Solicite um orçamento
CABOS PARA MINERAÇÃO E ESCAVAÇÃO DE TÚNEIS TEBAOFLEX

Type G Cable 2 kV Portable Mining Power Cable

Type G Cable is a 2,000 V portable power cable for stated industrial and mining applications requiring grounding.

  • Maestros: flexible stranded bare or tin-coated copper
  • Isolamento: colour-coded 90°C EPDM
  • Ground wires: green EPDM-insulated copper
  • Jaqueta: flame-retardant, oil- and sunlight-resistant CPE
  • Faixa de tamanhos: 8 AWG to 500 MCM

Request Type G Mining Cable pricing with the conductor count, gauge, length and application details.

Informações sobre o produto
Marca
TEBAOFLEX
Visão geral do produto

Type G Cable 2 kV portable mining power cable

TEBAOFLEX Type G Cable is a 2,000 V portable power cable for three- and four-wire AC systems requiring grounding. The supplied Type G Mining Cable information identifies industrial and mining uses, including mining equipment, cranes, conveyors, mobile equipment, electromagnets and oil-drilling equipment. Its stated design combines flexible annealed stranded copper conductors, colour-coded EPDM insulation, multiple insulated grounding conductors and a reinforced thermoset CPE jacket.

The Type G Cable configuration uses the same number of ground wires as primary conductors. The supplied information states that the total ground-wire cross-sectional area is roughly equal to that of the primary conductors. This arrangement, along with the supplied EPDM insulation and CPE outer jacket, is intended for portable cable duties exposed to heat, acids, oil, moisture and demanding environmental conditions.

  • Classificação de tensão: 2,000 V.
  • Faixa de temperatura: −40°C to +90°C.
  • Available construction: three or four pure stranded copper phase conductors with three or four green ground wires.
  • Faixa de tamanhos: 8 AWG to 500 MCM.

For the final Type G Mining Cable selection, confirm conductor count, size, equipment connection, route, ambient conditions, required approvals, length and documentation. Explore the gama de cabos para mineração e tunelamento for related portable cable constructions.

Construção

Type G Cable construction

The supplied Type G Cable design uses flexible copper phase conductors and matching green grounding conductors within EPDM insulation and a reinforced CPE outer jacket.

Type G Cable cutaway showing coloured insulated copper conductors, green grounding conductors and black CPE jacket
Type G Cable construction view; final core count and configuration follow the approved order drawing.
Elemento de construçãoSupplied Type G Mining Cable reference
Condutores de faseFully annealed stranded bare or tin-coated copper; rope-lay stranding for flexibility
IsolamentoPremium-grade colour-coded 90°C ethylene-propylene-diene monomer (EPDM)
Ground conductorsGreen EPDM-insulated bare or tinned copper stranding; same number as primary conductors
Ground-wire areaTotal area stated as roughly equal to the primary-conductor cross-sectional area
Bainha exteriorFlame-retardant, oil- and sunlight-resistant chlorinated polyethylene (CPE), rated 90°C
OptionsOther sizes, colours and custom designs on request; EPR available on request
Aplicações

Aplicações

Type G Mining Cable is supplied for portable power duties on three- and four-wire AC systems requiring grounding. The supplied applications include mining equipment, cranes, conveyors, mobile equipment, electromagnets and oil-drilling equipment. Type G Cable is also described for temporary power supply duty in industrial and mining use.

Type G Mining Cable connected to underground mining equipment in a wet mine environment
Underground mobile-equipment connection illustrating a Type G Mining Cable application.

Selection checks

  • Confirm whether a three- or four-conductor Type G Cable configuration is required, together with the grounding arrangement.
  • Check the conductor size against load, voltage drop, route, protective device and installation conditions.
  • Review exposure to impact, abrasion, heat, acids, oil, moisture and weather with the actual site engineering requirements.
  • Specify the required length, colour code, jacket option, approvals and documentation with the enquiry.

The supplied Type G Cable construction is not interchangeable with Type G-GC or Type GC cable arrangements: confirm the required ground and ground-check functions before final selection.

