Obtenir un devis
CÂBLES MINIERS ET DE TUNNELAGE Modèle / construction

Type SHD-CGC 5 kV Shielded Portable Mining Power Cable

Type SHD-CGC cable is a 5 kV, three-conductor shielded portable mining power cable with three grounding conductors and a centrally located ground-check conductor. It is intended for mobile mining equipment where a ground-check circuit and metallic insulation shielding are required.

  • tension: 5 kV reference configuration
  • Conducteurs de phase : stranded annealed tinned copper
  • Isolation: EPR with semi-conducting conductor shield
  • Insulation shield: non-conducting tape plus tinned copper/textile braid
  • Ground-check: yellow-insulated tinned copper conductor in the cable centre
  • Veste: reinforced extra-heavy-duty black CPE
  • Références standard : ICEA S-75-381/NEMA WC 58, ASTM B172, ASTM B33 and CAN/CSA C22.2 No. 96

Send the Type SHD-CGC size, equipment, voltage, route, length, movement duty and documentation requirement for a technical quotation.

Informations sur le produit
Marque
Modèle / construction
Présentation du produit

Type SHD-CGC 5 kV shielded portable mining power cable

TEBAOFLEX Type SHD-CGC cable is a three-conductor, shielded portable mining power cable for equipment that needs both a grounding system and a central ground-check conductor. The supplied 5 kV data set covers a heavy-duty EPR/CPE construction for mobile equipment circuits where a basic flexible feeder cable does not provide the required conductor arrangement or insulation shielding.

The practical buying question is not only conductor size. Confirm how the cable will move with the machine, whether the ground-check circuit is required at the termination, and whether the selected grounding-conductor size is compatible with the equipment and local mine rules. A cable that has the correct ampacity but the wrong check-ground layout can cause a costly field change before the machine enters service.

  • Convient pour : mobile AC mining equipment requiring three phase conductors, grounding conductors, a ground-check conductor and metallic shielding.
  • Reference range: Type SHD-CGC 3 × 2/0 AWG through 3 × 350 kcmil in the supplied 5 kV table.
  • Confirmez avant de commander : equipment voltage, conductor size, route, bending duty, terminations, ground-check interface and required documentation.
  • Choisissez une autre construction lorsque : the equipment does not require an individually shielded power construction or uses a different grounding/control-core arrangement.

Voir le gamme de câbles pour l'exploitation minière et le creusement de tunnels for other portable and feeder constructions. The detailed Type SHD-CGC data is organised in the technical tabs below.

Construction

Type SHD-CGC construction

The supplied Type SHD-CGC construction separates the three phase conductors from a central ground-check conductor and three grounding conductors. EPR insulation and a braided insulation shield are used inside a reinforced CPE outer jacket.

Type SHD-CGC cable cross-section showing three shielded power conductors, three grounding conductors and a central yellow ground-check conductor
Type SHD-CGC cross-section showing the supplied three-phase, grounding and central ground-check arrangement.
Type SHD-CGC construction elementConstruction fournie
conducteurs de phaseStranded annealed tinned copper conductor
blindage conducteurSemi-conducting layer
IsolationCaoutchouc éthylène-propylène (EPR)
écran d'isolationNon-conducting tape plus tinned copper/textile braid
conducteur de contrôle de mise à la terreTinned copper with yellow insulation, located in the centre of the cable
conducteurs de mise à la terreTinned copper conductors
Gaine extérieureReinforced extra-heavy-duty chlorinated polyethylene (CPE), black
Optional jacket materialsCSP, PCP, NBR or PVC available on request; a two-layer jacket with reinforcing fibre may be offered as an option
Applications

Type SHD-CGC applications

Type SHD-CGC heavy-duty cable is intended for longwall shearers, continuous miners, loaders, drills, conveyors, pumps and other mobile equipment where grounding conductors, a ground-check conductor and metallic shielding are required. It is relevant to portable AC mining circuits where the cable must follow the movement of the equipment instead of remaining as a fixed building feeder.

Open-pit mining equipment scene representing mobile mining duties for Type SHD-CGC portable power cable selection
Mining-equipment scene used to illustrate the mobile-duty environment; cable routing and movement must be confirmed for the specific machine.

