UL 5390 Mica-Glass Wire, 550°C 300V
UL 5390 is a UL-certified mica-glass wire rated 550°C and 300 V AC for internal equipment wiring. Its high-temperature insulation system combines mica with a treated fiberglass braid around the conductor.
- Napięcie: 300 V AC
- Temperatura: 550°C
- Izolacja / powłoka: mica composite with treated fiberglass braid
- Dobór przekroju: 24–4 AWG style range; table: 24–14 AWG
- Certyfikacja: AWM z certyfikatem UL; UL 758
UL 5390 wire selection
UL 5390 is a UL-certified mica-glass wire rated 550°C and 300 V AC for internal equipment wiring. Its high-temperature insulation system combines mica with a treated fiberglass braid around the conductor.
The dimension table gives six stranded nickel-coated copper configurations from 24 AWG to 14 AWG. Every row identifies UL 5390 with the wire size and includes strand count, finished diameter, approximate weight and minimum bend radius. A separate thickness schedule covers the wider 24–4 AWG style range. This keeps dimensioned constructions distinct from the broader conductor sizes permitted by the style.
For a hot-zone equipment lead, confirm the temperature at the wire and termination, the required operating voltage and the space available for a supported route. The 550°C rating does not increase the 300 V voltage rating. The optional stainless-steel braid shield is a separate construction choice and should be stated on the order if required; it is not included in the unshielded dimension table.
Tabele modeli i rozmiarów znajdują się w zakładce Specyfikacja. Przejrzyj kategorię gamę kabli wysokotemperaturowych for related constructions. Compare the 450°C MGT mica-glass wire and the separate 600 V UL 5359 construction.
Budowa
UL 5390 uses the following conductor and insulation system. The diagram illustrates the layer sequence; select the conductor construction and covering shown in the required size specification.

| Element | Szczegóły budowy |
|---|---|
| Żyła przewodząca | Stranded 27% nickel-coated copper in the dimensioned construction |
| Izolacja | Mica-glass composite |
| Powłoka zewnętrzna | Treated fiberglass braid |
| Optional style construction | 304 stainless-steel braid shield |
Zastosowania
UL 5390 is intended for internal equipment wiring requiring a 550°C mica-glass construction at 300 V AC. Review the hot-zone route, terminal materials and mechanical protection together before selecting the conductor size.

UL 5390 replacement selection
Przy zapytaniu o zamiennik podaj oznaczenie dotychczasowego przewodu i rysunek połączeń urządzenia, aby można było dopasować żyłę, izolację i układ zacisków.
Dane techniczne
| Parametr | Specyfikacja |
|---|---|
| Styl UL | UL 5390 |
| Napięcie znamionowe | 300 V AC |
| Klasa temperaturowa | 550°C |
| Izolacja / warstwa ochronna | mica composite with treated fiberglass braid |
| Zakres rozmiarów żył | 24–4 AWG style range; table: 24–14 AWG |
| Budowa | Single conductor with non-extruded insulation |
Unshielded 550°C, 300 V construction dimensions for selection. Values are nominal; the quotation drawing defines the supplied construction.
| Model i rozmiar żyły | Druciki | OD (mm) | OD (in) | Masa (kg/km) | Weight (lb/1000 ft) | Min. promień gięcia (in) |
|---|---|---|---|---|---|---|
| UL 5390 24 AWG | 7 | 2.03 | 0.080 | 7.22 | 5 | 0.64 |
| UL 5390 22 AWG | 7 | 2.21 | 0.087 | 8.86 | 6 | 0.70 |
| UL 5390 20 AWG | 10 | 2.34 | 0.092 | 10.37 | 7 | 0.74 |
| UL 5390 18 AWG | 16 | 2.64 | 0.104 | 15.30 | 10 | 0.83 |
| UL 5390 16 AWG | 26 | 3.05 | 0.120 | 22.49 | 15 | 0.96 |
| UL 5390 14 AWG | 41 | 3.30 | 0.130 | 29.69 | 20 | 1.04 |
Style construction thicknesses are shown in mils; 1 mil = 0.0254 mm. Nominal finished dimensions are listed separately.
| Model and conductor group | Minimum average composite wall (mils) | Minimum point wall (mils) |
|---|---|---|
| UL 5390 24–12 AWG | 25 | 22 |
| UL 5390 11–4 AWG | 33 | 30 |
Dobór wymaganej konstrukcji
Specify UL 5390 with AWG, conductor material, 300 V AC duty and any shield requirement. Use the selected row for nominal OD, weight and bend radius, and request a drawing for sizes beyond the dimensioned table.
Normy
TEBAOFLEX UL 5390 wire is UL-certified appliance wiring material.
| Pozycja | Wymaganie lub odniesienie |
|---|---|
| Certyfikacja | AWM z certyfikatem UL |
| Oznaczenie stylu | UL 5390 |
| Norma konstrukcyjna | UL 758 — Materiały do okablowania urządzeń |
| Klasyfikacja palności stylu | Pozioma próba płomieniowa |
W specyfikacji zakupowej podaj styl UL, rozmiar żyły oraz klasę napięciową i temperaturową. Do zapytania dołącz wymaganą identyfikację produktu i dokumenty certyfikacyjne.
Poproś o dobór kabla i wycenę
Prześlij wymagane funkcje, długość kabla, warunki pracy mechanicznej, środowisko, zakończenia i ilość. Nasz zespół przeanalizuje zastosowanie przed przygotowaniem wyceny.
- Podaj nazwę produktu lub SKU oraz wymaganą długość kabla i ilość.
- Jeśli są dostępne, dołącz specyfikację, rysunek lub kartę katalogową.