Obtenir un devis
Câbles haute température

UL 5390 Mica-Glass Wire, 550°C 300V

UL 5390 is a UL-certified mica-glass wire rated 550°C and 300 V AC for internal equipment wiring. Its high-temperature insulation system combines mica with a treated fiberglass braid around the conductor.

  • tension: 300 V AC
  • Température: 550°C
  • Isolation / revêtement : mica composite with treated fiberglass braid
  • Sélection de la taille : 24–4 AWG style range; table: 24–14 AWG
  • Certification : AWM certifié UL; UL 758
Informations sur le produit
Présentation du produit

UL 5390 wire selection

UL 5390 is a UL-certified mica-glass wire rated 550°C and 300 V AC for internal equipment wiring. Its high-temperature insulation system combines mica with a treated fiberglass braid around the conductor.

The dimension table gives six stranded nickel-coated copper configurations from 24 AWG to 14 AWG. Every row identifies UL 5390 with the wire size and includes strand count, finished diameter, approximate weight and minimum bend radius. A separate thickness schedule covers the wider 24–4 AWG style range. This keeps dimensioned constructions distinct from the broader conductor sizes permitted by the style.

For a hot-zone equipment lead, confirm the temperature at the wire and termination, the required operating voltage and the space available for a supported route. The 550°C rating does not increase the 300 V voltage rating. The optional stainless-steel braid shield is a separate construction choice and should be stated on the order if required; it is not included in the unshielded dimension table.

Consultez l’onglet Caractéristiques pour les tableaux de modèles et de calibres. Parcourez la gamme de câbles haute température for related constructions. Compare the 450°C MGT mica-glass wire and the separate 600 V UL 5359 construction.

Construction

Construction

UL 1813 utilise le système conducteur et d'isolation suivant. Le schéma illustre la séquence des couches ; sélectionnez la construction du conducteur et le revêtement indiqués dans les spécifications de taille requises.

Illustrative UL 5390 single-core conductor and insulation construction cutaway
Illustrative UL 5390 construction; layer dimensions are not to scale.
UL 5390 construction layers
Composantdétail de construction
ConducteurStranded 27% nickel-coated copper in the dimensioned construction
IsolationMica-glass composite
Revêtement extérieurTreated fiberglass braid
Optional style construction304 stainless-steel braid shield
Applications

Applications

UL 5390 is intended for internal equipment wiring requiring a 550°C mica-glass construction at 300 V AC. Review the hot-zone route, terminal materials and mechanical protection together before selecting the conductor size.

Illustrative UL 5390 insulated lead routed inside industrial equipment
Illustrative UL 5390 equipment application; shown as an installation concept.

UL 5390 replacement selection

Pour une demande de remplacement, fournissez le marquage du fil existant et le schéma de raccordement de l’équipement afin de comparer le conducteur, l’isolation et la disposition des bornes.

Caractéristiques

Caractéristiques techniques

UL 5390 technical data
ParamètreSpécification
Style ULUL 5390
Tension assignée300 V AC
Indice de température550°C
Isolation / revêtementmica composite with treated fiberglass braid
Plage de calibres du conducteur24–4 AWG style range; table: 24–14 AWG
ConstructionSingle conductor with non-extruded insulation

Unshielded 550°C, 300 V construction dimensions for selection. Values are nominal; the quotation drawing defines the supplied construction.

UL 5390 size and dimension table
Modèle et calibre du conducteurBrinsOD (mm)OD (in)Poids (kg/km)Weight (lb/1000 ft)Rayon de courbure min. (in)
UL 5390 24 AWG72.030.0807.2250.64
UL 5390 22 AWG72.210.0878.8660.70
UL 5390 20 AWG102.340.09210.3770.74
UL 5390 18 AWG162.640.10415.30100.83
UL 5390 16 AWG263.050.12022.49150.96
UL 5390 14 AWG413.300.13029.69201.04

Style construction thicknesses are shown in mils; 1 mil = 0.0254 mm. Nominal finished dimensions are listed separately.

UL 5390 insulation thickness by conductor size
Model and conductor groupMinimum average composite wall (mils)Minimum point wall (mils)
UL 5390 24–12 AWG2522
UL 5390 11–4 AWG3330

Choix de la construction spécifiée

Specify UL 5390 with AWG, conductor material, 300 V AC duty and any shield requirement. Use the selected row for nominal OD, weight and bend radius, and request a drawing for sizes beyond the dimensioned table.

Normes

Normes

TEBAOFLEX UL 5390 wire is UL-certified appliance wiring material.

UL 5390 certification and standards
ArticleExigence ou référence
CertificationAWM certifié UL
Désignation du styleUL 5390
Norme de constructionUL 758 — Matériaux de câblage pour appareils
Classement au feu du styleFlamme horizontale

Indiquez le style UL, le calibre du conducteur et les classes de tension et de température dans le cahier des charges. Joignez à la demande l’identification du produit et les documents de certification requis.

devis basé sur l'ingénierie

Demandez une recommandation et un devis pour un câble.

Veuillez nous indiquer les services requis, la longueur du câble, les contraintes mécaniques, l'environnement, le type de terminaison et la quantité. Notre équipe examinera votre demande avant de vous établir un devis.

  • Veuillez inclure le nom du produit ou son SKU, ainsi que la longueur et la quantité de câble requises.
  • Joignez une fiche technique, un dessin ou une fiche de spécifications si disponible.

    En soumettant ce formulaire, vous acceptez que TEBAOFLEX utilise vos coordonnées et les fichiers fournis pour examiner votre demande et y répondre. Les fichiers servent à établir le devis et aux échanges techniques liés à votre demande. Consultez notre politique de confidentialité pour obtenir des informations à jour sur le traitement et la conservation des données.

    * Champs obligatoires. Veuillez inclure les principaux détails du câble ou de l'application pour examen.