Obtenir un devis
Câbles d'alimentation au sol de l'aéroport Modèle / construction

400Hz Drag Chain Power & Control Cable for Passenger Boarding Bridges

400Hz drag chain cable for passenger boarding bridges combines a 0.6/1 kV power-cable module and a matched control-cable module on one system page. It is intended for drag-chain and festoon cable routes where the power and control circuits move with the boarding bridge.

  • System voltage: U0/U 0,6/1 kV
  • Power module: 7 × 35 mm², or 7 × 35 mm² + 6 × 6 mm²
  • Control module: 12 × 2 × 1.5 mm²
  • Movement references: 4 × d fixed, 6 × d flexible, 12 × d continuously flexible; torsion ±60°/1 m
  • Gaine extérieure : yellow halogen-free construction in supplied reference data

Send the PBB route, drag-chain geometry, free-hanging length, power/control circuit list, termination and documentation requirements for a technical quotation.

Informations sur le produit
Marque
Modèle / construction
Présentation du produit

400Hz drag chain cable for passenger boarding bridge systems

Ce 400Hz drag chain cable is a system-level selection page for the moving cable route on a passenger boarding bridge (PBB). It keeps the power cable and control cable in one documented product family because they share the same moving route, bend path and environmental exposure, while retaining their different conductor arrangements and electrical functions as separate specification modules.

Select the power module for the 400 Hz power circuit: either 7 × 35 mm² or 7 × 35 mm² + 6 × 6 mm². Select the control module for the stated 12 × 2 × 1.5 mm² paired-control arrangement. A 400Hz drag chain cable system should be specified against actual chain geometry, bend radius, torsion, free-hanging length, terminations and circuit separation rather than from conductor area alone.

  • Convient pour : stated drag-chain and festoon routes on passenger boarding bridges.
  • Power module: moving 400 Hz power distribution.
  • Control module: paired control circuits in the same PBB cable-management system.
  • Confirmez avant de commander : route, chain, travel, hanging length, circuits, connector and documents.

A 400Hz drag chain cable quotation should identify the power-module 400Hz drag chain cable and control-module 400Hz drag chain cable separately. This keeps the PBB circuit schedule, cable quantity and termination scope clear before the final 400Hz drag chain cable system is released.

Voir le gamme de câbles d’alimentation au sol pour aéroports for related GPU, feeder and reeling-cable families.

Construction

400Hz drag chain cable construction

The supplied 400Hz drag chain cable references use bare fine-wire copper conductors with IEC 60228 class 5 cited, halogen-free insulation, layered stranding with non-woven tape, and a yellow halogen-free outer sheath. The power and control modules have different core layouts, so their circuit schedule must be retained in the final design.

400Hz drag chain power cable cross-section showing seven 35 mm² power cores, six 6 mm² auxiliary cores and a central core
Power-module cross-section for the 7 × 35 mm² + 6 × 6 mm² reference construction.
400Hz drag chain control cable cross-section showing paired 1.5 mm² control cores
Control-module cross-section for the 12 × 2 × 1.5 mm² reference construction.
400Hz drag chain cable construction elementPower moduleControl module
ConducteurBare fine-wire copper; IEC 60228 class 5 referenceBare fine-wire copper; IEC 60228 class 5 reference
Reference core layout7 × 35 mm²; or 7 × 35 mm² + 6 × 6 mm²12 × 2 × 1.5 mm²
ÉchouageCores twisted in layers; wrapped elements in layers with overlapping non-woven tapePairs stranded in layers; wrapped elements in layers with overlapping non-woven tape
gaine extérieureYellow halogen-free sheath, as listed in supplied dataYellow halogen-free sheath, as listed in supplied data

Do not treat a power-module 400Hz drag chain cable and a control-module 400Hz drag chain cable as identical replacement parts; verify the circuit function and terminal schedule first.

Applications

Passenger boarding bridge drag-chain and festoon applications

This 400Hz drag chain cable family is intended for the stated moving cable routes on passenger boarding bridges: drag chains for guided travel and festoon routes for suspended movement. It is not a fixed feeder cable page and should not be selected for a static route without checking whether the movement construction is needed.

Passenger boarding bridge with suspended moving cable loops at an airport aircraft stand
Passenger boarding bridge cable-management environment; final routing and connectors must match the PBB design.
  • Power module: use when the PBB cable route carries the specified 400 Hz power conductors.
  • Control module: use when the route requires the specified paired control-circuit layout.
  • Drag-chain selection: confirm chain inner height, bend radius, travel, separation, support and termination strain relief.
  • Festoon selection: confirm free-hanging length, trolley spacing, loop geometry and stated 50 m reference limit.

A power-module 400Hz drag chain cable and a control-module 400Hz drag chain cable can share the PBB system while retaining separate circuit and termination schedules.

