Obtenir un devis
CÂBLES MINIERS ET DE TUNNELAGE Modèle / construction

Type 730 BS 6708 3800/6600 V Screened Trailing Cable

Type 730 mining cable for large-machine trailing power supply, with the source-defined 3800/6600 V rating and 15 kV test reference.

  • Model: Type 730
  • Conductor and insulation: flexible tinned copper with the insulation and core construction listed for this model in the supplied PDF
  • Screen, pilot, earth and armour arrangement preserved from the source datasheet
  • Heavy-duty chloroprene or PCP outer protection as listed for this model
  • Original Type datasheet available as the product download

Send the equipment, voltage, conductor area, route, quantity and document requirements for an RFQ.

Informations sur le produit
Marque
Modèle / construction
Présentation du produit

Type 730 for large-machine trailing power supply

Type 730 mining cable is specified in the supplied BS 6708 datasheet for large-machine trailing power supply. This page keeps the source-listed voltage, test reference, core functions and dimensional tables together so a procurement engineer can compare the requested model against the cable marking and the equipment connection. The editorial focus is the non-armoured screened 6.6 kV trailing route, not a generic promise of performance.

The supplied construction uses three individually screened EPR-insulated cores laid up around a bare copper earth core where fitted, with rubber bedding and a heavy-duty chloroprene outer sheath. That arrangement matters because Type 730 is non-armoured in the supplied construction; larger sizes include a central bare earth core. The family should therefore be selected by model, core function and installation route as well as by voltage. The gamme de câbles pour l'exploitation minière et le creusement de tunnels provides the wider TEBAOFLEX product context.

  • Choisir par : confirm whether the machine route requires the non-armoured Type 730 construction or the armoured Type 621/630/631 alternatives.
  • Confirmez avant de commander : existing sheath marking, conductor area, cable length, route, support or handling system, terminations and the required inspection documents.
  • Do not infer: values not listed in the supplied PDF, such as a different current basis, water/oil/UV performance, certification scope or mechanical interchangeability.

Before changing a high-voltage trailing cable model, consult the BS 6708 mining cable replacement guide and confirm whether the required screen and armour arrangement remains the same.

For a technical quotation, send the equipment nameplate or existing cable marking, voltage and size requirement, installation conditions, quantity, destination and any project-specific test or documentation requirement.

Construction

Type 730 construction

The cross-section below is the supplied construction drawing for Type 730. The ordering decision is driven by Type 730 is non-armoured in the supplied construction; larger sizes include a central bare earth core.

Type 730 cable cross-section showing the supplied power, pilot, earth, screen and protection arrangement
Supplied Type 730 cross-section; the exact core and armour arrangement must be checked against the product datasheet.

Source-listed construction

Élément de constructionValeur indiquée dans la source
ConducteurElectrolytic stranded tinned copper wire, IEC 60228 Class 5
IsolationIsolation EPR
ÉcranTinned copper and nylon braided screen over phase cores
Lay-upAll cores laid up in contact around the bare copper earth core where fitted
LiterieRubber based bedding compound
GaineHeavy-duty chloroprene outer sheath
Agencement de baseThree individually screened cores; larger sizes include a central bare earth core

Do not use the drawing as a substitute for the dimensional tables. Confirm the cable end preparation, screen and earth termination, armour bonding and machine interface with the equipment documentation before installation.

Applications

Type 730 applications

Type 730 mining cable application with surface mining excavator equipment
Media-library application scene showing surface mining excavator equipment; used for application context, not as a model-specific construction proof.

The supplied datasheet identifies this cable for large-machine trailing power supply. Google result patterns for the BS 6708 family also separate cables by equipment duty, voltage class, core function and whether the route is armoured, screened, flat or auxiliary. That is why this page keeps the Type 730 construction separate from nearby Type numbers.

  • Primary duty: large-machine trailing power supply.
  • Model boundary: Type 730 is non-armoured in the supplied construction; larger sizes include a central bare earth core.
  • Project check: match the cable marking, core map, voltage, termination, route geometry and handling method to the machine drawing.
  • Environmental review: confirm the actual mine/quarry conditions and any authority, inspection or documentation requirements; do not infer a certification or material-resistance claim from the model number.

Where the design instead requires the Type 621 armoured arrangement, use the Type 621 mining cable page as a structured comparison, not as a direct replacement instruction.

The cable should be released only after the equipment route, required length, conductor area, core functions and connection details are agreed. If the intended duty is different from the source-listed application, request an engineering review through the quotation process.

Caractéristiques

Type 730 specifications

The summary below identifies the supplied model family. The source-transcribed tables that follow retain the PDF's dimensional, electrical and construction values, including available sizes, resistance, current, diameter, mass, bending or pulling data when the PDF provides them.

