Get a Quote
High Temperature Cables

UL 5390 Mica-Glass Wire, 550°C 300V

UL 5390 is a UL-certified mica-glass wire rated 550°C and 300 V AC for internal equipment wiring. Its high-temperature insulation system combines mica with a treated fiberglass braid around the conductor.

  • Voltage: 300 V AC
  • Temperature: 550°C
  • Insulation / covering: mica composite with treated fiberglass braid
  • Size selection: 24–4 AWG style range; table: 24–14 AWG
  • Certification: UL-certified AWM; UL 758
Product information
Product overview

UL 5390 wire selection

UL 5390 is a UL-certified mica-glass wire rated 550°C and 300 V AC for internal equipment wiring. Its high-temperature insulation system combines mica with a treated fiberglass braid around the conductor.

The dimension table gives six stranded nickel-coated copper configurations from 24 AWG to 14 AWG. Every row identifies UL 5390 with the wire size and includes strand count, finished diameter, approximate weight and minimum bend radius. A separate thickness schedule covers the wider 24–4 AWG style range. This keeps dimensioned constructions distinct from the broader conductor sizes permitted by the style.

For a hot-zone equipment lead, confirm the temperature at the wire and termination, the required operating voltage and the space available for a supported route. The 550°C rating does not increase the 300 V voltage rating. The optional stainless-steel braid shield is a separate construction choice and should be stated on the order if required; it is not included in the unshielded dimension table.

See the Specifications tab for the model and size tables. Browse the high-temperature cable range for related constructions. Compare the 450°C MGT mica-glass wire and the separate 600 V UL 5359 construction.

Construction

Construction

UL 5390 uses the following conductor and insulation system. The diagram illustrates the layer sequence; select the conductor construction and covering shown in the required size specification.

Illustrative UL 5390 single-core conductor and insulation construction cutaway
Illustrative UL 5390 construction; layer dimensions are not to scale.
UL 5390 construction layers
ComponentConstruction detail
ConductorStranded 27% nickel-coated copper in the dimensioned construction
InsulationMica-glass composite
Outer coveringTreated fiberglass braid
Optional style construction304 stainless-steel braid shield
Applications

Applications

UL 5390 is intended for internal equipment wiring requiring a 550°C mica-glass construction at 300 V AC. Review the hot-zone route, terminal materials and mechanical protection together before selecting the conductor size.

Illustrative UL 5390 insulated lead routed inside industrial equipment
Illustrative UL 5390 equipment application; shown as an installation concept.

UL 5390 replacement selection

For replacement enquiries, include the existing wire marking and the equipment connection drawing so the conductor, insulation and terminal arrangement can be matched.

Specifications

Specifications

UL 5390 technical data
ParameterSpecification
UL styleUL 5390
Voltage rating300 V AC
Temperature rating550°C
Insulation / coveringmica composite with treated fiberglass braid
Conductor size coverage24–4 AWG style range; table: 24–14 AWG
ConstructionSingle conductor with non-extruded insulation

Unshielded 550°C, 300 V construction dimensions for selection. Values are nominal; the quotation drawing defines the supplied construction.

UL 5390 size and dimension table
Model and conductor sizeStrandsOD (mm)OD (in)Weight (kg/km)Weight (lb/1000 ft)Min. bend radius (in)
UL 5390 24 AWG72.030.0807.2250.64
UL 5390 22 AWG72.210.0878.8660.70
UL 5390 20 AWG102.340.09210.3770.74
UL 5390 18 AWG162.640.10415.30100.83
UL 5390 16 AWG263.050.12022.49150.96
UL 5390 14 AWG413.300.13029.69201.04

Style construction thicknesses are shown in mils; 1 mil = 0.0254 mm. Nominal finished dimensions are listed separately.

UL 5390 insulation thickness by conductor size
Model and conductor groupMinimum average composite wall (mils)Minimum point wall (mils)
UL 5390 24–12 AWG2522
UL 5390 11–4 AWG3330

Selecting the specified construction

Specify UL 5390 with AWG, conductor material, 300 V AC duty and any shield requirement. Use the selected row for nominal OD, weight and bend radius, and request a drawing for sizes beyond the dimensioned table.

Standards

Standards

TEBAOFLEX UL 5390 wire is UL-certified appliance wiring material.

UL 5390 certification and standards
ItemRequirement or reference
CertificationUL-certified AWM
Style designationUL 5390
Construction standardUL 758 — Appliance Wiring Material
Style flame classificationHorizontal flame

Identify the UL style, conductor size, voltage and temperature grade on the purchasing specification. Include the required product identification and certification documents with the enquiry.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    * Required fields. Please include the key cable or application details for review.