 | 250 | 295 | 320 |
| Phase conductor DC resistance at 20 deg C ohm/km | 0.565 | 0.393 | 0.277 | 0.210 | 0.164 | 0.132 |
| Three screens and earth in parallel DC resistance ohm/km | 0.81 | 0.78 | 0.55 | 0.42 | 0.32 | 0.26 |
Use the table values with the equipment drawing and approved termination plan. If the requested conductor area, current basis, mechanical limit or environmental condition is not listed in the supplied PDF, treat it as a quotation-stage confirmation item.
Type 730 standards and references
| الموضوع | Source-linked reference |
|---|---|
| معيار المنتج | BS 6708 |
| الجهد المقنن | 3800/6600 V |
| جهد الاختبار | 15 كيلو فولت |
| Source application | large-machine trailing power supply |
The product page preserves the BS 6708 reference appearing in the supplied PDF. The BSI record currently identifies BS 6708:1998 as withdrawn on 22 May 2026; this status note is a standards-reference update, not a claim that the product is currently certified or approved. See the official BSI BS 6708 scope record for the published status.
For an RFQ, state the required standard documents, inspection scope, test report, cable marking, destination rules and any replacement-equivalence requirement. The model number alone does not establish legal installation compliance.
خيارات الكابلات ذات الصلة
قارن بين خيارات الكابلات هذه حسب مجموعة الخدمات، والحركة، والحمل، والجهد، ومتطلبات الإرسال.
كابل طاقة التعدين المدرع والمحمي من النوع TYPE260
خيار كابل ذي صلة لتطبيق أو وظيفة مختلفة.
عرض المنتجكابل منجم فحم تحت الأرض من النوع 240، من 1.1 كيلو فولت إلى 11 كيلو فولت
خيار كابل ذي صلة لتطبيق أو وظيفة مختلفة.
عرض المنتجاطلب توصية بشأن الكابلات وعرض سعر
يرجى إرسال الخدمات المطلوبة، وطول الكابل، والقدرات الميكانيكية، والبيئة، ونوع التوصيلات، والكمية. سيقوم فريقنا بمراجعة الطلب قبل تقديم عرض السعر.
- يرجى تضمين اسم المنتج أو رمز المنتج (SKU) بالإضافة إلى طول الكابل المطلوب وكميته.
- أرفق المواصفات أو الرسم أو ورقة البيانات عند توفرها.