Selection itemSource-linked value
ModèleType 730
Tension nominale3800/6600 V
Tension d'essai15 kV
Applicationlarge-machine trailing power supply
Norme du produitBS 6708

Complete source-transcribed technical tables

Source PDF: BS6708_TYPE_730_3800_6600V_TRAILING_CABLE_datasheet.pdf; 3 pages; 4 extracted tables. Values are not recalculated or replaced by third-party values.

Source table 1, PDF page 1
ParamètreValeur
ConducteurElectrolytic, stranded, tinned copper wire, IEC 60228 Class 5
IsolationEPR
ÉcranTinned copper and nylon braided screen over phase cores
Lay-upAll cores laid up in contact around the bare copper earth core where fitted
LiterieRubber based bedding compound
gaine extérieureHeavy duty chloroprene outer sheath
Source table 2, PDF page 1
ParamètreValeur
StandardBS 6708
Tension nominale3800/6600 V
Tension d'essai15 kV
Agencement de baseThree individually screened cores; larger sizes include a central bare earth core
Source table 1, PDF page 2
CABLE DIMENSIONS
Paramètre3x353x503x703x953x120+163x150+16
Phase conductor nominal cross section mm23x353x503x703x953x1203x150
Phase conductor stranding276/0.40396/0.40360/0.50475/0.50608/0.50756/0.50
Phase conductor diameter nominal mm8.4010.1011.9013.9015.5017.20
Insulation thickness mm5.05.05.05.05.05.0
Earth conductor cross section mm2----1x161x16
Earth conductor stranding----126/0.40126/0.40
Earth conductor diameter nominal mm----5.505.50
Outer sheath thickness mm6.06.36.87.37.68.0
Minimum overall diameter mm57.562.067.573.176.982.1
Maximum overall diameter mm60.565.071.476.980.986.0
Minimum bending radius mm605650714769809860
Approximate cable weight kg/km4800590071008500995011400
Copper weight kg/km130018002500325042005000
Source table 1, PDF page 3
ELECTRICAL DETAILS
Paramètre3x353x503x703x953x120+163x150+16
Continuous current rating at 25 deg C ambient A135170205250295320
Phase conductor DC resistance at 20 deg C ohm/km0.5650.3930.2770.2100.1640.132
Three screens and earth in parallel DC resistance ohm/km0.810.780.550.420.320.26

Use the table values with the equipment drawing and approved termination plan. If the requested conductor area, current basis, mechanical limit or environmental condition is not listed in the supplied PDF, treat it as a quotation-stage confirmation item.

Normes

Type 730 standards and references

ObjetSource-linked reference
Norme du produitBS 6708
Tension nominale3800/6600 V
Tension d'essai15 kV
Source applicationlarge-machine trailing power supply

The product page preserves the BS 6708 reference appearing in the supplied PDF. The BSI record currently identifies BS 6708:1998 as withdrawn on 22 May 2026; this status note is a standards-reference update, not a claim that the product is currently certified or approved. See the official BSI BS 6708 scope record for the published status.

For an RFQ, state the required standard documents, inspection scope, test report, cable marking, destination rules and any replacement-equivalence requirement. The model number alone does not establish legal installation compliance.

Comparer par fonction

Options de câbles associées

Comparez ces options de câbles en fonction de la combinaison de services, du mouvement, de la charge, de la tension et des exigences de transmission.

devis basé sur l'ingénierie

Demandez une recommandation et un devis pour un câble.

Veuillez nous indiquer les services requis, la longueur du câble, les contraintes mécaniques, l'environnement, le type de terminaison et la quantité. Notre équipe examinera votre demande avant de vous établir un devis.

  • Veuillez inclure le nom du produit ou son SKU, ainsi que la longueur et la quantité de câble requises.
  • Joignez une fiche technique, un dessin ou une fiche de spécifications si disponible.

    Facultatif : joindre une spécification de câble, un dessin, une fiche technique ou une image du produit (PDF, DOC, DOCX, XLS, XLSX, CSV, JPG ou PNG ; maximum 10 Mo).

    En soumettant ce formulaire, vous acceptez que TEBAOFLEX utilise vos coordonnées et les fichiers fournis pour examiner votre demande et y répondre. Les fichiers servent à l'établissement du devis et aux échanges techniques relatifs à votre demande. Consultez notre politique de confidentialité. politique de confidentialité pour obtenir des informations à jour sur le traitement et la conservation des données.

    * Champs obligatoires. Veuillez inclure les détails du câble principal ou de l'application pour examen.