UL 3645 Covered Silicone Wire, 200°C 1000V
UL 3645 is a UL-certified covered silicone wire rated 1000 V AC, with 150°C and 200°C constructions. The version shown here adds a fiberglass braid over the silicone insulation for internal appliance or electronic equipment wiring.
- Napięcie: 1000 V AC
- Temperatura: 150°C or 200°C by construction
- Izolacja / powłoka: silicone rubber with a supplied glass-braid covering
- Dobór przekroju: 30 AWG–750 kcmil style range; table: 30 AWG–4/0 AWG
- Certyfikacja: AWM z certyfikatem UL; UL 758
UL 3645 wire selection
UL 3645 is a UL-certified covered silicone wire rated 1000 V AC, with 150°C and 200°C constructions. The version shown here adds a fiberglass braid over the silicone insulation for internal appliance or electronic equipment wiring.
The 19-row size table spans 30 AWG through 4/0 AWG and identifies the nominal silicone wall, 0.16 mm glass covering and finished diameter for each listed construction. The outer braid is part of the finished size, so it must be included when checking sleeves, clamps and terminal entries. The separate style schedule covers additional conductor groups up to 750 kcmil without assigning unverified finished diameters to them.
Select the temperature grade and covering before comparing this wire with an uncovered silicone lead. The same AWG and voltage can still lead to a different outside diameter and stripping procedure. For the listed constructions, allow a bend radius of 10 times finished diameter and support the lead so the braid does not rub against sharp equipment edges.
Tabele modeli i rozmiarów znajdują się w zakładce Specyfikacja. Przejrzyj kategorię gamę kabli wysokotemperaturowych for related constructions. Compare bare UL 3644 and the lower-voltage rodzina plecionych przewodów silikonowych.
Budowa
UL 3645 uses the following conductor and insulation system. The diagram illustrates the layer sequence; select the conductor construction and covering shown in the required size specification.

| Element | Szczegóły budowy |
|---|---|
| Żyła przewodząca | Solid or stranded copper; dimensioned examples are stranded |
| Izolacja | Wytłaczana guma silikonowa |
| Powłoka zewnętrzna | Fiberglass braid; 0.16 mm in dimensioned examples |
Zastosowania
UL 3645 is used for internal appliance and electronic equipment wiring that specifies a covering over silicone insulation. Review the braid finish and termination arrangement where the covering ends near a connector.

UL 3645 replacement selection
Przy zapytaniu o zamiennik podaj oznaczenie dotychczasowego przewodu i rysunek połączeń urządzenia, aby można było dopasować żyłę, izolację i układ zacisków.
Dane techniczne
| Parametr | Specyfikacja |
|---|---|
| Styl UL | UL 3645 |
| Napięcie znamionowe | 1000 V AC |
| Klasa temperaturowa | 150°C or 200°C by construction |
| Izolacja / warstwa ochronna | silicone rubber with a supplied glass-braid covering |
| Zakres rozmiarów żył | 30 AWG–750 kcmil style range; table: 30 AWG–4/0 AWG |
| Bending radius for listed construction | 10 × finished OD |
Nominal dimensions follow the listed conductor constructions. Confirm the agreed finished-diameter drawing for tight-clearance assemblies.
| Model i rozmiar żyły | Liczba drutów żyły (szt./mm) | Nominal silicone wall (mm) | Glass covering (mm) | Nominalna średnica zewnętrzna / tolerancja (mm) |
|---|---|---|---|---|
| UL 3645 4/0 AWG | 2146/0.254 | 2.09 | 0.16 | 18.09 ±0.15 |
| UL 3645 3/0 AWG | 1615/0.254 | 2.09 | 0.16 | 16.30 ±0.15 |
| UL 3645 2/0 AWG | 1330/0.254 | 2.09 | 0.16 | 15.20 ±0.15 |
| UL 3645 1/0 AWG | 1026/0.254 | 2.09 | 0.16 | 13.90 ±0.15 |
| UL 3645 2 AWG | 665/0.254 | 1.58 | 0.16 | 11.05 ±0.15 |
| UL 3645 4 AWG | 420/0.254 | 1.58 | 0.16 | 9.50 ±0.15 |
| UL 3645 6 AWG | 259/0.254 | 1.58 | 0.16 | 8.21 ±0.15 |
| UL 3645 8 AWG | 161/0.254 | 1.58 | 0.16 | 7.20 ±0.15 |
| UL 3645 10 AWG | 105/0.254 | 1.20 | 0.16 | 5.73 ±0.15 |
| UL 3645 12 AWG | 65/0.254 | 1.20 | 0.16 | 5.09 ±0.15 |
| UL 3645 14 AWG | 41/0.254 | 1.20 | 0.16 | 4.60 ±0.15 |
| UL 3645 16 AWG | 26/0.254 | 1.20 | 0.16 | 4.22 ±0.15 |
| UL 3645 18 AWG | 34/0.18 | 1.20 | 0.16 | 3.94 ±0.15 |
| UL 3645 20 AWG | 21/0.18 | 1.20 | 0.16 | 3.68 ±0.15 |
| UL 3645 22 AWG | 17/0.16 | 1.20 | 0.16 | 3.49 ±0.15 |
| UL 3645 24 AWG | 11/0.16 | 1.20 | 0.16 | 3.34 ±0.15 |
| UL 3645 26 AWG | 7/0.16 | 1.20 | 0.16 | 3.21 ±0.15 |
| UL 3645 28 AWG | 7/0.127 | 1.20 | 0.16 | 3.11 ±0.15 |
| UL 3645 30 AWG | 7/0.10 | 1.20 | 0.16 | 3.03 ±0.15 |
Style construction thicknesses are shown in mils; 1 mil = 0.0254 mm. Nominal finished dimensions are listed separately.
| Model and conductor group | Minimum average silicone wall (mils) | Minimum point wall (mils) |
|---|---|---|
| UL 3645 30–10 AWG | 45 | 40 |
| UL 3645 8–2 AWG | 60 | 54 |
| UL 3645 1–4/0 AWG | 80 | 72 |
| UL 3645 250–500 kcmil | 95 | 85 |
| UL 3645 501–750 kcmil | 110 | 99 |
Dobór wymaganej konstrukcji
Specify UL 3645 with size, temperature grade and fiberglass covering. Match the covered finished diameter to clamps and sleeves instead of using a bare-silicone dimension.
Normy
TEBAOFLEX UL 3645 wire is UL-certified appliance wiring material.
| Pozycja | Wymaganie lub odniesienie |
|---|---|
| Certyfikacja | AWM z certyfikatem UL |
| Oznaczenie stylu | UL 3645 |
| Norma konstrukcyjna | UL 758 — Materiały do okablowania urządzeń |
| Klasyfikacja palności stylu | Pozioma próba płomieniowa |
W specyfikacji zakupowej podaj styl UL, rozmiar żyły oraz klasę napięciową i temperaturową. Do zapytania dołącz wymaganą identyfikację produktu i dokumenty certyfikacyjne.
Poproś o dobór kabla i wycenę
Prześlij wymagane funkcje, długość kabla, warunki pracy mechanicznej, środowisko, zakończenia i ilość. Nasz zespół przeanalizuje zastosowanie przed przygotowaniem wyceny.
- Podaj nazwę produktu lub SKU oraz wymaganą długość kabla i ilość.
- Jeśli są dostępne, dołącz specyfikację, rysunek lub kartę katalogową.