Especificações

Type G Cable specifications

The following nominal four-conductor Type G Cable data is transcribed from the supplied information. All dimensions are nominal and subject to normal manufacturing tolerance.

Tamanho do condutorNo. of conductorsEncalheGround conductorEspessura do isolamentoApprox. diameterNet weight
8 AWG41334 × 12 AWG1.520 mm (0.060 in)26.540 mm (1.045 in)945 kg/km (635 lb/MFT)
6 AWG42594 × 12 AWG1.520 mm (0.060 in)28.580 mm (1.125 in)1,339 kg/km (900 lb/MFT)
4 AWG42594 × 10 AWG1.520 mm (0.060 in)30.730 mm (1.210 in)1,905 kg/km (1,280 lb/MFT)
2 AWG42594 × 9 AWG2.030 mm (0.080 in)36.450 mm (1.435 in)2,976 kg/km (2,000 lb/MFT)
1/0 AWG42594 × 7 AWG2.030 mm (0.080 in)43.69 mm (1.720 in)4,672 kg/km (3,140 lb/MFT)
2/0 AWG42594 × 6 AWG2.030 mm (0.080 in)47.240 mm (1.860 in)5,625 kg/km (3,780 lb/MFT)
3/0 AWG42594 × 5 AWG2.030 mm (0.080 in)52.710 mm (2.075 in)6,696 kg/km (4,500 lb/MFT)
4/0 AWG42594 × 5 AWG2.030 mm (0.080 in)54.740 mm (2.155 in)8,214 kg/km (5,520 lb/MFT)
500 MCM41,2354 × 1/0 AWG2.413 mm (0.095 in)86.400 mm (3.400 in)16,008 kg/km (10,758 lb/MFT)

Additional supplied size references

Tamanho do condutorEncalheGround conductorEspessura do isolamentoDiâmetro externoMaterial weight
250 kcmil4274 × 3 AWG0.095 in2.77 in7,143 lb/M
350 kcmil8884 × 2 AWG0.095 in3.10 in6,567 lb/M

For shared sizes, source tables supplied for this page show differing nominal weights and dimensions. Confirm the approved manufacturing drawing and final quotation data before ordering.

Padrões

Standards and supplied approval references

The supplied Type G Cable information lists the following standards and approval/compliance references.

NormasCSA FT5; ASTM B172 and B33; MSHA P-7K-268101; ICEA S-75-381 / NEMA WC-58; ICEA S-68-516 / NEMA WC-8
Flame-test referencesMSHA P-122 MSHA flame-resistance; UL 1581 vertical tray flame test
Portable power cable referenceUL 1650 Portable Power Cable
Other supplied referencesCSA approved; MSHA listed; RoHS compliant

State the required standard edition, approval scope, test report and documentation requirements in the enquiry.

Comparar por dever

Opções de cabos relacionadas

Compare estas opções de cabos por combinação de serviços, movimentação, carga, tensão e requisito de transmissão.

Cotação elaborada por engenheiros

Solicite uma recomendação e orçamento de cabos.

Envie-nos as especificações dos serviços necessários, comprimento do cabo, capacidade mecânica, ambiente, tipo de terminação e quantidade. Nossa equipe analisará a solicitação antes de enviar um orçamento.

  • Inclua o nome do produto ou o código SKU, além do comprimento e da quantidade de cabos necessários.
  • Anexe uma especificação, desenho ou ficha técnica, quando disponíveis.

    Opcional: anexe uma especificação do cabo, desenho, ficha técnica ou imagem do produto (PDF, DOC, DOCX, XLS, XLSX, CSV, JPG ou PNG; máximo de 10 MB).

    Ao enviar este formulário, você concorda que a TEBAOFLEX pode usar as informações de contato e os arquivos fornecidos para analisar e responder à sua solicitação. Os arquivos são usados para orçamentos e comunicação técnica relacionados à sua solicitação. Consulte nossa política de privacidade. política de Privacidade Para obter informações atuais sobre o tratamento e a retenção de dados.

    * Campos obrigatórios. Inclua os detalhes principais do cabo ou da aplicação para análise.