UL 5390 Mica-Glass Wire, 550°C 300V

UL 5390 is a UL-certified mica-glass wire rated 550°C and 300 V AC for internal equipment wiring. Its high-temperature insulation system combines mica with a treated fiberglass braid around the conductor.

  • Voltaje: 300 V AC
  • Temperatura: 550°C
  • Aislamiento / cubierta: mica composite with treated fiberglass braid
  • Selección de tamaño: 24–4 AWG style range; table: 24–14 AWG
  • Certificación: AWM con certificación UL; UL 758
Información del producto
Descripción general del producto

UL 5390 wire selection

UL 5390 is a UL-certified mica-glass wire rated 550°C and 300 V AC for internal equipment wiring. Its high-temperature insulation system combines mica with a treated fiberglass braid around the conductor.

The dimension table gives six stranded nickel-coated copper configurations from 24 AWG to 14 AWG. Every row identifies UL 5390 with the wire size and includes strand count, finished diameter, approximate weight and minimum bend radius. A separate thickness schedule covers the wider 24–4 AWG style range. This keeps dimensioned constructions distinct from the broader conductor sizes permitted by the style.

For a hot-zone equipment lead, confirm the temperature at the wire and termination, the required operating voltage and the space available for a supported route. The 550°C rating does not increase the 300 V voltage rating. The optional stainless-steel braid shield is a separate construction choice and should be stated on the order if required; it is not included in the unshielded dimension table.

Consulte la pestaña Especificaciones para ver las tablas de modelos y calibres. Explore la gama de cables de alta temperatura for related constructions. Compare the 450°C MGT mica-glass wire and the separate 600 V UL 5359 construction.

Construcción

Construcción

UL 1056 utiliza el sistema de conductor y aislamiento que se muestra a continuación. El diagrama indica el orden de las capas; seleccione la construcción del conductor y la cubierta que figuran en la especificación del calibre requerido.

Illustrative UL 5390 single-core conductor and insulation construction cutaway
Illustrative UL 5390 construction; layer dimensions are not to scale.
UL 5390 construction layers
ComponenteDetalle de construcción
ConductorStranded 27% nickel-coated copper in the dimensioned construction
AislamientoMica-glass composite
Cubierta exteriorTreated fiberglass braid
Optional style construction304 stainless-steel braid shield
Aplicaciones

Aplicaciones

UL 5390 is intended for internal equipment wiring requiring a 550°C mica-glass construction at 300 V AC. Review the hot-zone route, terminal materials and mechanical protection together before selecting the conductor size.

Illustrative UL 5390 insulated lead routed inside industrial equipment
Illustrative UL 5390 equipment application; shown as an installation concept.

UL 5390 replacement selection

Para solicitar un repuesto, envíe el marcado del cable existente y el plano de conexión del equipo. Así se podrán comparar el conductor, el aislamiento y la disposición de los terminales.

Especificaciones

Especificaciones

UL 5390 technical data
ParámetroEspecificación
Estilo ULUL 5390
Tensión nominal300 V AC
Clasificación de temperatura550°C
Aislamiento / revestimientomica composite with treated fiberglass braid
Rango de calibres del conductor24–4 AWG style range; table: 24–14 AWG
ConstrucciónSingle conductor with non-extruded insulation

Unshielded 550°C, 300 V construction dimensions for selection. Values are nominal; the quotation drawing defines the supplied construction.

UL 5390 size and dimension table
Modelo y calibre del conductorHebrasOD (mm)OD (in)Peso (kg/km)Weight (lb/1000 ft)Radio de curvatura mín. (in)
UL 5390 24 AWG72.030.0807.2250.64
UL 5390 22 AWG72.210.0878.8660.70
UL 5390 20 AWG102.340.09210.3770.74
UL 5390 18 AWG162.640.10415.30100.83
UL 5390 16 AWG263.050.12022.49150.96
UL 5390 14 AWG413.300.13029.69201.04

Style construction thicknesses are shown in mils; 1 mil = 0.0254 mm. Nominal finished dimensions are listed separately.

UL 5390 insulation thickness by conductor size
Model and conductor groupMinimum average composite wall (mils)Minimum point wall (mils)
UL 5390 24–12 AWG2522
UL 5390 11–4 AWG3330

Selección de la construcción especificada

Specify UL 5390 with AWG, conductor material, 300 V AC duty and any shield requirement. Use the selected row for nominal OD, weight and bend radius, and request a drawing for sizes beyond the dimensioned table.

Estándares

Normas

TEBAOFLEX UL 5390 wire is UL-certified appliance wiring material.

UL 5390 certification and standards
ArtículoRequisito o referencia
CertificaciónAWM con certificación UL
Designación del estiloUL 5390
Norma de construcciónUL 758 — Material de cableado para aparatos
Clasificación de inflamabilidad del estiloLlama horizontal

Indique el estilo UL, el calibre del conductor y los valores de tensión y temperatura en la especificación de compra. Incluya en la consulta la identificación del producto y los documentos de certificación requeridos.

Cotización basada en ingeniería

Solicite una recomendación y un presupuesto de cables.

Indique los servicios requeridos, la longitud del cable, la carga mecánica, el entorno, el tipo de terminación y la cantidad. Nuestro equipo revisará la solicitud antes de elaborar un presupuesto.

  • Incluya el nombre del producto o SKU, así como la longitud y la cantidad de cable requeridas.
  • Adjunte una especificación, un dibujo o una hoja de datos cuando esté disponible.

    Al enviar este formulario, acepta que TEBAOFLEX utilice los datos de contacto y los archivos proporcionados para revisar y responder a su consulta. Los archivos se utilizan para elaborar la cotización y para la comunicación técnica relacionada con su solicitud. Consulte nuestra política de privacidad para obtener información actualizada sobre el manejo y la retención de datos.

    * Campos obligatorios. Incluya los datos clave del cable o de la aplicación para su revisión.