UL 3645 Covered Silicone Wire, 200°C 1000V
UL 3645 is a UL-certified covered silicone wire rated 1000 V AC, with 150°C and 200°C constructions. The version shown here adds a fiberglass braid over the silicone insulation for internal appliance or electronic equipment wiring.
- Tensão: 1000 V AC
- Temperatura: 150°C or 200°C by construction
- Isolamento / revestimento: silicone rubber with a supplied glass-braid covering
- Seleção de tamanho: 30 AWG–750 kcmil style range; table: 30 AWG–4/0 AWG
- Certificação: AWM com certificação UL; UL 758
UL 3645 wire selection
UL 3645 is a UL-certified covered silicone wire rated 1000 V AC, with 150°C and 200°C constructions. The version shown here adds a fiberglass braid over the silicone insulation for internal appliance or electronic equipment wiring.
The 19-row size table spans 30 AWG through 4/0 AWG and identifies the nominal silicone wall, 0.16 mm glass covering and finished diameter for each listed construction. The outer braid is part of the finished size, so it must be included when checking sleeves, clamps and terminal entries. The separate style schedule covers additional conductor groups up to 750 kcmil without assigning unverified finished diameters to them.
Select the temperature grade and covering before comparing this wire with an uncovered silicone lead. The same AWG and voltage can still lead to a different outside diameter and stripping procedure. For the listed constructions, allow a bend radius of 10 times finished diameter and support the lead so the braid does not rub against sharp equipment edges.
Consulte o separador Especificações para ver as tabelas de modelos e tamanhos. Explore a gama de cabos de alta temperatura for related constructions. Compare bare UL 3644 and the lower-voltage família de fios de silicone trançados.
Construção
O UL 1056 utiliza o sistema de condutor e isolamento indicado a seguir. O esquema mostra a sequência das camadas; selecione a construção do condutor e o revestimento previstos na especificação do tamanho necessário.

| Componente | Detalhes da construção |
|---|---|
| Condutor | Solid or stranded copper; dimensioned examples are stranded |
| Isolamento | Borracha de silicone extrudida |
| Revestimento exterior | Fiberglass braid; 0.16 mm in dimensioned examples |
Aplicações
UL 3645 is used for internal appliance and electronic equipment wiring that specifies a covering over silicone insulation. Review the braid finish and termination arrangement where the covering ends near a connector.

UL 3645 replacement selection
Para pedir um fio de substituição, envie a marcação do fio existente e o esquema de ligação do equipamento. Assim, podem comparar-se o condutor, o isolamento e a disposição dos terminais.
Especificações
| Parâmetro | Especificação |
|---|---|
| Estilo UL | UL 3645 |
| Tensão nominal | 1000 V AC |
| Classificação de temperatura | 150°C or 200°C by construction |
| Isolamento/revestimento | silicone rubber with a supplied glass-braid covering |
| Gama de tamanhos do condutor | 30 AWG–750 kcmil style range; table: 30 AWG–4/0 AWG |
| Bending radius for listed construction | 10 × finished OD |
Nominal dimensions follow the listed conductor constructions. Confirm the agreed finished-diameter drawing for tight-clearance assemblies.
| Modelo e tamanho do condutor | Fios do condutor (n.º/mm) | Nominal silicone wall (mm) | Glass covering (mm) | Diâmetro externo nominal / tolerância (mm) |
|---|---|---|---|---|
| UL 3645 4/0 AWG | 2146/0.254 | 2.09 | 0.16 | 18.09 ±0.15 |
| UL 3645 3/0 AWG | 1615/0.254 | 2.09 | 0.16 | 16.30 ±0.15 |
| UL 3645 2/0 AWG | 1330/0.254 | 2.09 | 0.16 | 15.20 ±0.15 |
| UL 3645 1/0 AWG | 1026/0.254 | 2.09 | 0.16 | 13.90 ±0.15 |
| UL 3645 2 AWG | 665/0.254 | 1.58 | 0.16 | 11.05 ±0.15 |
| UL 3645 4 AWG | 420/0.254 | 1.58 | 0.16 | 9.50 ±0.15 |
| UL 3645 6 AWG | 259/0.254 | 1.58 | 0.16 | 8.21 ±0.15 |
| UL 3645 8 AWG | 161/0.254 | 1.58 | 0.16 | 7.20 ±0.15 |
| UL 3645 10 AWG | 105/0.254 | 1.20 | 0.16 | 5.73 ±0.15 |
| UL 3645 12 AWG | 65/0.254 | 1.20 | 0.16 | 5.09 ±0.15 |
| UL 3645 14 AWG | 41/0.254 | 1.20 | 0.16 | 4.60 ±0.15 |
| UL 3645 16 AWG | 26/0.254 | 1.20 | 0.16 | 4.22 ±0.15 |
| UL 3645 18 AWG | 34/0.18 | 1.20 | 0.16 | 3.94 ±0.15 |
| UL 3645 20 AWG | 21/0.18 | 1.20 | 0.16 | 3.68 ±0.15 |
| UL 3645 22 AWG | 17/0.16 | 1.20 | 0.16 | 3.49 ±0.15 |
| UL 3645 24 AWG | 11/0.16 | 1.20 | 0.16 | 3.34 ±0.15 |
| UL 3645 26 AWG | 7/0.16 | 1.20 | 0.16 | 3.21 ±0.15 |
| UL 3645 28 AWG | 7/0.127 | 1.20 | 0.16 | 3.11 ±0.15 |
| UL 3645 30 AWG | 7/0.10 | 1.20 | 0.16 | 3.03 ±0.15 |
Style construction thicknesses are shown in mils; 1 mil = 0.0254 mm. Nominal finished dimensions are listed separately.
| Model and conductor group | Minimum average silicone wall (mils) | Minimum point wall (mils) |
|---|---|---|
| UL 3645 30–10 AWG | 45 | 40 |
| UL 3645 8–2 AWG | 60 | 54 |
| UL 3645 1–4/0 AWG | 80 | 72 |
| UL 3645 250–500 kcmil | 95 | 85 |
| UL 3645 501–750 kcmil | 110 | 99 |
Seleção da construção especificada
Specify UL 3645 with size, temperature grade and fiberglass covering. Match the covered finished diameter to clamps and sleeves instead of using a bare-silicone dimension.
Normas
TEBAOFLEX UL 3645 wire is UL-certified appliance wiring material.
| Item | Requisito ou referência |
|---|---|
| Certificação | AWM com certificação UL |
| Designação do estilo | UL 3645 |
| Norma de construção | UL 758 — Material de cablagem para aparelhos |
| Classificação de inflamabilidade do estilo | Chama horizontal |
Indique o estilo UL, o tamanho do condutor e as classificações de tensão e temperatura na especificação de compra. Junte ao pedido a identificação do produto e os documentos de certificação exigidos.
Solicite uma recomendação e orçamento de cabos.
Envie-nos as especificações dos serviços necessários, comprimento do cabo, capacidade mecânica, ambiente, tipo de terminação e quantidade. Nossa equipe analisará a solicitação antes de enviar um orçamento.
- Inclua o nome do produto ou o código SKU, além do comprimento e da quantidade de cabos necessários.
- Anexe uma especificação, desenho ou ficha técnica, quando disponíveis.