Type SHD-CGC selection checks

  • Confirm that the equipment termination accepts the central ground-check conductor and three grounding conductors.
  • Match the phase size and supplied ampacity to the electrical design; account for route length and any project derating before final selection.
  • Plan support, bend control, routing and strain relief around moving equipment. The supplied minimum bending radius is 6 × the finished cable outer diameter.
  • Specify jacket option, cable length, marking, inspection and test documentation in the RFQ when the standard black CPE construction is not the final project requirement.

TEBAOFLEX can cross-check the existing cable marking and ground-check arrangement before quotation so a Type SHD-CGC request is matched to the machine connection rather than selected from phase conductor size alone.

Caractéristiques

Type SHD-CGC 5 kV specifications

The Type SHD-CGC values below are the supplied reference data. They apply to the listed three-conductor 5 kV configurations; final electrical selection must be checked against the project route and equipment requirements.

Désignation du produitType SHD-CGC shielded portable mining power cable
Reference voltage5 kV
Number of phase conductorsTrois
Maximum operating temperature+90 °C
rayon de courbure minimal6 × diamètre total

Type SHD-CGC dimensions and ampacity

ConstructionNo. of strandsconducteur de mise à la terreconducteur de contrôle de mise à la terreépaisseur de l'isolantépaisseur de la vesteDiamètre hors toutPoidsAmpacité
3 × 2/0 AWG3235 AWG16 AWG0.11 in / 2.8 mm0.220 in / 5.6 mm2.20 in / 55.9 mm3,716 lb/kft / 5,529 kg/km243 A
3 × 3/0 AWG4184 AWG16 AWG0.11 in / 2.8 mm0.235 in / 6.0 mm2.36 in / 59.9 mm4,130 lb/kft / 6,145 kg/km279 A
3 × 4/0 AWG5323 AWG16 AWG0.11 in / 2.8 mm0.235 in / 6.0 mm2.50 in / 63.5 mm5,190 lb/kft / 7,722 kg/km321 A
3 × 350 kcmil8881 AWG16 AWG0.12 in / 3.0 mm0.265 in / 6.7 mm2.95 in / 74.9 mm7,571 lb/kft / 11,264 kg/km435 A

Supplied ampacities are based on a 90 °C conductor temperature and 40 °C ambient air temperature, per ICEA S-75-381. Confirm actual installation and project derating before order release.

Normes

Normes

The following Type SHD-CGC standard references are listed in the supplied technical information.

Portable mining cable referenceICEA S-75-381 / NEMA WC 58
Conductor stranding referenceASTM B172
Tinned copper referenceASTM B33
Canadian portable power cable referenceCAN/CSA C22.2 n° 96

State the required standard edition, mine-site documentation, inspection and test-report requirements in the Type SHD-CGC RFQ.

Comparer par fonction

Options de câbles associées

Comparez ces options de câbles en fonction de la combinaison de services, du mouvement, de la charge, de la tension et des exigences de transmission.

devis basé sur l'ingénierie

Demandez une recommandation et un devis pour un câble.

Veuillez nous indiquer les services requis, la longueur du câble, les contraintes mécaniques, l'environnement, le type de terminaison et la quantité. Notre équipe examinera votre demande avant de vous établir un devis.

  • Veuillez inclure le nom du produit ou son SKU, ainsi que la longueur et la quantité de câble requises.
  • Joignez une fiche technique, un dessin ou une fiche de spécifications si disponible.

    Facultatif : joindre une spécification de câble, un dessin, une fiche technique ou une image du produit (PDF, DOC, DOCX, XLS, XLSX, CSV, JPG ou PNG ; maximum 10 Mo).

    En soumettant ce formulaire, vous acceptez que TEBAOFLEX utilise vos coordonnées et les fichiers fournis pour examiner votre demande et y répondre. Les fichiers servent à l'établissement du devis et aux échanges techniques relatifs à votre demande. Consultez notre politique de confidentialité. politique de confidentialité pour obtenir des informations à jour sur le traitement et la conservation des données.

    * Champs obligatoires. Veuillez inclure les détails du câble principal ou de l'application pour examen.