Each 400Hz drag chain cable installation must be checked for fixed, flexible or continuously flexible duty. The supplied bend-radius and torsion references are selection inputs, not a substitute for the completed PBB cable-management calculation.

For a cable-drum route rather than a drag-chain route, compare the related Câble de récupération de tambour 400 Hz.

Caractéristiques

400Hz drag chain cable specifications

The supplied 400Hz drag chain cable technical data applies to both the power and control modules unless a module row states otherwise. Confirm the selected module and final PBB movement conditions before quotation.

400Hz drag chain cable propertySource-listed value
Tension nominaleU0/U 0,6/1 kV
Tension d'essaiCore/core 4,000 V AC, 50 Hz
Minimum bend radius — fixed4 × d
Minimum bend radius — flexible6 × d
Minimum bend radius — continuously flexible12 × d
Torsion angle±60°/1 m
Temperature — fixed−50 °C to +90 °C
Temperature — flexible−40 °C to +90 °C
Free-hanging length for festoon application50 m

Use this 400Hz drag chain cable data with the actual PBB chain manufacturer limits and site route drawing.

Power module

400Hz drag chain cable power configurationDiamètre extérieurQuantité de cuivrePoids approximatif du câbleRésistance ohmique maximale
7 × 35 mm²Approx. 34.3 mm2,352 kg/km2,888 kg/km35 mm²: 0.55 Ω/km
7 × 35 mm² + 6 × 6 mm²Approx. 38.7–40.0 mm2,707 kg/km3,405 kg/km35 mm²: 0.55 Ω/km; 6 mm²: 3.3 Ω/km

The power-module 400Hz drag chain cable selection depends on the required 35 mm² power circuits and any required 6 mm² auxiliary circuits.

Control module

400Hz drag chain cable control configurationDiamètre extérieurQuantité de cuivrePoids approximatif du câbleRésistance ohmique maximale
12 × 2 × 1.5 mm²Approx. 20.7–22.0 mm346 kg/km529 kg/km1.5 mm²: 13.3 Ω/km

The control-module 400Hz drag chain cable data is for the supplied paired 1.5 mm² reference configuration.

The power and control modules are separate specification blocks on this 400Hz drag chain cable page because the final PBB system may require different routes, termination methods or cable quantities for each module.

Normes

400Hz drag chain cable standards and reference data

The following references are listed in the supplied 400Hz drag chain cable data. They are source-listed material, fire-performance or test references; confirm the required edition, test scope and project acceptance in the RFQ.

ObjetRéférence indiquée par la source
ConducteurIEC 60228 class 5
Flame propagationIEC 60332-3-24 + VDE 0482-332-3-24; IEC 60332-3-25 + VDE 0482-332-3-25; EN 50305 + VDE 0260-305 section 9.1.2
Flame retardancy / self-extinguishingIEC 60332-1-2 + VDE 0482-332-1-2
Flame-retardant referenceISO 6722 (UN/ECE R118)
Halogen-free material referencesEN 50306-1 + EN 50264-1; IEC 60754-1; IEC 60754-2; IEC 60684-2
Smoke densityIEC 61034 + VDE 0482-1034
ToxicityEN 50305 + VDE 0260-305
Oil and fuel resistanceEN 50264-1 + VDE 0260-264-1
Référence aux substances nocivesDirective RoHS de l’Union européenne

State the power or control 400Hz drag chain cable module when requesting the relevant reference documents.

Request the target PBB specification, required fire-performance evidence, connector/termination details and documents with the 400Hz drag chain cable enquiry.

Comparer par fonction

Options de câbles associées

Comparez ces options de câbles en fonction de la combinaison de services, du mouvement, de la charge, de la tension et des exigences de transmission.

devis basé sur l'ingénierie

Demandez une recommandation et un devis pour un câble.

Veuillez nous indiquer les services requis, la longueur du câble, les contraintes mécaniques, l'environnement, le type de terminaison et la quantité. Notre équipe examinera votre demande avant de vous établir un devis.

  • Veuillez inclure le nom du produit ou son SKU, ainsi que la longueur et la quantité de câble requises.
  • Joignez une fiche technique, un dessin ou une fiche de spécifications si disponible.

    Facultatif : joindre une spécification de câble, un dessin, une fiche technique ou une image du produit (PDF, DOC, DOCX, XLS, XLSX, CSV, JPG ou PNG ; maximum 10 Mo).

    En soumettant ce formulaire, vous acceptez que TEBAOFLEX utilise vos coordonnées et les fichiers fournis pour examiner votre demande et y répondre. Les fichiers servent à l'établissement du devis et aux échanges techniques relatifs à votre demande. Consultez notre politique de confidentialité. politique de confidentialité pour obtenir des informations à jour sur le traitement et la conservation des données.

    * Champs obligatoires. Veuillez inclure les détails du câble principal ou de l'application pour examen.